JT-T2A (230V) or 0008752 T2050 ø20
JT-T1A (100V-120V) EXTRACTOR STAND T2250 ø40
HEATING SET TRIPOD
Extractor
E2184
E2064
E2052
Protector
P2220 (32)
P2230 (48)
P2235 (24)
P4000 (44)
P4010 (60)
0940163 0861660
CUPS BENT NEEDLES
0780840 0812630
3
0780637 0821830 0005966 0781046
CONNECTION CABLE SUCTION FILTER SET 50 FILTERS BOX SPARE COTTON FILTERS
w w w.jbctools.com
RM
REWORK STATION
HEAT MANAGEMENT
4
INSTALLATION & PART NAMES
DR560-A
DESOLDERING IRON
MS-A
DESOLDERING
PUMP
DR-SD
STAND
AD-SD
STAND
DD-B T245-A
CONTROL HANDPIECE
UNIT
Power cord
socket
Equipotential
connection
JTE-B
CONTROL
UNIT
Power cord
socket
Equipotential
connection
Friendly
display
control
0964551
Pedal (Optional)
Suction Tube
for extractors
and tripods Heating
element
5
MS ELECTRIC DESOLDERING PUMP ELEMENTS
0821830
External filter
0781046
Spare filter
0007717
O Ring
0004710
Filter cover
0005966
Spare filter
6
REPLACING THE HEATING ELEMENT
0014107 (230V) or
0014105 (100V-120V)
Heating element
JT-T2A (230V) or
JT-T1A (100V-120V)
Heating set
0009829
Handle
7
HOT AIR DESOLDERING PROCEDURE
1
2
8
CL9885 TIP CLEANING STAND
S0354 SPONGE
CL6220 Brushes
CL0354 Sponge
CL0236 WIPER
OPTIONAL
9
DD CONTROL SCREEN
Selected temp. 3 5 0 o C
Tip temperature
350 c
Power 10%
0
Decrease & move down Access Menu & Increase & move up
Confirm Selection
SETTINGS MENU
ORIGINAL PIN: 0105
Main menu
Exit
1 Reset settings
2 Station settings
3 Tool settings
4 Counters
5 Program version
Station settings
Tool settings Counters
1 Temp unit Celsius
2 Maximum temp 4000C 1 Fix one temp ----- 1 Plugged hours 0
3 Minimum temp 2000C 2 Temp levels set OFF 2 Working hours 0
4 Nitrogen mode OFF 3 Sleep delay 0 min 3 Sleep hours 0
Port 1 Tool DR Port 1/2
5 Help text OFF
4 Sleep temp 1800C 4 Hibernation hours 0
6 Beep ON
5 Hibernation delay 30 min 5 No tool hours 0
7 Power limit 150W
6 Temp adjust O OC 6 Sleep cycles 0
8 Change PIN
7 Desold cycles 0
Back Back
Back
Port 1 Tool DR Port 1/2
10
JT CONTROL SCREEN PROFILE MODE
MANUAL MODE Selected profile Current temperature
Selected temperature % Instant power supplied to heater Remining time Selected flow
Decrease & Access Menu & Increase & Decrease Access Menu Increase
move down Confirm Selection move up profile number (pess key 2 seconds) profile number
You can switch between operating modes (Manual Mode / Profiles Mode) by pressing the “increase”
and “decrease” keys simultaneously for 2 seconds. (Only if mode profiles is ON)
SETTINGS MENU
ORIGINAL PIN: 0105
Main menu
1 Reset settings Profile settings
2 Station Settings 1 Profiles
3 Profile Settings 2 Edit Profile
4 Counters 3 Copy profile
11
TECHNICAL SPECIFICATIONS
DD
- Temperature selection from 90ºC (190ºF) to 450°C (840ºF) (±5%).
- Output Peak Power: 150W
- Safety transformer, mains separator and double isolation.
- DD-2B 230V 50/60Hz. Input fuse: 2A. Output: 23,5V.
- DD-1B 120V 50/60Hz. Input fuse: 4A. Output: 23,5V.
- DD-9B 100V 50/60Hz. Input fuse: 4A. Output: 23,5V.
- Total weight of unit: 3.9Kg (8,6lb)
JT
- Temperature selection: Room temperature / 150ºC to 450°C (300ºF to 840ºF).
Cool mode: T Off, can be used to blow air at room temperature.
- Ambient Operating Temperature: 10 to 40ºC (50-104ºF)
- Output Peak Power: 1000W.
- Air flow regulation: 6-45 l/min.
- Vacuum: 30% / 228 mmHg / 9 inHg
- JT-2B 230V 50/60Hz. Input fuse 4A.
- JT-1B 120V 50/60Hz. Input fuse 8A.
- JT-9B 100V 50/60Hz. Input fuse 8A.
- Total weight of unit: 5,7Kg (12,6lb)
MS-A
- Supply: 24V.
- Power: 12W.
- Weight of complete unit: 1,5 Kgs.
WARRANTY SERIAL Nº
JBC’s 2 year warranty covers this equipment against all
manufacturing defects, including the replacement of DEALER’S STAMP
defective parts and labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing
this form duly filled in.
DATE OF PURCHASE
0013081-0114
www.jbctools.com