MERCEM

Continuous monitoring of mercury in flue


gases

Analyzers and Process Instrumentation


Cutting mercury emission with a tried and
proven system – the SiCK MaiHaK MERCEM

The US EPA‘s Clean Air Mercury Rule issued in 2005 is the first rule worldwide which seeks to
reduce mercury emissions from coal-fired power plants. The limits for Hg measurement are in
the very low ppb levels. PS 12A defines the high performance standards for Continuous Mercu-
ry Monitoring Systems required under Part 60 and Part 75 of the CFR.
SICK MAIHAK is able to meet these high standards. MERCEM is a very accurate, field-proven
system that monitors Mercury in flue gas on a continuous basis.

features
¸ Continuous measurement of
total Hg in flue gas (both metal-
lic and ionic Hg)
¸ Easy handling and low mainte-
nance
¸ Reliable and robust technology areas of application
with years of field experience
¸ Proven wet conversion techno- ¸ Continuous emissions monito-
logy ring at power plants (coal, etc.)
¸ High-temperature gas sam- ¸ Waste incineration including
pling, 370 °F, no loss of mer- hazardous, chemical or sewage
cury species in the sampling sludge
system ¸ Cement production
¸ Proven even after FGD systems ¸ Ore processing, metal extrac-
(saturated gas streams) tion

Our Expertise And Experience For Your Benefit

2 MERCEM | SiCK MaiHaK


Proven +++ Efficient +++ Accurate +++ Stable

Proven Experience

¸ More than 10 years of field expe-


rience in continuous mercury
measurements in flue gases.
¸ More than 100 installations
demonstrating outstanding techno-
logical performance and operational
reliability.

Efficient Performance

¸ During combustion process, mercury


is released as a compound and in
elemental form. To obtain a compre-
hensive record of emissions, total
mercury content in the flue gas must
be measured.
¸ 100% efficient conversion of mer-
cury oxides to elemental mercury
through the use of the tin (II) chlo-
ride reduction technique.

accurate technique Stable measurement

¸ Detection of very low concentrations ¸ No spectral cross interference – the ¸ Using Cold Vapor Atomic Absorption
can be achieved by adjusting the mercury analyzer is not in direct con- Spectroscopy (CVAAS) for analysis
duration of the enrichment process tact with the flue gas. This prevents ¸ Very high zero stability – baseline
(amalgamation). The measuring contamination from other flue gas measurement is carried out during
range as well as the detection limit components. every measurement cycle
can be varied and adjusted to meet
individual requirements. ¸ High span stability

SiCK MaiHaK | MERCEM 3


Mercury analysis – an overview

the MERCEM operates either Built for easy access and


handling
• as stand-alone unit
The front door at the system cabinet
allows optimal access to all componen-
ts for operating and servicing purposes.
Measuring gas Data The ACE control unit and the MFU hea-
sampling acquisition ting controller are integrated as
19“ slide-ins into the door of the sys-
PC, Analog
data tem cabinet and can be accessed via a
separate transparent door. This means
MERCEM
Mercury the system can be operated without
Hg opening the cabinet door.

All components inside the cabinet can


Data transfer
Sample be easily accessed for servicing. The
reservoir for reaction solution is placed
just behind the front door for ease of
• in combination with the MCS100E HW replacement.
multi-component analysis system

OMD41
Continuous operation due to
Dust Data
acquisition
self-diagnostics

PC, modem In case of a malfunction the measuring


Probe1 system switches automatically into
modbus
“stand-by” mode and is flushed with an
PC, analog inert gas stream. For trouble-free ope-
Probe2 data ration of all system components, like
MERCEM
Mercury the reactor, the flow meter and the ana-
Hg * lyzer are checked automatically.

Data transfer MCS100E HW *


Sample
* Example of multi-component installation

Economic efficiency
The MERCEM can be closed coupled to the MCS100E HW multi-component CEM
system. This saves duplicate sample extraction equipment which reduces the
cost of ownership.

4 MERCEM | SiCK MaiHaK


Sample preparation and analysis

Sample extraction amalgamation discharge lamp with high stability, a


sample gas cell and a photo diode de-
The sample pump draws the stack gas The first step in the analyzer is the tector. The automatic baseline correc-
into the system cabinet. All compo- amalgamation procedure. A precisely tion before each measuring cycle en-
nents, e.g. sampling probe, tubes, etc. defined volume of the sample gas is sures the reliability of the
that are in contact with the stack gas passed through a gold trap. The me- measurements.
are heated to 350 °F to avoid conden- tallic mercury is collected on the gold
sation and corrosion. trap by amalgamation. After the col-
Memory effects are minimized by the lection period, all of the deposited
high sample gas flow rate and high tem- mercury is released by rapid heating
perature. A second pump extracts a par- of the gold trap. The released mercu-
tial stream and feeds it to the mercury ry is carried into the cell of the pho-
measuring system. tometer by an inert gas flow for mea-
surement by atomic absorption. The
analyzer is ready for the next measur-
Reduction ing cycle after a cooling period

SnCl2 reaction solution is used to re-


duce the mercury compound to elemen-
tal mercury. Peristaltic pumps remove
excess condensation and add fresh re- Photometric measurement
action solution. A cooler unit dries the
gas and removes remaining conden- Cold vapor-atomic absorption spec-
sate. The dried gas sample is fed into trometry (CVAAS) is used to measure
the analyzer. mercury. The single-beam photom- Gold trap Meas. gas cell
eter consists of a low pressure Hg-

Reactor Cooler

Analyzer

Gas
sampling ▸

Photometer
Internal calibration
device
Gold trap

Port for external

calibration device


Bypass
Reaction
▸ Pump
solution Mass flow meter

SiCK MaiHaK | MERCEM 5


System Control and interfaces

integrated data Storage Isolated interfaces, Easy-to-use Software


System automatic range The software is easy to use, entries are
menu-controlled via cursor and func-
ACE 100 is an IBM-compatible compu- Data I/O is done via decoupled fiber-
tion keys. Two operating levels are
ter in a 19” drawer with an illuminated optic interfaces. Analog outputs (0/4-
available: one for measuring and one
LCD and a membrane keypad. A silicon 20 mA), with optional automatic switch-
for servicing. Password protection en-
disk offers mass storage capacity. The over mode for measuring ranges, and
sures optimal operating security.
ACE 100 controls the measurement se- status signals are generated here. It is
quence, calculates measured values, also possible to read in external digital
monitors limit values and provides re- and analog data and process them. Se-
sults, warnings and alarms for the inter- rial interface RS232, RS485 for Mod-
nal display and the de-coupled fiber op- bus communication available.
tic interfaces. The keypad and monitor
are accessed easily behind the trans- ¸ Meets specific demands of industrial measurement
parent front door. An external keyboard systems
can be easily connected if required, for
e.g. servicing purpose. ¸ Easy to use operating menu
¸ fail safe interfaces

display of measured values


and data back-up
All measuring and status data are dis-
played numerically, graphically or as a
concentration curve on the LC display.
Tracing the history of this data is pos-
sible due to the integrated mass sto-
rage disk.

Concentration curve Graphic display

 MERCEM | SiCK MaiHaK


Technical data MERCEM
Hg CEMS
Measuring principle Photometry, cold vapor atomic absorption spectroscopy (CVAAS)
Measuring range Standard: 0 ... 10 µg/dscm (other ranges on request)
Cycle time Approx. 3 minutes
Detection limit Approx. 0.1 μg/dscm
Sample flow rate Approx. 16 LPM sampling system, 0.6 LPM for analyzer
Zero drift ≤ 5% of span or ≤ 1.0 µg/dscm (daily calibration error)
Span drift ≤ 5% of span or ≤ 1.0 µg/dscm (daily calibration error)
Maintenance interval Typically 4 weeks
Temperature influence <5 % of full scale/ ∆T = 35 °K
Auxiliaries required Instrument air: 34 LPM (peak), normal 6 LPM
N2: <1 LPM
SnCI2 solution: consumption: Typically 0.3 L per day, 10 L reservoir in system cabinet
Signal interfaces
Signal outputs ü 4 analog outputs, 0/4 - 20 mA; max. load 500 Ω max
ü 5 digital outputs, freely assignable (max. 250 VAC, 6 A)
ü Serial interface RS232, RS485, Modbus communication
Signal inputs ü 2 analog inputs, 4 - 20 mA
ü 11 digital inputs, freely assig. (bias reducing pot. 11 to 40 AC; low signal input resist. 2.2 k)
Power requirements ü 220 V / 60 Hz (2 phase – no neutral) for analyzer cabinet and for heated sample line
Power consumption ü Cabinet: max. 1900 Watts
ü Heated sampling probe: max 450 Watts
ü Gas sampling filter: max. 450 Watts
ü Heated sample line: 30 Watts/ft
Enclosure
Standard Free-standing general purpose cabinet, sheet steel RAL 7035
Dimensions (H x W x D) 83 x 31.5 x 24 inches (incl. 4 inch base)
Weight 750 lbs
Ambient conditions Temperature: +41 ... 100 °F
Humidity: 80 % max. non-condensing

SICK MAIHAK | Mercem 


A N A LY Z E R S A N D P R O C E S S I N S T R U M E N TAT I O N

at H o M E i n t H E WE OFFER YOU A CHOICE AROUND THE WORLD TO SiCK GRouP


INDUSTRIAL SECTOR YouR SERViCE

We can build on years of experi- SICK MAIHAK offers a number of Where ever you are, our global SICK MAIHAK represents the
ence in the field of Analyzers and sensor-based techniques for anal- network of subsidiaries and rep- process automation segment
Process Instrumentation. That is ysis, ranging from the continuous resentatives is able to supply of the SICK group, one of the
why we are at home in the world gas and dust measurement to qualified support when you need worlds leading manufacturer of
of cement and power plants specialized applications for water it. We deliver the equipment for intelligent sensors and sensor
as well as in the chemical and and liquid analysis. Within the your measuring tasks, provide solutions. With its 4,000 employ-
petrochemical sector. Be it emis- process measurement technol- documentation and training. Our ees, SICK is able to offer an
sion control at waste treatment ogy SICK MAIHAK products play a highly skilled service staff offers extensive portfolio of products
or process optimization for steel central role in determining volume support during installation, com- and services on the market of fac-
manufacturing, SICK MAIHAK flow of gases and level of bulk missioning and maintenance of tory and process automation.
offers tailor-made solutions. materials. the instruments. www.sick.com
8011112/2007-06 · DIV03/BD · Printed in Germany (2007-06) · Subject to change without prior notice
All SICK products are accompanied by standard warranties and other terms and conditions

administrative Center Systems Engineering and integration information@sickmaihak.com


SICK MAIHAK Inc. SICK MAIHAK Inc. www.sickmaihak.com
6900 West 110th Street 15415 International Plaza Drive,
Minneapolis, MN 55438 Suite 100
Phone 952-941-6780 Houston, Texas 77032
Fax 952-941-9287 Phone 281-436-5100
Fax 281-436-5200

Analyzers and Process Instrumentation

You might also like