Professional Documents
Culture Documents
Professional practices :
Work experience :
Involved in the planning, design and construction of buildings.
Presentation drawing
Client meeting
Working drawing ,Interior
Municipal drawing layout
Carry out 3D designs or 2D designs as required.
Visiting sites and building relationships with site managers.
34 Acers Layout-Model
WEST SIDE PRESENTATION DRAWING
EAST SIDE PRESENTATION DRAWING
NORTH FACING PRESENTATION DRAWING
ALI AZZAM PRESENTATION DRAWING
OFFICE USE
OFFICE
SEAL
CSC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
9.75 m o/o
9.75 m o/o
9.75 m
9.75 m
CAR PARKING CAR PARKING CAR PARKING
DUCT
CONDITIONS:
DUCT
1 The permission accorded does not confer any ownership rights,
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
At a later stage if it is found that the documents are false and
OPEN TO SKY OPEN TO SKY OPEN TO SKY OPEN TO SKY OPEN TO SKY OPEN TO SKY OPEN TO SKY fabricated the permission will be revoked U/s 450 of HMC Act
DUCT
DUCT
1955.
2 If construction is not commenced within one year, building
application shall be submitted afresh duly paying required fees.
3 Sanctioned Plan shall be followed strictly while making the
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 construction.
4 Sanctioned Plan copy as attested by the GHMC shall be displayed
at the construction site for public view.
5 Commencement Notice shall be submitted by the applicant
1.14 m before commencement of the building U/s 440 of HMC Act.
24.99 m o/o
24.99 m o/o
6 Completion Notice shall be submitted after completion of the
building & obtain occupancy certificate U/s 455 of HMC Act.
5.18 m o/o
5.21 m
5.18 m
5.18m WIDE INTERNAL DRIVE WAY 5.18m WIDE INTERNAL DRIVE WAY 5.18m WIDE INTERNAL DRIVE WAY 8 Public Amenities such as Water Supply, Electricity Connections
will be provided only on production of occupancy certificate.
9 Prior Approval should be obtained separately for any
modification in the construction.
10 Tree Plantation shall be done along the periphery and also in
front of the premises.
11 Tot-lot shall be fenced and shall be maintained as greenery at
owners cost before issue of occupancy certificate.
12 Rain Water Harvesting Structure (percolation pit) shall be
15.24 m o/o
constructed.
13 Space for Transformer shall be provided in the site keeping the
49 50 51 52 53 54 55
UP
56 57 58 59 60 61 UP 62 63 64 65 66 safety of the residents in view.
LIFT LIFT
2.03X 1.71m 2.03X 1.71m
14 Garbage House shall be made within the premises.
6.11 m
15 Cellar and stilts approved for parking in the plan should be used
2.51 m
2.51 m
DUCT
A A'
DUCT
DUCT
OPEN TO SKY OPEN TO SKY exclusively for parking of vehicles without partition walls & rolling
OPEN TO SKY OPEN TO SKY
10.06 m o/o
shutters and the same should not be converted or misused for any
DUCT
OPEN TO SKY OPEN TO SKY OPEN TO SKY other purpose at any time in future as per undertaking submitted.
DUCT
16 No. of units as sanctioned shall not be increased without prior
10.06 m
10.06 m
ELECT.DUCT ELECT.DUCT
DUCT
DUCT
DUCT
DUCT
1.52 m 2.03X 1.89m 1.52 m 2.03X 1.89m
1.52 m
1.52 m
approval of GHMC at any time in future.
CAR PARKING
DUCT
1.22 m
1.22 m
1.52m WIDE SIT-OUT
1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22 M WIDE BALCONY 30 Architect / Structural Engineer if changed, the consent of the
W1 W1 W1 W1 W1 W1 W1 previous Architect / Structural Engineer is required and to be
FD FD FD FD FD FD
FD1
intimated to the GHMC.
FD1 31 Construction shall be covered under the contractors all risk
BED ROOM
M.BED ROOM Insurance till the issue of occupancy certificate (wherever
3.66m x 4.98m 3.92m x 5.59m
BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM applicable).
LIVING M.BED ROOM 3.35mx 3.05m M.BED ROOM 3.35mx 3.05m M.BED ROOM 3.35mx 3.05m M.BED ROOM 3.35mx 3.05m M.BED ROOM 3.35mx 3.05m M.BED ROOM 3.35mx 3.05m
W1 W1 W1 W1 W1 W1 BED ROOM W1
3.73m x 3.56m 4.67m x 4.33m 4.67m x 4.33m 4.67m x 4.33m 4.67m x 4.33m 4.67m x 4.33m 4.67m x 4.33m M.BED ROOM 32 As per the undertaking executed in terms of G.O. Ms. No. 541
4.57m x 4.67m 4.25m x 3.05m
MA, Dt. 17-11-2000 (wherever applicable),
W4
W4 W4 W4 W4 W4 W4
W5 a) The construction shall be done by the owner, only in
D3 D3 D3 D3 D3 D3
D4 V 1.79 m 1.79 m 1.79 m 1.79 m 1.79 m 1.79 m D1 accordance with sanctioned Plan under the strict supervision of
D4 D4 D4 D4 D4 D4
the Architect, Structural Engineer and site engineer failing which
11.51 m o/o
TOILET V V V V V V V V V V V V D2 V1
1.63 m
1.63 m
1.63 m
1.63 m
1.63 m
D2 V1
1.73 m
1.73 m
1.73 m
1.73 m
1.73 m
1.73 m
1.73 m
D3 C.TOILET D3 C.TOILET D3 D3 D3 D3 D2
1.42 m
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
1.63
DUCT
1.98m x 1.52m 1.98m x 1.52m 1.98m x 1.52m 1.98m x 1.52m 1.98m x 1.52m 1.98m x 1.52m
DUCT
DUCT
DUCT
DUCT
DUCT
DUCT
TOILET TOILET TOILET TOILET TOILET TOILET TOILET
D4 2.44m x 1.52m
b) The Owner, Builder,Developer, Architect, Structural Engineer
3.35 m
2.44m x 1.52m 2.44m x 1.52m 2.44m x 1.52m 2.44m x 1.52m 2.44m x 1.52m 2.44m x 1.52m
FLAT AREA : 137.21 sqm D2 2.44m x 1.52m
DUCT
D4 D4 D4 D4 D4 D4
V TOILET
1.27 m 1.27 m 1.27 m 1.27 m 1.27 m 1.27 m and Site Engineer are jointly & severely responsible to carry out
D4 0.46 m0.46 m 0.46mm0.46 0.46 m0.46 m 0.46 m0.46 m 0.46 m0.46 m 0.46 m0.46 m
2.06 m
10.29 m
3.73m x 2.97m 2.44m x 1.52m FLAT AREA : 84.26sqm FLAT AREA : 84.26sqm FLAT AREA : 84.26sqm FLAT AREA : 84.26sqm FLAT AREA : 84.26sqm FLAT AREA : 84.26sqm 96.024 SQ.M. W3 sanctioned plan.
W4 W4 W4 W4 W4 W4
V
DINING DINING DINING DINING DINING DINING c) The Owner, Builder,Developer, Architect, Structural Engineer
0.46 m
D4 1 D2
0.46 m
W2
4.43m x 2.87m
2 LIVING
3.35m x 2.87m
W2
4.43m x 2.87m
3 LIVING
3.35m x 2.87m
W2
4.43m x 2.87m
4 LIVING
3.35m x 2.87m
W2
4.43m x 2.87m
5 LIVING
3.35m x 2.87m
W2
4.43m x 2.87m
6 LIVING
3.35m x 2.87m
W2
4.43m x 2.87m
7 LIVING
3.35m x 2.87m W2
DINING
4.67 x2.87m 8 and Site Engineer are jointly and severely are held responsible for
the structural stability during the building construction and should
W4 PUJA LIVING strictly adhere to all the conditions in the G.O.
0.84x0.52m
KW2 4.25m X 5.11m d) The Owner / Builder,Developer, should not deliver the
3.73 m
2.13 m
2.13 m
2.13 m
2.13 m
2.13 m
2.13 m
DRAWING DRAWING DRAWING DRAWING DRAWING DRAWING KITCHEN
1.22m WIDE 3.21m x 2.13m 1.22m WIDE 3.21m x 2.13m 1.22m WIDE 3.21m x 2.13m 1.22m WIDE 3.21m x 2.13m 1.22m WIDE 3.21m x 2.13m 1.22m WIDE 3.21m x 2.13m 3.45m x 2.13m
24.99 m o/o
UTILITY 3.25m x 2.24m W3 UTILITY 3.25m x 2.24m W3 UTILITY 3.25m x 2.24m W3 UTILITY 3.25m x 2.24m W3 UTILITY 3.25m x 2.24m W3 UTILITY 3.25m x 2.24m W3 from GHMC after providing all the regular service connections to
KW1 W3
PARAPET PARAPET PARAPET PARAPET PARAPET PARAPET PARAPET each portion of the building and duly submitting the following.
22.56 m o/o
KW2 KW2 KW2 KW2 KW2 KW2 1.22m WIDE
D1 WALL D1 WALL D1 WALL D1 WALL D1 WALL D1 WALL D1 WALL UTILITY (i) Building Completion Certificate issued by the Architect duly
D
certifying that the building is completed as per the sanctioned
1.98 m
KW1
PARAPET
W3
PARAPET
1.83 m
plan.
1.98 m
1.98 m
1.98 m
1.98 m
WALL
WALL
COMMON AREA COMMON AREA COMMON AREA COMMON AREA (ii) Structural Stability Certificate issued by the Structural
1.98m WIDE CORRIDOR COMMON AREA 1.98m WIDE CORRIDOR 1.98m WIDE CORRIDOR
Engineer duly certifying that the building is structurally safe and
W1 W3
the construction is in accordance with the specified designs.
D1 D1 6.86 m D1 D1 D1 D1 (iii) An extract of the site registers containing inspection reports
PARAPET PARAPET PARAPET PARAPET PARAPET PARAPET PARAPET of Site Engineer, Structural Engineer and Architect.
W4
WALL WALL WALL W4 WALL W4
WALL WALL W4 WALL W4 W4
(iv) Insurance Policy for the completed building for a minimum
3.35 m
3.35 m
M.BED ROOM LIFT LOBBY M.BED ROOM M.BED ROOM LIFT LOBBY M.BED ROOM M.BED ROOM period of three years.
DRAWING
4.33m x 4.67m 4.33m x 4.67m 4.33m x 4.67m 4.33m x 4.67m 4.33x 4.67m
3.73m x 3.05m BED ROOM
LIVING LIVING LIVING LIVING
33) Structural Safety and Fire Safety Requirements shall be the
M.BED ROOM 3.92m x 5.60m
3.66m x 4.98m W3
4.19m X 4.67m 4.19m X 4.67m 4.19m X 4.67m 4.19m X 4.67m LIVING responsibility of the Owner, Builder/ Develop,
W4 1.22 m W4 W4 W4 W4 3.55m x 4.80m Architect and St. Engineer to provide all necessary Fire Fighting
W1 DN UP W1 W1 DN UP W1
installations as stipulated in National Building
7.39 m
D4 D4 D4 D4 V D4
V V V V
Code of India, 2005 like;
7.39 m
LIFT LIFT
1.73 m
1.73 m
1.73 m
1.73 m
1.63 m
W4
2.03X 1.71m 2.03X 1.71m
DUCT
DUCT
DUCT
DUCT
DUCT
TOILET TOILET TOILET TOILET TOILET i) To provide one entry and one exit to the premises with a
2.51 m
2.51 m
W4 DINING
A A'
D4 2.44m x 1.52m 2.44m x 1.52m 2.44m x 1.52m 2.44m x 1.52m 2.29m x1.52m
V minimum width of 4.5mts. and height clearance of
10.29 m
3.73m x 2.97m D3 D3 D3 D3 D3
11.51 m o/o
V V V V V ii) Provide Fire resistant swing door for the collapsible lifts in all
1.78 m
1.78 m
1.78 m
1.78 m
D4 FLAT AREA : 92.88 sqm FLAT AREA : 92.88 sqm FLAT AREA : 92.88 sqm FLAT AREA : 92.88 sqm FLAT AREA : 84.26sqm
DUCT
1.73 m
FLAT AREA : 137.21 sqm C.TOILET
DUCT
floors.
DUCT
DUCT
DUCT
DUCT
2.44m X 1.52m ELECT.DUCT 2.44m X 1.52m 2.44m X 1.52m ELECT.DUCT 2.44m X 1.52m
12
1.98m X1.52m
D4 1.52 m 1.52 m D4 D4 1.52 m 1.52 m D4 DINING
2.06 m
14 13 10 9
TOILET V 2.03X 1.89m 2.03X 1.89m D4 iii) Provide Generator, as alternate source of electric supply.
1.52 m
1.52 m
11
C.TOILET W2 W2 W2 W2 W2
DUCT
2.13 m
2.13 m
2.13 m
KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN
2.69 m
W4 each at Generator and Transformer area shall be provided as per
2.13 m
KW2 1.22m WIDE 3.21m x 2.13m W3 1.22m WIDE 3.21m x 2.13m W3 1.22m WIDE 3.21m x 2.13m W3 1.22m WIDE 3.21m x 2.13m W3 1.22m WIDE 3.11m x 2.13m
1.22 m
3.73 m
BED ROOM UTILITY UTILITY UTILITY UTILITY UTILITY I.S.I. specification No.2190-1992.
1.30m WIDE KITCHEN 3.92m x 3.78m KW2 KW2 KW2 KW2 KW2
UTILITY 2.46m x 3.73m
FD1 vi) Manually operated and alarm system in the entire buildings;
FD1 FD1 FD1 FD1 FD1 vii) Separate Underground static water storage tank capacity of
1.22 m
25, 000 lits. Capacity.
1.22 m
1.22 m
1.22 m
1.22 m
KW1 KW1 KW1 KW1 KW1
1.22 m
1.52m WIDE SIT-OUT 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY 1.22m WIDE BALCONY viii) Separate Terrace Tank of 25,000lits capacity for Residential
buildings;
KW1 3.73 m
11.93m
W1
3.05 m 9.03 m
4.60 m
B'
12.61 m o/o 9.03 m
4.60 m
3.05 m 9.03 m
4.60 m
3.05 m 8.19 m
3.76 m ix) Hose Reel, Down Corner.
x) Automatic Sprinkler system is to be provided if the basement
1.14 m area exceed 200Sq.mts.
xi) Electrical Wiring and installation shall be certified by the
90.60 m o/o electrical engineers to ensure electrical fire safety.
xii) Transformers shall be protected with 4 hours rating fire resist
TYPICAL FLOOR PLAN constructions.
xiii) To create a joint open spaces with the neighbours building /
premises for maneuverability of fire vehicles.
NAME OF THE OWNERS SPECIFICATIONS SCHEDULE OF OPENINGS SCHEDULE OF AREAS REFERENCE TITLE:
THE PROPOSED RESIDENTIAL LAYOUT IN D1 = 1.07X 2.10M W1 = 1.83X 1.40M A. A. & ASSOCIATES
1) SRI. K. KRISHNA S/O SRI. K. SRINIVAS. BASEMENT ------ C.R.S CEMENT MORTAR PROPOSED
SURVEY NO. 42/1, AREA 5 AC 10 G, 2) SRI K. HANUMANTH RAO S/O. SRI. K. DHARAMPURI FOUNDATION - ------ R.C.C FOOTING AND C.R.S MASONRY
D2 = 0.99 X 2.10M W2 = 1.52X 1.40M T.W FRAME AND PANEL SHUTTER EXISTING
ARCHITECTS, PLANNERS & INTERIOR DESIGNERS STILT FLOOR & TYPICAL FLOOR PLAN
D3 = 0.90X 2.10M W3 = 1.22X 1.40M "
SURVEY NO. 42/3, AREA 455 SQ.YDS. 3) SRI. MUKESH S/O. SRI. J BABU RAO. SUPER STRUCTURE ------ BRICK WORK IN C.M
D4 = 0.76 X 2.10M
SANCTIONED
SYED ANWAR AZIZ
OF BLOCK - 4
4) SRI. SATYANARAYANA S/O. SRI. L. RAMA KRISHNA RAO. W4 = 0.91X 1.40M " TO BE DISMANTLED CA / 75 / 566
SITUATED AT HYDERSHAH KOTE VILLAGE, 5) SRI SHIVA TEJA S/O. SRI. M.S. SRILAM.
ALL COLUMNS BEAMS AND SLAB --------- R.C.C WORK F/D = 2.13 X 2.10M KW1 = 1.22X 1.00M " AS PER SHEET No. 1/18
CHIEF CONSULTANT
ALL REPRESENTED BY G.P.A HOLDER SRI. BIMAL KEDIA S/O B.N. KEDIA FLOORING MOSIAC & SHABAD FLOORING KW2 = 0.91X 1.90M T.W FRAME AND GLASS SHUTTER
RAJENDRANAGAR MANDAL, RANGA REDDY DIST. SCALE DATE : NORTH SHEET NO.
6) M/S THEME PROJECT REPRESENTED BY ITS PARTNER PLASTERING -------- CEMENT PLASTERING V = 0.61X 0.60M
"
SRI.BIMAL KUMAR KEDIA S/O B.N. KEDIA SANITORY FITTING - --------- APPROVED QUALITY SCW= 2.40X 1.40M
" 1 : 100 01 - 03 - 2014
DEVELOPERS - M/S THEME PROJECT- 406, 4TH FLOOR, V.V. VINTAGE BOULEVARD, SOMAJIGUDA, HYDERABAD. ELECTRICAL FITTING ---------- APPROVED QUALITY
SIGNATURE (G.P.A. HOLDER)
12/18
OFFICE USE
OFFICE
SEAL
CSC TP-
B
PERMIT NO. DATE
91.74 m o/o
11.93 m 3.05 m 8.19 m 3.05 m 8.19 m 3.05 m 8.19 m 3.05 m 8.19 m 3.05 m 8.19 m 3.05 m 8.19 m 3.05 m 9.33 m
CONDITIONS:
11.30m
11.51 m
11.51 m
1 The permission accorded does not confer any ownership rights,
11.30 m
At a later stage if it is found that the documents are false and
10.08m
10.08 m
fabricated the permission will be revoked U/s 450 of HMC Act
OPEN TERRACE OPEN TERRACE OPEN TERRACE OPEN TERRACE OPEN TERRACE 1955.
OPEN TERRACE OPEN TERRACE OPEN TERRACE 2 If construction is not commenced within one year, building
application shall be submitted afresh duly paying required fees.
3 Sanctioned Plan shall be followed strictly while making the
construction.
4 Sanctioned Plan copy as attested by the GHMC shall be displayed
at the construction site for public view.
5 Commencement Notice shall be submitted by the applicant
24.99 m o/o
24.99 m o/o
1.98 m
6.05m 8 Public Amenities such as Water Supply, Electricity Connections
1.98 m
1.98 m
1.98 m
will be provided only on production of occupancy certificate.
9 Prior Approval should be obtained separately for any
0.69 m
modification in the construction.
10 Tree Plantation shall be done along the periphery and also in
D1 D1 front of the premises.
D1 D1 11 Tot-lot shall be fenced and shall be maintained as greenery at
owners cost before issue of occupancy certificate.
12 Rain Water Harvesting Structure (percolation pit) shall be
constructed.
UP UP 13 Space for Transformer shall be provided in the site keeping the
DN DN
safety of the residents in view.
7.59m
6.91m
14 Garbage House shall be made within the premises.
15 Cellar and stilts approved for parking in the plan should be used
2.51 m
2.51 m
A A' exclusively for parking of vehicles without partition walls & rolling
10.08m
10.08m
shutters and the same should not be converted or misused for any
11.51 m
11.51 m
11.30 m
11.30 m
11.30 m
OPEN TERRACE OPEN TERRACE OPEN TERRACE OPEN TERRACE OPEN TERRACE 16 No. of units as sanctioned shall not be increased without prior
1.52 m 1.52 m
1.52 m
1.52 m
approval of GHMC at any time in future.
1.22 m 17 This sanction is accorded on surrendering of Road affected
3.10 m 3.10 m portion of the site to GHMC free of cost with out claiming any
SCW SCW compensation at any time as per the undertaking submitted.
3.05 m 5.94 m 1.22 m 2.40 m 3.05 m 7.16 m 2.40 m 18 Strip of greenery on periphery of the site shall be maintained
as per rules.
19 Stocking of Building Materials on footpath and road margin
1.22 m
B'
wherever required with specified standards at their own cost.
4.60 m 22 A safe distance of minimum 3.0mts. Vertical and Horizontal
Distance between the Building &
High Tension Electrical Lines and 1.5mts. for Low Tension
11.93 m 3.05 m 9.03 m 12.61 m 9.03 m 3.05 m 9.03 m 12.61 m 9.03 m 3.05 m 8.19 m electrical line shall be maintained.
23 No front compound wall for the site abutting 18 mt. road width
90.60 m o/o shall be allowed and only Iron grill or Low height greenery hedge
shall be allowed.
24 If greenery is not maintained 10additional property tax shall be
imposed as penalty every year till the condition is fulfilled.
TERRACE FLOOR PLAN 25 All Public and Semi Public buildings above 300Sq.mts. shall be
constructed to provide facilities to physically handicapped persons
as per provisions of NBC of 2005.
26 The mortgaged built-up area shall be allowed for registration
only after Occupancy Certificate is produced.
27 The Registration authority shall register only the permitted
built-up area as per sanctioned plan.
28 The Financial Agencies and Institutions shall extend loan
facilities only to the permitted built-up area as per sanctioned
plan.
29 The Services like Sanitation, Plumbing, Fire Safety
7.16 m
7.16m requirements, lifts, electrical installations etc., shall be executed
under the supervision of Qualified Technical Personnel.
30 Architect / Structural Engineer if changed, the consent of the
FIRE FIGHTING OVERHEAD
previous Architect / Structural Engineer is required and to be
OVERHEAD intimated to the GHMC.
WATER TANK WATER TANK BEHIND WATER TANK
WATER TANK
(10,000 Ltrs. CAPACITY) 31 Construction shall be covered under the contractors all risk
4.69m
Insurance till the issue of occupancy certificate (wherever
applicable).
32 As per the undertaking executed in terms of G.O. Ms. No. 541
MA, Dt. 17-11-2000 (wherever applicable),
0.91m
HEAD ROOM HEAD ROOM a) The construction shall be done by the owner, only in
accordance with sanctioned Plan under the strict supervision of
the Architect, Structural Engineer and site engineer failing which
TERRACE FLOOR TERRACE FLOOR the violations are liable for demolition besides legal action.
b) The Owner, Builder,Developer, Architect, Structural Engineer
and Site Engineer are jointly & severely responsible to carry out
and complete the constructionstrictly in accordance with
3.05m
3.05m
3.05m
3.05m
sanctioned plan.
Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor c) The Owner, Builder,Developer, Architect, Structural Engineer
and Site Engineer are jointly and severely are held responsible for
the structural stability during the building construction and should
FIFTH FLOOR FIFTH FLOOR
strictly adhere to all the conditions in the G.O.
d) The Owner / Builder,Developer, should not deliver the
possession of any part of built up area of the building by way of
3.05m
3.05m
3.05m
3.05m
Sale / Lease unless and until Occupancy Certificate is obtained
Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor from GHMC after providing all the regular service connections to
Corridoor
each portion of the building and duly submitting the following.
(i) Building Completion Certificate issued by the Architect duly
FOURTH FLOOR FOURTH FLOOR
19.28 m o/o
certifying that the building is completed as per the sanctioned
plan.
(ii) Structural Stability Certificate issued by the Structural
3.05m
3.05m
3.05m
3.05m
Engineer duly certifying that the building is structurally safe and
the construction is in accordance with the specified designs.
Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor
(iii) An extract of the site registers containing inspection reports
of Site Engineer, Structural Engineer and Architect.
THIRD FLOOR THIRD FLOOR (iv) Insurance Policy for the completed building for a minimum
period of three years.
33) Structural Safety and Fire Safety Requirements shall be the
3.05m
3.05m
3.05m
3.05m
responsibility of the Owner, Builder/ Develop,
Architect and St. Engineer to provide all necessary Fire Fighting
Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor installations as stipulated in National Building
Code of India, 2005 like;
SECOND FLOOR SECOND FLOOR i) To provide one entry and one exit to the premises with a
minimum width of 4.5mts. and height clearance of
5mts
ii) Provide Fire resistant swing door for the collapsible lifts in all
3.05m
3.05m
3.05m
3.05m
floors.
Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor Corridoor iii) Provide Generator, as alternate source of electric supply.
iv) Emergency Lighting in the Corridor / Common passages and
FIRST FLOOR FIRST FLOOR stair case.
v) Two numbers water type fire extinguishers for every 600
Sq.mts. of floor area with minimum of four numbers fire
extinguishers per floor and 5k DCP extinguishers minimum 2 Nos.
3.05m
3.05m
3.05m
3.05m
each at Generator and Transformer area shall be provided as per
I.S.I. specification No.2190-1992.
vi) Manually operated and alarm system in the entire buildings;
STILT FLOOR STILT FLOOR vii) Separate Underground static water storage tank capacity of
25, 000 lits. Capacity.
viii) Separate Terrace Tank of 25,000lits capacity for Residential
WEST SIDE ELEVATION buildings;
ix) Hose Reel, Down Corner.
x) Automatic Sprinkler system is to be provided if the basement
area exceed 200Sq.mts.
xi) Electrical Wiring and installation shall be certified by the
electrical engineers to ensure electrical fire safety.
xii) Transformers shall be protected with 4 hours rating fire resist
constructions.
xiii) To create a joint open spaces with the neighbours building /
premises for maneuverability of fire vehicles.
NAME OF THE OWNERS SPECIFICATIONS SCHEDULE OF OPENINGS SCHEDULE OF AREAS REFERENCE TITLE:
THE PROPOSED RESIDENTIAL LAYOUT IN A. A. & ASSOCIATES
1) SRI. K. KRISHNA S/O SRI. K. SRINIVAS. BASEMENT ------ C.R.S CEMENT MORTAR PROPOSED
W1 = 1.83X 1.40M HEAD ROOM PLAN & ELEVATION
SURVEY NO. 42/1, AREA 5 AC 10 G, 2) SRI K. HANUMANTH RAO S/O. SRI. K. DHARAMPURI FOUNDATION - ------ R.C.C FOOTING AND C.R.S MASONRY D1 = 1.07X 2.10M
W2 = 1.52X 1.40M
T.W FRAME AND PANEL SHUTTER EXISTING
ARCHITECTS, PLANNERS & INTERIOR DESIGNERS
D2 = 0.99 X 2.10M "
SURVEY NO. 42/3, AREA 455 SQ.YDS. 3) SRI. MUKESH S/O. SRI. J BABU RAO. SUPER STRUCTURE ------ BRICK WORK IN C.M
D3 = 0.90X 2.10M W3 = 1.22X 1.40M SANCTIONED
SYED ANWAR AZIZ
OF BLOCK - 4
4) SRI. SATYANARAYANA S/O. SRI. L. RAMA KRISHNA RAO. " TO BE DISMANTLED CA / 75 / 566
SITUATED AT HYDERSHAH KOTE VILLAGE, 5) SRI SHIVA TEJA S/O. SRI. M.S. SRILAM.
ALL COLUMNS BEAMS AND SLAB --------- R.C.C WORK
D4 = 0.76 X 2.10M W4 = 0.91X 1.40M
" AS PER SHEET No. 1/18
CHIEF CONSULTANT
ALL REPRESENTED BY G.P.A HOLDER SRI. BIMAL KEDIA S/O B.N. KEDIA FLOORING MOSIAC & SHABAD FLOORING F/D = 2.13 X 2.10M KW1 = 1.22X 1.00M T.W FRAME AND GLASS SHUTTER
RAJENDRANAGAR MANDAL, RANGA REDDY DIST. KW2 = 0.91X 1.90M
SCALE DATE : NORTH SHEET NO.
6) M/S THEME PROJECT REPRESENTED BY ITS PARTNER PLASTERING -------- CEMENT PLASTERING
V = 0.61X 0.60M "
SRI.BIMAL KUMAR KEDIA S/O B.N. KEDIA SANITORY FITTING - --------- APPROVED QUALITY
SCW= 2.40X 1.40M " 1 : 100 01 - 03 - 2014
DEVELOPERS - M/S THEME PROJECT- 406, 4TH FLOOR, V.V. VINTAGE BOULEVARD, SOMAJIGUDA, HYDERABAD. ELECTRICAL FITTING ---------- APPROVED QUALITY
SIGNATURE (G.P.A. HOLDER)
13/18
OFFICE USE
OFFICE
SEAL
CSC
2.44 m
Water Tank Water Tank
2.44 m
WaterTank as WaterTank as
per Plumbing per Plumbing
Const. Details Const. Details
CONDITIONS:
2.74 m
2.74 m
1 The permission accorded does not confer any ownership rights,
At a later stage if it is found that the documents are false and
TERRACE fabricated the permission will be revoked U/s 450 of HMC Act
TERRACE FLOOR FLOOR 1955.
2 If construction is not commenced within one year, building
0.79 m
0.79 m
0.60 m0.79 m
0.79 m
0.60 m0.79 m
0.79 m
0.79 m
0.60 m0.79 m
0.79 m
0.60 m 0.79 m
0.79 m
0.60 m 0.79 m
application shall be submitted afresh duly paying required fees.
3 Sanctioned Plan shall be followed strictly while making the
3.05 m
3.05 m
3.05 m
3.05 m
2.92 m
2.92 m
2.92 m
2.92 m
2.92 m
2.92 m
2.92 m
3.00 m
3.00 m
3.00 m
3.00 m
construction.
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET BED ROOM DINING ROOM MASTER BED
2.13 m
1.60 m
1.60 m
1.60 m
1.60 m
FIFTH at the construction site for public view.
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.80 m 0.76 m
0.76 m
LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET
FIFTH FLOOR 5 Commencement Notice shall be submitted by the applicant
FLOOR before commencement of the building U/s 440 of HMC Act.
0.60 m0.74 m
0.60 m0.74 m
0.60 m0.74 m
0.79 m
0.81 m
0.60 m 0.74 m
0.60 m 0.74 m
Roof Slab as per Roof Slab as per Roof Slab as per Roof Slab as per Roof Slab as per 6 Completion Notice shall be submitted after completion of the
Structural Details Structural Details Structural Details Structural Details Structural Details
building & obtain occupancy certificate U/s 455 of HMC Act.
3.05 m
3.05 m
3.05 m
3.05 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.93 m
2.95 m
2.95 m
2.95 m
2.95 m
7 Occupancy Certificate is compulsory before occupying any
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET BED ROOM DINING ROOM MASTER BED
building.
2.08 m
ROOM
1.60 m
1.60 m
1.60 m
1.60 m
8 Public Amenities such as Water Supply, Electricity Connections
FOURTH
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.80 m 0.76 m
0.76 m
BED ROOM TOILET
LIVING ROOM will be provided only on production of occupancy certificate.
FOURTH FLOOR FLOOR 9 Prior Approval should be obtained separately for any
23.32m
18.29 m o/o
18.34 m o/o
0.60 m0.74 m
0.60 m0.74 m
0.60 m0.74 m
0.81 m
0.60 m 0.74 m
0.60 m 0.74 m
modification in the construction.
10 Tree Plantation shall be done along the periphery and also in
3.05 m
3.05 m
3.05 m
3.05 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.93 m
front of the premises.
2.95 m
2.95 m
2.95 m
2.95 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET BED ROOM DINING ROOM MASTER BED
11 Tot-lot shall be fenced and shall be maintained as greenery at
2.13 m
ROOM
1.60 m
1.60 m
1.60 m
owners cost before issue of occupancy certificate.
1.60 m
1.60 m
THIRD
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.80 m 0.76 m
0.76 m
LIVING ROOM BED ROOM TOILET 12 Rain Water Harvesting Structure (percolation pit) shall be
THIRD FLOOR FLOOR constructed.
0.60 m0.74 m
0.60 m0.74 m
0.60 m0.74 m
0.81 m
13 Space for Transformer shall be provided in the site keeping the
0.60 m 0.74 m
0.60 m 0.74 m
Roof Slab as per Roof Slab as per Roof Slab as per Roof Slab as per Roof Slab as per
Structural Details Structural Details Structural Details Structural Details Structural Details safety of the residents in view.
3.05 m
3.05 m
3.05 m
3.05 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
14 Garbage House shall be made within the premises.
2.93 m
2.95 m
2.95 m
2.95 m
2.95 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
BED ROOM TOILET BED ROOM TOILET BED ROOM TOILET BED ROOM TOILET BED ROOM DINING ROOM MASTER BED
LIVING ROOM LIVING ROOM LIVING ROOM LIVING ROOM 15 Cellar and stilts approved for parking in the plan should be used
2.13 m
ROOM
exclusively for parking of vehicles without partition walls & rolling
1.60 m
1.60 m
1.60 m
1.60 m
1.60 m
SECOND
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.81 m 0.76 m
0.80 m 0.76 m
0.76 m
LIVING ROOM BED ROOM TOILET shutters and the same should not be converted or misused for any
SECOND FLOOR FLOOR other purpose at any time in future as per undertaking submitted.
16 No. of units as sanctioned shall not be increased without prior
0.60 m0.74 m
0.60 m0.74 m
0.60 m0.74 m
0.81 m
0.60 m 0.74 m
0.60 m 0.74 m
approval of GHMC at any time in future.
3.05 m
3.05 m
17 This sanction is accorded on surrendering of Road affected
3.05 m
3.05 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.95 m
2.93 m
2.95 m
2.95 m
2.95 m
2.95 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
1.37 m
LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET LIVING ROOM BED ROOM TOILET BED ROOM DINING ROOM MASTER BED portion of the site to GHMC free of cost with out claiming any
2.13 m
ROOM
compensation at any time as per the undertaking submitted.
1.60 m
1.60 m
1.60 m
1.60 m
1.60 m
FIRST 18 Strip of greenery on periphery of the site shall be maintained
0.76 m
0.76 m
0.76 m
0.76 m
0.76 m
0.76 m
LIVING ROOM BED ROOM TOILET
FIRST FLOOR FLOOR as per rules.
19 Stocking of Building Materials on footpath and road margin
Roof Slab as per Roof Slab as per Roof Slab as per Roof Slab as per Roof Slab as per
Structural Details Structural Details Structural Details Structural Details Structural Details causing obstruction to free movement of public & vehicles shall
2.88 m
3.05 m
3.05 m
3.05 m
2.95 m
2.95 m
2.93 m
2.93 m
2.95 m
2.87 m
10
9
8
20 The permission accorded does not bar the application or
7
6
5
provisions of Urban Land Ceiling & Regulations Act 1976.
4
3 STILT FLOOR 21 The Developer / Builder / Owner to provide service road
2
STILT FLOOR 1
wherever required with specified standards at their own cost.
22 A safe distance of minimum 3.0mts. Vertical and Horizontal
Distance between the Building &
High Tension Electrical Lines and 1.5mts. for Low Tension
electrical line shall be maintained.
23 No front compound wall for the site abutting 18 mt. road width
shall be allowed and only Iron grill or Low height greenery hedge
SECTION AT A-A' shall be allowed.
24 If greenery is not maintained 10additional property tax shall be
imposed as penalty every year till the condition is fulfilled.
25 All Public and Semi Public buildings above 300Sq.mts. shall be
constructed to provide facilities to physically handicapped persons
as per provisions of NBC of 2005.
26 The mortgaged built-up area shall be allowed for registration
only after Occupancy Certificate is produced.
27 The Registration authority shall register only the permitted
built-up area as per sanctioned plan.
28 The Financial Agencies and Institutions shall extend loan
facilities only to the permitted built-up area as per sanctioned
plan.
29 The Services like Sanitation, Plumbing, Fire Safety
requirements, lifts, electrical installations etc., shall be executed
under the supervision of Qualified Technical Personnel.
Slab as per
Structural Details
30 Architect / Structural Engineer if changed, the consent of the
previous Architect / Structural Engineer is required and to be
2.90 m
OVERHEAD
5.60 m o/o
applicable).
32 As per the undertaking executed in terms of G.O. Ms. No. 541
mm
0.91 m
1.83
and Site Engineer are jointly & severely responsible to carry out
and complete the constructionstrictly in accordance with
3.05 m
3.05 m
2.95 m
2.95 m
1.37 m
sanctioned plan.
c) The Owner, Builder,Developer, Architect, Structural Engineer
BED ROOM TOILET DINING KITCHEN Corridoor
and Site Engineer are jointly and severely are held responsible for
0.81 m 0.76 m
3.05 m
2.95 m
2.95 m
7.13 m 7.13 m from GHMC after providing all the regular service connections to
BED ROOM TOILET DINING KITCHEN Corridoor each portion of the building and duly submitting the following.
0.81 m 0.76 m
FIRE FIGHTING FIRE FIGHTING (i) Building Completion Certificate issued by the Architect duly
certifying that the building is completed as per the sanctioned
18.29 m o/o
3.05 m
2.95 m
2.95 m
5.79 m
5.79 m
Engineer duly certifying that the building is structurally safe and
1.37 m
WATER TANK WATER TANK (iv) Insurance Policy for the completed building for a minimum
3.00 m x 3.35 m LIFT MACHINE ROOM LIFT MACHINE ROOM 3.00 m x 3.35 m
Roof Slab as per 3.44 m x 3.35 m 3.44 m x 3.35 m
period of three years.
Structural Details
33) Structural Safety and Fire Safety Requirements shall be the
3.05 m
3.05 m
2.95 m
2.95 m
2.00 m
2.00 m
2.00 m
i) To provide one entry and one exit to the premises with a
minimum width of 4.5mts. and height clearance of
OPEN TERRACE OPEN TERRACE 5mts
3.05 m
3.05 m
ii) Provide Fire resistant swing door for the collapsible lifts in all
2.95 m
2.95 m
1.37 m
floors.
BED ROOM TOILET DINING KITCHEN Corridoor
iii) Provide Generator, as alternate source of electric supply.
0.76 m
stair case.
v) Two numbers water type fire extinguishers for every 600
Roof Slab as per
Structural Details Sq.mts. of floor area with minimum of four numbers fire
3.05 m
3.05 m
2.95 m
NAME OF THE OWNERS SPECIFICATIONS SCHEDULE OF OPENINGS SCHEDULE OF AREAS REFERENCE TITLE:
THE PROPOSED RESIDENTIAL LAYOUT IN A. A. & ASSOCIATES
1) SRI. K. KRISHNA S/O SRI. K. SRINIVAS. BASEMENT ------ C.R.S CEMENT MORTAR PROPOSED
SURVEY NO. 42/1, AREA 5 AC 10 G, 2) SRI K. HANUMANTH RAO S/O. SRI. K. DHARAMPURI FOUNDATION - ------ R.C.C FOOTING AND C.R.S MASONRY
W1 = 1.83X 1.40M T.W FRAME AND PANEL SHUTTER EXISTING
ARCHITECTS, PLANNERS & INTERIOR DESIGNERS SECTIONS & OVER-HEAD TANK PLAN
D1 = 1.07X 2.10M W2 = 1.52X 1.40M
SURVEY NO. 42/3, AREA 455 SQ.YDS. 3) SRI. MUKESH S/O. SRI. J BABU RAO. SUPER STRUCTURE ------ BRICK WORK IN C.M " SANCTIONED OF BLOCK - 4
D2 = 0.99 X 2.10M W3 = 1.22X 1.40M SYED ANWAR AZIZ
4) SRI. SATYANARAYANA S/O. SRI. L. RAMA KRISHNA RAO. " TO BE DISMANTLED CA / 75 / 566
SITUATED AT HYDERSHAH KOTE VILLAGE, 5) SRI SHIVA TEJA S/O. SRI. M.S. SRILAM.
ALL COLUMNS BEAMS AND SLAB --------- R.C.C WORK D3 = 0.90X 2.10M
W4 = 0.91X 1.40M " AS PER SHEET No. 1/18
CHIEF CONSULTANT
ALL REPRESENTED BY G.P.A HOLDER SRI. BIMAL KEDIA S/O B.N. KEDIA FLOORING MOSIAC & SHABAD FLOORING D4 = 0.76 X 2.10M
RAJENDRANAGAR MANDAL, RANGA REDDY DIST. KW1 = 1.22X 1.00M T.W FRAME AND GLASS SHUTTER SCALE DATE : NORTH SHEET NO.
F/D = 2.13 X 2.10M
6) M/S THEME PROJECT REPRESENTED BY ITS PARTNER PLASTERING -------- CEMENT PLASTERING KW2 = 0.91X 1.90M "
SRI.BIMAL KUMAR KEDIA S/O B.N. KEDIA SANITORY FITTING - --------- APPROVED QUALITY V = 0.61X 0.60M " 1 : 100 01 - 03 - 2014
DEVELOPERS - M/S THEME PROJECT- 406, 4TH FLOOR, V.V. VINTAGE BOULEVARD, SOMAJIGUDA, HYDERABAD. ELECTRICAL FITTING ---------- APPROVED QUALITY
SCW= 2.40X 1.40M
SIGNATURE (G.P.A. HOLDER)
14/18
Architecture Portfolio
C.K. & ASSOCIATES
ARCHITECT PLANER AND INTERIOR DESIGNER
OFFICE ADD.
OLD KUPWAD ROAD SANGLI
SANGLI : 416416 Tel. 0233 2671293
Ar. RAVIDRA M. CHAVAN
Work experience :
Involved in the planning, design and construction of buildings.
Presentation drawing
Client meeting
Working drawing ,Interior
Municipal drawing layout
Carry out 3D designs or 2D designs as required.
Visiting sites and building relationships with site managers.
valuation, estimate
Working project:
PERFORMA - I
A AREA STATEMENT SQ.M.
1 TOTAL AREA OF PLOT 4000.00
2 DEDUCTIONS FOR --
(A) ROAD ACQUISITION AREA. --
(B) PROPOSED ROAD --
(C) ANY RESERVATION --
TOTAL [ A+B+C ] .. --
3 NET GROSS AREA OF PLOT [ 1- 2 ] --
4 DEDUCTION FOR --
(A) RECREATION GROUND AS PER BY-LAW NO. 13.3.1 --
(B) INTERNAL ROADS --
(C) TOTAL [ A + B ] --
5 NET AREA OF PLOT [ 3 - 4C ] --
6 ADDITION FOR F.A.R. (TOTAL BUILT-UP AREA) FOR --
PURPOSE 2 (A) --
PURPOSE 2 (B) --
PURPOSE 2 (C) --
A. 100 % OF SET BACK AREA --
7 TOTAL AREA [ 5 + 6 ] 4000.00
8 F.A.R. PERMISSIBLE 1.00
TOTAL BUILT-UP AREA PERMISSIBLE 4000.00
MAX. GROUND COVERAGE ( FRACTION ) 1333.33
MAXIMUM NO. OF STOREYS 05
9 PERMISSIBLE FLOOR AREA [ 7 x 8 ] 4000.00
10 EXISTING FLOOR AREA --
11 PROPOSED BUILT-UP AREA 3920.96
12 EXCESS BALCONY AREA TAKEN IN F.A.R. [ AS PER B(C) BELOW ] --
13 TOTAL BUILT-UP AREA PROPOSED [ 10 + 11 + 12 ] 3920.96
14 F.A.R. CONSUMED [ 13/7 ] 0.98
C TENEMENT STATEMENT
[A] NET AREA OF PLOT ITEM A(7) ABOVE --
[B] LESS DEDUCTION OF NON-RESIDENTIAL AREA --
[C] AREA OF TENEMENTS [ A - B ] --
[C] AREA OF TENEMENTS [ A - B ] --
[D] TENEMENTS PERMISSIBLE ( AE PER GO/80/100 PER ACRES ) --
[E] TENEMENTS PROPOSED --
TOTAL TENEMENTS [ D + C ] --
D PARKING STATEMENT
[A] PARKING REQUIRED BY RULE --
[B] GARAGE PERMISSIBLE --
[C] GARAGE PROPOSED 34
[D] TOTAL PARKING PROVIDED 03
SITE PLAN LOADING UNLOADING STATEMENT --
E LOADING UNLOADING REQUIRED --
TOTAL LOADING/UNLOADING PROVIDED --
PERFORMA - II
CONTENTS OF SHEETS : FLOOR PLANS , ELEVATIONS , SECTIONS , SITE PLAN ,
LOCATION PLAN, AREA CALCULATIONS, SCHEDULE OF OPENINGS , PERFORMA I & II
COLOUR NOTE
PLOT BOUNDARY
PROPOSED BUILDING
DRAINAGE LINE
WATER LINE
REVISION DESCRIPTION DATE SIGNATURE
WINDOWS
W1 - 1.22 x 1.52 GLAZED WINDOW CASE FILE NO. 13109
W2 - 0.91 x 1.52 GLAZED WINDOW
W3 - 1.22 x 1.37 GLAZED WINDOW SCALE - 1:100, 1:300, 1:500
W4 - 1.22 x 2.13 GLAZED WINDOW
V - 0.61 x 0.91 GLAZED LOUVRED VENTILATOR
DATE - 15/09/2013
PARKING STATEMENT
Architect
COVERED CAR PARKING PROVIDED = 34
DWG NO - 01/ MUNICIPAL
Ravindra Chavan
M.Arch.(E.A.) F.I.I.A. F.I.I.I.D.
OPEN CAR PARKING PROVIDED = 30 DRN - VIJAY B.E.(Civil) A.M.I.E. M.ASCE F.I.V. M.I.I.B.E.
Registered Architect & Environmental Designer - CA/2000/26426
COVERED SCOOTER PARKING REQUIRED = 42 Govt. Approved Valuer for CAT. I / A-7236
Govt. Approved Surveyor & Loss Assessor SLA - 57563
OPEN SCOOTER PARKING REQUIRED = 28 CHKD - Ar. RAVINDRA Chartered Civil Engineer - RS004107
OWNER'S SIGNATURE Competent NDT Consultant - AM3140PN
PROJECT TITLE
C. K. ASS CIATES
Regd. Architects, Environmental Designers, Govt. Approved Valuers,
Surveyors & Loss Assessors, Competent NDT Consultants OFFICE
304/24, Shriram, Gajanan Colony, Old Kupwad Road SANGLI - 416416. M.S. India.
Phone- (0233) 2671293 / 6523393 Fax - +91-233-2671293 www.adobeinfra.com
CASE FILE NO. 13109
DATE - 15/09/2013
Architect
DWG NO - 01/ MUNICIPAL
Ravindra Chavan
M.Arch.(E.A.) F.I.I.A. F.I.I.I.D.
DRN - VIJAY B.E.(Civil) A.M.I.E. M.ASCE F.I.V. M.I.I.B.E.
Registered Architect & Environmental Designer - CA/2000/26426
Govt. Approved Valuer for CAT. I / A-7236
Govt. Approved Surveyor & Loss Assessor SLA - 57563
CHKD - Ar. RAVINDRA OWNER'S SIGNATURE
Chartered Civil Engineer - RS004107
Competent NDT Consultant - AM3140PN
PROJECT TITLE
C. K. ASS CIATES
Regd. Architects, Environmental Designers, Govt. Approved Valuers,
Surveyors & Loss Assessors, Competent NDT Consultants OFFICE
304/24, Shriram, Gajanan Colony, Old Kupwad Road SANGLI - 416416. M.S. India.
Phone- (0233) 2671293 / 6523393 Fax - +91-233-2671293 www.adobeinfra.com
KEDAR RESIDENCY
Aajara raod,igajavanao,gadinglajaij-
kaolhapur
LOCATION OF SITE
Residency
SITE LOCATION
COMMUNITY GARDEN
ENTRANCE GATE WITH SECURITY
SIDE VIEW
SIDE VIEW
SIDE VIEW
PARKING FLOOR PLAN WITH GARDEN
PARKING FLOOR
G
A
R
D
E
N
TYPICAL FLOOR PLAN
NARAYAN TALAV AT
CHIPLUN
For
Chiplun Ratanagiri
Interim Feasibility
Presentation to Advisory Committee
C. K. ASSOCIATES SANGLI-416416
PROPOSED CONSERVATION OF NARAYAN TALAV AT
CHIPLUN,
FOR CHIPLUN MUNCIPAL COUNCIAL CHIPLUN,
DIST. RATNAGIRI.
INDIA
CHIPLUN
Area and location
The total area included in the municipal boundary admeasures to 0000 hectares.
In Ratnagiri District.
NAME OF NO. OF
QUANTITY
0.573
A AREA STATEMENT
VEHICAL
TRUCK 06 1.175
1 AREA OF PLOT C.T.S. NO.A1 SURVEY NO. 28 2439.36 SQ.M.
CAR 29 2.100
2 DEDUCTIONS FOR --
BIKE 102 0.925
--
PLINTH BEAM PLINTH BEAM
0.600
TOTAL [ A+B+C ] ..
SECTION 1.13
3.460
1.20 1.13
0.150
4.460 3 NET GROSS AREA OF PLOT [ 1- 2 ] --
R.C.C FOOTING SCALE 1:100 R.C.C FOOTING --
4 DEDUCTION FOR
1.13
(A) RECREATION GROUND AS PER BY-LSW NO. 13.3.1
B B' (B) INTERNAL ROADS
3.460 1.20
WATCHMAN CABIN
3.0 X 3.0M
4.460
(C) TOTAL [ A + B ] --
5 NET AREA OF PLOT [ 3 - 4C ] --
1.13
6 ADDITION FOR F.S.I. (TOTAL BUILT-UP AREA) FOR --
PURPOSE 2 (A) --
PLAN ROOF PLAN
PURPOSE 2 (B) --
ELEVATION WATCHMAN CABIN AT PURPOSE 2 (C) --
SCALE 1:100
A. 100 % OF SET BACK AREA --
PLAY GROUND
7 TOTAL AREA [ 5 + 6 ]
8 F.S.I. PERMISSIBLE
TOTAL BUILT-UP AREA PERMISSIBLE
R.C.C BEAM
MAX. GROUND COVERAGE ( FRACTION ) [A +B ]000+000
0.100
MAXIMUM NO. OF STORES 57.56 SQ.M.
0.910
9 PERMISSIBLE FLOOR AREA [ 7 x 8 ] [A +B ]1952.25
1.430 10 EXISTING FLOOR AREA 57.56 SQ.M.
W.C.
W.C.
D2 LW LW D2 SECTION AT - A-A
W1 W1 [A] PERMISSIBLE BALCONY AREA PER FLOOR
SCALE 1:100
W.C.
W.C.
D2 LW LW D2
MAN HOLE [B] PROPOSED BALCONY AREA PER FLOOR [A +B ]000+000
R.C.C. SLAB VENT PIPE
[C] EXCESS BALCONY AREA [ TOTAL ]
W.C.
G.L.
TOILET
TOILET
LW D2
A 6.46 6.46 A
C TENEMENT STATEMENT
W.C.
INLET
OUT LET
LW D2
W1 W1
W.C.
LW D2
SECTION [B] LESS DEDUCTION OF NON-RESIDENTIAL AREA --
SOAK PIT
D D
[C] AREA OF TENEMENTS [ A - B ] --
TOILET BLOCK
0.50
0.97
[C] AREA OF TENEMENTS [ A - B ] --
0.23 [D] TENEMENTS PERMISSIBLE ( AE PER GO/80/100 PER ACRES ) --
0.23 1.00 1.58 1.50 2.81 [E] TENEMENTS PROPOSED --
TOTAL TENEMENTS [ D + C ] --
TOILET PLAN PLAN
SCALE 1:100 DETAILS OF SEPTIC TANK D PARKING STATEMENT
[A] PARKING REQUIRED BY RULE --
[B] GARAGE PERMISSIBLE --
Terrace slab
[C] GARAGE PROPOSED --
[D] TOTAL PARING PROVIDED --
LOADING UNLOADING STATEMENT --
E --
pipe
Filter 0.100
0.230
PROPOSED BUILDING
Building No. FLOOR NO. Area of Total Floor Area Use/Occupancy
filtered water Removable end cal of Proposed work od floors.
storage tank -----
A G+1+2+3+4 1952.25
wash out valve
-----
G.L.
Rain water harvesting plant details STAMP OF APPROVAL SHEET NO. 2/2
Not to scale.
R.C.C. DETAIL
INTERNAL WAY
INTERNAL WAY
INTERNAL WAY
INTERNAL WAY
PERFORMA - II
1.05 3.50
INTERNAL WAY CONTENTS OF SHEETS : FLOOR PLANS , ELEVATIONS , SECTIONS , SITE PLAN ,
LOCATION PLAN, AREA CALCULATIONS, SCHEDULE OF OPENINGS , PERFORMA I & II
10.0 M 2
3
AREA FOR BIKE
AREA FOR CAR
215.06 SQ.MT
470.57 SQ.MT
PARKING LAYOUT AQ. NO. 33 AT UKTAD
429.86 SQ.MT
4 AREA FOR TRUCK
45.99 SQ.MT
AT. CHIPLUN, DIST. RATNAGIRI.
5 AREA FOR TOILET
6 WATCHMAN CABIN 11.57 SQ.MT
7 AREA FOR ROAD 984.03 SQ.MT
8 AREA FOR GARDEN 161.00 SQ.MT
C. K. ASS CIATES
Regd. Architects, Environmental Designers, Govt. Approved Valuers,
Surveyors & Loss Assessors, Competent NDT Consultants OFFICE
PARKING LAYOUT 304/24, Shriram, Gajanan Colony, Old Kupwad Road SANGLI - 416416. M.S. India.
SITE PLAN Phone- (0233) 2671293 / 6523393 Fax - +91-233-2671293 www.adobeinfra.com
1.500
1.737
0.573
A AREA STATEMENT SQ.M.
3.500
1.175
WALKWAY
PATHWAY PATHWAY PATHWAY R.C.C COPING
2.100
COMPOUND
BRICKS WORKS
WALL
0.925
DRIVE WAY R.C.C JALI
PLINTH BEAM
G.L. G.L. TOTAL PLOT AREA 14137.15 SQ.M.
0.450
PLINTH BEAM
SECTION BB' ELEVATION
0.450
ELEVATION
0.150
R.C.C FOOTING
0.600
1.500
JOGGING TRACK - 1961.31
SCALE 1:200 4.460
3.460
0.150
1.13 1.20 1.13
1.13
B B'
3.500
4.460
WATCHMAN CABIN
3.460
1.20
3.0 X 3.0M
1.13
3.500
4.500
3.800
3.500 PLAN ROOF PLAN FITNESS TRAIN - 984.42
G.L.
PLAN WATCHMAN CABIN AT
2.99 SENIOR CITIZEN 4.500 PLAY GROUND BOUNDRY GARDEN - 520.00
1.500
2.96
2.99 SCALE 1:200
9.550
2.96
2.99
1.737
0.573
2.68 2.68 CHANGING ROOM - 75.90
1.175
2.68
3.78
2.100
2.84
AY
2.68
4.463 2.68 SECTION
0.925
1. GATE
2.68
2.96
W
2.68
2.68
WATER BODY - 60.00
TH
2.65
2.500
2.64 9
PA
2.64 2.9
EXIT
0.450
PLINTH BEAM
2.64
ELEVATION
E
2.64
2. WATCHMAN CABIN
ID
2.64 B SECTION BB'
W
2.64
2.64
ROAD AREA - 1850.79
M
2.64 9
2.9
0
2.64
2.5
2.64
3. ADMINISTRATIVE
18
2.64
4.9
2.64
LL
2.64
2.64 OTHER AREA - 3368.19
FA
Adaminstrative Building
2.63 25
3.4 6.0 X 3.0M
2.500
BUILDING
ER
SCHEDULE OF DOORS & WINDOWS
AT
2.50 M WIDE PATHWA
Y
W
2.70
ENTRY
9
4.6
PLAN ROOF PLAN
2.71
ADMINISTRATIVE OFFICE
6. PARKING GATE WATER BODY
PLAN
2.9
6
AT PLAY GROUND 02 D2 0.80 X 2.13 04 FLUSH DOOR
03 W 0.91 X 0.91 04 AL. SLIDING WINDOW
7. FITNESS TRAIL
9
4.6
2.71
04 V 0.61 X 0.75 04 LOUVERD WINDOW
26.000
8. CHILDREN PLAY
2.500
2.50
SCHEDULE OF DOORS & WINDOWS
1.53 0.45
0
20.000
AREA
2.71
WATCHMAN CABIN
3.500
9
4.6
1.200
9. SENIOR CITIZEN
2.100
Sr.No. TYPE SIZE NOS REMARK
1.200
0.900
0.450
01 D 0.90 X 2.10 01 T. W. PANELLED DOOR
2.71
G.L.
10.000
ELEVATION 02 W 1.20 X 1.20 02 AL. SLIDING WINDOW
SECTION AA'
3.25
11. KABBDI GROUND V V W W V V
16.000
2.72
W.C. W.C.
BATH 0.90X1.20 1.20X0.90 BATH
A 1.20X2.10 2.10X1.20 AREA STATEMENT
D1 D1
A'
12. VOLLEYBALL D1
3.709
4.0X5.20 M. 4.0X5.20 M.
Sr.No. TYPE SIZE NOS REMARK
GROUND
Y
WA
PATH
TRI DUSTBIN LOCKERS LOCKERS
01 D 0.90 X 2.10 1 T. W. PANELLED DOOR
13. CHANGING ROOM BASKET 02 W 1.20 X 1.20 04 AL. SLIDING WINDOW
IDE
SUN SET D D
MW
W
W
3.25
ENTRANCE
2.69
14. CONTROL ROOM
Terrace slab
2.50
13.410
DETAIL AT 'A'
CHANGING ROOM AT PLAY
15. EXIT WALL ROPE
PLAN
GROUND MAN HOLE
BARBED WIRE ANGAL
pipe
2.69
R.C.C COPING
3.25
2.61
storage tank
DELUXE PLINTH BEAM
3.25
PATHWAY
SECTION wash out valve
SOAK PIT
BENCH G.L.
16.000
4
GLOBE MGR R.C.C FOOTING Rain water harvesting plant details
2.61
2.8 O3.50
2.50 M WIDE
1.80
10.000
2.8
WIDE SL PLAN
2.61
4
2.8
IDE DETAILS OF SEPTIC TANK
4
2.8
MINI SLIDE
2.61
54
3.0
PERFORMA - I
BALANCING 26.000 A AREA STATEMENT SQ.M.
2.61
2.92
2 DEDUCTIONS FOR --
2.61
(A) ROAD ACQUISITION AREA. --
2.92
4 SEATER ARC
(B) PROPOSED ROAD --
(C) ANY RESERVATION --
Y
WA
TOTAL [ A+B+C ] .. --
TH
2.61
4 SEATER SS
2.92
E PA
4 DEDUCTION FOR --
MW
2.61
(B) INTERNAL ROADS
2.92
2.0
M WI
DE PA
THWA (C) TOTAL [ A + B ] --
Y
5 NET AREA OF PLOT [ 3 - 4C ] --
AD
2.61
6 ADDITION FOR F.S.I. (TOTAL BUILT-UP AREA) FOR --
2.92
PURPOSE 2 (A) --
INTERNAL RO
PURPOSE 2 (B) --
PURPOSE 2 (C) --
2.61
2.92
2.83
TOTAL BUILT-UP AREA PERMISSIBLE --
2.92
2.83
TH
MINI SWING
4.0 M WIDE
2.92
18.000
9 11 PROPOSED BUILT-UP AREA [A +B ]
ID
MW
2.83
2.50
2.62
--
2.92
2.62
PARCKING [C] EXCESS BALCONY AREA [ TOTAL ] --
SINGLE SS
20.500
2.92
WIDE SL
IDE 2.500
C TENEMENT STATEMENT
4 SEATER SS
AY
[A] NET AREA OF PLOT ITEM A(7) ABOVE --
2.62
THW
MINI SLIDE [B] LESS DEDUCTION OF NON-RESIDENTIAL AREA --
E PA
2.93
ID
[C] AREA OF TENEMENTS [ A - B ] --
MW
2.62
[D] TENEMENTS PERMISSIBLE ( AE PER GO/80/100 PER ACRES ) --
2.50
[E] TENEMENTS PROPOSED --
2.93
TOTAL TENEMENTS [ D + C ] --
2.62
D PARKING STATEMENT
ROLLER SLIDE 4 SEATER MGR
SITE PLAN [A] PARKING REQUIRED BY RULE --
2.93
2.62
SCALE 1:500
[B] GARAGE PERMISSIBLE --
MULTI PLAY SYSTEM [C] GARAGE PROPOSED --
[D] TOTAL PARING PROVIDED --
2.93
2.62
--
E --
WAVE SLIDE TOTAL LOADING/UNLOADING PROVIDED --
FORM OF STATEMENT 2
2.62
2.93
PROPOSED BUILDING
2.000
2.62
-----
2.93
VASHISHTI
RIVER STAMP OF APPROVAL SHEET NO. 2/2
WAY TO
PARKING
2.93
PLAY GROUND
SITE PLAN
FITNESS TRAIL 2.500
HIGHSCHOOL
3.85
SINGLE SS
PLAY GROUND
2.93
GLOBE MGR
3.85
2.500
PERFORMA - II
2.93
PLAY GROUND
2.34
FISH MUTTAN LOCATION PLAN, AREA CALCULATIONS, SCHEDULE OF OPENINGS , PERFORMA I & II
2.93
9 PARKING
MARKET ROAD
2.34
2.93
2.34
SCHOOL CERTIFICATE OF AREA
08052008
CERTIFIED THAT THE PLOT UNDER REFERENCE WAS SURVEYED BY ME ON
2.93
SWING
DOUBLE BAR AND THE DIMENSIONS OF SIDES ETC. OF THE PLOT STATED ON PLAN ARE
2.27
LOOP RING
MEASURED ON SITE AND THE AREA SO WORKED OUT TALLIES WITH THE AREA
2.5
00
LOCATION PLAN STATED IN DOCUMENTS OF OWNERSHIP / T.P. ACT.
2.27
2.50 M WIDE PATHWA
2.93
2.27
1.700
2.500
SCALE - 1:200, 1:500
2.27
3.31
1 2.50 M WIDE PATHWA
Y DWG NO - 01 / MUNICIPAL
Architect
Ravindra Chavan
2.27
3.36
M.Arch.(E.A.) B.E.(Civil) LL.B.
9 M WID
3.36
3.36
PROJECT TITLE
PLAY GROUND LAYOUT Surveyors & Loss Assessors, Competent NDT Consultants
304/24, Shriram, Gajanan Colony, Old Kupwad Road SANGLI - 416416. M.S. India.
OFFICE
Academic project
1)Design of Administrative Building (sem – 9)
This Was My Final Year Project
case study , site visit data collection,
master layout, elevation, section, detail , 3d
view
3)E.D. (sem – 10)
master layout , electrical l
ayout , drainage layout
group housing
landscape
cluster design