Professional Documents
Culture Documents
Inter-U 2018 - Case Study - Presentation - DDLSCorp PDF
Inter-U 2018 - Case Study - Presentation - DDLSCorp PDF
of a Wastewater
Sedimentation Tank Using
Case Study Analysis
DDLSCorp
HELLO!
We are DDLSCorp
2
CONTENTS
B A C K GR O U N D O F T H E S T U D Y
D E S I G N A P P R O A CH
M E T H OD S O F S O L U T I O N
R E S U L TS A N D A N A L Y S I S
C O N C L U S I ON 3
BACKGROUND
OF THE STUDY
http://www.butec.com.lb/activities/tripoli-wastewater-treatment-plant/
5
10%
percentage of wastewater that is treated
58%
percentage of contaminated groundwater
5%
of the total population is connected to a
sewer network 6
𝟑
2,000
Solvent wastes
𝒎
22,000 tons
Heavy metals, infectious wastes, biological
sludge, lubricants and intractable waste
𝟑
25,000,000
Acid/alkaline wastes
𝒎
7
“The State shall pursue a
“ policy of economic growth in
a manner consistent with the
protection, preservation and
revival of the quality of the
country’s fresh, brackish and
marine waters”
Detention time, t, is
𝑯 equal to the height
𝒕= divided by the overflow
𝑽𝒐 rate.
16
EQUATIONS USED
17
EQUATIONS USED
19
METHODS OF
SOLUTION
n 𝐃𝐩,𝐚𝐯𝐞 , µm 𝐔𝐬, m/hr 𝐔𝐬 /𝐕𝐬 particles particles
removed remaining
1 11.5 0.439 0.301 9.031 20.969
2 19 1.198 0.822 41.087 8.913
3 24.5 1.993 1.000 90 0
4 29.5 2.889 1.000 110 0
5 32 3.837 1.000 100 0
6 37.5 4.668 1.000 70 0
7 40.5 5.445 1.000 30 0
8 43 6.138 1.000 20 0
Total 470.119 29.881
21
EQUATIONS USED
22
EQUATIONS USED
Fraction of particles
𝑼𝑺 removed
𝑽𝑺
23
EQUATIONS USED
24
Case Conditions
1 Constant Height Varying Diameter
2 Varying Height Constant Diameter
3 Varying Height Varying Diameter
33
PROMETHEE
Interface
34
CONCLUSION
Parameters Specifications
Treatment Primary
Geometry Circular
Diameter, Height 67 m, 3 m
Critical Overflow Rate 28.36 m3/m2-day
Removal Efficiency 96.23%
Construction Material Stainless Steel (SS304L)