You are on page 1of 8

UPPER ARM AUTOMATIC

BLOOD PRESSURE MONITOR


Model: 2005

Blood Pressure Monitor

POWER
STAR
T

CMNP-1
TYPE:A

m
3c
2~

22-32-cm

INSTRUCTION MANUAL
TABLE OF CONTENTS INTRODUCTION
Thank you for purchasing the upper arm Automatic Blood Pressure Monitor. This
Introduction ..........................................................................................................................2 remarkable instrument is ideal for people who frequently monitor their own blood pressure
because it's easy to use. Simply push of a button the monitor measures your blood
Notes on safety ...................................................................................................................2 pressure and pulse and displays the reading on a clear digital panel. Perfect for quick, easy
A Few Words About Blood Pressure ....................................................................................3 readings at home, at work, almost anywhere!

Precautions Before Use ........................................................................................................6 The Monitor uses the oscillometric method of blood pressure measurement. This means
the monitor detects your blood's movement through the artery in your arm and converts the
Features of the Product .......................................................................................................6
movements into a digital reading. An oscillometric monitor does not need a stethoscope so
Main Unit .............................................................................................................................7 the monitor is simple to use and measurements are easy to obtain.
Insert or Replace Batteries ..................................................................................................7 Clinical research has proven a direct relationship between blood pressure in the wrist and
blood pressure in the arm. Changes in wrist blood pressure reflect changes in arm blood
Time and Date of System Setup .........................................................................................8
pressure because the arteries in the wrist and the arm connect. Frequently measuring the
How to Use the Upper Arm Cuff ...........................................................................................8 blood pressure in your arm will provide you and your doctor with an accurate indication of
changes in your actual blood pressure.
A Few Suggestions Before Measurement .........................................................................10
How to Measure Blood Pressure .......................................................................................10 The product complies with the electromagnetic compatibility requirement of EN60601-1-2
and safety standards of 60601-1 as specified in EEC directive 93/42/EEC.
Recalling Record ................................................................................................................12
Please read this instruction manual thoroughly before using the upper arm Automatic Blood
How to Maintain and Store the Unit ....................................................................................12 Pressure Monitor. For specific information on your own blood pressure, CONTACT YOUR
How to Prevent a Malfunction .............................................................................................13 DOCTOR.

Specifications .....................................................................................................................13
NOTES ON SAFETY
Troubleshooting ................................................................................................................. 14
* The warning signs and sample icons shown here are listed for your safe
and correct use of the unit, so as to prevent injuries or damages to the device.

* The icons and meanings are as follow.


Examples of signs

The icon indicates prohibitions (what you should not do).


Matters involving actual prohibitions are indicated by text or pictures in or
near . The left icon refers to "general prohibition".

The icon indicates something that is compulsory (What must always be observed).
Matters involving actual compulsory actions are indicated by text or pictures in
or near . The left icon refers to "general compulsion".

Type BF Applied part

Attention and read before use

-1- -2-
Caution Your heart is like a pump. When it contracts, or beats, it Heart Contracts
sends a surge of blood through the blood vessels and (Pressure Increases)
Self-diagnosis of measured results and treatment are dangerous. Please pressure increases. This is called your systolic
follow the instructions of your doctor. pressure.
Self-diagnosis may worsen the disease.
When your heart relaxes between beats, your blood
Do not use the unit for infants or person who cannot express one's intention. pressure decreases. This is called your diastolic
May cause accident or trouble. pressure.
Heart Relaxes
Do not use the unit for purpose other than measuring blood pressure. (Pressure Decreases)
May cause accident or trouble.
When a doctor takes your blood pressure, he or she
Do not use cellular phone near the unit. measures both your systolic and diastolic pressures Systolic
The main unit may operate erroneously. and records them as numbers. For example, if your (Upper Number)
blood pressure reading is 126/76 (126 over 76), your
Do not disassemble, repair, or remodel the main unit or the cuff of the blood systolic is 126 and your diastolic is 76. The numbers
pressure monitor. are calculated in millimetres of mercury and recorded
Will cause the unit to function erroneously. as 126/76 mm Hg.
Diastolic
These two numbers provide important information (Lower Number)
Requests from Manufacturer about your health. The more difficult it is for your blood
to flow through your blood vessels, the higher both
Used batteries may leak and damage the main unit. Please observe the following points. numbers will be. When blood pressure is consistently above normal it is called
* If you are not going to use the unit for a long period of time (approximately three hypertension (High blood pressure).
months or more), remove the batteries.
* Replace worn batteries with their polarities in the correct direction. The Blood Pressure Monitor automatically measures your systolic and diastolic blood
* Do not insert the batteries with their polarities in the wrong direction. pressure for you, then displays the results on easy-to-read digital panel!
Do not use force to bend the cuff or the air tube.
People with a condition that causes circulatory problems (diabetes, kidney disease,
When removing the air tube, please pull and hold at plastic plug. arteriosclerosis, or poor peripheral circulation) may get lower readings with wrist type
monitor than with a blood pressure monitor that is used on the upper arm. Please consult
Do not knock or drop the main unit.
your physician to determine if your wrist blood pressure accurately reflects your actual
Do not inflate the cuff when it is not wrapped on the upper arm. blood pressure.

Always use the specified accessories in the manual, the use of other parts not Your blood pressure changes constantly. Blood pressure fluctuates from day to day and
approved by the manufacturer may cause faults or injuries. minute to minute according to your body's needs. For example, when you are exercising or
For service information , parts list etc., please contact the dealer. angry your blood pressure increases, but when you are relaxing or sleeping your blood
pressure decreases. These fluctuations are completely normal. This blood pressure monitor
is especially helpful when tracking changes in your blood pressure because it takes just
A FEW WORDS ABOUT BLOOD PRESSURE seconds to use.

Blood pressure is the force exerted on the walls of your blood vessels as blood flows
through them.

-3- -4-
Fluctuation Within a Day
(Example: 35-year old male) Systolic (mmHg) Diastolic (mmHg)
300 Breakfast Normal less than 139 less than 89

Blood Pressure (mm Hg)


Dinner Sleeping Lunch
250 Borderline 140 to 159 90 to 94
Hypertension more than 160 more than 95
200 Systolic
Blood pressure
150 Note: There is not an universally accepted definition of hypotension (low blood pressure),
but a systolic pressure below 99 mmHg is usually regarded as hypotension.
100 Diastolic
Blood pressure
50
PRECAUTIONS BEFORE USE

0 1. Do not confuse self-monitoring with self-diagnoses. Blood pressure


measurements should only be interpreted by a health professional who is familiar with
5 pm 11 pm 5 am 11 am 5 pm
your medical history.
Time
2. If you are taking medication, consult with your doctor to determine the
most appropriate time to measure your blood pressure. NEVER change a prescribed
FACTORS THAT MAY CAUSE THE BLOOD PRESSURE TO FLUCTUATE medication without first consulting with your doctor.
3. For people with irregular or unstable peripheral circulation problems due
* Breathing * Exercise * Mental stress * Worries * Environmental and/or
temperature change * Eating * Urination and bowel movement * Talking * Taking to diabetes, liver disease, hardening of the arteries, etc., there may be fluctuation in
a bath * Drinking alcohol * Smoking, etc. blood pressure values measured at the upper arm versus at the wrist.
4. This device is designed for adults to use .If use this device on a child patient, old people
or toddlers, consult with your doctor or measure with relative aid.
Note: One or two readings will not provide a true indication of your normal blood pressure. 5. Measurements may be impaired if this device is used near televisions, microwave ovens,
It is very important to take regular, daily measurements and to keep accurate X-ray, mobile phone equipment or other devices with strong electrical fields. To prevent
records. In partnership with your doctor, an accurate record of your blood pressure such interference, use the meter at a sufficient distance from such devices or turn them
over a period of time can be a valuable aid in diagnosing and preventing potential off.
health problems. 6. This device is not suitable for disease diagnoses, urgent treatment, continuous monitoring
during medical emergencies or operations.
The World Health Organisation (WHO) developed the following Blood Pressure 7. Before using, should wash your hands.
Classification. This classification, however, is only a general guideline because blood 8. If there is too much pressure or you feel uncomfortable, please press "POWER" button
pressure varies from person to person according to age, weight, and health status. immediately for quick deflation.
CONSULT YOUR DOCTOR TO DETERMINE YOUR NORMAL BLOOD PRESSURE.

WHO Blood Pressure Classification


FEATURES OF THE PRODUCT
mm Hg 1. Uses the fuzzy-logic measurement.
Hypertension 2. Memory can store 128 measurements.
95 3. Easy to use buttons.
Borderline 4. Large and clear display.
90 5. Upper arm cuff is easy to wrap correctly.
Normal 6. Desktop style for easy measurement.
Diastolic 7. Easy to use, Press a button to automatically measure, recording the measurement
Systolic 140 160 mm Hg values and measurement time.
8. Automatically turns off (within 2.5 minutes) to save power.

-5- -6-
MAIN UNIT 5. When the battery icon displays on the LCD, please replace four new alkaline "AA"
batteries, please do not mix the new and old battery together.
6. If the unit will not be used for a long period, please take out all batteries to avoid liquid
7. POWER Button leakage damaging the unit.
1. Air Tube Hole 8. START Button
2. Blood pressure Display 9. Button (UP) For memory recall and SYMBOLS ON DISPLAY
3. Date and Time Display Date / Time adjust
4. Systolic Value 10. Button (DOWN) For memory MONTH/DATE HOUR/MINUTE
5. Diastolic Value recall and Date / Time adjust
6. Pulse/min Value 2
11. SET Button SYSTOLIC
1 SYS
12. Upper Arm Cuff MEMORY
VALUE OF SYSTOLIC
13 3 13. Air Tube DIASTOLIC DIA
INFLATION VALUE OF DIASTOLIC
DEFLATION
Blood Pressure Monitor
Kpa mmHg
UNIT OF PRESSURE
PULSE
LOW BATTERY -min
4

ATTENTION OF ERROR VALUE OF PULSE PER MINUTE

HEART BEAT PULSE UNIT


POWER 5
START
CMNP-1

12
9 TIME AND DATE OF SYSTEM SETUP
TYPE:A

6
3c
2~

22-32-cm

7
11 8
10 1. Press "POWER" key to turn on.
2. Press and hold "SET" key until the year number displays and flashes on LCD to enter
setting mode.
3. Press" " or " " key to adjust the year, then press " SET " key
INSERT OR REPLACE BATTERIES again to save your setting and enter the
month setting mode. SYS
During the battery symbol appears on the display or nothing is display while inflation during 4. Press " " or " " key to adjust the month.
measurement, you should replace with new batteries. Following the same steps to adjust date/hour/ DIA
1. Slide the battery cover in the direction of the arrow to open. minute until setting completed.
2. Insert four "AA" alkaline batteries in the correct polarity direction.
PULSE
Note: Please check and re-set Date/Time after -min
replacing of new batteries.

HOW TO USE THE UPPER ARM CUFF


Four "AA" alkaline batteries

1. Pass the end of the cuff (with sewn-in rubber


stopper) through the metal stirrup so that a
loop is formed. The Velcro closer must be
Disposal of empty battery to the authorized facing outwards. (Ignore this step if the cuff
collecting party subject to the regulation of has already been setup.)
each individual territory.

2. Push the cuff over the left upper arm so that


3. Replace the battery cover.
the tube points in the direction of the lower
4. With the use of four alkaline "AA" batteries, you can measure approximately 250 times
arm and palm.
at room temperature of 22 OC and inflating to around 170mmHg once a day. But the
included batteries only for test purpose may not last as specified long period.
-7- -8-
3. Lay the cuff on the arm as illustrated. Make 2~3cm (3/4~1") A FEW SUGGESTIONS BEFORE MEASUREMENT
certain that the lower edge of the cuff lies
approximately 2 to 3 cm (3/4~1") above the 1. Avoid eating, smoking, and exercising for at least 30 minutes before taking a measurement.
elbow and that the rubber tube leaves the cuff Also rest for at least 15 minutes before taking a reading.
on the inner side of the arm. 2. Stress raises blood pressure. Avoid taking measurements during stressful times.
Important! The mark (about 3 cm long bar) 3. You would better apply the cuff on your left upper arm.
must lie exactly over the artery which runs 4. Measurement should be taken in a quiet place and you should be relaxed, seated position.
down the inner side of the arm. Rest your left arm on a table.
5. Remain still and do not talk during the measurement.
6. Keep a record of your blood pressure and pulse for your doctor. Remember, a single
measurement does not provide an accurate indication of your true blood pressure. You
4. Tighten the free end of the cuff and close the need to take and record several measurements over a period of time. Try to measure
cuff with the closer. your blood pressure at the same time each day for consistency. Blood pressure
measurements fluctuate considerably.
7. Wait 5-10 minutes between successive measurements. Waiting allows the engorged blood
vessels to return to normal. You may require more rest time depending on your individual
5. There must be no free space between the arm physical conditions.
and the cuff as this would influence the result.
Clothing must not restrict the arm. Any piece of
clothing which does (e.g. a pullover) must be HOW TO MEASURE BLOOD PRESSURE
taken off.
1. Set up the cuff to your upper arm as previous section of "How to use the upper arm cuff".

2. Press the "POWER" button, all icons appear two seconds on DISPLAY, then switch to
6. Secure the cuff with the Velcro closer in such a measurement mode,and display "0" or last measurement record.
way that it lies comfortably and is not too tight.
Lay the arm on the table (palm upwards) so SYS SYS
that the cuff is at the same height as the heart.
Make sure that the tube is not kinked. POWER DIA DIA

PULSE PULSE
-min -min

7. Remain seated quietly for two minutes before


you begin the measurement. 3. Press "START" button to start measurement, the cuff in the strap will automatically inflate.
When the value on LCD increases to around 150-200 (mmHg), and start to release the
air, and decrease pressure in the cuff automatically when it senses the heart beat, the
mark ( ) will flash on LCD.

SYS
START SYS SYS SYS

DIA DIA DIA DIA

COMMENT:
If it is not possible to fit the cuff to the left arm, it can also be placed on the right arm. PULSE
-min
PULSE
-min
PULSE
-min
PULSE
-min
However all measurements should be made using the same arm for better cross reference.

-9- -10-
4. After measurement the screen will display systolic value, diastolic value, and pulse 2. Do not use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff.
per minute value, Then automatically store the measured record into memory.

5. Press "POWER" button again to turn off the unit.


* Even if you forget to press "POWER" button, the unit will turn
off automatically in approximately 2.5 minutes.
3. Before using please wash your hands. Do not wash or wet the cuff.
POWER
Blood Pressure Monitor

POWER
STAR
T

NP-1
TYPE:ACM

m
3c
2~

22-32-cm
Note: * The value measured will be too low if you hold your cuff higher than heart level, or
will be too high if you hold your cuff lower than heart level.
* The unit may store 128 measurement values, If more than 128 records, it will
delete the earliest data. 4. Avoid placing the unit where direct sunlight, high humidity or dust.
* During measurement do not speak or shake as which may affect the accuracy of
the result. Blood Pressure Monitor

* If you want to stop the measurement during measurement process, just press the
"POWER" button to stop immediately.
POWER
STAR

RECALLING MEMORY
T

NP-1
TYPE:ACM

m
3c
2~

22-32-cm
1. Press "POWER" button to turn on the unit.
2. Press " " button to review the first measurement in the memory. Repeatly Press " "
button to review memory data in descending order.
3. Press " " button to review the last measurement in memory. Repeatly press " " button Note: When the unit will not be used for a long period, be sure to remove the batteries,
to review memory data in ascending order. Otherwise, the batteries may leak and damage the unit.

HOW TO MAINTAIN AND STORE THE UNIT HOW TO PREVENT A MALFUNCTION

1. Use a dry soft cloth to clean the unit.. If necessary , use a cloth lightly dampened with tap 1. Do not drop the device and avoid sudden jars or shocks.
water. 2. Do not insert other objects into any holes.
3. Do not attempt to disassemble the unit.
4. Do not crush the pressure cuff.
Blood Pressure Monitor

5. If the unit has been stored at temperatures below 0 C, leave it in a warm place for 30 O

POWER
STAR
minutes before using it, otherwise, may get wrong messurement result.
T
NP-1
TYPE:ACM

m
3c
2~

22-32-cm

-11- -12-
SPECIFICATIONS TROUBLESHOOTING
If you have trouble in using the unit, please check the following points first.
Measuring Method: Oscillometric System
Indication: Digital LCD Display ERROR DISPLAY POSSIBLE CAUSE HOW TO CORRECT
Measuring Range: Pressure: 0~300mmHg, Pulse: 40~200 Beat/min. Nothing is displayed No battery installation Insert batteries
Accuracy: Pressure ±3mmHg; Pulse ±5% when you push the Battery worn out Replace new batteries
POWER button or The polarities of batteries Insert battery in the correct
Inflation Electric Pump Inflation
battery icon flash placed wrongly polarities
Deflation: Pressure Release Valve
E1: Can't normally Check your cuff if any air Replace cuff with new one
Memory: 128 Memories increase pressure leakage
Power Source: 1.5V "AA" x 4 Alkaline Batteries E2, E7,E8,E9: Arm cuff not properly adjust Renew adjust cuff position and
Battery Life: Approx. 250 Times (Once a Day, Room Temperature 22 C)
O
Measurement failure or placement, hand or body tightness, and keep hand still
Working temp. & Humidity: 40~104 F (5~40 C), 30~85% RH
O O shaking
E3. Inflate pressure too high Re-measurement or send back
Storage Temp. & Humidity: 4~140 F (-20~60 C), 10~95% RH
O O

dealer for re-calibrate pressure


Outside Dimensions: 112mm(W) x 140mm(D) x 70mm(H)
E4: Have shaking while Hand or body shaking while Keeping static and correct gesture
Weight: Approx. 534g (Apparatus and Battery) measurement measurement to measure again
Accessories: Cuff (fit arm size 22~32cm) , Instruction Manual E5: Automatically pressure Cuff too tight
Operation Voltage 6 V DC release too fast Readjust cuff and measure again
E6: Automatically pressure Cuff too loose
* Specifications may be changed without notice in the event of improvement being made. release too slow
Battery icon on Battery low power Replace battery, and measure again
1. The cuff was held lower
The systolic pressure than your heart
value or diastolic 2. The cuff was not
pressure value too high attached properly
3. You moved your body or Keeping correct position and
spoke during measurement gesture to measure again
1. The cuff was held higher
The systolic pressure than your heart
value or diastolic 2. You moved your body or
pressure value too low spoke during measurement.

Note: Relax for at least 10 minutes and then take another measurement.

611-200500-000

VER.1.1, 11/2006

-13- -14-

You might also like