AZZ Segregated Bus Bar Segregated Bus installed alongside Isolated Phase Bus in Saudi Arabia
Custom Bus Duct Solutions The Ideal Bus Solution for Standard Features
Developed for the most demanding Rugged Applications Rugged design for long-term
industrial and power generation AZZ’s segregated phase bus systems reliable operation
environments, AZZ non-segregated are built to deliver decades of reliable Silver-plated contact surfaces for
phase bus represents an innovative service in some of the most hostile maximum conductivity
design that provides effective system environments. AZZ segregated bus Fluidized bed expoxy insulation
performance that’s cost-effective, represents an innovative design that Bus joints insulated with flame-
low maintenance and ensures greater provides consistent performance and retardent PVC boot
reliability than power cables provide. low maintenance. ISO 9001 certified
AZZ’s single-bar design means lower With voltages ranging from 600 Meets or exceeds IEEE, IEC and
installation costs, less hardware at volts to 38kV and ampere ratings up CSA standards, including ANSI
splice connections, and reduced install to 8,000 amps, this design utilizes C37.23 for safety and performance.
time. A 3-phase, 4-wire system (full single-phase conductors in a common
Customized Engineering
and half neutrals) and 2-pole DC bus enclosure with metal barriers between
phases. Copper or aluminum bus bar
provides added efficiency in a number
Aluminum or stainless steel housing
of applications.
Available bushing box terminations
Segregated Bus Applications
Cable tap box
Non-Seg Bus Applications Smaller generator lead-in power
Temperature maximum designed
Transformers to switchgear plants
to customer needs
Switchgear to switchgear Hydro plants
Seismic certifications available
Motor control centers Metal enclosed substations con-
Customized condensation control
AC and DC excitation necting to switchgear
Generator bus Transmission distribution substa- Supporting Services
tions Turnkey installation available
Engineered for Multiple
Complete on-site service and parts
Environments
Preventive maintenance programs
AZZ non-segregated bus systems are
available from 1200A through 5000A
and 600 volt to 38 kV and are perfect
for both indoor and outdoor locations.
Non-segregated systems are avail-
able with either copper or aluminum
painted or epoxy-coated conductors,
and are mounted on custom-molded,
fiberglass-reinforced polyester support
blocks or post insulators for maximum
performance and safety.