You are on page 1of 12

Replacement Instructions

Model FAR-2127/2827/2827W
FCR-2127/2827/2129-BB/2829
When changing the driving system of the magnetron from the constant-current to the constant-voltage, re-
place the pulse transformer and the MD board with referring to this instruction and the service manual
(Ref. No.: SME-35190-*).
Use the check sheet on the page 6 to confirm all required steps of the installation are completed.
Note: When replacing from 03P9244J to 03P9244K, refer to technical information (T3-2018-005).

1. How to replace the pulse transformer (RT-9023 to RT-9023A)


Contents of MD Replacement kit (Code: 001-520-230)

Name Type Code Qty. Remarks


MD Board 03P9244K(LF) 001-520-240 1

Pulse Transformer Assembly RT-9023A 001-467-410 1 With Capacitor

Resistor Mounting Bracket 03-154-5624-0 100-411-770-10 1

Washer Head Screw M4x10 000-163-206-10 4


C2700W MBNI2

Label (Transmit High Voltage) 03-154-5625-1 100-414-271-10 1 For FAR-2827W


RTR-081/A)

Label (Caution) 03-154-5626-1 100-414-281-10 1 For FAR-2127/2827/


FCR-2127/2827/2129-
BB/2129 (RTR-079/A)

1. Refer to “2.2 Scanner Unit” of the service manual and open the scanner unit cover.

Scanner unit cover

www.furuno.com
2. Refer to “2.2 Scanner Unit” of the service manual and pull out the RF unit from the scanner unit
.

Cover
View point from RF unit
“Figure-A”

3. Unfasten the cover of the RF unit.

(Figure-A)

03P9244 (Old type)

View point from “Figure-C”


(See Page 4)

View point from “Figure-B”


(See Page 3)

Magnetron RT-9023 (Old type)

2
4. After removing the cover, de-solder the pulse transformer (RT-9023) and remove the magnetron and
diode See “a” in Figure-B .
5. De-solder resistor R801 and remove the diode See “b” in Figure-B .
6. Unfasten the washer head screw (M3x8, 1 pc.) attached to R801, then remove R801 See “c” in Fig-
ure-B .
7. Unfasten the washer head screws (M4x8, 4 pcs.) attached to RT-9023, then remove RT-9023 See
“d” in Figure-B .

(Figure-B)

a RT-9023

Magnetron
Diode
b c

R801
d

8. Place the resistor mounting bracket where the R801 was located See “e” in the following figure .
Resistors are attached to the bracket beforehand.
9. Place the supplied RT-9023A on the resistor mounting bracket See “f” in the following figure .
10. Secure the supplied RT-9023A and resistor mounting bracket to the chassis with the supplied washer
head screws (M4x10, 4 pcs. See “g” in the following figure).
11. Solder the diode, magnetron and capacitor to the supplied RT-9023A See “h” in the following figure .

e
f

h
g

Diode
Magnetron

Capacitor

3
12. Solder the resistor to the diode (See “j” in the following figure)..

RT-9023A

j
Diode Resistor

2. How to replace the MD board (03P9244B/F/H to 03P9244K)


1. See the step a to d in below, remove the 03P9244B/F/H board with its chassis from the RF unit.
Note: Do not discard the screws unfastened from the board.

(Figure-C) a. Disconnect all connectors (See “a” in the following figure. 6 pcs.).
b. Unfasten flat head tapping screws (M4x15, 3 pcs., See “b” in the following figure).
c. Unfasten flat head tapping screws (M4x10, 4 pcs., See “c” in the following figure).
d. Unfasten flat head tapping screws on the outside of the cover
(M4x10, 2 pcs., not shown below).

c
c c
a
a
b b b

a
a c

a
a

2. Fit the 03P9244K board and chassis at the old MD board location, referring to the above figure
for fastening locations.
3. With the board and chassis fastened, connect all connectors (See “e” in the following figure. 6 pcs.).

Note: For 03P9244B replacements, connection to


the J816 connector is not required, as there
is no harness.

e e For 03P9244F/H replacements, connection


e to the J816 connector is required, as there
is a harness.

e
e
e

4
4. Remove labels on amplifier case and replace them to supplied labels..

RTR-081 label position


RTR-079 label position

5
Check Sheet for MD Board Replacement Work
1. MD Board Replacement Work
Item Contents Done Not
1 Replacing Replace it with a new pulse transformer: RT-9023A. ‫ڧ‬ ‫ڧ‬
pulse transformer Mount a resistor mounting bracket and new pulse ‫ڧ‬ ‫ڧ‬
transformer.
Connect a resistor (82Ω/20W) and new pulse ‫ڧ‬ ‫ڧ‬
transformer.
Solder the diodes at A part and B part.
2 Replacing MD board Replace it with the 03P9244K. ‫ڧ‬ ‫ڧ‬
3 Replacing magnetron Replace it with a magnetron with “*” mark ‫ڧ‬ ‫ڧ‬
(S/No.67031 or after)
4 Updating software for Update it to 0359202-G1.48. ‫ڧ‬ ‫ڧ‬
RFC board Check that the RFC software version is 0359202-G1.48. ‫ڧ‬ ‫ڧ‬
5 Adjusting TX high Turn VR1 of potentiometer to the lower limit ‫ڧ‬ ‫ڧ‬
voltage (turn VR1 and set TX-HV to the lower limit).
Set to 520-530 V in the L pulse TX mode. V
6 Checking pictures and Check as follows: ‫ڧ‬ ‫ڧ‬
tune - Pictures appear in the S1 to L pulse modes.
- Tune works properly.
7 Changing Labels Change labels on amplifier case to followings (supplied): ‫ڧ‬ ‫ڧ‬
- Label (Transmit High Voltage) 03-154-5625-1
(For FAR-2827W/RTR-081/A))
- Label (Caution) 03-154-5626-1 (For FAR-2127/2827/
FCR-2127/2827/2129-BB/2129/RTR-079/A)
2. Checking Spare Parts
Item Contents Done Not
1 Magnetron Check whether the spare magnetron for the ship indicates ‫ڧ‬ ‫ڧ‬
“*” mark.
Explain “Magnetrons with * mark must be used.” to the ‫ڧ‬ ‫ڧ‬
ship responsible person.

3. Information

Implementation Date: 䚷 Technician Name:

6
MD 基板交換作業   チ ェ ッ ク シー ト
1. MD 基板交換作業
項目 内容 実施 未実施
1 パル ス ト ラ ン ス交換 新パル ス ト ラ ン ス RT-9023A に交換 □ □
抵抗取付け板 と 新パル ス ト ラ ン ス の取付け □ □
抵抗 (82Ω/20W) と 新パル ス ト ラ ン ス の接続 □ □
A 部、 お よ び B 部のダ イ オー ド の半田付け
2 MD 基板交換 03P9244K に交換 □ □
3 マ グネ ト ロ ン交換 「*」マー ク 付 き マ グネ ト ロ ンに交換 □ □
(S/NO.67031 以降 )
4 RFC 基板の 0359202-G1.48 に更新 □ □
ソ フ ト 更新 RFC の ソ フ ト バージ ョ ン が □ □
0359202-G1.48 であ る こ と を確認  
5 送信高圧調整 ポテ ン シ ョ メ ー タ VR1 を下限い っぱいに回す □ □
(VR1 を回 し て TX-HV 電圧を調整下限にす る )
L パル ス送信時に 520 ~ 530V に設定 V
6 映像 と 同調確認 ・ S1 ~ L パル ス で映像が出 る こ と □ □
・ 同調が と れてい る こ と
7 貼 り マー ク 変更 キ ッ ト 支給の以下の貼 り マー ク を RF 部の □ □
ア ン プケース に貼 り 付け る
・ 貼 り マー ク (送信高圧) : 03-154-5625-1
(対象機種 : FAR-2827W/RTR-081/A 用)
・ 貼 り マー ク (注意) : 03-154-5626-1
(対象機種 : FAR-2127/2827/FCR-2127/2827/2129/
RTR-079/A 用)
2. 予備品の確認
項目 内容 実施 未実施
1 マ グネ ト ロ ン 本船の予備品のマ グネ ト ロ ン が*マー ク 付 き か確認 □ □
「*マー ク 付 き マグ ネ ト ロ ン を使用す る こ と 」を □ □
本船責任者へ説明

3. 連絡事項

実施日                                     技術者氏名                                

6
4. RF 部のア ン プケースか ら貼 り マー ク を剥が し 、 同 じ 場所に支給の貼 り マー ク を貼 り 付けます。

㻾㼀㻾㻙㻜㻤㻝㻛㻭 ㈞䜚䝬䞊䜽఩⨨
㻾㼀㻾㻙㻜㻣㻥㻛㻭 ㈞䜚䝬䞊䜽఩⨨

5
12. 抵抗 と ダ イ オー ド を半田付け し ます (下図 j を参照) 。

㻾㼀㻙㻥㻜㻞㻟㻭㻌


䝎䜲䜸䞊䝗 ᢬ᢠ

2. MD 基板 03P9244B/F/H を 03P9244K へ交換


1. 下図の手順 a ~ d を参照 し て、 03P9244B/F/H を シ ャ ーシ ご と RF 部か ら取 り 外 し ます。
注)取り外したネジは廃棄しないでください。

䠄෗┿ 㻯䠅 㼍㻚㻌඲䝁䝛䜽䝍䞊䛾᥋⥆䜢እ䛩 䠄ୗᅗ 㼍 䜢ཧ↷䚸 ྜィ 㻢 䞃ᡤ䠅㻌䚹


㼎㻚㻌䝘䝧䝉䝮䝇䝛䝆㻌㻔㻹㻠㽢㻝㻡䚸 㻟 ᮏ 㻕 䜢ྲྀ䜚እ䛩 䠄ୗᅗ 㼎 䜢ཧ↷䠅䚹
㼏㻚㻌䝘䝧䝉䝮䝇䝛䝆㻌㻔㻹㻠㽢㻝㻜䚸 㻠 ᮏ 㻕 䜢ྲྀ䜚እ䛩 䠄ୗᅗ 㼏 䜢ཧ↷䠅䚹
㼐㻚㻌䜹䝞䞊እഃ䛾䝘䝧䝉䝮䝇䝛䝆㻌㻔㻹㻠㽢㻝㻜䚸 㻞 ᮏ䚸 ᅗእ 㻕 䜢ྲྀ䜚እ䛩䡝

㼏 㼏 㼍

㼏 㼍
㼎 㼎 㼎

㼍 㼏
㼍 㼍

2. 取 り 外 し た 03P9244B/F/H を シ ャ ーシ ご と 支給の 03P9244K に交換 し 、 上図を参照 し て


ネジ で RF 部に固定 し ます。
3. シ ャ ーシ を固定 し た後、 コ ネ ク タ ーを接続 し ます (下図 e を参照、 合計 6 ヵ 所) 。

ὀ 㻕㻌㻜㻟㻼㻥㻞㻠㻠㻮 䛛䜙ኚ᭦䛾ሙྜ䛿 㻶㻤㻝㻢 䛾䝝䞊䝛䝇䛜


䚷䚷䚷䛺䛔䛾䛷䚸 㻾㻲㻯 ᇶᯈ䛛䜙䝁䝛䜽䝍䞊 㻶㻤㻝㻢 䜈䛾
䚷䚷䚷᥋⥆䛿୙せ䛷䛩䚹
㼑 㼑
㼑 㻌㻌㻌㻌㻌㻌㻜㻟㻼㻥㻞㻠㻠㻲㻛㻴 䛛䜙ኚ᭦䛾ሙྜ䛿䚸 㻶㻤㻝㻢 䛾
䚷䚷䚷䝝䞊䝛䝇䛜䛒䜛䛾䛷 㻾㻲㻯 ᇶᯈ䛛䜙
㼑 䚷䚷䚷䝁䝛䜽䝍䞊 㻶㻤㻝㻢 䜈᥋⥆䛧䛶䛟䛰䛥䛔䡝


4
4. パルス ト ラ ン ス RT-9023 と マグネ ト ロ ン、 ダ イ オー ド を接続 し ている半田を除去 し 、 RT-9023 か ら
マグネ ト ロ ン と ダ イ オー ド を外 し ます (下図 a を参照) 。
5. 抵抗 R801 と ダ イ オー ド の半田を除去 し 、 R801 か ら ダ イ オー ド を外 し ます (下図 b を参照) 。
6. R801 を固定 し ている ナベセムスネジ (M3×8、 1 本 ) を外 し て、 R801 を取 り 外 し ます (下図 c を参
照) 。
7. RT-9023 を固定 し てい る ナベセムスネジ (M4×8、 4 本 ) を外 し て、 RT-9023 を取 り 外 し ます (下図
d を参照) 。

䠄෗┿ 㻮䠅

㼍 㻾㼀㻙㻥㻜㻞㻟㻌

䝎䜲䜸䞊䝗
䝬䜾䝛䝖䝻䞁 㼐 㼏

㼎 㻾㻤㻜㻝

8. R801 があ っ た位置に、 支給の抵抗固定板を置き ます (下図 e を参照)。


抵抗は、 あ らか じ め抵抗固定板に取 り 付け られています。
9. 抵抗固定板の上に、 支給の RT-9023A を置き ます (下図 f を参照) 。
10. 抵抗固定板 と 、 支給の RT-9023A を支給のナベセムスネジ (M4×10、 4 本 ) で共締め し ます
(下図 g を参照)。
11. マグネ ト ロ ン、 ダ イ オー ド 、 お よび コ ンデンサを支給の RT-9023A に半田付け し ます (下図 h を参
照)。


㼔 㼓

䝬䜾䝛䝖䝻䞁
䝎䜲䜸䞊䝗

䝁䞁䝕䞁䝃

3
2. サービ ス マニ ュ アルの 『2.2 空中線部』 を参照 し 、 空中線部か ら RF 部を取 り 出 し ます。

䜹䝞䞊
෗┿ 㻭 䛾どⅬ 㻾㻲 㒊

3. RF 部のカバーを取 り 外 し ます。

㻔෗┿㻭㻕

㻜㻟㻼㻥㻞㻠㻠㻌㻔ᑐ⟇๓㻕

෗┿㻯䠄㻠䝨䞊䝆ཧ↷䠅䛾どⅬ

෗┿㻮䠄㻟䝨䞊䝆ཧ↷䠅䛾どⅬ

䝬䜾䝛䝖䝻䞁
㻾㼀㻙㻥㻜㻞㻟㻌㻔ᑐ⟇๓㻕

2
MD 基板交換要領書
型式 FAR-2127/2827/2827/FCR-2127/2827/2829
マグネ ト ロ ンの駆動方式を定電流か ら定電圧に変更する場合は、 本キ ッ ト を使用 し て以下の手順でパル
ス ト ラ ン ス と MD 基板の交換を行います。 交換の際は、 サービ スマニ ュ アル (SMJ-35190-*) も 参照 し て
く だ さ い。
作業終了後は 6 ページのチ ェ ッ ク シー ト を使用 し 、 すべての作業を行 っ た こ と を確認 し て く だ さ い。
注)03P9244J から 03P9244K への交換手順は、技術情報(T3-2018-005)を参照してください。

1. パルス ト ラ ン ス RT-9023 を RT-9023A へ交換

MD 交換キ ッ ト ( コ ー ド 番号 : 001-520-230)
名称 型式 コード番号 数量 備考
MD 基板 03P9244K (LF) 001-520-240 1
パル ス ト ラ ン ス組立品 RT-9023A 001-467-410 1 コ ンデン サ付 き
抵抗固定板 03-154-5624-0 100-411-770-10 1
ナベセ ム ス ネジ M4x10 000-163-206-10 4
C2700W MBNI2
貼 り マー ク (送信高圧) 03-154-5625-1 100-414-271-10 1 対象機種 : FAR-2827W
(RTR-081/A 用 )
貼 り マー ク (注意) 03-154-5626-1 100-414-281-10 1 対象機種 : FAR-2127/2827/
FCR-2127/2827/2129
(RTR-079/A 用)

1. サービ ス マニ ュ アルの 『2.2 空中線部』 を参照 し 、 空中線部カバーを開けます。

✵୰⥺㒊䜹䝞䞊

www.furuno.com
Pub. No. C32-01607-B2
(1812, TEHI) FAR-2xx7/FCR-2xx7/2xx9 00019345911

You might also like