Professional Documents
Culture Documents
MINI POWER
Primary switched-mode power supply
units
Easy-to-maintain connection
method thanks to the COMBICON
connectors.
MINI 5 V DC/3 A
1 AC
Wide-range Input:
In case of power supply units with a wide-
range input, the input voltage should not be
UP
selected. The loadable components are Width 22.5 mm Ex: U
designed for an expanded input voltage
range that covers the most important
supply networks worldwide. Compared to
L (+)
power supply units with fixed voltage input, NC
power supply units with wide-range input NC
N (-)
continue to function even in case of intense
voltage fluctuations due to unstable supply
networks.
Connection data solid stranded
[mm2] AWG
Input 0.2-2.5 0.2-2.5 24-12 M3
Output 0.2-2.5 0.2-2.5 24-12 M3
Pcs. /
Description Type Order No.
Pkt.
Power supply unit, primary switched-mode
MINI-PS-100-240AC/ 5DC/3 2938714 1
Technical data
Input data
Input nominal voltage range 100 V AC ... 240 V AC
Input voltage range AC/DC 85 V AC ... 264 V AC / 90 V DC ... 350 V DC
Frequency range 45 Hz ... 65 Hz / 0 Hz
Current consumption (nominal load) Approx. 0.4 A (120 V AC) / 0.2 A (230 V AC)
Inrush current limitation at 25°C (typ.) / I2t < 15 A / 1.5 A2s
Mains buffering (IN, typ.) > 30 ms (120 V AC) / > 140 ms (230 V AC)
Input fuse 2 A (slow-blow, internal)
Recommended backup fuse, LS switch 6 A, 10 A, 16 A (characteristic B)
Output data
Nominal output voltage 5 V DC ±1%
Setting range of the output voltage 4.5 V DC ... 5.5 V DC (> 5 V constant capacity)
578 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370
Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INTERFACE Power Supply
MINI POWER
Uu Uu UuP
Width 45 mm Ex: U Width 67.5 mm Ex: U Width 45 mm Ex: U
DC OK
Connection data solid stranded Connection data solid stranded Connection data solid stranded
[mm2] AWG [mm2] AWG [mm2] AWG
Input 0.2-2.5 0.2-2.5 24-12 M3 Input 0.2-2.5 0.2-2.5 24-12 M3 Input 0.2-2.5 0.2-2.5 24-12 M3
Output 0.2-2.5 0.2-2.5 24-12 M3 Output 0.2-2.5 0.2-2.5 24-12 M3 Output 0.2-2.5 0.2-2.5 24-12 M3
Signal 0.2-2.5 0.2-2.5 24-12 M3
4 kV (type test) / 3 kV (routine test) 3 kV (type test) / 3 kV (routine test) 4 kV (type test) / 3 kV (routine test)
Conformance with EMC guideline 2004/108/EC and for low-voltage Conformance with EMC guideline 2004/108/EC and for low-voltage Conformance with EMC guideline 2004/108/EC and for low-voltage
guideline 2006/95/EC guideline 2006/95/EC guideline 2006/95/EC
EN 60950/VDE 0805 (SELV), EN 61558-2-17 EN 60950/VDE 0805 (SELV), EN 61558-2-17 EN 60950/VDE 0805 (SELV), EN 61558-2-17
EN 50178/VDE 0160 (PELV) EN 50178/VDE 0160 (PELV) EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410, DIN VDE 0106-1010 DIN VDE 0100-410, DIN VDE 0106-1010 DIN VDE 0100-410, DIN VDE 0106-1010
UL/C-UL listed UL 508, UL/C-UL Recognized UL 60950, UL/C-UL UL/C-UL listed UL 508, UL/C-UL Recognized UL 60950, UL/C-UL UL/C-UL listed UL 508, UL/C-UL Recognized UL 60950, UL/C-UL
Listed UL 1604 Class I, Division 2, Groups A, B, C, D Listed UL 1604 Class I, Division 2, Groups A, B, C, D Listed UL 1604 Class I, Division 2, Groups A, B, C, D
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 579
Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com