You are on page 1of 15

Split Floor-Standing Air Conditioner

USER'S MANUAL
GL17Eng
Please read the user's manual carefully before using the product
Foreword
Thank you for choosing our company products!
Air conditioning facilities are valuable products. In order to protect your legitimate rights and
interests, please make sure that the installations are done by professional technicians. This Manual
is a general-purpose version for the split floor-standing air conditioning systems manufactured by
our Co., the one that you have chosen might be a little different in appearance from the ones
described in this Manual. But these differences will not have any impacts upon your operation and
use of the system.
Please read the Manual carefully before you operate the system and check to see if the model is
identical to the one you have purchased. Keep this Manual properly in case you might refer to it in
the future.
Addition to the user manual:
The appliance is not intended for use by young children or infirm persons without supervision;
Young children should be supervised to ensure that they do not play with the appliance.

CONTENTS
Instructions to Users 1
Names and Functions of Various Parts 2
Use of Control Panel 5
Use of remote controller 6
Methods of Maintenance 11
Phenomena Diagnosis and Treatment 12
*INSTUCTIONS TO USERS* USER'S MANUAL
Split Floor-Standing Air Conditioner

Please read the Manual carefully before using the air conditioner so as to ensure the normal operations of the units.

Do not open the return-air grids of the Do not put the sticks or other similar Do not place insecticides, paints or
indoor unit during operations. objects into the air inlet and outlet. other inflammables near the inlet or
outlet; do not spray such articles directly
against the units.
Dangerous!

I do the
spraying!

I dodge!

Operate the machine only under the The grounding terminal of the units must When doing the cleaning of the machine,
nominated voltage and frequency and be well connected to the grounding of the do not splash water to the units.
with corresponding protective devices. power source.
NO!
Copper
wire

Never use copper wires to substitute the


fuses, which might lead to operational It might result in faulty operations or
faults or fire hazards. electric shocks and other hazards.

Do not block the air inlet and outlet of Re-start the operation after power failure Non-operation for long time
the indoor or outdoor units so as to avoid
possible negative impacts upon the
machine performances or hazards.
MODE

Indoor unit

Air delivery
blocked

When the power supply is resumed, the air conditioner If the machine is not in use for long time,
will automatically enter the standby mode. Press the the power source should be disconnected
On/Off button to restart the operation. for the sake of safety and energy-saving.
Air inlet
blocked In the case that the breaker is frequently When you restart the operation after a
disconnected, you should stop the long period of non-operation, you should
operation of the machine and contact carefully check the air conditioner and
the dealer or our Co. authorized the wire connection.
maintenance shop.

Outdoor unit
S K
Air outlet
blocked Power leakage
protection
switch

If the electric wires are damaged or need to be


replaced due to other reasons, please ask our Co.
after-sale service person or the professional
technicians in the authorized maintenance shops
to do the replacement so as to avoid possible electric
shock, overheating, fire hazards or other accidents.

1
USER'S MANUAL *NAMES AND FUNCTIONS OF VARIOUS PARTS*
Split Floor-Standing Air Conditioner

Indoor Unit

Up/down air direction guides


For adjusting the vertical air delivery
directions

Left/right air swinging fins


For adjusting horizontal air delivery
directions

Air outlet

Control panel

Air filter grids


For air inlet from the room air

Air filter screen


For filtering dust and filth in the air

Outdoor Units

Air inlet
Air inlet

Air inlet

Air inlet

Air outlet
Air outlet

Features and appearance will vary.All the figure give a demonstration to introduce the function.

2
USER'S MANUAL
Split Floor-Standing Air Conditioner

Operation Panel

(1)
Dehumidifying
operation display
Refrigerating
Operation Display
Heating (ventilating) operation display

Defrosting Operation
Display

Room set
temperature and Sleeping operation display
failure code display

Timing Display
Display lock-up function

Display sign of fan Wind speed operation(swinging wind)


display
one bright fan blade indicates low wind speed,
two bright fan blade indicates middle wind speed,
three bright fan blade indicates high wind speed,
swinging fan blade indicates winging wind.

SLEEPING KEY
Press the key to choose
TIMING KEY
sleeping mode,the AC will
To press timing key to set operate with low wind
turning on time,turning off speed and automatically
time and to cancel timing, turns off after 8 hours,
the time range is 1-12 Press the key once again
hours. to cancel sleeping mode.

SWINGING WIND TEMPERATURE+ KEY


SELECTION KEY Press the key once to
To choose different wind increase the set
types of swinging windor temperature by 10C,the
set wind by pressing this highest temperature is
key. 290C.

WIND SPEED TEMPERATURE- KEY


SELECTION KEY Press the key once to
Press the key to choose reduce the set temperature
the wind speed and the by 10C,the lowest
wind speed changes in the
temperature is 180C.
following order with each
press:high,middle,low.

MODE SELECTION KEY TURN ON/OFF KEY


MODE
Press the key to choose Press the key to turn on or
operation modes of turn off the AC unit.
refrigerating,
dehumidifying,heating (or
ventilating for refrigerating
only AC unit).

3
USER'S MANUAL
Split Floor-Standing Air Conditioner

Operation Panel

(2)
Dehumidifying operation display Heating (ventilating) operation display

Refrigerating operation display High,Middle and low wind speed operation display
one bright fan blade indicates low wind speed,
two bright fan blade indicates middle wind speed,
three bright fan blade indicates high wind speed,
Display sign of fan
swinging fan blade indicates winging wind.

Room emperature display

Set temperature display


Timing display
h
Display lock-up function
Sleeping operation display

Swinging wind operation display Defrosting operation display

WIND SPEED SWINGING WIND MODE SELECTION KEY


SELECTION KEY SELECTION KEY Press the key to choose operation
TURN ON/OFF KEY Press the key to choose the wind modes of refrigerating,
speed and the wind speed
To choose different wind
Press the key to turn on or types of swinging windor set dehumidifying,heating (or
changes in the following order
turn off the AC unit. with each press:high,middle,low. wind by pressing this key. ventilating for refrigerating only
AC unit).

TEMPERATURE+ KEY
Press the key once to SLEEPING KEY
increase the set Press the key to choose sleeping
temperature by 10C,the mode,the AC will operate with low
highest temperature is MODE
wind speed and automatically
290C. turns off after 8 hours,Press the
key once again to cancel sleeping
mode.
TEMPERATURE- KEY
Press the key once to
reduce the set temperature TIMING KEY
by 10C,the lowest To press timing key to set turning
temperature is 180C. on time,turning off time and to
cancel timing,the time range is
1-12 hours.

Specification:
* Usually,the display screen shows only the function mode and operation status you choose.
* When room temperature equals to or is lower than 180C,the function of dehumidifying cannot be used.
* When room temperature equals to or is lower than set temperature,the AC unit stops for a period of time to save energy.
* The AC unit is equipped with automatic defrosting function and the defrosting operation display on the display screen is bright when the machine
defrosts.
* The AC unit with heat pump has auxiliary electric heating function,which will automatically turns on or off according to room temperature during
heating operation to achieve the best heating result.
* If you turn on the machine immediately after it is turned off,the machine with time-lapse starting function will automatically turns on the machine
after 3 minutes to protect it.

Note:the position and arrangement of keys in different models and different types of AC might vary,but the keys with same name have the same function.

4
*USE OF CONTROL PANEL* USER'S MANUAL
Split Floor-Standing Air Conditioner

Operation of Mode change between Refrigerating/Dehumidifying/Heating/Ventilating

1.Press on/off key


2. Press mode key to choose the mode you want
When you choose ventilating mode,the compressor does not work.
3.Press temperature +/- key to set the room temperature you
want
The room temperature range is 180C-290C.
4. Press the key of wind speed to set the speed you want from
high through middle to low
The fan operates in low speed under the mode of dehumidifying
5.Press the key of swinging wind to change wind direction
6.Press on/off key once again to stop.
If you turn on the machine immediately ofter it is turned off,the machine
with time-lapse starting function will automatically turns on the machine
MODE after 3 minutes to protect it.

Change wind direction

Change Left/Right Wind Direction


Press wind swinging key,the screen will display swinging wind blade,which changes wind
direction by swinging from left to right.
Set wind direction
When wind blade reaches the position you desire,press wind swinging key again to stop the
blade for a set wind direction.
Change up/down wind direction
Hold both ends of wind guide panel to change the wind sending angle.

Timing operation
h

Set turning off time


Set the time for the unit to turn off and when it is time,the AC will automatically stop operating.
Steps of setting turning off time
1. When AC is working,press the key of and the machine is in the timing status of turning off;
2. Press the key of continuously to reach the turning off time you want within a time range of 1-12 hours;five seconds later,the
machine is in the timing status of turning off;
3. After the turning off time is set,the AC unit will automatically turn off at your set time;
4. To cancel the timing,press the key of continuously till 12 is displayed,one more press and the timing is cancelled;when the
machine is working,only timing turning off function is functional.

Set turning on time


Set the time for the unit to turn on and when it is time,the AC will automatically start operating.
Steps of setting turning on time
1. When AC is working,press the key of and the machine is in the timing status of turning on;
2. Press the key of continuously to reach the turning on time you want within a time range of 1-12 hours;five seconds later,the
machine is in the timing status of turning on;
3. After the turning on time is set,the AC unit will automatically turn on at your set time;
4. To cancel the timing,press the key of continuously till 12 is displayed,one more press and the timing is cancelled;
5
USER'S MANUAL *USE OF REMOTE CONTROLLER*
Split Floor-Standing Air Conditioner

NOTE: Please check to refer the instructions for the identical remote controller of your air-conditioner.
Remote controller 1
Signal transmitting section.

Operation mode indictor Temperature indicator


Indicates the set temperature

Fan speed indicator

Lock key indicator


Time indicator
Air flow indicator

Sleep mode indicator


Temperature Setting button AM PM
This button is used to set the room ON-TIMER
Timed time indicator
OFF-TIMER H
temperature.Each pressing of the
" + " or " - " button,the ON/OFF button
temperature setting is increased Press this button will start the
or decreased by 10C. operations of the units.Press it once
again will stop the operations.
ON/OFF

HOLD button Operation Mode button


Press this button to lock or + - This button is used to select the
cooling,heating,or dehumidification
unlock the keyboard.
mode of operation.
SLEEP button sequence of mode switch is
This button changes to SLEEP cooling-dehumidification-heating.
operation,press again to cancel
the sleep operotion. (For the cooling-only models, the
SLEEP LAMP MODE "Heating" mode is for FAN).
Fan Speed Selection button
Press this button to select the high LAMP button
speed,med-speed or low speed Press this button to make the lamp
of air delivery. of control panel lights on or off.
FAN SP
TIMER button
EED HOLD SWING
This button is used to set the SWING button
switch-on or switch-off time. Used Press this button to select the
together with the "HOUR" button, left/right swinging of air delivery or
T IM E R to stop swinging.
the time setting can be made HOUR M IN
within the range of 1-12 hours,
with the interval of one hour. Time Setting button
This button is used to set the current
time or the time for timed switch-on
of switch-off.

* Above figure shows all indications for the purpose of explanation,but practically only the pertinent.

6
USER'S MANUAL
Split Floor-Standing Air Conditioner

This remote controller is the general one of our company,it can be used for many types of our air-
conditioners. We beg your forgiveness that we would not introduce the button or indicator which is not
applicable for the units you purchased.

Remote controller 2

Sleeping indicator

Temperature indicator
Cooling indicator ˚F indicates set temperature.

Dehumidifying indicator ˚C Swinging indicator

Heating indicator Fan speed indicator

Faning indicator Lock key indicator


ON
Timed time or
OFF current time indicator

TEMP SETTING button TEMP SETTING button


Each pressing of the button, the Each pressing of the button,
temperature setting is increased the temperature setting is
by 1˚C decreased by 1˚C

ON/OFF button
Press this button will start the operations
SWING button of the units.Press it once again will stop
Press this button to select the left/right the operations.
swinging of air delivery or to stop swinging. MODE button
DE

This button is used to select the cooling,


O
M

FAN SPEED button heating,or dehumidification mode of operation.


Press this button to select the high speed, sequence of mode switch is
mid-speed or low speed of air delivery. cooling-dehumidification-heating.
(For the cooling-only models, the "Heating" mode is for FAN).
TIMER button
This button is used to set the switch-on or LAMP button
switch-off time. Used together with the Press this button to make the lamp of control
"HOUR" button,the time setting can be made
HO

panel lights on or off.


within the range of 1-12 hours,with the IN
M
UR

interval of one hour.


MIN button
This button is used to set the current time.
HOUR button
This button is used to set the timed time
or the current time. HOLD button
Press this button to lock or unlock the keyboard.

SLEEP button
This button changes to SLEEP
operation,press again to cancel
the sleep operation.

* Above figure shows all indications for the purpose of explanation,but practically only the pertinent.

7
USER'S MANUAL
Split Floor-Standing Air Conditioner

This remote controller is the general one of our company,it can be used for many types of our air-
conditioners. We beg your forgiveness that we would not introduce the button or indicator which is not
applicable for the units you purchased.

Remote controller 3
Set temperature indicator

Fan speed indicator

Cooling indicator

Drying indicator AUTO SLEEP Sleeping indicator


COOL ECONO
Key hold indicator
Heating indicator DRY POWER
HEAT CLEAN
ON
Faning indicator FAN OFF HOLD
Air flow indicator
MODE TEMP
Timed time or current time indicator
TEMP SETTING button
ON/OFF Each pressing of the button, the temperature
MODE button setting is increased or decreased by 1˚C.
This button is used to select the cooling ,dry,
heating (faning) mode of operation. ON/OFF button
Press this button will start the operations of
TIMER HOUR MIN the units.Press it once again will stop the
operations.
TIMER button
This button is used to set the switch-on or SLEEP HOLD LAMP
HOUR button
switch-off time. Used together with the This button is used to set the timed time or
"HOUR" button,the time setting can be made FAN SPEED CLEAN SWING the current time.
within the range of 1-12 hours,with the interval
of one hour. MIN button
This button is used to set the current time.
SLEEP button
This button changes to sleep operation,press LAMP button
again to cancel the sleep operation. Press this button to make the lamp of control
panel lights on or off.

SWING button
FAN SPEED button
Press this button to select the left/right swinging
Press this button to select the high speed,mid-
of air delivery or to stop swinging.
speed or low speed of air delivery.

HOLD button
Press this button to lock or unlock the keyboard.

* Above figure shows all indications for the purpose of explanation,but practically only the pertinent.

8
USER'S MANUAL
Split Floor-Standing Air Conditioner

Operating Machine In selected modes


1. Point the remote controller at the unit,press the MODE button,select the needed mode :cooling,heating (ventilating for cooling-
only model) and dry.
2. Press the temperature setting button to increase or decrease the readings until the needed temperature is displayed;
* In cooling/heating operations,the temperature difference of 50C between the selected temperature and the ambiend temperature
is most suitable for your health.
3. Press fan speed button to choose the air volume you want.
4. Press swing button to choose the left/right air direction you want.

PRESENT TIME SETTING PROCEDURE


Methods 1(Suitable for remote controller 1and 2)
1. When cells are inserted,under the timer operation has not been set,unload the back cover, push the "CLK" button with the tip of a
ball pen,etc.The time indicator is flickering and can set the present time.
2.Press the HOUR button to set you desired time. RS
T

3.Press the MIN button to set you desired time. CL


K

4. Press the CLK button again, then reatach the back cover.
5.In case of the abnormally use of remote controller,press the RST button
to reset the remote controller.

Methods 2(Suitable for remote controller 3) Methods 1


When cells are inserted,under the timer operation has not been set
1.Continually press the HOUR button about 2 seconds,the time indicator is flickering and press the HOUR button to set you desired
time.
2. Continually press the MIN button about 2 seconds,the time indicator is flickering and press the MIN button to set you desired
time.
3.Press the ON/OFF button to confirm the set time or it would automatically exit the time setting state after 15 seconds.
If when the remote controller is at abnormal state,you can take out the batteries on the back cover to clear off the display.

SLEEP OPERATION PROCEDURE


Use this mode to reduce operation sound when sleeping,etc.
Press the SLEEP button,the air flow sound from the indoor unit is decreased.
Press the SLEEP button again can release the mode.
and the air conditioner will be stopped automatically in 8 hours.
NOTE:
* Use the sleep mode when you are going to bed.If this mode is used in the day,the capacity is reduced since

the ambient temperature is too high.(COOL MODE).


* During the operation of cooling,the room temperature will be raised by 10C higher than the setting after the

machine begins to operate in the sleeping mode.


* During the operation of heating mode,the room temperature will be dropped 20C lower than the setting after

the machine begins to operate in the sleeping mode.

TIMER OPERATION PRODEDURE


Timed switch-off
1.Duing the operation of the air conditioner,press the TIMER button and the air conditioner will enter the timed switch-off mode.
2. Press the HOUR button to set the needed time.Every the button is pressed,indication change is the following sequence:
1 * 2 * ........ * 12*1
3.After the setting,the digits shown on the display screen will go down by 1 for every elapsed hour.

9
USER'S MANUAL
Split Floor-Standing Air Conditioner

Timed switch-on
1.When the air conditioner is in the standby mode,press the TIMER button and the air conditioner will enter the timed switch-on
mode.
2.Press the HOUR button to set the needed time,The timer can make the setting in the range from 1-12 hours.
3. After the setting.the digits shown on the display screen will go down by 1 for evey elapsed hour.

Releasing procedure
Press the TIMER button again to release the mode.

REPLACEMENT OF BATTERIES

* When the signal from the remote controller become weak and the indoor unit can not receive it
properly;or the indications on the display screen becomes blurred,please replace with two new batteries.
* The positive and negative poles must match the installation positions.
* New batteries of the same type have to be used for replacement.
* If the remote controller is not to be used for long time,take out the batteries so as to prevent the leakage
of the electrolyte from damaging the controller.

NOTE:

1. Do not use an old battery with with a new one.


2.The life of cell made in conformity to JIS or IEC is 6 to 12 moths in normal use,If it is used longer or an unspecified
cell is used,a liquid leaks from the cell,causing the remote controller inoperative.
3.Guideline of the life time is printed on the battery.The battery life may be shorter than that of air conditioner
depending on the date of manufacture,However,the battery may be alive ever after the norminal life time expired.

10
*METHODS OF MAINTENANCE* USER'S MANUAL
Split Floor-Standing Air Conditioner

Make sure that the power of the air conditioner is turned off before the maintenance is to be done.

Cleaning

* Power must be turned off before Removal of the filter screen Cleaning of the filter screen
doing the cleaning. * Make sure that the operation of the Gently pat the screen or use a vacuum
* Use a piece of soft dry cloth to clear air conditioner is fully stopped. cleaner to do the cleaning. If too much
off the dust on the units. * Remove the fixing screws of the air- filth is accumulated on the screen, a
* Do not use volatile oil, gasoline, return grids. small amount of neutral detergent
diluting agents or abrasive power, etc. * Pull in the direction of arrow (1) to solution can be used for the cleaning.
in doing the cleaning. open the grids.
* Use household neutral detergent to After the cleaning, the screen must be
* Pull in the direction of arrow (2) to
clean the fingerprints or oil stains. dried in air and be put back into place.
take out the air filter screen.
* Do not use water to flush the units. (The air filter screen is loaded inside
the air-return grids).
*

Handle

Prior To Operational Seasons After The Operational Seasons

* Check to see if the air outlets of the indoor and outdoor


units are blocked; * Disconnect the power source
of the air conditioner.
* The protective cover of the outdoor unit must be
removed. * Before pulling out the power
Air outlet
is blocked. plug, make sure that the
operation of the machine is fully
stopped.

Air inlet is
blocked. * Make proper maintenance to the air filter screen and
other parts.

* Please use a plastic


* Check to see if the power cable and grounding wire are sheet to cover the unit
in proper state. to prevent dust or filth
from entering the outdoor
unit.

* Check and confirm that there is any bending, or


raised ends or blockage of the drainage tubes. N.B
* Make sure that the air filter screen is properly in place Do not place the air filter screen under the exposure of
before operating the machine. sunlight or near an over to dry; do not use warm water
0
If the machine is operated with the air filter screen removed, dust and foreign objects above 40 C to do the cleaning so as to avoid deformation.
will result in faulty performances of the air conditioner.

11
USER'S MANUAL *PHENOMENA DIAGNOSIS AND TREATMENT*
Split Floor-Standing Air Conditioner

Please read the following contents before contacting the maintenance people:

TROUBLE PHENOMENA CAUSES TREATMENT

Press the ON/OFF button again after


Power failure the power is resumed
Power source not connected Connect to the power source.
Air conditioner Press the ON/OFF
does not work. button but the air Fuse blown Replace fuse
conditioner does not
work. Breaker in off position Connect the breaker.
Room temperature not properly Reduce or increase the room
adjusted temperature setting.
There is air delivery Dust blocking the air filter screen Clean the air filter screen.
at the outlet, but it Control panel
is not cooling or indications normal Blocking objects at the inlet or
outlet of the indoor or outdoor units Remove the objects.
heating
Door or windows open Close the door or windows.

If the above-stated problem is not solved even after the related corrective measure is taken, please disconnect the power source
and contact our Co. dealer of the authorized maintenance shop.

The following phenomena air not faulty operational performances:

Unpleasant
smell
"ZZZ..."
"Patting
sound"
The air inside the
room smells cigarette The sound of refrigerant flowing
smoke or other odd
odors.

Sometimes the air sent out from the air During the operation or when the machine When the cooling or heating operation is
conditioner may smell some odd odors. started or stopped, some "patting" sound
is stopped, some "ZZZ..." sound may be
This is due to the cigarette smoke, the may be heard. This is because some parts
heard. This is because the refrigerant
cosmetic smell, the odors of walls or of the surface boards are expanded due
furniture pieces in the room that are inside the air conditioner is still flowing. to changes of temperature, which results
stained on the air conditioner. in the friction of these parts. This is not a
performance fault.

12