You are on page 1of 13

PUMP SCHEDULE

REF : 1 BLOCK 20th STOREY OFFICE BUILDING @ SECTION 14, SHAH ALAM FOR JAKEL PROPERTIES SDN BH (BSN) – ORIGINAL DESIGN

PUMP PUMP EACH PUMP PUMP POWER


ITEM LOCATION APPLICATION ELECTRICAL QTY
BRAND TYPE PUMPING CAPACITY MODEL KW
CWTP-B2-1 & 2 Vertical Cold Water Transfer
1 Calgon 3.9 lit/sec Vs 68 m Head VR 12-80 5.5 kW 415v/3ph/50hz 2 nos
(Basement 2 Level) In-Line Pumps System
CWTP-L12-1 & 2 Vertical Cold Water Transfer
2 Calgon 1.4 lit/sec Vs 40 m Head VR 4-60 1.1 kW 415v/3ph/50hz 2 nos
(Level 12) In-Line Pumps System
VSD-R-1 & 2 Vertical Cold Water Booster
3 Calgon 1.3 lit/sec Vs 11.2 m Head VR 4-30 0.55 kW 415v/3ph/50hz 2 nos
(Roof Level) In-Line Pumps System
SP-1 & 2 to SP-7 & 8 Submersible Submersible Drainage
4 Calgon 5.7 lit/sec Vs 16 m Head CPC 220-2H 2.2 kW 415v/3ph/50hz 8 nos
(Basement 2 Level) (Free-Standing) Pumps Systems
Variable Speed Booster System
Energy Saving With Frequency Inverter Controlled System
Custom built to meet all kind of pumping needs

Complete System
ONE source
Easy-To-Operate Calgon Booster System

Calgon Variable Speed Booster Set is an advanced water supply pumping equipment which consists two or
more centrifugal pumps assembled in parallel and mounted on a common base frame. Calgon ready-to-
install system is designed to address the pressure needs of commercial and domestic water supply system.
The variable speed control function utilizing one or more frequency inverters to enable the pump system to
maintain a constant set pressure under varied water demand condition. The control system is equipped with
standard protective device on motor over-current and water shortage condition. Upon request, wireless
(GSM/GPRS) pump monitoring and reporting system can be incorporated to meet the specific requirement.
Water Supply

Water Supply
Pressure boosting system for high rise buildings, hotels,
condominiums, schools and other institutions.
Water supply system for waterworks and distribution system
for housing estate.

Irrigation
Irrigation for sport fields, golf courses and landscapes.
Irrigation

Orchard and agricultural plantation.


Parks and recreational areas.

Industry
Water supply for all kind of industries.
Industry

Water treatment plants and filtration system.

Advantages Of Choosing A Variable Speed System


• Space saving, effectively designed with small • Maintain constant pressure.
foot print to minimize floor space. • Reduction in water surge during pump stop.
• Energy saving, through energy-efficient • Demand very minimal maintenance.
variable speed controls.
• Ready to install, complete packaged system to
save time and money.
Variable Speed Booster System

Operating Conditions

Liquid temperature : 0°C to 75°C


Ambient temperature : 0°C to 40°C

The selection of pressure transmitter range is dependent on desired


system pressure for any specific pumping application.

Construction

• The Calgon variable speed system which consists of 2 or more centrifugal pump is built on a common
base frame.

• The control panel is fixed to the base frame with a mild steel support. For bigger kW motor, the control
panel can be supplied as separate entity.

• The control unit is fitted with frequency inverter(s), contactors, ventilation fan, pressure transmitter and
other necessary components as standard supply. Hydrologic pump controller is available upon
request.

• Suction and discharge manifold is mounted on both side of the pumps complete with isolating valves.
Non-return valve is installed on either the suction or discharge side of the pump subject to suction
condition.

• The manifold material and the type of valves used can be selected to suit client’s requirement.

Designation Quantity
Control Panel 1
Frequency Inverter 1 or more

HydrologicTM Controller (optional) 1


Pressure Transmitter 1
Suction Manifold 1

Discharge Manifold 1 HydrologicTM Controller


Non-Return Valve 1 Per Pump
HydrologicTM is an electronic unit capable
Isolating Valves 2 Per Pump of controlling one to six pumps. It receives
an input signal of 4 - 20 mA from pressure
Base Frame 1
transmitter and regulate the speed of
Pressure Gauge 1 duty pump via the frequency inverter(s) to
maintain constant pressure at discharge.
Diaphragm Tank 1 The operating status and set datas are
Calgon Vertical Multi-Stage Pumps 2-6 easily accessible through a large backlit
(other type of pumps can be supplied upon request) LCD display. Please refer to Hydrologic
catalogue for more information.
Variable Speed Booster System

Incoming

Diaphragm Tank

Outgoing

Pump Isolating Non-Return Pressure Pressure


Valve Valve Transmitter Gauge

Energy Saving
Head (M) Head (M)
60 60

N1 = 100 %

50 50
N2 = 80% 75%
78%
81%
(1) 83%
40 40
(2)
(2) 83%
H2 81%
78%
30 Set Pressure (1) 75%
30
H1

20 20

10 ` 10

0 0
0 20 40 60 80 100 120 0 20 40 60 Q1 Q2 80 100 120

Flowrate % Flowrate %

1. Pump characteristic curve at full speed of 100%. 1. Pump duty point at fixed speed with operating efficiency
of 78%
2. Operating point of pump under reduced speed of
80% while maintaining constant set pressure. 2. By using enlarge impeller, same pump duty point is
achieved by reducing motor speed. Higher operating
Saving of power consumption is achieved by: efficiency is achieved.
3
Affinity Law P1 = N1 Affinity Law Q1 = N1
P2 N2 Q2 N2
2
Where P = power, N= motor speed H1 = N1
H2 N2

Where Q= flow rate, N= motor speed,


H= pressure
Version 2/2009
The Submersible Series
CPC/CPS /DP -suitable for industrial, commercial and domestic

waste water/ sewage pumping.


CPC / CPS Submersible Sewage pump

The Calgon range of CPC / CPS Submersible pumps are suitable for sewage and waste water applications.
Suitable for pumping of liquid containing solid of fibrous material. Widely adapted in the industrial, commercial
as well as the industrial sectors.
Type of Installation

Fixed Installation :Pumps are supplied with quick discharge coupling for ease of dismantling
for maintenance.
Portable Installation :Pumps are supplied with pump foot / base suitable for free standing installation.
Technical Data
Head (maximum) : 40 m
Capacity (up to) : 210 m3/Hr
Temperature (max) : 40oC
Type of pumped medium : Waste and sewage water containing solid or fibrous material.
Application

 Raw Sewage and Sludge pumping  Basement drainage


 Water Treatment Plants  Commercial application
 Storm Water discharge  Domestic use
 Drainage pumping station  Industrial Waster water

Materials of Constructions *

Parts Standard Materials of Construction

Casing Cast Iron FC 20

Shaft Stainless Steel SUS 316

Impellers Cast Iron C 20

Fasteners Stainless Steel SUS 304

* Special material variant upon request.

Type Designation

(S) : Single Phase 2 : 2 pole motor (A) : Automatic Version


4 : 4 pole motor

CPC (S) 550 - 4 H (A)

Cutter Series : P2 x 10W S : Small impeller


M : Medium impeller
L : Large impeller
Design Features of the Calgon CPC / CPS Submersible pumps

Control Box
Cables
Built in control box with integrated
Special indicator light available on end of
circuit ready to be connected to
cable. Red : Power on
float switch if required.
Yellow : Leakage

Motor
Squirrel Cage Submersible motors with Bearings
built in thermal sensors as option to cut off Sealed for life maintenance
pumps operation in event of over heating. free ball bearings..
1 ph / 240 V / 50 Hz
3 ph / 415 V/ 50 Hz
Mechanical Seal
Maintenance free,
specially design double mechanical
seal of tungsten carbide material
independent of direction of
rotation.

Oil Chamber
Specially designed with built
in sensor to detect
mechanical seal leakage.

Cutter
Cutter to enable handling of
solid or fibrous material.
Impeller
Open single
channel impeller
with built in
cutter provides
best handling of
solid and fibrous
material
DP Submersible Drainage pumps

The Calgon range of DP Submersible pumps are suitable for waste water drainage. Impellers are semi – open suitable
for clear and waste water containing solid particles. The motors are provided with a built in thermal sensor switch
to automatically cut off the motor in order to prevent overloading of motor. Double mechanical seals design protects
To prevent water from sipping into motor unit.

Float switch are supplied as part of the automatic versions.

Technical Data

Head (maximum) : 32 m
Capacity (up to) : 40 m3/Hr
Temperature (max) : 40oC
Type of pumped medium : Waste water containing solid particles.

Application

 Sludge pumping  Basement drainage


 Water Treatment Plants  Commercial application
 Storm Water  Domestic use
 Drainage pumping station  Industrial Waster water

Materials of Constructions *
Parts Standard Materials of Construction

Casing Cast Iron FC 20

Shaft Stainless Steel SUS 316

Impellers Cast Iron C 20

Fasteners Stainless Steel SUS 304 * Special material variant upon request.

Type Designation

Nominal head (A) : Automatic Version

DP 6 - 20 - 0.75 (A)

Drainage Series Nominal Flow rate Motor kW

You might also like