You are on page 1of 2

Total No. of Questions : 6] SEAT No.

P5803 [Total No. of Pages : 2


TE/Insem./Oct.-103

8
1:4
T.E. (Civil)

1:0
STRUCTURAL DESIGN - I

81
8/2 1
(2015 Pattern) (Semester - I)

9
01
8 1 30
.23 01
Time : 1½ Hours] [Max. Marks : 30
3/0
Instructions to the candidates :
8.2 G
P

1) Answer Q.1 or Q.2, Q.3 or Q.4, Q.5 or Q.6.


.24 CE

2) Neat sketches should be drawn wherever necessary.


16

3) Figures to the right indicate full marks.


4) Take Fe 410 grade of steel.

8
1:4
5) Take ultimate stress in bolt, fub = 400 N/mm2.
49

1:0
6) Assume Suitable data, if necessary.
7) Use of electronic pocket calculator, IS: 800-2007 and steel table allowed.
81
91
8) Use of cell phone is prohibited in the examination hall.
01
30
8/2
01
3/0

Q1) a) State and explain type of steel structures with sketches. [4]
GP
81

b) A tension member of roof truss consists of 2 - ISA 90 × 90 × 6 @ 8.2 kg/m


.23
CE

which is connected to 8 mm thick gusset plate by bolts. Design connection


16

and draw the sketch. [6]


8.2

OR 8
.24

1:4

Q2) a) State and explain classification of hot rolled steel section with stress
49

1:0

diagram. [4]
81
91

b) Determine design tensile strength due to yielding and rupture of 2-ISA


01
30

90 × 90 × 6@8.2 kg/m which are connected to back to back on opposite


8/2

side of gusset plate by 4 bolts of 20 mm dia. [6]


01
3/0
GP
81
.23

Q3) A top chord member 2.2 m long of roof truss subjected to factor compressive
CE

force 250 kN and tensile force 100 kN respectively. Design section using two
16

ISA on both side of gusset plate and the connection. [10]


8.2
.24

OR
49

P.T.O.
Q4) A column 9 m long consisting of 2-ISMC300@ 35.8 kg/m spaced at 180 mm
back to back. The column is restrained in translation but not is rotation at
both ends. Determine design compressive strength of the column and design

8
batten system with bolted connection. [10]

1:4
1:0
81
8/2 1
Q5) Design a gusseted base for a column ISHB 350@ 72.4 kg/m subjected to

9
01
factored load of 1200 kN. The column is supported on M20 grade concrete
pedestal.
8 1 30 [10]
.23 01
3/0 OR
8.2 G
P

Q6) Check the adequacy of ISHB 450 @ 87.2 kg/m to carry a factored compressive
.24 CE

load of 750 kN at an eccentricity of 270 mm about major axis. The effective


16

length of column is 5 m and compression flanges are laterally unsupported.


Consider only section strength. [10]

8
1:4
eee
49

1:0
81
91
01
30
8/2
01
3/0
GP
81
.23
CE
16
8.2

8
.24

1:4
49

1:0
81
91
01
30
8/2
01
3/0
GP
81
.23
CE
16
8.2
.24
49

TE/Insem./Oct.-103 2

You might also like