You are on page 1of 8

JT

HIGH-POWER HOT-AIR
STATION

Reference Guide

www.jbctools.com
JT / HIGH-POWER HOT-AIR

CONTENTS

CONTROL UNIT JT-SA JT-T2A (230V) or


STAND JT-T1A (100V-120V)
HEATING SET

0008748 T2050 ø20 0932015 ø4


EXTRACTOR STAND * T2250 ø40 0932012 ø6
TRIPOD * 0932020 ø8
NOZZLE
Extractor
E2184
E2084
E2068
E2064
E2052

Protector
P2220 (32)
P2230 (48)
P2235 (24)
P4000 (44)
P4010 (60)

0932330 0930110 CORD MANUAL


SUCTION TUBE * SUCTION CUPS *

JT
HIGH-POWER HOT-AIR
STATION

Reference Guide

* These accessories are not supplied with JT-2QA / JT-1QA / JT-9QA stations

2
INSTALLATION

Mains

Equipotencial
connector

Suction
Tube

Pedal 0964551 (Optional)

Heating element

Connectable tools:
JT-T2A / JT-T1A
TE-TA

DESCRIPTION

Display

Function keys
Main switch

Heater inlet

Activation of Vacuum inlet for tripods


suction pump and extractors

3
WORKING

Time to stop 45 seconds Remaining time


T e m p ºC Air %

Current temperature

Selected temperature
400 80
400ºC Select
Selected flow

Power 70%
% Instant power supplied to the heater

Decrease & move down Increase & move up


Access Menu
&
Confirm Selection

PRESS Key 2 seconds


to access Menu

SETTINGS

ORIGINAL PIN: 0105

Main menu
1 Reset settings
2 Settings
3 Counters
4 Program version

Settings Exit

1 Temp unit Celsius


2 Maximum temp 4500C
3 Minimum temp T OFF Counters
4 Fix temp 4000C
1 Station ON hours 0
2 Works hours 0
5 Max air 100%
3 Works cycles 0
6 Min air 10%
Back
7 Fix air 40%
8 Time to stop 120 sec
9 Beep ON
10 Pop up ON
11 Change PIN
Back

4
DESOLDERING PROCEDURE

1. Lock the extractor

2. Hot-air melts the solder

3. IC is removed automatically

5
MAINTENANCE

FOLLOW THIS PROCESS INVERTED TO RE-CONNECT THE HEATING ELEMENT


This step has to be performed when the tool is stopped and the heating set is cold.
1. Untighten screw.
2. Separate the heating element from the heating set’s handle.
3. Connect the new heating element, pushing it’s extreme.
4. Insert screw to avoid air-loss which could reduce the heating element’s lifetime.

0006993 (230V) or
0007565 (100V-120V)
Heating element

JT-T2A (230V) or
JT-T1A (100V-120V)
Heating set
0009829
Handle

CHANGING THE HEATING SET


Ensure that the tool is stopped.
Use a wrench to unscrew the cover.

Move back the cover. Pull the connector from the socket to disconnect the heating set from the station.
Follow this process inverted to re-connect the heating set.

6
7
TECHNICAL SPECIFICATIONS

- Temperature selection from150 to 450°C (±5%) and “cool”.


- Power: 1000W.
- Air flow regulation: 6-45l/min.
- JT-2A 230V control unit. Input: 230V 50/60Hz.
- JT-1A 120V control unit. Input: 120V 50/60Hz.
- JT-9A 100V control unit. Input: 100V 50/60Hz.
- Total weight of unit: 2.5Kg.
- Complies with CE standards on electrical safety, electromagnetic compatibility and ESD protected housing
“skin effect”.
- RoHS compliant.
- Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.

This product should not be


thrown in the garbage.

WARRANTY
The JBC 2 years warranty, guarantees this equipment against all
manufacturing defects, covering the replacement of defective parts
and all necessary labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing this,
fully filled in, sheet.

SERIAL N`

STAMP OF DEALER

DATE OF PURCHASE
0009044/0211