You are on page 1of 4

Roll No. ......................

Total Pages : 4
BT-6/M-21 46188
DESIGN OF STEEL STRUCTURES-II
Paper–CE-302A

Time : Three Hours] [Maximum Marks : 75

Note : All questions carry equal marks. Attempt any five


questions by selecting at least one question from each
unit. If necessary, assume suitable data and specify the
same. Figures to the right indicate full marks. All relevant
codes are allowed.

UNIT–I
1. (a) Determine shape factor for symmetric I-section. Also,
calculate moment of resistance of the cross section
corresponding to the strain distribution specified.
Section Details Strain Distribution
Flange c/s : 300 mm × 20 mm Max. Strain : 0.003
Web c/s : 400 × 20 mm Yield Strain : 0.0012
(b) Carryout plastic analysis of frame structure shown in
Fig. 1. Load Factor = 1.5.
20 kN/m

C Mp D

3m 0.75 Mp 3m
0.75 Mp

40 kN B E

2m
A
5m

Fig. 1.
46188//KD/1269 [P.T.O.
2. Analyse and design three span continuous beam
supporting UDL of 50 kN/m by providing economical cross
section. Also apply the necessary checks.

Wu = 50 kN/m
A D
B C
6m 4m 4m

Fig. 2.

UNIT–II

3. Design an elevated cylindrical tank of 1,00,000 litres


capacity. Also, design the ring beam (Fig. 3).

COEFFICIENTS FOR RING BEAM

n Load on Max. C0 Cc Ct ft
each Shear
column
4 W/4 W/8 -0.03415 +0.01762 0.00530 19°12'
6 W/6 W/12 -0.01482 +0.00751 0.00151 12°44'
8 W/8 W/16 -0.00827 +0.00416 0.00063 9°33'
10 W/12 W/24 –0.00365 +0.00190 0.000185 6°21'

Fig. 3.

4. Design a self-supporting steel chimney of height 60 m,


located at the outskirts of Kurukshetra with diameter of the
cylindrical part as 2 m. The thickness of refractory brick
lining 100 mm with density of 20 kN/m3 is supported by
stack throughout the height. Design of the body of chimney
with base plate is expected.

46188//KD/1269 2
UNIT–III

5. (a) Enlist the advantages of cold rolled sections as


compared to their hot rolled counterparts.
(b) Determine the safe axial load carrying capacity of the
column section shown in Fig. 4. The effective length
of the column is 3 m. The yield strength of steel is
280 MPa.

Fig. 4.

6. (a) List the types of communication and electricity


transmission towers and explain various types of load
acting on transmission line towers.
(b) Describe the complete procedure for the analysis and
design of foundation for towers.

UNIT–IV

7. Design a purlin, supporting galvanised iron sheeting (150


N/m2 dead load) of an industrial building located in Delhi
having span of 20 m and length of 50 m. The terrain is an
open industrial area. Building is class B building with a clear
height of 8 m at the eaves.

46188//KD/1269 3 [P.T.O.
8. Deign a beam column subjected to a factored axial load of
400 kN and a factored bending moment of 60 kNm at the
fixed end. The other end of the beam column is hinged. The
unsupported length of the beam column is 4 m.

46188//KD/1269 4