You are on page 1of 2

CPNI - Centre for the Protection of National Infrastructure

Blast resistant glass


Toughened glass 

Toughened (fully heat tempered) glass provides a degree of safety but not complete security and is 

therefore not recommended for external window or door use. 

It can, however, resist high blast pressures without damage provided it is well supported in a strong 

and rigid frame. When it does break its fragments cause fewer injuries than plain glass shards. When 

used on its own it should have anti‐shatter film applied. 

Laminated glass 

Laminated glass offers a higher level of protection than toughened glass. 

The minimum overall thickness of laminated glass classed as blast resistant is 7.5mm, including a 

minimum polyvinylbutryal (pvb) interlayer thickness of 1.5mm. The laminated glass should be fixed in 

a frame designed to withstand the bending effects of a static load of 7kN per square metre over the 

complete area of the glazing and frame. The fixings of rebates to the frame and of frame to the 

structure should be designed to withstand a line load of 20kN per metre of perimeter. 

These loads are broadly applicable, for nominal design without factors of safety, to most glazing 

systems incorporating 7.5mm laminated glass, but are based on requirements for panes of about a 2 

square metre area. The loads should be factored up by 50% to match the increased blast resistance of 

smaller windows of about 1 square metre. The line load for fixings may be factored down by 25% to 

15kN per metre of perimeter for windows of about 4 square metres overall area; but the 7kN per 

square metre should not be significantly reduced when designing the frames of large glazing systems. 

Panes with an edge dimension of 1m or more should be provided with a frame having a glazing 

rebate of at least 35mm giving a bearing of 30mm. Greater protection may be provided by setting the 

pane in double‐sided adhesive security glazing tape or ideally bonded in sealant. 

If robust frames and deep rebates cannot be provided, a level of protection equivalent to anti‐shatter 

film on plain glass with net curtains can be achieved using thinner laminated glass, e.g. 6.8mm thick. 

In double glazing, the preferred standard is a 7.5mm laminated glass inner pane with a 6mm 

toughened glass outer pane in a robust frame with deep rebates. 

The same design loads may be applied as mentioned above. Users may elect merely to limit the 

spread of flying glass fragments by using laminated glass in less robust, standard frames. In this case 

the laminated inner pane may be reduced to 6.8mm thick (with 0.76mm pvb), with a 4mm toughened 
outer layer where panes are less than about 2 square metres. Even with standard frames some 

attention should be given to the strength of fixings of the frame to the surrounding structure. It is 

recommended that fixings should be designed to resist not less than 25% of the values given above, 

i.e. not less than 5kN per metre. Fixings should be at a maximum of 350mm centres. 

Many large glazing facades are now being designed using ‘fixed point’ or ‘planar’ fixings. Where a 

level of blast resistance is required CPNI has developed a specification for specifying such fittings. As 

with all blast related enhancements the fittings must be considered in conjunction with a correctly 

designed façade system which must be checked by façade designers/engineers competent in the field 

of blast design. Suitable engineers should be members of the Register of Security Engineers and 

Specialists (RSES) (www.rses.org.uk) or be able to demonstrate that they meet the appropriate RSES 

competences. 

Before undertaking any improvements seek specialist advice through your police Counter Terrorism 

Security Adviser. 