Professional Documents
Culture Documents
500
499.79
427.120534
426.570765
http://www.bgicrew.com/
500 САНКТ-ПЕТЕРБУРГ
493.287574 Владимирский пр., д. 23, лит. А,
412.783042 “Регент холл”, 5-й этаж,
412.240426 г. Санкт-Петербург 191002 Россия
? E-mail : crew.spb@baltic-crew.com
?
Density at 15 ˚C
Den1 Den2
0.872 0.873 0.874
0.9931 0.99315 0.9932
0.99306 0.99309 0.99312
0.9930 0.993 0.9930
Скорость налива в танк для электростатических жидкостей
Диам.трубы= 300 мм
1 м/с 7 м/с
Скорость налива в пределах: 254.5 1781.3
Temp. before 25 oC
Temp. after: 50 oC
Difference: 18.57 m3
Volume after 1018.57 m3
t 60 EXP [ 60 t (1 0 .8 60 t )]
PAGE X-6
5B VOLUME II GENERALIZED PRODUCTS CORRECTION OF OBSERVED API GRAVITY TO API GRAVITY A
5B CONVERT API GRAVITY TO DENSITY:
141.5 * 999.012 ρt = density at temperature t RANGE
t API = observed API gravity ˚API
131.5 API
999,012 = density of water at 60˚F, Kg/m3 0…40
40…50
K0 K1
60 50…85
602 60
VCF EXP[ 60 t (1 0.8 60 t )]
t 60 EXP [ 60 t (1 0 .8 60 t )]
PAGE X-36
6A VOLUME I GENERALIZED CRUDE OILS CORRECTION OF VOLUME TO 60°F AGAINST API GRAVITY A
6A VCF EXP[ 60 t (1 0.8 60 t )]
WHERE ∆t = t - 60 (˚F) RANGE
˚API
K0 K1
60 0…40
602 60 40…50
50…100
141 . 5 * 999 . 012 999,012 = density of water at 60˚F, Kg/m3
60
131 . 5 API 60 PAGE X-91
6B VOLUME II GENERALIZED PRODUCTS CORRECTION OFVOLUME TO 60°F AGAINST API GRAVITY AT
6B VCF EXP[ 60 t (1 0.8 60 t )]
WHERE ∆t = t - 60 (˚F) RANGE
K0 K1 K 0 K 1 60 B ˚API
60 60 A 0…40
602 60 602 60
2 40…50
60
50…85
141 . 5 * 999 . 012
60 999,012 = density of water at 60˚F, Kg/m3
131 . 5 API 60
PAGE X-112
6C VOLUME III VOLUME CORRECTION FACTORS FOR INDIVIDUAL AND SPECIAL APPLICATIONS VOLUM
6C VCF EXP[ 60 t (1 0.8 60 t )] RANGE
WHERE ∆t = t - 60 (˚F) α * 106
α60 = coefficient of thermal expansion PAGE X-135 270…510
510…530
530…930
23A VOLUME IV GENERALIZED CRUDE OILS CORRECTION OF OBSERVED RELATIVE DENSITY TO RELAT
23A DENSITY ρt at temperature t:
ρt=relative density*999,012 999,012 = density of water at 60˚F, Kg/m3 RANGE
REL.DENSITY
K0 K1
60 0,8255…1,076
602 60 0,78…0,825
0,611…0,7795
VCF EXP[ 60 t (1 0.8 60 t )]
t 60 EXP [ 60 t (1 0 .8 60 t )]
WHERE ∆t = t - 60 (˚F) PAGE X-151
t 60 EXP [ 60 t (1 0 .8 60 t )]
WHERE ∆t = t - 60 (˚F) PAGE X-184
24A VOLUME IV GENERALIZED CRUDE OILS CORRECTION OF VOLUME TO 60°F AGAINST RELATIVE DEN
24A VCF EXP[ 60 t (1 0.8 60 t )]
WHERE ∆t = t - 60 (˚F) RANGE
REL.DENSITY
K0 K1
60 0,8255…1,076
602 60 0,78…0,825
WHERE ρ60=relative density60/60˚F*999,012 PAGE X-223 0,611…0,7795
24B VOLUME V GENERALIZED PRODUCTS CORRECTION OF VOLUME TO 60°F AGAINST RELATIVE DENS
24B VCF EXP[ 60 t (1 0.8 60 t )] K 0 K 1 60
WHERE ∆t = t - 60 (˚F) 60 RANGE
K0 K1 602 REL.DENSITY
60 OR B 0,8255…1,076
60
2
60 60 A 0,78…0,825
WHERE ρ60=relative density60/60˚F*999,012 602 0,6535…0,7795
999,012 = density of water at 60˚F, Kg/m3 PAGE X-243
24C VOLUME VI VOLUME CORRECTION FACTORS FOR INDIVIDUAL AND SPECIAL APPLICATIONS VOLUM
24C VCF EXP[ 60 t (1 0.8 60 t )] RANGE
WHERE ∆t = t - 60 (˚F) α * 106
α60 = coefficient of thermal expansion PAGE X-266 270…510
510…530
530…930
53A VOLUME VII GENERALIZED CRUDE OILS CORRECTION OF OBSERVED DENSITY TO DENSITY AT 15°C
53A K0 K1
15 RANGE
15
2
15
K0 K1
15
152 15 DENSITY
VCF EXP [ 15 t (1 0 . 8 15 t )] 610,5…778,5
t 15 EXP [ 15 t (1 0 . 8 15 t )] 779…824
824,5…1075
where ρ15 = density at the base temperature
∆t = t - 15 (˚C) PAGE X-283
53B VOLUME VIII GENERALIZED PRODUCTS CORRECTION OF OBSERVED DENSITY TO DENSITY AT 15°C
53B K0 K1
15 RANGE
152 15 DENSITY
VCF EXP [ 15 t (1 0 . 8 15 t )] 653…778,5
779…824
t 15 EXP [ 15 t (1 0 .8 15 t )] 824,5…1075
where ρ15 = density at the base temperature
∆t = t - 15 (˚C) PAGE X-311
54A VOLUME VII GENERALIZED CRUDE OILS CORRECTION OF VOLUME TO 15°C AGAINST DENSITY AT 1
54A VCF EXP [ 15 t (1 0 .8 15 t )] RANGE
where ∆t = t - 15 (˚C) DENSITY
610,5…778,5
K0 K1
15 779…824
152 15 PAGE X-351 824,5…1075
54B VOLUME VIII GENERALIZED PRODUCTS CORRECTION OF VOLUME TO 15°C AGAINST DENSITY AT 15
54B VCF EXP [ 15 t (1 0 .8 15 t )] RANGE
where ∆t = t - 15 (˚C)
K 0 K 1 15 B DENSITY
A
K0 K 1 15 152
15
152
653…778
15 2 778,5…824
15 15 PAGE X-371 824,5…1075
54C VOLUME IX VOLUME CORRECTION FACTORS FOR INDIVIDUAL AND SPECIAL APPLICATIONS VOLUM
54C VCF EXP [ 15 t (1 0 .8 15 t )] RANGE
where ∆t = t - 15 (˚C) α * 106
K0 K1 486…918
15 918…954
152 15 PAGE X-393 954…1674
RANGE
˚F
0…300
0…250
0…200
RANGE
˚F
0…300
0…250
0…200
RANGE
˚F
0…300
0…250
0…200
RANGE
˚F
0…300
0…250
0…200
RANGE
REL.DENSITY ˚F
0,8255…1,076 0…300
0,78…0,825 0…250
0,611…0,7795 0…200
RANGE
REL.DENSITY ˚F
0,8255…1,076 0…300
0,78…0,825 0…250
0,6535…0,7795 0…200
RANGE
REL.DENSITY ˚F
0,8255…1,076 0…300
0,78…0,825 0…250
0,611…0,7795 0…200
RANGE
REL.DENSITY ˚F
0,8255…1,076 0…300
0,78…0,825 0…250
0,6535…0,7795 0…200
RANGE
DENSITY ˚C
610,5…778,5 -18…95
779…824 -18…125
824,5…1075 -18…150
RANGE
DENSITY ˚C
653…778,5 -18…90
779…824 -18…125
824,5…1075 -18…150
IAL APPLICATIONS VOLUME CORRECTION TO 15°C AGAINST THERMAL EXPANSION COEFFICIENTS AT 15°C
RANGE
˚C
-18…150
-18…125
-18…95
CONSTANTS
1. CRUDE OILS
2.PRODUCTS
(KG/M3)2/˚F
(KG/M3)2/˚F
(KG/M3)2/˚F
(KG/M3)2/˚F
(KG/M3)2/˚F
(KG/M3)2/˚F
(KG/M3)2/˚C
(KG/M3)2/˚C
(KG/M3)2/˚C
(KG/M3)2/˚C
Examples
5A CRUDE OILS 5B OIL PRODUCTS
API GRAVITY AT OBSERVED TEMPERATURE API GRAVITY AT OBSERVED TEMPERATURE
35 35.5 36 36.5 37 37.5 5 5.5 4.6 6.5 7 7.5
TEMP ˚F CORRESPONDING API GRAVITY AT 60˚F TEMP ˚F CORRESPONDING API GRAVITY AT 60˚F
195 25.7 26.1 26.5 26.9 27.3 27.8 90 3.6 4.1 4.6 5.1 5.6 6
195.5 25.6 26.1 26.5 26.9 27.3 27.7 90.5 3.6 4.1 4.6 5 5.5 6
196 25.6 26 26.4 26.9 27.3 27.7 91 3.6 4 4.5 5 5.5 6
196.5 25.6 26 26.4 26.8 27.2 27.7 91.5 3.5 4 4.5 5 5.5 6
197 25.5 26 26.4 26.8 27.2 27.6 92 3.5 4 4.5 5 5.5 5.9
197.5 25.5 25.9 26.3 26.8 27.2 27.6 92.5 3.5 4 4.5 4.9 5.4 5.9
VCF calculation
Density @ 15/vac= 0.8368 Density @ Corresponding Mass 5983.45
Actual temp= 31.00 actual temp dcc (approximate) Volume
VCF Table 54A= 0.9859 0.8250 0.00074 7252.65
Table 54B= 0.9864 0.8254 0.00071 7248.97
Table 54D= 0.9880 0.8268 0.00063 7237.24
User info
Density @ 15/vac= 836.8 General formula:
Actual temp= 31.0 VCF=exp(b) and : a=(K0+K1xDensity @ 15/vac)/(Density @ 15/vac^2)
diff temp= 16.0 b=-a x diff temp x (1+0,8 x a x diff temp)
diff temp=actual temp-15
Formula for Table 54B and 770 <= Dens @ 15/vac < 778:
VCF=exp(d) and : c=-0,0033612+2680,32/(Density @ 15/vac^2)
d=-c x diff temp x (1+ 0,8 x c x diff temp)
Table 54A
K0= 613.97226 a= 0.00088 VCF= 0.9859
K1= 0.00000 b= -0.01419
Table 54D
K0= 0.00000 a= 0.00075 VCF= 0.9880
K1= 0.62780 b= -0.01212
Page 21
VCF
ac)/(Density @ 15/vac^2)
a x diff temp)
Page 22
Nhiệt độ Tỷ trọng D15