You are on page 1of 41

Parameter Audit

NSN – Mobinil propriety confidential data


Agenda

1. Objective & Audit Plan

2. Audit main entities

NSN – Mobinil propriety confidential data


Objective and Audit Plan

Objective:
Audit the main 3G parameters for the different RRM functions Delta
3 RNCs [RNC 12 , RNC20, RNC 2] and check for inconsistencies or proposing
new parameter values to improve the network performance.
:

NSN – Mobinil propriety confidential data


Agenda

1. Objective & Audit Plan

2. Radio Resource Management Audit

NSN – Mobinil propriety confidential data


Radio Resource Management Audit

• Power, Load & Admission control


• Handover Control
• Packet Scheduling
• HSDPA Parameters.
• HSUPA Parameters.

NSN – Mobinil propriety confidential data


Radio Resource Management Audit

• Power, Load & Admission control


• Power Control
• Load Control
• Admission Control
• Packet Scheduling
• Handover Control
• HSDPA Parameters.
• HSUPA Parameters.

NSN – Mobinil propriety confidential data


Executive Summary

 Consistency check:

 Discrepancies were found for Only one site for one Parameter only as
Shonw

• CableLoss ( site 26_NS_Mans_Sadat)

Power Control

NSN – Mobinil propriety confidential data


Radio Resource Management Audit
Power , Load & Admission Control
- Power Control Parameters
Deployed
% of cells at
Object AbbreviatedName Default Values Comments
Default
Range

Parameter defines the adjustment ratio, convergence rate to


RNC HCPC DownlinkInnerLoopPCStepSize 1 100% 1 reference power. No value because Power balancing isn't used

The DL inner loop PC step size is used in normal mode by the


RNC HCPC StepSizeForDCHBLER 30 100% 30 WCDMA BTS to calculate the power increase/decrease when
receiving TPC commands

Step Size for DCH BLER weighs the DCH BLER impact to the Delta
RNC HCPC EnableULQualDetRep 1 100% 1 SIR.

Parameter enables or disables the quality deterioration report from


RNC HCPC ULQualDetRepThreshold 1 0% 10 UL OLPC controller procedure. Recommended 10

If the uplink SIR target has reached the maximum, and the uplink
SIR Target modification commands received by the outer loop PC
controller from the current active PC Entity during
ULQualDetRepThreshold seconds are all greater than zero, then the
uplink outer loop PC controller sends a quality deterioration report
RNC HCPC DownlinkInnerLoopPCStepSize 1 100% 1 to HC. The quality deterioration message to the HC is periodically
repeated, with ULQualDetREpTreshold defining the period, until
either the quality target is resumed, meaning that the condition
specified above is no longer met, or further actions are taken by
HC.

NSN – Mobinil propriety confidential data


- Power Control Parameters ( Cont. )
Deployed
% of cells at
Object AbbreviatedName Default Values Comments
Default
Range

This is the transmission power of the primary synchronization


WCEL PtxPrimarySCH -30 100% -30 channel.

This is the transmission power of the secondary synchronisation


WCEL PtxSecSCH -30 100% -30 channel related to the primary CPICH transmission power.

This parameter is the transmission power of the primary CCPCH


WCEL PtxPrimaryCCPCH -50 100% -50 relative to the CPICH transmission power , one cells is having - 40 so
it's recommended to change it to - 50

The parameter defines the transmission power of the S-CCPCH


WCEL PtxSCCPCH1 0 100% 0 channel which carries PCH and FACHs, or alternatively only FACHs.

This is the transmission power of the S-CCPCH channel for standalone


WCEL PtxSCCPCH2 -50 100% -50 PCH.

This parameter defines the transmission power of the SCCPCH


WCEL PtxSCCPCH3 -20 100% -20 channel that carries only a FACH containing CCCH and a FACH
containing CTCH.

WCEL PtxPICH -8 100% -8 This is the transmission power of the PICH channel.

NSN – Mobinil propriety confidential data


- Power Control Parameters ( Cont. )
Deployed
% of cells
Object AbbreviatedName Default Values Comments
at Default
Range

This is the transmission power of one Acquisition Indicator (AI)


WCEL PtxAICH -8 100% -8 compared to CPICH power.

This parameter defines the transmission power of the E-DCH


WCEL PtxOffsetEAGCH 108 100% 108 Absolute Grant Channel. E-AGCH power is related to the
transmission power of the primary CPICH.

This parameter defines the transmission power of the E-DCH


WCEL PtxOffsetERGCH 84 100% 84 Relative Grant Channel. E-RGCH power is related to the
transmission power of the primary CPICH.

330,360,35 This is the transmission power of the primary common pilot


WCEL PtxPrimaryCPICH 330 93%
0,340 channel.

Defines the power offset for the TFCI symbols relative to the
WCEL PO1_15 8 100% 8 downlink transmission power of a Secondary CCPCH

NSN – Mobinil propriety confidential data


- Power Control Parameters ( Cont. )
Deployed
% of cells
Object AbbreviatedName Default Values Comments
at Default
Range

Defines the power offset for the TFCI symbols relative to the
WCEL PO1_30 12 100% 12 downlink transmission power of a Secondary CCPCH

Defines the power offset for the TFCI symbols relative to the
WCEL PO1_60 16 100% 16 downlink transmission power of a Secondary CCPCH

The number of Page Indicators that can be paged in one PICH radio
WCEL Pi_amount 2 100% 2 frame

The DRX cycle length used by UTRAN to count paging occasions for
WCEL UTRAN_DRX_length 5 100% 5 discontinuous reception

This UL required received C/I value is used by the UE to calculate


WCEL PRACHRequiredReceivedCI -25 0% -20 the initial output power on PRACH according to the Open loop
power control procedure, and the recommended is to be - 20

AICH transmission timing defines the delay between the reception


of a PRACH access slot including a correctly detected preamble and
WCEL AICHTraTime 0 100% 0 the transmission of the Acquisition Indicator in the AICH.3 Cells are
having 1 and their cell range is greater than 15000 ( If
AICHTraTime has value 0, maximum Cell range is 10km )

NSN – Mobinil propriety confidential data


- Power Control Parameters ( Cont. )
Deployed
% of cells
Object AbbreviatedName Default Values Comments
at Default
Range

The power offset between the last transmitted preamble and the
PowerOffsetLastPreamblePRACHmessa
WCEL 2 100% 2 control part of the PRACH message (added to the preamble
ge
power to receive the power of the message control part)

The power ramp step on PRACH preamble when no acquisition


WCEL PowerRampStepPRACHpreamble 2 0% 3 indicator (AI) is detected by the UE recomneded to leave it 3
since most delta is Open Areas

The maximum number of preambles allowed in one preamble


WCEL PRACH_preamble_retrans 8 100% 8 ramping cycle

Maximum number of RACH preamble cycles defines how many


times the PRACH pre-amble ramping procedure can be repeated
WCEL RACH_tx_Max 8 100% 8 before UE MAC reports a failure on RACH transmission to higher
layers

This parameter defines how many SCCPCHs are configured for


WCEL NbrOfSCCPCHs 1 100% 1 the cell. PCH load checked and it's enough to have one SCCPCH

Parameter defines, whether any such external device is used in


the BTS that the reference point of the TX characteristics or the
WCEL AC MHA 1 100% 1 RX characteristics is moved from the antenna connector of the
cabinet port to the far end antenna connector.

NSN – Mobinil propriety confidential data


- Power Control Parameters ( Cont. )

Deployed
% of cells at
Object AbbreviatedName Default Values Comments
Default
Range

The parameter defines the difference in the DL link loss in relation to


WCEL AC Cableloss 30 99.7% 30,40 the UL link loss when an external device is used in the BTS. Need to
change the from 40 to 30

The parameter defines the maximum transmission power level that


WCEL AC UEtxPowerMaxPRACH 21 0% 24 a UE can use on PRACH. Default value is 21 but It's recommended
to be 24

The parameter defines the maximum transmission power level that


WCEL AC UEtxPowerMaxPRACHConn 21 100% 21 a UE can use on PRACH.

NSN – Mobinil propriety confidential data


Radio Resource Management Audit

• Power, Load & Admission control


• Power Control
• Load Control
• Admission Control
• Handover Control
• Packet Scheduling
• HSDPA Parameters.
• HSUPA Parameters.

NSN – Mobinil propriety confidential data


Executive Summary

 Consistency check:

 NO any inconsistency check had been Found

NSN – Mobinil propriety confidential data


Radio Resource Management Audit :
Power , Load & Admission Control
- Load Control Parameters
% of
Deployed Values
Object Abbreviated Name Default cells at Comments
Range
Default

PrxNoiseMaxTuneAbsol The parameter sets absolute limit for uplink noise


RNC 255 0% 120
ute autotuning compared to PrxNoise value.

RACHloadIndicationPeri The parameter defines the reporting period of the PRACHs


WBTS 1 100% 1
od in a BTS.

The parameter defines the reporting period of the Radio


Resource Indication messages, which are used for cell
WBTS RRIndPeriod 40 0% 20
based load measurements. It's recommended to Keep it 20
for the whole network

DedicatedMeasReportP The parameter determines the reporting interval that Node


WBTS 5 100% 5
eriod B uses when it sends dedicated measurement reports.

The parameter determines the reporting interval which the


DediMeasRepPeriodPSd
WBTS 1 100% 1 Node B shall use when it sends dedicated measurement
ata
reports

The parameter determines the reporting interval which the


DediMeasRepPeriodCSd
WBTS 3 100% 3 Node B shall use when it sends dedicated measurement
ata
reports

NSN – Mobinil propriety confidential data


- Load Control Parameters ( Cont. )

% of Deployed
Abbreviated
Object Default cells at Values Comments
Name
Default Range

Defines the noise level in the BTS digital receiver when there is no
WCEL Prxnoise -1050 0.1% -1019,-1050 load (thermal noise + noise figure) , default value is -1050 , if the
other values aren't based on any measurements done before

PrxNoiseAutotunin The auto tuning algorithm of PrxNoise can be switched on or off. The
WCEL 1 100% 1
g current value means that the algorithm is on

The target for received total wideband interference power in a cell ,


WCEL PrxTarget 40 0% 200,220 default value will lead to AC rejections due to UL load recommended
to be 200 there no

The target value of the total received power (PrxTarget) can be


WCEL Prxoffset 10 0% 20 exceeded by the value of this parameter before the cell is considered
to be overloaded in uplink recommended to leave it 20

NSN – Mobinil propriety confidential data


- Load Control Parameters ( Cont. )

Deploye
% of
d
Object Abbreviated Name Default cells at Comments
Values
Default
Range

The target value of the total transmitted power (PtxTarget)


can be exceeded by the value of this parameter before the
WCEL Ptxoffset 10 2.1% 8,10 cell is considered to be overloaded in downlink , the
Current Value is 8 fro all Network we can make a trial to
change it

468,450,
WCEL Ptxtarget 400 0% This is the target value for total transmitted power ,
420,437

478,460, This parameter defines the maximum transmission power


WCEL Ptxcellmax 430 11.3%
430,447 of the cell.

NSN – Mobinil propriety confidential data


Radio Resource Management Audit

• Power, Load & Admission control


• Power Control
• Load Control
• Admission Control
• Handover Control
• Packet Scheduling
• HSDPA Parameters.
• HSUPA Parameters.

NSN – Mobinil propriety confidential data


Executive Summary

 Consistency check:

 No inconsistency were found

NSN – Mobinil propriety confidential data


Radio Resource Management Audit :
Power , Load & Admission Control
- Admission Control Parameters
% of
Deploye
Abbreviated cells at
Object Default d Values Comments
Name Defaul
Range
t

Defines the downlink power control range in relation to the maximum


allocated transmission power of the radio link , with the
CPICHtoRefRABOffset change also that the minimum power is
increased as well (as the minimum power is Max power – DL PC
RNC AC PCrangeDL 15 0% 20,22
Range) which might lead to the situation where too high powers are
allocated even in the good coverage conditions as a result power is
wasted so it's recommended to set the parameter value from 15 to
20 which is the current value

MaxNumberOf
Defines how many re-attempts the RNC shall perform when hunting
RNC AC ReAttemptsCo 2 100% 2
congested logical or hardware resources
ng

MaxFreezingTi This timer ensures that, once frozen, a BTS is not locked to frozen
RNC AC 30 100% 30
me state because a defrost command is missing or arrives too late

Parameter defines the maximum code channel output power for the
WBTS PtxDPCHMax -30 100% -30
power control dynamic range of BTS

NSN – Mobinil propriety confidential data


- Admission Control Parameters ( Cont. )
% of
cells Deploye
Abbreviated
Object Default at d Values Comments
Name
Defaul Range
t

Parameter defines the minimum code channel output power for the
WBTS PTxDPCHmin -28 100% -28
power control dynamic range of BTS

330,360,3
WCEL 330 93% This is the transmission power of the primary common pilot channel.
PtxPrimaryCPIC 50,340
H

WCEL UEtxPowerMaxDP
24 100% 24 Defines the maximum transmission power level a UE can use on DPCH
AC CH

The parameter defines the maximum transmission power level that a UE


WCEL UEtxPowerMaxPR
21 0% 24 can use on PRACH. Default value is 21 Keep the value for all the cells to
AC ACH
24

WCEL
PtxDLabsMax 370 1.5% 390,370 The planned maximum downlink transmission power of radio link
AC

WCEL 478,460,4 This parameter defines the maximum transmission power of the cell. The
PtxCellMax 430 11.3%
AC 30,447 following values showed good performance in Alexandria .

NSN – Mobinil propriety confidential data


- Admission Control Parameters ( Cont. )

% of
Deploy
cells
Objec Abbreviat ed
Default at Comments
t ed Name Values
Defau
Range
lt

Defines the offset of the primary CPICH transmission


power, and the maximum DL transmission power of the
reference service channel in DL power allocation. Default
value is 0 but it's recommended to change it to -20 , most
of the cells are having - 20 and it's recommended to
WCEL CPICHtoRef -20,20,-
20 2.1% change the parameter value from - 30 and 0 to - 20 for
AC RABOffset 30,-40
the remaining ( 91 cells ) because With high HSDPA
traffic the increased interference will decrease the EcNo
level, which could mean increased peak power for AMR,
thus max radio link power for AMR should be increased
also. recommended to Keep it Trail

Parameter defines the maximum code power of the radio


WCEL PtxPSstrea
370 100% 370 link for the real time services, when the CCTrCH includes
AC mAbsMax
a DCH of the PS streaming traffic class RAB.

NSN – Mobinil propriety confidential data


Radio Resource Management Audit

• Power, Load
• Admission control
• Handover Control
• Packet Scheduling
• HSDPA Parameters.
• HSUPA Parameters.

NSN – Mobinil propriety confidential data


Executive Summary
 Consistency check:

 Discrepancies were found for the following parameters and the sheet
attached includes the changes required for correction
 Some of the parameters are related to Load based HO causes which
aren’t activated so it isn’t important parameters.
• QqualMin
• LHOWinSizeONResRateSC
• LHOWinSizeONInterference
• LHOWinSizeOFFResRateSC
• LHOResRateSC
• LHOPwrOffsetUL
• LHOPwrOffsetDL
• LHONumbUEInterRAT
• LHOHystTimeResRateSC
NSN – Mobinil propriety confidential data
Executive Summary (Cont.)

• LHOHystTimeCapaReqRejRate
• LHOHardBlockingRatio
Handover Control
• LHODelayOFFResRateSC
• LHODelayOFFCapaReqRejRate
• LHOCapaReqRejRateUL
• LHOCapaReqRejRateDL

NSN – Mobinil propriety confidential data


Radio Resource Management Audit :
Handover Control
- Handover Control Parameters ( RNC , WCEL , WBTS )
% of
cells Deploye
Defa
Object Abbreviated Name at d Values Comment
ult
Defaul Range
t
UL quality derioration reporting threshold
RNC HCPC ULQualDetRepThreshold 1 0% 10
recomeded 10
This parameter defines whether or not compressed
RNC PS CMmasterSwitch 0 100% 0
mode is used on the system level.
Parameter controls, on the system level, whether
compressed mode by HLS ½ (signle frame) is
RNC PS HLSModeSelection 0 100% 0
allowed to use if possible or is HLS ¾ (double
frame) used instead.
This parameter activates/deactivates ISHO
RNC HCPC ISHOCancellation 0 0% 1 Cancellation at the RNC level.parameter set to 1 to
enable ISHO cancellation
This parameter specifies the maximum number of
RNC HCPC MaxNumISHOClPerAS 1 100% 1 ISHO Cancellations that are allowed for a
corresponding UE per Active Set.
The parameter defines the minimum required
WCEL QqualMin -18 100% -18 quality level in the cell (Ec/No). Cells which are
having -16 need to be changed to -18
The parameter defines the threshold for intra-
WCEL SintraSearch 5 100% 5 frequency measurements and for the HCS
measurement rules.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deployed
Object Abbreviated Name Default cells at Values Comment
Default Range

The parameter defines the threshold for inter-frequency measurements


WCEL SinterSearch 4 100% 4
and for the HCS measurement rules.

The parameter defines the RAT-specific threshold for inter-RAT


WCEL Ssearch_RAT 2 33.9% 1,2 measurement rules.Inter-RAT reselection starts from -16 Need to be
changed

This parameter is used for TDD and GSM cells, and for FDD cells when
WCEL Qhyst1 0 100% 0
cell selection and re-selection quality measure is set to CPICH RSCP.

Qhyst2 is used for FDD cells when cell selection and re-selection quality
WCEL Qhyst2 1 100% 1
measure is set to CPICH Ec/No.

This parameter defines whether service or load based handovers are


SLHOUseBackground
RNC 0 0% 1 performed for the background PS NRT data service. Parameter set to 1
PSNRTData
to enable load based HO for PS background

This parameter defines whether service or load based handovers are


SLHOUseConvCSSpe
RNC 0 0% 1 performed for the conversational CS speech service.Parameter set to 1
ech
to enable load based HO for CS Speech

SLHOUseConvPSRTD This parameter defines whether service or load based handovers are
RNC 0 100% 0
ata performed for the conversational PS RT data service.

SLHOUseConvPSSpee This parameter defines whether service or load based handovers are
RNC 0 100% 0
ch performed for the conversational PS speech service.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deploye
Object Abbreviated Name Default cells at d Values Comment
Default Range

SLHOprofileStreamP Preferred RAT or WCDMA layer for the streaming PS RT data service in
RNC 0 100% 0
SRTdata the service and load based handovers.

SLHOprofileInteracti Preferred RAT or WCDMA layer for the interactive PS NRT data service
RNC 0 0% 1
vePSNRTdata in the service and load based handovers.Prefered layer is GSM

Preferred RAT or WCDMA layer for the background PS NRT data


SLHOprofileBackgrou
RNC 0 0% 1 service in the service and load based handovers. Prefered layer is
ndPSNRTdata
GSM
WCEL HCS_PRIO 0 100% 0 This parameter defines the HCS priority level for a cell.

AdjiComLoadMeasD This parameter controls the activity of common load measurement of


ADJI 0 100% 0
RNCCellNCHO certain inter-frequency neighbour cell that is controlled by the DRNC.

Parameter defines whether a non-active load measurement of a


SLHOHandlingOfCell certain inter-frequency neighbour cell (controlled by SRNC or DRNC)
RNC 0 100% 0
LoadMeasNotAct blocks it from the set of cells that are used as neighbour cells in inter-
frequency service- and load-based handover procedure

This parameter defines the load threshold for the common load
NCHOThrComLoadM
RNC 70 100% 70 measurements of the inter-frequency neighbor cells that are
easDRNCCell
controlled by the DRNC.

Parameter defines the measurement hysteresis time for the common


NCHOHystComLoad
RNC 300 100% 300 load measurements of the inter-frequency neighbor cells that are
MeasDRNCCell
controlled by the DRNC.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
Deployed
% of cells
Object Abbreviated Name Default Values Comment
at Default
Range

Parameter defines the measurement filter coefficient for the


NCHOFiltercoeffCom
RNC 15 100% 15 common load measurements of the inter-frequency neighbour cells
LoadMeasDRNCCell
that are controlled by DRNC.

This parameter defines CPICH EcNo offset for the load and service
ADJI AdjiEcNoOffsetNCHO 12 100% 12
based handover procedure.

GSMcauseCPICHEcN The parameter indicates whether a handover to GSM caused by low


FMCG 0 10% 1,0
o measured absolute CPICH Ec/No of the serving cell is enabled.

This parameter indicates whether a handover to GSM caused by low


FMCG GSMcauseCPICHrscp 0 10% 1,0
measured absolute CPICH RSCP of the serving cell is enabled.

The parameter indicates whether a handover to GSM caused by


FMCG GSMcauseTxPwrUL 0 10% 1,0
high UE TX power level is enabled.

The parameter indicates whether a handover to GSM caused by


FMCG GSMcauseTxPwrDL 0 100% 0
high downlink DPCH TX power is enabled.

GSMcauseUplinkQu The parameter indicates whether a handover to GSM caused by bad


FMCG 0 85% 0,1
ality uplink DCH quality is enabled.

This parameter determines the minimum interval between an


GsmMinMeasInterva unsuccessful inter-RAT (GSM) measurement or handover procedure,
FMCG 2 100% 2
l and the following GSM measurement procedure related to the same
RRC connection.

The parameter controls the higher layer filtering of physical layer UE


GSMUETxPwrFilterC
FMCG 8 100% 8 TX power measurements before the event evaluation and
oeff
measurement reporting is performed by the UE.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deploye
Object Abbreviated Name Default cells at d Values Comment
Default Range

The parameter determines the UE TX power threshold for a CS voice


FMCG GSMUETxPwrThrAMR -3 85% -3,-12
connection. Need to Be cleared

The parameter determines the UE TX power threshold for a CS data


FMCG GSMUETxPwrThrCS -3 100% -3
connection.

GSMUETxPwrThrNrtP The parameter determines the UE TX power threshold for a non-real


FMCG -1 100% -1
S time PS data connection.

The parameter determines the UE TX power threshold for a real time


FMCG GSMUETxPwrThrRtPS -3 100% -3
PS data connection.

This parameter determines the time period during which the UE TX


GSMUETxPwrTimeHy
FMCG 11 100% 11 power must stay below the UE TX power threshold before the RNC
st
calls off the GSM measurements caused by the high UE TX power.

The parameter determines the downlink DPCH TX power threshold for


FMCG GSMDLTxPwrThrAMR -6 5% -1,-6 a CS voice connection. Not on default value but hard handover isn't
enabled for that cause

The parameter determines the downlink DPCH TX power threshold for


FMCG GSMDLTxPwrThrCS -6 100% -6
a CS data connection.

The parameter determines the downlink DPCH TX power threshold for


FMCG GSMDLTxPwrThrRtPS -6 100% -6
a real time PS data connection.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deployed
Object Abbreviated Name Default cells at Values Comment
Default Range

GSMDLTxPwrThrNrtP The parameter determines the downlink DPCH TX power threshold for a
FMCG -2 100% -2
S non-real time PS data connection.

This parameter determines the measurement reporting interval for


FMCG GSMMeasRepInterval 2 100% 2
periodical inter-RAT (GSM) measurements.

The parameter determines the number of periodical inter-RAT (GSM)


GsmNcellSearchPerio measurement reports, starting from the first report after the
FMCG 0 65% 0,2
d measurement setup, during which a handover to GSM is not possible.
Need to Be Cleared

The parameter determines the maximum number of periodical inter-


RAT (GSM) measurement reports (maximum size of the sliding
FMCG GSMMeasAveWindow 6 100% 6
averaging window) from which the RNC calculates the averaged GSM
RSSI values for the handover decision algorithm.

The maximum number of periodical inter-RAT (GSM) measurement


FMCG GSMMaxMeasPeriod 6 80% 6,20,12 reports determines the maximum allowed duration of the GSM
measurement. Need to be cleared

The minimum interval between a successful service or load based


inter-RAT handover from GSM to UTRAN and the following service or
FMCG GsmMinSLHOInterval 30 100% 30
load based inter-RAT handover attempt back to GSM related to the
same RRC connection.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
Deploye
% of
Abbreviated d
Object Default cells at Comment
Name Values
Default
Range

The parameter indicates whether an inter-frequency handover


IFHOcauseCPICHEc
FMCI 0 57.14% 0,1 caused by low measured absolute CPICH Ec/No of the serving
No
cell is enabled.

The parameter indicates whether an inter-frequency handover


IFHOcauseCPICHrs
FMCI 0 57.14% 0,1 caused by low measured absolute CPICH RSCP of the serving
cp
cell is enabled. Cause is active on F2 cells only

IFHOcauseTxPwrU The parameter indicates whether an inter-frequency handover


FMCI 0 100% 0
L caused by high UE TX power level is enabled.

IFHOcauseTxPwrD The parameter indicates whether an inter-frequency handover


FMCI 0 100% 0
L caused by high downlink DPCH TX power is enabled.

IFHOcauseUplinkQ This parameter indicates whether an inter-frequency handover


FMCI 0 100% 0
uality caused by bad uplink DCH quality is enabled.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
Deploy
% of
Abbreviated ed
Object Default cells at Comment
Name Values
Default
Range
InterfreqDLTxPwrT The parameter determines the downlink DPCH TX power
FMCI -6 100% -6
hrCS threshold for a CS data connection.

InterfreqDLTxPwrT This parameter determines the downlink DPCH TX power


FMCI -6 100% -6
hrRtPS threshold for a real time PS data connection.

InterfreqDLTxPwrT This parameter determines the downlink DPCH TX power


FMCI -2 100% -2
hrNrtPS threshold for a non-real time PS data connection.

InterFreqMeasRepI This parameter determines the measurement reporting


FMCI 2 100% 2
nterval interval for periodical inter-frequency measurements.

This parameter determines the number of periodical inter-


InterFreqNcellSear frequency measurement reports, starting from the first
FMCI 0 100% 0
chPeriod report after the measurement setup, during which an inter-
frequency handover is not allowed.

The parameter determines the maximum number of


periodical inter-frequency measurement reports from where
InterFreqMeasAve
FMCI 6 100% 6 the RNC calculates the averaged CPICH Ec/No and RSCP
Window
values for the decision algorithm of the inter-frequency
handover.

The maximum number of periodical inter-frequency


InterFreqMaxMeas
FMCI 6 100% 6 measurement reports determines the maximum allowed
Period
duration of the inter-frequency measurement.
The minimum interval between a successful service or load
InterFreqMinSLHOI based inter-frequency handover and the following service or
FMCI 30 100% 30
nterval load based handover attempt related to the same RRC
connection.
NSN – Mobinil propriety confidential data
- Handover Control Parameters ( Cont. )
Deploy
% of
Abbreviated ed
Object Default cells at Comment
Name Values
Default
Range

This parameter determines the maximum number of cells


FMCS MaxActiveSetSize 3 100% 3
which can participate in a soft/softer handover

In the CELL_DCH state the UE physical layer measurement


period for intra-frequency CPICH Ec/No measurements is 200
EcNoFilterCoefficie ms. The Filter Coefficient parameter controls the higher layer
FMCS 3 100% 3
nt filtering of physical layer CPICH Ec/No measurements before
the event evaluation and measurement reporting is
performed by the UE.

The parameter is used to weight either the measurement


ActiveSetWeightin result of the best active set cell (M_best) or the sum of
FMCS 0 100% 0
gCoefficient measurement results of all active set cells (M_sum) when the
UE calculates the reporting range for the events 1A and 1B.

Addition Window determines the relative threshold (A_Win)


FMCS AdditionWindow 8 10.48% 6,8,10
used by the UE to calculate the reporting range of event 1A

Addition Time determines the period of time between the


FMCS AdditionTime 6 95.16% 6,11,3 detection of the event 1A and the sending of the
Measurement Report. Need to Be cleared

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deploye
Object Abbreviated Name Default cells at d Values Comment
Default Range
Addition Reporting Interval determines the interval of periodical
AdditionReportingInt
FMCS 2 100% 2 measurement reporting when such reporting is triggered by the
erval
event 1A.
Drop Window determines the relative threshold (D_Win) which is
FMCS DropWindow 12 89.52% 12,14
used by the UE to calculate the reporting range of event 1B Trail

Drop Time determines the period of time between the detection of


FMCS DropTime 12 93.55% 12,10,11 the event 1B and the sending of the Measurement Report. Need to
be Cleared

The parameter determines the margin by which the CPICH Ec/No


measurement result of the monitored cell must exceed the CPICH
ReplacementWindo
FMCS 4 62.1% 8,4 Ec/No measurement result of the an active set cell before the UE can
w
send the event 1C triggered Measurement Report to the RNC Need
to be Cleared

Replacement Time determines the period of time between the


FMCS ReplacementTime 6 99.19% 6,11 detection of the event 1C and the sending of the Measurement
Report. Need to be Cleared

ReplacementReporti This parameter determines the interval of periodical measurement


FMCS 2 100% 2
ngInterval reports when such reporting is triggered by the event 1C.

The Filter Coefficient parameter controls the higher layer filtering of


FMCS EcNoFilterCoefficient 3 100% 3 physical layer CPICH Ec/No measurements before the event
evaluation and measurement reporting is performed by the UE.

-9,-10,-
17,-13,- The parameter determines the absolute CPICH Ec/No threshold
FMCS HHoEcNoCancel -9 34.68% 12,-7,- which is used by the UE to trigger the reporting event 1E. Need to
15,-11,- be Cleared
16,-8

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
Deployed
% of cells
Object Abbreviated Name Default Values Comment
at Default
Range
The parameter determines the time period during which the CPICH Ec/No of
FMCS HHoEcNoCancelTime 13 79.84% 13,11,12 the active set cell must stay better than the threshold HHoEcNoCancel before
the UE can trigger the reporting event 1E. Need to be Cleared
-13,-12,-
20,-11,- The parameter determines the absolute CPICH Ec/No threshold which is used
FMCS HHoEcNoThreshold -12 55.65%
16,-14,- by the UE to trigger the reporting event 1F. OK
10,-18
The parameter HHoEcNoTimeHysteresis determines the time period during
HHoEcNoTimeHysteresi 6,11,13,12, which the CPICH Ec/No of the active set cell must stay worse than the
FMCS 6 9.68%
s 8 threshold HHoEcNoThreshold before the UE can trigger the reporting event
1F. Need to Be Cleared

-102,-112,-
99,-104,-
106,-100,-
The parameter determines the absolute CPICH RSCP threshold which is used
FMCS HHoRscpCancel -102 37.1% 97,-109,-
by the UE to trigger the reporting event 1E. Need to Be Cleared
107,-95,-
92,-110,-
105

The parameter determines the time period during which the CPICH RSCP of
FMCS HHoRscpCancelTime 13 95.97% 13,12 the active set cell must stay better than the threshold HHoRscpCancel before
the UE can trigger the reporting event 1E. Need to Be Cleared

-105,-115,-
102,-107,-
The parameter determines the absolute CPICH RSCP threshold which is used
FMCS HHoRscpThreshold -105 37.1% 109,-103,-
by the UE to trigger the reporting event 1F. Need to Be Cleared
100,-112,-
110,-95

The parameter HHoRscpTimeHysteresis determines the time period during


HHoRscpTimeHysteresi which the CPICH RSCP of the active set cell must stay worse than the
FMCS 6 9.68% 6,11,13,12
s threshold HHoRscpThreshold before the UE can trigger the reporting event 1F.
Need to Be Cleared

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deploye
Object Abbreviated Name Default cells at d Values Comment
Default Range

This parameter indicates whether a RRC connection release


(excluding emergency calls) is required in order to avoid excessive
HOPS EnableRRCRelease 0 100% 0
uplink interference due to non-optimum fast closed loop power
control.

This parameter determines the maximum allowed difference


ReleaseMarginAvera between the averaged CPICH Ec/No of the neighbouring cell and the
HOPS 25 100% 25
geEcNo averaged CPICH Ec/No of the best active cell in situations when the
RNC is not able to perform a soft handover between these cells

This parameter determines the maximum allowed difference


ReleaseMarginPeakE between the CPICH Ec/No of the neighbour cell and the CPICH Ec/No
HOPS 7 100% 7
cNo of the best active cell in situations when the RNC is not able to
perform a soft handover between these cells

The parameter is used in the cell re-selection and ranking between


HOPS AdjsQoffset1 0 92.86% 0,1
WCDMA cells. Trail

The parameter is used in the cell re-selection and ranking between


HOPS AdjsQoffset2 0 64.29% 0,3,-3,1,2
WCDMA cells OPtimized

The parameter determines the minimum required CPICH Ec/No level


-17,-18,-
HOPS AdjsQqualmin -18 7.14% which the measurement result of the neighbouring cell must exceed
15
before the cell re-selection is possible Optimized

The parameter determines the minimum required CPICH RSCP level


HOPS AdjsQrxlevMin -58 92.86% -58,-53 which the measurement result of the neighbouring cell must exceed
before the cell re-selection is possible OPtimized

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deploye
Object Abbreviated Name Default cells at d Values Comment
Default Range

This parameter determines the minimum required CPICH RSCP level


which the averaged measurement result of the best inter-frequency
HOPI AdjiMinRSCP 16 100% 16
neighbour cell must exceed before the quality reason inter-frequency
handover is possible.

Determines the margin by which the averaged CPICH Ec/No


measurement result of best inter-frequency neighbour cell must
HOPI AdjiEcNoMargin 2 100% 2
exceed the averaged CPICH Ec/No measurement result of best active
set cell before quality reason inter-frequency handover is possible.

This parameter determines the minimum required CPICH Ec/No level


which the averaged measurement result of the best inter-frequency
HOPI AdjiMinEcNo 23 100% 23
neighbour cell must exceed before the coverage reason inter-
frequency handover is possible.

This parameter determines the margin by which the averaged


propagation loss of the best active set cell must exceed the
HOPI AdjiPlossMargin 2 100% 2
averaged propagation loss of the best inter-frequency neighbour cell
before the coverage reason inter-frequency handover is possible.

This parameter is used in the cell re-selection and ranking between


HOPI AdjiQoffset1 0 100% 0
WCDMA cells.

NSN – Mobinil propriety confidential data


- Handover Control Parameters ( Cont. )
% of Deploye
Object Abbreviated Name Default cells at d Values Comment
Default Range

10,25,60, This parameter determines the minimum required GSM RSSI level
15,63,13, which the averaged RSSI value of the GSM neighbour cell must
HOPG AdjgRxLevMinHO 15 25%
7,20,0,35, exceed before the coverage (or quality) reason handover to GSM is
30,5 possible. Optimized

The priority level of the GSM neighbour cell is controlled by this


HOPG AdjgPriorityCoverage 0 95% 0,7,4 parameter. The range of the parameter varies from zero to 7. Zero is
the lowest and 7 the highest priority level. Optimized

The parameter is used in the cell re-selection and ranking between


HOPG AdjgQoffset1 0 100% 0
WCDMA and GSM cells

The parameter determines the minimum required RSSI level which


-48,-46,-
HOPG AdjgQrxlevMin -51 12.5% the measurement result of the GSM neighbour cell must exceed
51
before the cell re-selection is possible OPtimized

AdjgPenaltyTimeNCH Parameter defines penalty time for GSM neighbour cell which has
HOPG 10 92.5% 10,20
O rejected resource request of handover attempt. Need to Be cleared

-100,-50,- The minimum required GSM RSSI level to make service or load reason
HOPG AdjgMinRxLevNCHO -95 17.5%
95,-47 handover to GSM possible need to Be cleraed

NSN – Mobinil propriety confidential data


THANK YOU

Company confidential – for internal use only


41 © Nokia Siemens Networks

You might also like