 Code  Message
   
spc0150 Cannot update database %1. Changes to database are only allowed in procedures.
   
The message indicates that you are trying to assign a value to an attribute outside the context of the
procedure.
 
 
 
   
spc0151 "Default" attribute for element %1 cannot be applied %2. There must be a
conditional element at the same level.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 1/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  This message indicates that there is an error in the Data Provider declaration using
the "Default" clause.

The “Default” attribute works as the Otherwise clause in a Do Case conditional


construction. This message warns you that the group must be preceded by at least
one conditional group with the same name (i.e. there is an Otherwise clause with no
previous Case clauses).

Usually, it means that group names have been written incorrectly.

Examples:

The following is correctly defined:

DP_root
{
Group_1
{
...
}
Group_1 [Default]
{
...
}
}

The following is incorrectly defined:

DP_root
{
Group_1
{
...
}
Group_2 [Default]
{
...
}
}

For more information about the Data Provider Default clause, see Data Provider
language (wiki?5309,Toc%3AData+Provider+language,).
   
spc0152 Cannot find subgroup definition for %1 at row %2

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 2/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  It occurs when the Data Provider has a reference to a "Subgroup" by means of the "Insert" clause, but
the Subgroup is not defined. For more information about the Data Provider Subgroup definition, see
 Data Provider language (wiki?5309,Toc%3AData+Provider+language,)

   
spc0153 Unsupported expression %1 %2
  There appears to be a problem with the Data Provider definition but the specifier cannot detect it. If you
cannot recognize the problem, please send a distribution of the KB, thus enabling the error to be
reproduced for your local support.
   
spc0154 Group with OutputIfDetail attribute should have at least one child group with output
%1.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 3/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  When a Group in a Data Provider has the "OutputIfDetail" clause, there has to be a
nested group with output.

Examples:

The following is correctly defined:

DP_root
{
Group_1 [OutputIfDetail]
{
Group_1_1
{
...
}
}
}

The following is incorrectly defined:

DP_root

Group_1 [OutputIfDetail]
{

...

For more information about the OutputIfDetail clause, see Data Provider language (wiki?
5309,Toc%3AData+Provider+language,)
   
spc0155 Group with Input clause uses non-instantiated attributes %1.
  This message applies to Data Providers. It is triggered when a Group in the Data Provider declaration
uses the "Input" clause and refers to attributes %1 that cannot be instantiated in that level. For more
information about the Input clause, see Data Provider language (wiki?
5309,Toc%3AData+Provider+language,).

   
spc0156 Event %1 for control %2 is not defined.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 4/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  This message indicates that the control %2 needs to be associated with a trigger
event, but the code was not defined in the source.

   
spc0158 Rules %1 not included
  Rule %1 cannot be included in the rule evaluation tree and therefore it will not be
triggered. This mainly happens when the rule has an "input" variable that has not
been initialized. A variable is considered initialized when:

A value is assigned to them by another rule that is executed before.


A value is assigned in the Start Event.
It belongs to the Parm Rule as an input variable.
It is on the Form but it is not read-only.
It appears as an output variable in a Call rule or as returning value in Udp
(Beware, other 'out' variables in UDPs are not considered as output). 
Example 1

Object.Call(&varInput); //The parameter in the called object is an "I


n(put)" parameter.
&varOutput = &varInput;

Both rules will not be included when &VarInput is not initialized.

Example 2 - Business Components

Suppose that a Person Transaction defined as Business Component has the


following rules:

Parm(in:&Mode, in:&PeronId);
PersonId = &PersonId if not &PersonId.IsEmpty();

In this case, the warning is not going to appear in the navigation of Person.
Instead, it will appear in the Person_BC navigation because Business Components
ignore the parm rule and therefore &PersonId is not initialized.

Example 3 - SDT Variables

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 5/23
21/05/2019 Specification Codes from spc0150 onwards | Article

SDT variables are considered initialized not only when the variable itself is assigned
but also when some of their elements are initialized in the same location/Event. For
example:

&Sdt1.Cod = Transaction1Cod on afterinsert;


&Sdt1.Nom = Transaction1Nom on afterinsert;
Procedure1.Call(&Sdt1) on afterinsert;

Note: In previous versions, rules that could not be triggered were shown when
performing a detailed navigation.

   
spc0159 Property 'Initial Value' for %1 cannot reference attributes (%2).
  The error can appear for attributes, variables and SDT elements that reference an
attribute (%2) in their Initial Value property. The property value can be a constant,
expression or UDP function which returns a value of %1's domain. Also, global
variables such as &Today can be included.

   
spc0160 Type mismatch in %1's Initial Value property. Expected type is %2, returned is %3.
  This message indicates that the data type of the expression or value referenced in
the Initial Value property (%3) does not match the attribute's data type (%2). For
example, if the attribute's data type is based on an enumerated domain, the Initial
Value only accepts values from that domain (<Enumerated Domain Name>.<Enum
Value>).

   
spc0161 Line %2. Attribute %1 should not be assigned. It has the Autogenerate property set
to on.
  Notifies that a self-generated attribute is being assigned (its data type is GUID and its
Autogenerate property set to true).
   
spc0162 Object exceeds maximum name length allowed by language (%1 characters).
There are languages that have some restrictions about the length of their program
  name. For instance, RPG and Cobol do not support object names over 10 characters.
In this scenario, GeneXus will warn you at specification time if there is an object that
needs to be generated with those generators and its name length exceeds the limit.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 6/23
21/05/2019 Specification Codes from spc0150 onwards | Article

   
spc0163 Overlaying fields at line %1 column %2 between %3 and %4.
  For text generators (Cobol / RPG), it indicates that there are fields overlayed on the
screen.
   
spc0164 Multiple lines cannot start before column %1.
  For text generators (Cobol / RPG), it indicates that there is more than one line
defined before the specified column.
   
spc0165 Literal or attribute cannot start at Line 1 Column 1.
  For text generators (Cobol / RPG), it indicates that a literal can not start at the
position (1,1) of the screen.
   
spc0166 Window must be within coordinates %1 and %2.
  For text generators (Cobol / RPG), it indicates that the window defined in the form is
greater than the maximum supported by the platform.
   
spc0167 Invalid property values combination. %1 is incompatible with %2.
This message is triggered upon specifying a report whose Call Protocol property has
  HTTP value, and an output (Output_file rule) other than PDF (for example, RTF, TXT)
has been specified. Thus, the object is not generated with that invalid combination
that will cause compilation errors. It only applies to reports, that is, the object
should have at least one printblock.

spc0168 Control/object %1 not found/defined. Are you referencing a form control in a


Business Component?
  This message indicates that control %1 seems to belong to the Form and therefore
does not apply when the Transaction is specified as a Business Component.
Solution: Wrap the rule within a [Win]/[Web] section using the Environment
Attribute (Win, Web, BC, Text).

spc0172 Attribute %1 which is redundant in table %2 will not be updated

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 7/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  It could appear when specifying a Transaction that includes an attribute that is part


of the formula's expression (%2) in another Transaction (%1), which is defined as
redundant in %2. The message warns you that this stored formula is not going to be
automatically updated when the attribute changes its value.

For instance, suppose the canonical Invoice example is simplified as follows: 

Transaction Item

ItemId*
ItemPrice

Transaction Invoice

InvoiceId*
...
{
InvoiceLineId*
ItemId
ItemPrice
ItemLineQty
ItemLineTotal = ItemPrice * ItemLineQty
}
InvoiceTotal = sum(ItemLineTotal) ===> This formula is redundant.

The warning appears when specifying the Item Transaction, because if ItemPrice is
modified, the redundant formula on Invoice that refers to ItemPrice is not. 

   
spc0173 Failed to specify DataProvider %1. %2
  This message indicates that the data provider could not be specified because the
Output property is empty or, in general, when the data provider is malformed.

   
spc0174 Could not find a proper SDT for root element %1
  Indicates that the SDT selected in the Output property is not compatible with the
data provider structure.

   
spc0175 Element %1%2 is collection in %3, but not in %4.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 8/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  The message is triggered when a data provider element is inferred as a collection


but in the SDT indicated as output it is not a collection or vice versa.

   
spc0176 Cannot insert SubGroup ''%1'' at row %2.
  The error appears when you are trying to insert a Subgroup in the data provider, but
for some reason it is impossible.

   
spc0177 Cannot insert SubGroup ''%1'' in SubGroup ''%2'' starting at row %3. Insertion may
loop indefinitely.
  The message is triggered when the specifier detects a loop between subgroup calls
(for example SubGroup1 calls SubGroup2 and Subgroup2 calls SubGroup1)

   
spc0178 Missing member %1 in SDT %2.
  The message appears when a member is referenced in the data provider, but that
member doesn’t exist in the output SDT.

   
spc0179 Attributes not allowed as parms in SubGroup ''%1'' starting at line %2.
  The error appears when an attribute is used as parameter in a subgroup definition
because it’s forbidden. The use of an attribute as argument in a subgroup invocation
is allowed but not as parameter in the subgroup definition.

   
spc0180 'Count' attribute ignored in element starting at row %1
  This message appears when you are using paging in a Data Provider ([count] [skip]),
in a group which isn’t a repetitive one. %1 indicates the row in the Data Provider
where the invalid count appears.

   
spc0181 There is already a %1 with the same name (%2).

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 9/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  This message appears when you create an object whose name matches the name of
an object automatically generated by GeneXus. This could happen in the following
situations:

A Procedure named Proc1 is defined as Main (AProc1 will be generated) and


another object called AProc1 already exists in the KB.
A Transaction named Trn1 is defined as Business Component (Trn1_BC will be
generated), and an object called Trn1_BC already exists in the KB.
The WorkWith for Smart Device Pattern generates programs that do not
appear in the Knowledge Base; all prefixes are
"WorkWithDevices<TransactionName>*", so the warning may be displayed
if you define an object that matches some of these names.
spc0182 Cannot use associated Business Component ('<Transaction Name>')
  When the Work With for Smart Device pattern is applied to a Transaction, some
Sections could be defined based on the table relationship. Each of these sections is
associated with its corresponding Business Component. This warning appears when
the user alters Layouts (edit mode) or Events of a Section, adding attributes that
now imply navigating another table other than the previously associated BC.
As a consequence, some implicit actions are not automatically generated.

   
spc0183 Cannot use attribute and variable with the same name (''%1'').
  In Smart Devices, this message means that there are two fields (a variable and an
attribute) with the same name and this is not supported.
   
spc0185 '%1''s contents will not be preserved between calls to %2.'
  The variable is not being preserved between calls.
Solution: Consider initializing it properly.
   
spc0186 Cannot use variable %1 in form's events
  This message appears when you reference a variable located in a Grid, on a Form
Action (that means, an event outside the grid).

As the variable could have different values for each line of the grid, the actions at the
Form Level does know its value.

   

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 10/23
21/05/2019 Specification Codes from spc0150 onwards | Article

spc0187 Method %1 has no effect


  This message appears when the result of applying the method (%1) is not specified. 

For instance, it has: 

B.Trim()

and the returned value is not assigned to anything.  It must be:

&res = B.Trim()

   
spc0188 Rule %1 for inferred/formula attributes (%2) has no effect.
  This message appears when it is detected that applying the rule (%1) has no effect.
For instance, it has:

Noaccept(A);

But attribute A" is a formula or an inferred attribute.

   
spc0189 Rule %1 has no effect
  The warning indicates that the rule does not have any effect on the program.

For instance, it will be triggered in this kind of rules:

A = "a" on AfterInsert;

Because the assignment is declared a er the Insert, so it has no sense. 

Or in the following rule when "A" is an inferred attribute:

Default(A,1);

Note: In versions prior to GeneXus X Evolution 2 Upgrade 3, the message description


was: "Assignment rule %1 has no effect".

   

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 11/23
21/05/2019 Specification Codes from spc0150 onwards | Article

spc0190 Rule %1 has no effect


  This warning appears when it is detected that applying the rule (%1) has no effect.

For instance, it has:

Default(A,1);

But "A" is an inferred attribute.

Note: As from GeneXus X Evolution 2 Upgrade 3 this warning is shown as spc0189.

spc0191 Synchronize event for attributes %1 matches a previously defined synchronize event
(%2).
  Indicates that the referenced OfflineDatabase object has a synchronize user event
on a list of attributes that determine a table for which another synchronize event
already exists in this same object.
   
spc0192 Synchronize event for %1 is not referenced by the application.
  Indicates that the referenced OfflineDatabase object has a synchronize user event
on a list of attributes that determine a table that is not among the tables stored
offline.
   
spc0193 Attributes %1 need to be assigned in synchronize event for %2.
  Indicates that the referenced OfflineDatabase object has a synchronize user event
that attempts to allocate some attributes by code but not all those required by that
event.
   
spc0194 Cannot assign attributes %1 in synchronize event for %2.
  Indicates that the referenced OfflineDatabase object has a synchronize user event
that attempts to assign an attribute that is not in the table that synchronizes that
event.
   
spc0195 Unsupported expression %1. Ignored

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 12/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  The message indicates that GeneXus will not generate code for expression %1. 

For instance, this could happen when :

an array variable is assigned to another one.


an array variable is initialized in this way: &var = <exp>  instead of:  &var() =
<exp> .
See How to Define Variables and Arrays (wiki?
7385,How+to+Define+Variables+and+Arrays,) for more details.

This message appears as from GeneXus X Evolution 2 Upgrade 3. In previous


GeneXus versions, the problem also exists but no warning is displayed.

   
spc0196 Synchronize event for attributes %1 may generate duplicate records.
  Indicates that the referenced OfflineDatabase object has a synchronize event that
can attempt to insert duplicate records (the event navigation can not, in this case,
ensure uniqueness in the records).
   
spc0197 %1 should be exposed as a REST protocol Web Service.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 13/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  The message indicates that %1 needs to be defined as REST Web Service (wiki?


14573,Category%3AREST+Web+Services,) in order to be invoked.

This could happen in the followings scenarios:

Smart Device Online Object that refers a BC code inside a User Event.


Smart Device Online Object that calls a Procedure or Data Provider inside a
User Event.
Whenever you call a Procedure, Data Provider or BC from a User Event in Online SD
apps, this invocation will be generated as a REST Web Service call. So the called
objects have to be defined as Rest services (wiki?
28213,Toc%3ARest+web+services+in+GeneXus,).

For instance, suppose we have this user event on Smart Device app Layout: 

Event "Insert"
Composite
&Customer.CustomerName = "Peter"
&Customer.Save()
EndComposite
Endevent

Where &Customer is a variable defined as Customer Data Type (and Customer


Transaction is Defined as Business Component).

If the Customer Transaction is not exposed as REST web service, the warning will
appear; otherwise, the program could know how to handle this invocation.

   
spc0198 DataSelector %1 (directly or indirectly) references itself.
  This warning appears when it is detected that a DataSelector references itself
directly or indirectly.

This could happen in the following scenarios

If the property "DataSelector" of the DataSelector %1 references itself.


If the chain of references ends with DataSelector %1 iteself.
   
spc0199 Procedure cannot be exposed as Client Side Script (%1)
https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 14/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  Occurs when the object has set the Expose as Client Side Script property but it can
not be generated in this way because it uses some function that requires access to
the DBMS or uses some function not implemented for the generator associated with
the object.
   
spc0200 External Object %1 does not implement method '%2(' for %3 environment. (%4
'%5')
  Example : error: spc0200: External Object Notifications does not implement method
'opensession(' for Java Web environment. (Procedure
'WorkflowSDSendNotification')

This error applies when a method — %2 — from an External object (wiki?


5669,Category%3AExternal+object,) — %1 — is used by a GeneXus Object (wiki?
1866,Category%3AGeneXus+objects,) — %5 — and the method is not implmented
for the environment — %3 — you are generating.

There is a particular case when developing Smart Devices applications, where some
methods can only be called from client events (wiki?24332,Client-
side+Events+in+Smart+Devices,) . E.g.: NetworkAPI (wiki?
22526,NetworkAPI+external+object+%28X+Evolution+3%29,).IsServerAvailable()

   
spc0201 The value of ''%1'' does not take into account changes to the value of %2
  This applies in the following scenario:

An inline formula inside a For each references a variable that is modified in the same
For each.

At execution time, the value of the variable remains constant in the calculation of
the formula.

This problem occurs because the formula and the variable are calculated in the
same select sentence of the For each, to improve performance.

This message appears as from GeneXus X Evolution 2 Upgrade 4. In previous


GeneXus versions, the problem also exists, but no warning is displayed.

   
https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 15/23
21/05/2019 Specification Codes from spc0150 onwards | Article

spc0202 %1 ''%2'' cannot be called, it is %3 to module ''%4''.


  Example 1: error: spc0202: Web Panel 'List_Clients' cannot be called, it is private to
module 'B'.

Example 2: error: spc0202: Table 'Company' cannot be accessed, it is private to


module 'A'.

The error is triggered, at specification time, when an object in a given Module,


references another object in a different Module, and it is not allowed to. Usually, to
remove the error you should check if you are calling the right object. If it is the right
one, change the value of its Object Visibility property (wiki?
22473,Object+Visibility+property,). If not, change the reference.

Message added in GeneXus Tilo Beta 1 (wiki?22217,GeneXus+Tilo+Beta+1,)

   
spc0203 'New, update or delete to local database will not be sent to the server%1. Consider
using Business Components instead.'
  This warning appears when the procedure performs updates to the offline database
(wiki?22237,Offline+Smart+Devices+applications,) using new, delete or assignments
in for each commands.

It indicates that these changes made to the offline database in this procedure will
not be sent to the server and suggests using business components instead.

   
spc0204 ''Enabled'' property assignment over attribute %1%2 conflicts with ''%3'' rule.'
  This message is displayed when a transaction has a NoAccept rule and the Enabled
property of the attribute that is not accepted is assigned. This conflict may cause a
forbidden 403 error in a web application at runtime if the control is enabled through
code and the NoAccept rule is also applied.

   
spc0205 Option DISTINCT not supported with Unique clause%1.
  It occurs when in a group (eg: For each) the Unique clause is indicated and also the
Option Distinct clause is present.
   
spc0206 Cannot reference attribute(s) %1 unless they are referenced in Unique clause%2.
https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 16/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  It occurs when in a group (eg: For each) the Unique clause is indicated and within
the For each body are named attributes that are not found in the extended tables of
the attributes indicated as unique. The solution is either to remove the mentioned
attributes from the For each body or to add them to the list of unique.
   
spc0207 Formula %1 referenced in Unique clause cannot be evaluated in server%2.
  It occurs when in a group (eg: For each) the Unique clause is indicated by
referencing a formula attribute that can not be evaluated in the server.
   
spc0208 'warning: spc0208: No triggered actions '%1''
  This warning is displayed when an object has a list of actions (rules or formulas)
which cannot be generated because one of its dependencies never becomes
instantiated (known in the context of the object).

spc0209 'error: spc0209: Table '%1' cannot be accessed.'


  This error is displayed when an object is accessing any of the attributes of a
transaction' table, and only if the following conditions are met:

The transaction' Object Visibility property (wiki?


22473,Object+Visibility+property,) is set to Private —  or all parallel
transactions` Object Visibility property (wiki?
22473,Object+Visibility+property,) is set to Private.
The object accesing the attributes belongs to another Module object (wiki?
22414,Toc%3AModules,) — in case of defining parallel transactions the error
will be displayed when the object accesing the attributes does not belong to
the same Module object (wiki?22414,Toc%3AModules,) of any of the parallel
transactions.
spc0210 'warning: spc0210: '%1' not supported, using '%2' function instead.
  This warning is displayed when the functions ServerNow(), ServerDate() or
ServerTime() are used in a Smart Devices object with the Connectivity Support
property offline.

'ServerNow()' not supported, using 'Now()' function instead.


'ServerDate()' not supported, using 'Date()' function instead.
'ServerTime()' not supported, using 'Time()' function instead.
   
spc0211 Unique clause in break group not supported%1.
https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 17/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  It occurs when the Unique clause is used in a break.


   
spc0212 Cannot update readonly %1 %2%3. 
  This error is displayed when the developer tries to update a table whose associated
transaction is set as Read Only (Update Policy property (wiki?
29599,Update+Policy+property,) = Read Only).

%1 = Table (if the developer is trying to update in a Procedure object (wiki?
6293,Category%3AProcedure+object,) using a For Each (wiki?
24744,For+Each+command,) or New (wiki?6714,New+command,) command) or
Business Component.

   
spc0213 Attribute %1 is a non redundant formula. It cannot be updated.
  Occurs when trying to update a non-redundant formula inside a For each.
   
spc0214 Attribute(s) %1 should be %2 to navigate table %3%4.
  Indicates that you have a Dynamic Transactions that receives parameters (wiki?
36732,Dynamic+Transactions+that+allow+receive+parameters,) and there are
missing parameters to be able to navigate that table.
   
spc0215 'Subtype groups %1 identify the same base table (attributes %2). Consider merging
them.'
  This warning is displayed If two or more subtypes groups have the same primary key
(i.e. base table). In this case, the groups should be defined as one group. More
information: SAC 38242 (http://www2.gxtechnical.com/portal/hgxpp001.aspx?
15,4,61,O,S,0,,38242)
spc0216 Break not allowed in group starting at line %1 (web panel %2)

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 18/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  As since GeneXus 15, this error is displayed when in the web panel %2 there is a grid
and also an event with a for each that navigates the same base table of the grid.

Example:

A web panel has a grid with attribute "Att", and the following event

Event 'Test'

for each 

where Att =&Att

msg('test')

endfor

Endevent

In order to avoid this error, and in case you need this for each for some reason ,
move the for each code to a subroutine. But if you want to just read these attributes
mentioned in the for each, the for each is not necessary. Just use the attributes.

spc0217 Object is unreachable


  This warning is displayed when no main object is in the callers tree of that object. It
applies to Procedures and SD Objects. For objects with this warning, neither code
nor metadata is generated.
   
spc0218 Control %1 has an empty value that conflicts with its Empty Item property
  This warning is displayed when a ComboBox/ListBox Control type variable is based
on a domain including the empty value, and the control enables the Empty Item
property.
   
spc0219 %1 property value %2 not allowed.
  It occurs when specifying a web object in a KB that does not have a defined web
theme. In this case, it is indicated 'Theme property value (none) not allowed.' To
solve it, choose a web theme in the properties of the version.
   
https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 19/23
21/05/2019 Specification Codes from spc0150 onwards | Article

spc0220 Cannot call %1.%2) from %3s.


  This happens if you try to call a global event from a non-web event (% 1 is the object
type,% 2 is the method, and% 3 indicates the type of the calling object).
   
spc0221 Event ''%1'' must be defined for updatable %2.
  It occurs when specifying a Dynamic Transaction that allows update data (wiki?
28656,Dynamic+Transactions+that+allow+update+data,), but to which the insert /
update / delete events were not defined. To solve it, you have to define the events.
   
spc0222 %1%2 currently not supported.
  It is a generic error indicating that something (described in% 1% 2) is not currently
supported.
   
spc0223 Updatable %1%2 will be read-only for %3 environment.
  This warning indicates that the mentioned Dynamic Transaction (wiki?
28062,Toc%3ADynamic+Transactions,) will be considered as read-only in the
mentioned environment. It occurs in offline smart devices environments when a
Transaction object (wiki?1908,Category%3ATransaction+object,) / Business
Component (wiki?5846,Toc%3ABusiness+Component,) has set its Used to property
(wiki?29584,Used+to+property,) = Retrieve Data and also has defined the Insert /
Update / Delete events.
   
spc224 Module %1 not available for %2 environment. 

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 20/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  This error message is displayed when the GeneXus Module version installed on the
KB being used doesn't match the GeneXus Module version provided by the GeneXus
version being run.

When GeneXus is run a er installing a new version, and the opened KB was created
with a previous version, the Build operation updates the GeneXus Module (and the
following warning is displayed in the output: Updating 'GeneXus' module version
from X.X.X.XXXXX to required Y.Y.Y.YYYY.).
 
So, just building an object is usually enough to fix the problem. If not, selecting
Knowledge Manager / Manage Module References opens a dialog box showing the
GeneXus Module version that the KB has installed and the GeneXus Module new
version to manually update it.
 
Advanced notes:
The binary files are located in the directory %appdata%\GeneXus\GeneXus\
<GXVersion>\Modules_v1.0\GeneXus_4f454e73-7d8f-4a0f-908a-
1a355f3634a5\<ModuleVersion>\Platforms\<PlatformName>.
A module has N implementations. It is possible to have only the
implementation for a CSharp environment. In the GeneXus module, we
have it for each one of the environments supported: Java, CSharp,
Android and iOS.
If you only have the directory %appdata%\GeneXus\GeneXus\
<GXVersion>\Modules_v1.0\GeneXus_4f454e73-7d8f-4a0f-908a-
1a355f3634a5\<ModuleVersion> and inside it only the .opc file, you need to
check the version of the module referenced in the KB.
Workaround: open the dialog box "Manage Module References" and
update the version in the KB.
If you don't have some of the directories highlighted in the path
 %appdata%\GeneXus\GeneXus\
<GXVersion>\Modules_v1.0\GeneXus_4f454e73-7d8f-4a0f-908a-
1a355f3634a5\<ModuleVersion>.
Workaround: run "genexus /install"; doing so creates that path and
copies the .opc in the GeneXus installation directory.
spc0225 Cannot navigate table %1 unless attribute(s) %2 are referenced in Unique clause%3.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 21/23
21/05/2019 Specification Codes from spc0150 onwards | Article

  This error occurs when a navigation with the Unique clause performs a join that
must be resolved in the client (that is, the statement is split into at least 2
statements) and some of the "source" attributes of the join is not present in the list
of attributes of the Unique clause.
   
spc0226 Cannot navigate to multiple Data Stores in control %1.
  Indicates that the navigation of a control (Dynamic Combo Box (wiki?
7598,Dynamic+Combo+Box,) or edit with the InputType property (wiki?
8799,InputType+property,) = 'Descriptions') goes over more than one Data Store. For
the case of a Dynamic Combo Box, it can be solved by creating a Data Provider that
returns the required data and by setting the combo Data Source From property
(wiki?22945,Data+Source+From+property,) = 'Data Provider'.
   
spc0227 Property ''%1'' for table %2 should be set to perform synchronization by timestamp
%3.
  It occurs when specifying an Offline Database which their Logically Deleted Attribute
(wiki?37091,Logically+Deleted+Attribute+property,) / Last Modified Date Time
Attribute (wiki?37092,Last+Modified+Date+Time+Attribute+property,) properties are
not set, so that timestamp synchronization can be applied to the indicated table.
   
spc0228 Ambiguous command Load in ''%1'', use grid.load() method instead.
  This error is displayed when a Web Panel (wiki?
6916,Category%3AWeb+Panel+object,) includes more than one grid and the Load
command is used inside a user event. Instead of using the Load command you have
to use the GridName.Load() method to point out the grid you want to load.
   
spc0229 %1 must belong to table %2 in order to be used in %3 property.
  This error indicates that when specifying the timestamp synchronization of a table
in an OfflineDatabase it was detected that the  Logically Deleted Attribute property
(wiki?37091,Logically+Deleted+Attribute+property,) / Last Modified Date Time
Attribute property (wiki?37092,Last+Modified+Date+Time+Attribute+property,)
points to an attribute that is not in the associated table (for example, found in the
extended). The IDE filter this but a er a normalization may be an invalid value.
   
spc1001 'Empty' is not a valid value for property 'Control Name' in <control>.
  It's an error message. As since GeneXus 15, the control names cannot be empty.

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 22/23
21/05/2019 Specification Codes from spc0150 onwards | Article

Was this page helpful?


(wiki?26969,,)
Your feedback about this content is important. Let us know what you think.
Sure! No

Backlinks
See all
Specification Error Codes and Messages (wiki?5933,Specification+Error+Codes+and+Messages,)
Specification Codes from spc0100 to spc0... (wiki?
6433,Specification+Codes+from+spc0100+to+spc0149,)
No triggered actions (wiki?17062,No+triggered+actions,)
Forward links
See all
GeneXus objects (wiki?1866,GeneXus+objects,)
Transaction object (wiki?1908,Transaction+object,)
Data Provider language (wiki?5309,Data+Provider+language,)
More from mshuster
See all
Allow Selection property (wiki?8680,Allow+Selection+property,)
Allow Hovering property (wiki?43237,Allow+Hovering+property,)
Multiple Base Transactions in a For Each... (wiki?
24456,Multiple+Base+Transactions+in+a+For+Each+command,)

BY MAZZILLI

— CREATED: 10 APRIL 2008 09:43 AM - LAST UPDATE: 25 APRIL 2019 03:03 PM BY MSHUSTER

https://wiki.genexus.com/commwiki/servlet/wiki?6774,Specification+Codes+from+spc0150+onwards 23/23

You might also like