Weld Calculation

Column dimension = 350x175x7x11


B = 175
H = 350
tf = 11
tw = 7
Beam dimension = 350x175x7x11
B = 175
H = 350
tf = 11
tw = 7

Ultimate Moment Mu = 10346000 Nmm


jd = 350 mm
Ultimit tension force T = Mu / jd
= 29560 N

Weld Capacity is the minimum value of :


(1) Weld Capacity = 0.3x fw x lw x tw
fw = 70 ksi = 490 Mpa
l weld = 125 mm
t weld = 5 mm
Weld Capacity = 91875 N

(2) Plate = 0.4 x Fy plate x lw x tw


t plate = 16 mm
Fy plate = 240 Mpa
l weld = 125 mm
t weld = 5 mm
= 60000 N

So, take Weld capacity = 60000 N OK


Text m Text Text KN KN KN KN-m
Frame Station OutputCase CaseType P V2 V3 T
TABLE: Element Forces - Frames
116 0 COMB6 Combinat 101.428 -10.397 -0.326 0.0031
102 3.64499 COMB4 Combinat 45.517 10.212 0.16 -0.000114
116 0 COMB6 Combinat 101.428 -10.397 -0.326 0.0031
KN-m KN-m
M2 M3

-2.8725 -10.346
-0.579 -8.5664
-2.8725 -10.346