You are on page 1of 12

www.jbctools.

com

RM
REWORK STATION
RM / REWORK STATION

DD-2B/1B/9B JTE-2B/1B/9B MS-A


CONTROL UNIT CONTROL UNIT DESOLDERING PUMP

CL9885 AD-SD DR-SD JT-SB


TIPS CLEANING STAND STAND STAND STAND

T245-A DR560-A T260-A C245903 C560013


HANDPIECE DESOLDERING SUCTION C245906
IRON HANDPIECE
C560004

C560005

2
JT-T2A (230V) or 0008752 T2050 ø20
JT-T1A (100V-120V) EXTRACTOR STAND T2250 ø40
HEATING SET TRIPOD
Extractor
E2184
E2064
E2052

Protector
P2220 (32)
P2230 (48)
P2235 (24)
P4000 (44)
P4010 (60)

JN2015 ø4 0932330 0930110 0901546


JN2012 ø6 SUCTION TUBE SUCTION CUPS STRAIGHT NEEDLES
JN2020 ø8
NOZZLE

0940163 0861660
CUPS BENT NEEDLES

S0354 0965760 0965970 0780550


SPONGE

0812360 0786640 0812620

0780840 0812630

3
0780637 0821830 0005966 0781046
CONNECTION CABLE SUCTION FILTER SET 50 FILTERS BOX SPARE COTTON FILTERS

CORD X2 MANUAL MANUAL MANUAL MANUAL

w w w.jbctools.com

RM
REWORK STATION

HEAT MANAGEMENT

JBC stations intelligently manage the tool temperature:


Work mode: When the tool is used, pre-set work temperature is 350º C.
Sleep mode: When the tool is in the stand, the temperature goes down to 180º C (depending of the configuration).
Hibernation mode: After longer periods of inactivity (pre-set i.e 30 minutes), the power is cut off and the
tool cools down to room temperature.

Heat management increase tip life which reduces cost of ownership.

4
INSTALLATION & PART NAMES

DR560-A
DESOLDERING IRON

MS-A
DESOLDERING
PUMP
DR-SD
STAND

AD-SD
STAND
DD-B T245-A
CONTROL HANDPIECE
UNIT

Power cord
socket

Equipotential
connection

JTE-B
CONTROL
UNIT
Power cord
socket

Equipotential
connection

Friendly
display
control
0964551
Pedal (Optional)

Suction Tube
for extractors
and tripods Heating
element

5
MS ELECTRIC DESOLDERING PUMP ELEMENTS

Control unit “switch on” indicator

Pump use indicator Desoldering air filter

CHANGING PUMP FILTERS

0821830
External filter

0781046
Spare filter

0007717
O Ring

0004710
Filter cover

0005966
Spare filter

6
REPLACING THE HEATING ELEMENT

FOLLOW THIS PROCESS INVERTED TO RE-CONNECT THE HEATING ELEMENT


This step has to be performed when the tool is stopped and the heating set is cold.
1. Untighten screw.
2. Separate the heating element from the heating set’s handle.
3. Connect the new heating element, pushing it’s extreme.
4. Insert screw to avoid air-loss which could reduce the heating element’s lifetime.

0014107 (230V) or
0014105 (100V-120V)
Heating element

JT-T2A (230V) or
JT-T1A (100V-120V)
Heating set
0009829
Handle

CHANGING THE HEATING SET


1. Ensure that the tool is stopped
2. Use a wrench to unscrew the cover
3. Pull back the seal
4. Pull connector from the socket to disconnect
the heating set from the station
5. Follow steps in reverse
to connect the heating set

7
HOT AIR DESOLDERING PROCEDURE

1. Lock the extractor 2. Hot-air melts the solder 3. IC is removed automatically

REMOVING THE NOZZLES

1
2

T260 PICK & PLACE


The suction cups can be adjusted to the needles in order
to make the placement of SMD of different sizes on boards easier.
These accessories allows the adjustment to weight and size
of any type of component.
When you assemble the suction cup with the needle,
you should avoid the needle to stick out of the lower part.

8
CL9885 TIP CLEANING STAND

CL6210 CL6210 Brass wool


BRASS WOOL CL6205 Inox wool

S0354 SPONGE
CL6220 Brushes

CL0354 Sponge

CL0236 WIPER

OPTIONAL

CL6205 INOX WOOL CL6220 BRUSHES TT-A TIP TINNER-CLEANER

CL0236 TIP WIPER

TAPPING WIPPING Wiper can be easily removed to clean it.

9
DD CONTROL SCREEN

Selected temp. 3 5 0 o C

Tip temperature

350 c
Power 10%
0

% Instant power supplied to the tool

Decrease & move down Access Menu & Increase & move up
Confirm Selection

SETTINGS MENU
ORIGINAL PIN: 0105
Main menu

Exit
1 Reset settings
2 Station settings
3 Tool settings

4 Counters
5 Program version

Station settings
Tool settings Counters
1 Temp unit Celsius
2 Maximum temp 4000C 1 Fix one temp ----- 1 Plugged hours 0
3 Minimum temp 2000C 2 Temp levels set OFF 2 Working hours 0
4 Nitrogen mode OFF 3 Sleep delay 0 min 3 Sleep hours 0
Port 1 Tool DR Port 1/2
5 Help text OFF
4 Sleep temp 1800C 4 Hibernation hours 0
6 Beep ON
5 Hibernation delay 30 min 5 No tool hours 0
7 Power limit 150W
6 Temp adjust O OC 6 Sleep cycles 0
8 Change PIN
7 Desold cycles 0
Back Back
Back
Port 1 Tool DR Port 1/2

10
JT CONTROL SCREEN PROFILE MODE
MANUAL MODE Selected profile Current temperature

Time to stop 45 seconds Profile 8


T e m p ºC Air %
ºC T e m p ºC
Current
temp. 400 80
400ºC Select
Graph of
selected
profile
380
Air 100%
Power 70% Time 125s.

Selected temperature % Instant power supplied to heater Remining time Selected flow

Decrease & Access Menu & Increase & Decrease Access Menu Increase
move down Confirm Selection move up profile number (pess key 2 seconds) profile number

You can switch between operating modes (Manual Mode / Profiles Mode) by pressing the “increase”
and “decrease” keys simultaneously for 2 seconds. (Only if mode profiles is ON)

SETTINGS MENU
ORIGINAL PIN: 0105
Main menu
1 Reset settings Profile settings
2 Station Settings 1 Profiles
3 Profile Settings 2 Edit Profile
4 Counters 3 Copy profile

5 Program version Exit


Exit
Settings
Edit Profile
1 Temp unit Celsius
ºC Select
2 Maximum temp 4500C
Profile
3 Minimum temp T OFF
*
4 Fix temp 4000C
8
5 Max air 100%
Counters
6 Min air 10%
7 Fix air 40% 1 Station ON hoursrs 0
2 Works hours 0 Edit Profile 8
8 Time to stop 120 sec
9 Beep ON 3 Works cycles 0 ºC
Step 4
10 Pop up ON Back Time 20
11 Change PIN Temp 450
Air 100
Back
Exit
* Selecting Tmin to “T OFF” allows
for blowing at ambient temperature.

11
TECHNICAL SPECIFICATIONS

DD
- Temperature selection from 90ºC (190ºF) to 450°C (840ºF) (±5%).
- Output Peak Power: 150W
- Safety transformer, mains separator and double isolation.
- DD-2B 230V 50/60Hz. Input fuse: 2A. Output: 23,5V.
- DD-1B 120V 50/60Hz. Input fuse: 4A. Output: 23,5V.
- DD-9B 100V 50/60Hz. Input fuse: 4A. Output: 23,5V.
- Total weight of unit: 3.9Kg (8,6lb)

JT
- Temperature selection: Room temperature / 150ºC to 450°C (300ºF to 840ºF).
Cool mode: T Off, can be used to blow air at room temperature.
- Ambient Operating Temperature: 10 to 40ºC (50-104ºF)
- Output Peak Power: 1000W.
- Air flow regulation: 6-45 l/min.
- Vacuum: 30% / 228 mmHg / 9 inHg
- JT-2B 230V 50/60Hz. Input fuse 4A.
- JT-1B 120V 50/60Hz. Input fuse 8A.
- JT-9B 100V 50/60Hz. Input fuse 8A.
- Total weight of unit: 5,7Kg (12,6lb)

MS-A
- Supply: 24V.
- Power: 12W.
- Weight of complete unit: 1,5 Kgs.

- Complies with CE standards on electrical safety, electromagnetic compatibility and


ESD protected housing “skin effect”.
- RoHS compliant.
- Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.

This product should not be


thrown in the garbage.

WARRANTY SERIAL Nº
JBC’s 2 year warranty covers this equipment against all
manufacturing defects, including the replacement of DEALER’S STAMP
defective parts and labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing
this form duly filled in.

DATE OF PURCHASE
0013081-0114

www.jbctools.com