IMPORTANT
Identification FM Approved
LPCB Approved
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
Numbers NYC Approved
(Refer to Table A for complete approval
regulatory and health information. TY3331. . . . . . . . . . . . . . . . Horizontal information including corrosion resistant
TY3431. . . . . . . . . . . . . . . . . . Vertical status.)
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER Maximum Working Pressure
WARNING” that provides cautions Refer to Table B
with respect to handling and instal- Discharge Coefficient
lation of sprinkler systems and com- K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2 )
ponents. Improper handling and
installation can permanently damage Temperature Ratings
a sprinkler system or its compo- Refer to Table A
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
DEFLECTOR DEFLECTOR
1 - Frame HAT 5 1 - Frame HAT 5
2 - Button 2 - Button
3 - Sealing 3 - Sealing
Assembly Assembly
4 - Bulb 4 - Bulb
5 - Compression 5 - Compression
Screw Screw
6 - Deflector * 6 - Deflector *
6* 4 2 3 1 6* 4 2 3 1
STYLE 10 or 20 STYLE 10
RECESSED RECESSED
ESCUTCHEON ESCUTCHEON
Finishes
Sprinkler: Refer to Table C
Poly-Stainless
Physical Characteristics Design
Criteria
Frame �������������������������������������������������������Bronze
Recessed Escutcheon: Signal or Pure Button. . . . . . . . . . . . . . . . . L316 Stainless Steel*
White, Jet Black, Grey Aluminum, Chrome Bulb ������������������������������������������������������������� Glass
Plated, or Brass Plated Compression Screw ����������L316 Stainless Steel* The Series TY-FRB, 5.6 K-factor, Hor-
HSW Deflector ��������������������������� Copper/Bronze izontal and Vertical Sidewall Sprin-
Physical Characteristics Sealing Assembly. . Gold Plated Beryllium Nickel
Frame �������������������������������������������������������Bronze w/TEFLON
klers are intended for fire protection
Button ������������������������������������������� Brass/Copper *Type L316 stainless steel (UNS 31603) per ASTM systems designed in accordance with
Sealing Assembly. . Beryllium Nickel w/TEFLON A479/479M or BS EN 1008 WN1.4404. the standard installation rules rec-
Bulb ������������������������������������������������������������� Glass ognized by the applicable Listing or
Compression Screw ���������������������������������Bronze
HSW Deflector �����������������������������������������Bronze Operation Approval agency (e.g., UL Listing is
VSW Deflector ������������������������������������������ Copper based on the requirements of NFPA
The glass bulb contains a fluid which 13, and FM Approval is based on the
expands when exposed to heat. When requirements of FM’s Loss Prevention
the rated temperature is reached, the Data Sheets). Only the Style 10 or 20
fluid expands sufficiently to shatter the Recessed Escutcheon, as applicable,
glass bulb, allowing the sprinkler to is to be used for recessed horizontal
activate and water to flow. installations.
TFP176
Page 3 of 6
Installation * Temperature
rating is
** Pipe thread
connections
1 - Frame
2 - Button
4 - Bulb 7 - Ejection
5 - Compression Spring
The Series TY-FRB, 5.6 K-factor, Hori- indicated on per ISO 7-1 can 3 - Sealing Screw
zontal and Vertical Sidewall Sprinklers Deflector. be provided on Assembly 6 - Deflector *
must be installed in accordance with special request.
this section.
ARROW MUST
General Instructions POINT AWAY
Do not install any bulb type sprinkler 7/16" FROM AND BE
if the bulb is cracked or there is a loss ESCUTCHEON (11,1 mm) PERPENDICULAR
of liquid from the bulb. With the sprin- PLATE SEATING NOMINAL TO THE BACK
kler held horizontally, a small air bubble SURFACE 1/2" ** MAKE-IN WALL SURFACE
should be present. The diameter of the NPT
air bubble is approximately 1/16 in. 6*
(1,6 mm) for the 135°F (57°C) to
3/32 in. (2,4 mm) for the 286°F (141°C) 5
temperature ratings. FLOW
5/8±1/4"
(15,9±6,4 mm)
FIGURE 5
CLOSURE W-TYPE 6
SPRINKLER WRENCH
2-7/8" DIA.
(73,0 mm)
SERIES
TY-FRB 2-1/4" DIA. WRENCH
(57,2 mm) RECESS
MOUNTING
PLATE
1/8"
(3,2 mm)
PUSH WRENCH
1-1/4" (31,8 mm) 3/4" (19,1 mm) IN TO ENSURE
3/4" (19,1 mm) 1/4" (6,4 mm) ENGAGEMENT
WITH SPRINKLER
FIGURE 3 WRENCHING AREA
SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT FIGURE 6
STYLE 10 RECESSED ESCUTCHEON W-TYPE 7 RECESSED
SPRINKLER WRENCH
1/2±1/8"
(12,7±3,2 mm)
FACE OF
MOUNTING
SPRINKLER
SURFACE
FITTING
CLOSURE
2-7/8" DIA.
(73,0 mm)
SERIES
TY-FRB 2-1/4" DIA.
(57,2 mm)
MOUNTING
PLATE
1/8"
(3,2 mm)
FIGURE 4
SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
TFP176
Page 5 of 6
TABLE A
LABORATORY LISTINGS AND APPROVALS
damaged by dropping, striking, wrench Thereafter, annual inspections per ing contractor or product manufacturer
twist/slippage, or the like, must be NFPA 25 should suffice; however, with any questions.
replaced. Also, replace any sprikler instead of inspecting from the floor It is recommended that automatic
that has a cracked bulb or that has lost level, a random sampling of close-up sprinkler systems be inspected, tested,
liquid from its bulb. (Ref. Installation visual inspections should be made, so and maintained by a qualified Inspec-
Section). as to better determine the exact sprin- tion Service in accordance with local
kler condition and the long term integ-
The owner must assure that the sprin- requirements and/or national codes.
rity of the corrosion resistant coating,
klers are not used for hanging any
as it may be affected by the corrosive
objects and that the sprinklers are only
conditions present.
cleaned by means of gently dusting
with a feather duster; otherwise, non- The owner is responsible for the
operation in the event of a fire or inad- inspection, testing, and maintenance of
vertent operation may result. their fire protection system and devices
in compliance with this document, as
Frequent visual inspections are rec-
well as with the applicable standards
ommended to be initially performed
of the National Fire Protection Asso-
for corrosion resistant coated sprin-
ciation (e.g., NFPA 25), in addition to
klers, after the installation has been
the standards of any other authorities
completed, to verify the integrity
having jurisdiction. Contact the install-
of the corrosion resistant coating.
TFP176
Page 6 of 6
SPRINKLER FINISH
NOTES:
1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in
Canada (C-UL); and, the Approval by the City of New York.
TABLE B
MAXIMUM WORKING PRESSURE
P/N 57 – XXX – X – XXX
SPRINKLER TEMPERATURE
SIN FINISH RATINGS
9 CHROME PLATED
NOTES:
1. Available for TY3331 only.
2. Eastern Hemisphere sales only.
3. Available in 155°F (68°C) or 200°F (93°C
temperature rating only.
TABLE C
PART NUMBER SELECTION
SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
TEFLON is a registered trademark of DuPont