Revision : 2.0
Date : 7/10/2003
Number of pages: 218
File Name: System codes.doc
Event classification
The following chapters show the different levels of possible events. The tables contain a
code (preliminary, may be changed) and a possible text for the message on the display for
each level. The event code “00” indicates that no inhibit or special drive status is active.
Notifications
Notifications indicate events without influence on the truck operation, some should be
reported to the service personnel for corrective action.
Note: Battery buffered data might be lost, if the battery will not be replaced in time.
Note: All functions relying on commands coming from the serial link are not available.
Warnings
Warnings indicate events without immediate influence on truck operation, but service is
required soon. Component failures will cause a warning, if there’s no immediate effect
on truck operation. As the failure may influence the truck operation, if it is present for a
longer time, service is required as soon as possible
The inverter resumes operation after 2 s automatically, if no failure is present any more.
The field regulator and the inverter resume operation after 10...15 s automatically, if no
failure is present any more.
111-Severe drive component failure, After reset Limp mode possible (C2) 6F hex
115-Inverter and exciter operation not possible any more (C5) 73 hex
Ground fault
Sequences
202
202-GTO Module preheating active (Seq) CA hex
203
203-Precharging active (Seq) CB hex
205
205-Start-up sequence running (Seq) CD hex
206
206-Transition“standby idle” running(Seq) CE
hex
207
207-IPM extinction sequence running (Seq) CF
hex
208
208-Transition to “drive shutdown” running
(Seq) D0 hex
209
209-Power-down sequence running (Seq) D1 hex
Fault finding
Introduction
Digital potentiometer
The digital potentiometer on module G011 has to be set to "7". Any other setting is not
allowed for normal service without explicit permission from SIEMENS.
The digital potentiometer on module G035 is not used on this project. The setting is not
relevant.
Exchange of TCU modules and components
If it is necessary to replace any of the TCU modules the following rules have to be
observed:
### Modules may be withdrawn or inserted only when they are de-energized, i.e.
the control unit must be switched off and the front plug connector of the relevant module
must be removed.
### Modules with adjustable hardware elements ("variant modules", e.g. with
resistors), must be replaced by identically adjusted modules. If the new module is ordered
with the complete ordering designation the adjustable elements are correctly set.
TCU module settings
All variable complements and settings on the modules of the TCU are specified in the
corresponding TCU hardware adjustment instructions.
Resistors: All resistors are of type E0207 (0.28W, 85°C), tolerance 0.1%, unless
otherwise specified.
Fault finding
Most of the analog signals used by the traction control unit can be measured via a
transient recorder
(6FH 9388). For this purpose the transient recorder, must be installed in slots G003 &
G043. The analog signals are now decoupled and available on front connector X3 for
measuring purposes.
The M bus bar on the terminal strip is employed as the measuring reference point for
external signals. For internal signals (e.g. TTL level) the common M strip conductor is
employed as a reference point, e.g. the M socket, or the pins b2 / b32 at the back plane
plug connector of the corresponding module. In the case of the MC modules (modules
with direct connection to the computer bus via the bus module) only the input and the
output signals (which are all decoupled) may be measured in addition to the signals at the
measuring sockets provided for this purpose.
Internal signals, which are not decoupled, may not be measured on account of the
danger of interference.
The generally applicable ESD rules should be observed for all measurements (refer
to Hardware documentation).
A frequently cause of drive faults are faults of the measured values. The following table
shows which TCU cards evaluate which measured values and the corresponding signal
names in the TCU software.
voltages:
speed values:
temperatures:
Diagnosis
The SIBAS32 diagnosis system stores all events, which are important for the evaluation
of the TCU process data. Therefore not every stored event means that a fault or a wrong
process status occurred.
Some events are only stored for commissioning or additional maintenance information.
The reasons for faults which restrict or prevent the traction system from fully operation
are mostly to be found outside of the TCU. Most of the time, by simply replacing the
appropriate TCU printed circuit board it is possible to locate, if the fault is within the
TCU or outside.
The diagnosis system stores always the current process data for every event
The following subsections show a list of all possible events stored in the diagnosis
memory and a description for each of these codes:
Description
Software detection by processor card (slot) [processing time slice]
Hardware detection by card performing the hardware supervision
Protection reactions:
Inverter GTO pulse inhibit
Excitation
Main circuit breaker
Drive shutdown
Possible reasons list of possible causes for the event
Action to reset procedure to reset the protection reactions and/or the
cause of the fault; the event and the fault reaction may
occur again after the reset
Protection functions:
“soft inhibit” ramp down torque request to zero with a slope of 8333 Nm/s
before stopping the inverter GTO-pulses
“medium ramp down torque request to zero within one second from
inhibit” maximum torque, before stopping the inverter GTO-pulses
Immediate inhibit inverter GTO-pulses without any torque ramp down
inhibit
inhibit main circuit breaker : opening of the main circuit breaker by control
signal
TCU versions:
The following list shows all events, used by the SIBAS32 diagnosis system. They are
listed with the event code and a the long name. Codes which are not listed are not used on
AC HAUL TRUCK.
70 DSPA: OVERCURRENT
71 DSPA: PARAMETER FAULT BRAKING CHOPPER FREQUENCY
72 DSPA: FAILURE VOLTAGE TRANSDUCER U13 (T101)
73 DSPA: FAILURE VOLTAGE TRANSDUCER U23 (T102)
74 DSPA: HSCX DATA FROM DSP B MISSING
76 DSPA: SUM OF OUTPUT CURRENTS NOT ZERO
77 DSPA: FAILURE V/F-CARD FOR DSP A (L055)
78 DSPA: PULSE-PATTERN FAULT AT HIGH FREQUENCY
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT Siemens Energy and Automation, Inc. All Rights Reserved. Pages 26 of 218
TRACTION DRIVES / SE&A
79 DSPA: ACTIVE CURRENT CONTROLLER IN LIMITATION
80 DSPA: ACTIVE CURRENT REFERENCE VALUE IN LIMITATION
81 DSPA: BRAKING CHOPPER CONTROLLER IN LIMITATION
82 DSPA: PULSE-INHIBIT BY DSP A (G019)
85 DSPA: UNBALANCE PROTECTION INVERTER CURRENTS
event code and diagnosis message 13 SYS: HARDWARE FAULT POWER START-UP
UNIT ONLINE
Description A hardware fault of the power start-up unit (G163) is
detected during normal TCU operation.
Software detection by CPU (G011) [T6]
Protection reactions: propel inhibit
Propel inhibit override possible with dump body override switch
Possible reasons hardware fault of the power start-up unit (G163)
action to reset • override propel inhibit by pressing the dump body
override switch
• switch off / switch on – sequence TCU
action to repair replace defective power start-up unit (G163)
SIEMENS-event code
Notes
event code and diagnosis message 14 SYS: TCU POWER SUPPLY FAILURE 24V
FOR PULSE AMPLIFIER
Description
Software detection by CPU (G011) [T6]
Protection reactions: propel inhibit
Propel inhibit
Possible reasons
action to reset
action to repair
SIEMENS-event code
Notes
event code and diagnosis message 30 SYS: TCU POWER SUPPLY FAILURE 5 V
event code and diagnosis message 31 SYS: TCU POWER SUPPLY FAILURE -15 V
event code and diagnosis message 32 SYS: TCU POWER SUPPLY FAILURE +15 V
event code and diagnosis message 33 SYS: TCU POWER SUPPLY FAILURE +24 V
event code and diagnosis message 34 SYS: TCU POWER SUPPLY FAILURE -24 V
event code and diagnosis message 35 SYS: TCU POWER SUPPLY FAILURE
PRIMARY
Description Under voltage supervision primary TCU power supply.
Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • power supply short circuit
• battery under voltage
action to reset switch off / switch on – sequence TCU
action to repair • eliminate short-circuit
• charge battery
SIEMENS-event code no (as CPU process stops)
Notes
event code and diagnosis message 51 DSPA: START-UP FAILURE DSP A (G019)
Description Over current at the output of inverter A (phase L1, L2, L3)
Threshold 2499 A
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
Possible reasons • power circuit fault inverter A (e.g. short circuit)
• fault of inverter output current measuring device
action to reset Automatic reset of pulse-inhibit after 2 s, if over current
disappeared.
action to repair • repair power circuit inverter A
• repair/exchange faulty measuring device
SIEMENS-event code 81
Notes
event code and diagnosis message 74 DSPA: HSCX DATA FROM DSP B MISSING
event code and diagnosis message 76 DSPA: SUM OF OUTPUT CURRENTS NOT
ZERO
Description The sum of the inverter phase currents exceeded the
allowed maximum.
Threshold 500 A
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
Possible reasons • power circuit fault inverter A
• fault of measuring device for inverter output currents
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair • repair power circuit inverter A
• repair/exchange faulty measuring device
SIEMENS-event code
Notes
event code and diagnosis message 77 DSPA: FAILURE V/F-CARD FOR DSP A
(L055)
Description Offset or amplification of a V/f-channel is out of the
admissible range.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit A and B
Possible reasons • failure V/f-card L055
• failure DSP-card G019
action to reset Automatic reset of inverter pulse inhibit, if offsets and
amplifications are in the permissible range for all channels
at the next calibration. The calibration will be performed
every 60 seconds.
action to repair • exchange V/f-card L055
• exchange DSP-card G019
Notes
100+
event code and diagnosis message 100 DSPB: FAILURE DSP B (G027)
event code and diagnosis message 101 DSPB: START-UP FAILURE DSP B (G027)
event code and diagnosis message 102 DSPB: BUSY-MONITORING DSP B (G027)
event code and diagnosis message 103 DSPB: SOFTWARE-TRACO DSP B (G027)
HAS TRIGGERED
Description Message for the commissioning personnel, event does not
indicate a failure.
Software detection by DSP B (G019) / CPU (G011)
Notes
event code and diagnosis message 104 DSPB: SOFTWARE-TRACO DSP B (G019)
FULL
Description All partitions of the DSP software transient recorder are
occupied. Message for the commissioning personnel,
event does not indicate a failure.
Software detection by DSP B (G019) / CPU (G011)
Notes
event code and diagnosis message 106 DSPB: INITIALIZATION FAULT DSP B
(G027)
Description Start-up check routines of DSP-software detected a fault.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • inhibit inverter A and B in propel
• inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons failure DSP-card B (G027)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair replace defective DSP-card (G027)
SIEMENS-event code 111
Notes
event code and diagnosis message 107 DSPB: TIME-SLICE OVERFLOW DSP B T1
108 DSPB: TIME-SLICE OVERFLOW DSP B T2
109 DSPB: TIME-SLICE OVERFLOW DSP B T3
110 DSPB: TIME-SLICE OVERFLOW DSP B T4
Description The processing of one time slice of the DSP-software did
not terminate within the allowed time.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons • processing time overload
• fault of DSP-card B (G027)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair • software correction (by SIEMENS)
• exchange DSP-card B (G027)
SIEMENS-event code 111
Notes
Description Over current at the output of inverter B (phase L1, L2, L3)
Threshold 2499 A
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • power circuit fault inverter B (e.g. short circuit)
• fault of inverter output current measuring device
action to reset Automatic reset of pulse-inhibit after 2 s, if over current
disappeared.
action to repair • repair power circuit inverter B
• repair/exchange faulty measuring device
SIEMENS-event code 81
Notes
event code and diagnosis message 121 DSPB: PARAMETER FAULT BRAKING
CHOPPER FREQUENCY
Description Braking chopper frequency is out of possible range.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons • fault of DSP B (G027)
• fault of CPU (G011)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair • exchange DSP B (G027)
• exchange CPU (G011)
SIEMENS-event code 111
Notes If the chopper frequency is set correctly in the software,
the fault should not occur. If the event shows up in the
memory nevertheless, it indicates a fault of the DSP- or
CPU-card.
event code and diagnosis message 122 DSPB: FAILURE VOLTAGE TRANSDUCER
U13 (T201)
Description Failure acquisition of motor transducer value U13
(transducer T201).
Software detection by DSP B (G027)
Protection reactions: Switchover to current modeling for flux.
Possible reasons fault of motor voltage measuring device
action to repair repair/exchange faulty motor voltage measuring device
SIEMENS-event code 41
Notes
event code and diagnosis message 123 DSPA: FAILURE VOLTAGE TRANSDUCER
U23 (T202)
Description Failure acquisition of motor transducer value U23
(transducer T202).
Software detection by DSP B (G027)
Protection reactions: Switchover to current modeling for flux.
Possible reasons Fault of motor voltage measuring device
action to repair Repair/exchange faulty motor voltage measuring device
SIEMENS-event code 41
Notes
event code and diagnosis message 124 DSPB: HSCX DATA FROM DSP B MISSING
event code and diagnosis message 126 DSPB: SUM OF OUTPUT CURRENTS NOT
ZERO
Description The sum of the inverter phase currents exceeded the
allowed maximum.
Threshold 500 A
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • power circuit fault inverter B
• fault of measuring device for inverter output currents
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair • repair power circuit inverter B
• repair/exchange faulty measuring device
SIEMENS-event code
Notes
event code and diagnosis message 127 DSPB: FAILURE V/F-CARD FOR DSP B
(L063)
Description Offset or amplification of a V/f-channel is out of the
admissible range.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • failure V/f-card L063
• failure DSP-card G027
action to reset Automatic reset of inverter pulse inhibit, if offsets and
amplifications are in the permissible range for all channels
at the next calibration. The calibration will be performed
every 60 seconds.
action to repair • exchange V/f-card L063
• exchange DSP-card G027
Notes
event code and diagnosis message 128 DSPB: PULSE-PATTERN FAULT AT HIGH
FREQUENCY
Description
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons
action to reset
action to repair
SIEMENS-event code
Notes
event code and diagnosis message 129 DSPB: ACTIVE CURRENT CONTROLLER IN
LIMITATION
Description The slip frequency reference is at the stability limit for
more than 2 seconds.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons High torque request at low bus-voltage.
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes
event code and diagnosis message 130 DSPB: ACTIVE CURRENT REFERENCE
VALUE IN LIMITATION
Description The active current component reference is at the limit
(determined by the admissible total current) for more than
2 seconds.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons High torque request at low bus-voltage.
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes
event code and diagnosis message 131 DSPB: BRAKING CHOPPER CONTROLLER
IN LIMITATION
Description
Software detection by DSP B (G027)
Protection reactions:
Possible reasons
action to reset
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes
350+
event code and diagnosis message 350 IO: OVERVOLTAGE DC-LINK, 1. LEVEL
(PIN X2.F2)
Description Over voltage DC-link (transducer U105)
Threshold 3000 / 2900 V (hysteresis)
Hardware detection by IO-card (G035), comparator 1
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit A and B for 2 s
Possible reasons • bus voltage regulation disturbance
• fault of bus voltage measuring device
action to repair repair faulty measuring device
SIEMENS-event code 81
Notes
event code and diagnosis message 351 IO: OVERVOLTAGE DC-LINK, 2. LEVEL
(PIN X2.D2)
Description Over voltage DC-link (transducer U105)
Threshold 3400 / 500 V (hysteresis)
Hardware detection by IO-card (G035), comparator 2
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • secondary fault (e.g. in case of chopper failure)
• fault of bus voltage measuring device
action to reset reset by driver at standstill
action to repair • eliminate original fault
• repair faulty measuring device
SIEMENS-event code
event code and diagnosis message 353 IO: OVERCURRENT BRAKING CHOPPER
A(PIN X2.D4)
354 IO: OVERCURRENT BRAKING CHOPPER
B(PIN X2.F6)
Description chopper over current (transducer U104 or U204)
Threshold 2000 A
Hardware detection by IO-card (G035), comparator 4 (A), comparator 5 (B)
Protection reactions: No
Possible reasons • short circuit
• grid resistor fault
• fault of chopper current measuring device
action to repair • eliminate short circuit
• repair grid resistor fault
• repair faulty measuring device
SIEMENS-event code 112,113
Notes
event code and diagnosis message 355 IO: OVERCURRENT DC-LINK (PIN
X2.D6)
Description
Threshold
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 356 IO: OVERVOLTAGE TROLLEY (PIN
X2.F08)
Description
Threshold
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 358 IO: OVERCURRENT TROLLEY (PIN
X2.B8)
Description
Threshold
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 360 IO: TEST-VOLTAGE IO-CARD NOT ZERO
Description The voltage source for the comparator test is not zero in
normal operation.
Threshold 0V
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 367 IO: PROCESS SUPERVISION CPU (G011)
381 IO: PROCESS SUPERVISION DSP A
(G019)
382 IO: PROCESS SUPERVISION DSP B
(G027
Description The process clocks of processor cards are supervised by
watchdog timers.
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • process clock failure CPU (367)
• process clock failure DSP A (381)
• process clock failure DSP B (382)
action to reset switch off / switch on – sequence TCU
action to repair • exchange CPU-card (G011)
• exchange DSP A (G019)
• exchange DSP B (G027)
SIEMENS-event code
Notes
event code and diagnosis message 372 IO: INCORRECT VERSION FPGA IO
(G035)
Description The revision level of the IO-card FPGA is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong IO-card FPGA in use
action to repair exchange IO-card FPGA or IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 373 IO: INCORRECT APPLICATION VERSION
FPGA IO
Description The application version of the IO-card FPGA is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong IO-card FPGA in use
action to repair exchange IO-card FPGA or IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 375 IO: FAILURE ADC IO (G035)
event code and diagnosis message 376 IO: INCORRECT VERSION IO-CARD
(G035)
Description The version of the IO-card is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong IO-card in use
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes
event code and diagnosis message 397 IO: HARDWARE COMPARATOR FAULT
event code and diagnosis message 398 IO: FAILURE ADC IO FOR TCU
TEMPERATURE (G035)
Description The conversion time for the IO-temperature AD-converter
was exceeded.
Software detection by CPU (G011) [T8]
Protection reactions: No
Possible reasons AD-converter failure IO-temperature
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
Notes
event code and diagnosis message 399 IO: TCU TEMPERATURE OUT OF
MEANINGFUL RANGE
Description The TCU temperature or its gradient are out of reasonable
ranges.
Software detection by CPU (G011) [T8]
Protection reactions: No
Possible reasons PCB fault IO-card (035)
action to reset switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
Notes
603+
event code and diagnosis message 603 TCU POWER SUPPLY FAILURE 24 V FOR
PULSE AMPLIFIER
Description Under voltage power supply for pulse amplifiers and IPM
electronic card has been detected
Hardware detection by power-start-up unit (G163) / UWS-card A (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • DC/DC-converter failure C045
• failure power start-up unit (G163)
• failure pulse amplifier card (2B: L111, L119; 2A:
L095, L103)
• failure IPM electronic card (external from TCU)
• short-circuit (especially wiring for the 24V-supply of
the IPM electronic card)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter C045
• replace defective power start-up unit (G163)
• replace defective pulse amplifier card (2B: L111, L119;
2A: L095, L103)
• replace defective IPM electronic card (external from
TCU)
• repair defective wiring
SIEMENS-event code
Notes
event code and diagnosis message 645 UWSA: OVERVOLTAGE DC-LINK (GW5)
event code and diagnosis message 646 UWSA: SUPERVISION BUS-CLOCK UWSA
event code and diagnosis message 647 UWSA: SUPERVISION PCB-CLOCK UWS A
(G071)
Description PCB-clock failure UWS-card A (G071).
Hardware detection by UWS-card (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons PCB-clock failure UWS-card A
action to reset switch off / switch on – sequence TCU
action to repair exchange UWS-card A (G071)
SIEMENS-event code
Notes
event code and diagnosis message 660 UWSA: INCORRECT VERSION FPGA UWSA
(G071)
Description The revision level of the UWS-card FPGA is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong UWS-card FPGA in use
action to repair exchange UWS-card FPGA or UWS-card (G071)
SIEMENS-event code
Notes
event code and diagnosis message 663 UWSA: FAILURE MICROCONTROLLER UWS
A (G071)
Description The micro controller of the UWS-card is not ready for
operation.
Hardware/software detection by CPU (G011) [T1]
Protection reactions: No
Possible reasons Micro controller failure.
action to reset Switch off / switch on – sequence TCU
action to repair Exchange UWS-card A (G071)
SIEMENS-event code 41
Notes
event code and diagnosis message 664 UWSA: PEAK CURRENT PROTECTION
INVERTER ACTIVE
Description One of the inverter output currents exceeded the
permissible level.
Threshold 1900...2300 A / 1000...1600 A (hysteresis, depending on
stator frequency)
Hardware detection by UWS A (G071)
Protection reactions: • affected GTO will be switched off
• immediate torque reduction to 80% of actual level for 3
seconds
Possible reasons • control disturbances caused by road conditions
• power circuit fault (e.g. motor internal fault)
• fault of inverter current measuring device
action to repair • repair power circuit fault
• exchange faulty measuring device
SIEMENS-event code
Notes Sporadic events are admissible and do not require
corrective action.
event code and diagnosis message 665 UWSA: FAILURE ADC UWS A (G071)
event code and diagnosis message 666 UWSA: PARAMETER OR HARDWARE FAULT
UWS A (G071)
Description Faulty UWS-card or fault of software parameter for UWS-
functions.
Software detection by CPU (G011) [T8]
Protection reactions:
Inverter GTO pulse inhibit Permanent inhibit inverter A
Possible reasons • faulty UWS-card (G071)
• software parameter fault
action to reset • limp mode for propel is possible after fault reset by
driver at standstill (limp mode for retard is enabled
automatically)
• switch off / switch on - sequence TCU
action to repair • exchange UWS-card A (G071)
• correct software parameter fault (only SIEMENS)
SIEMENS-event code 111
Notes
event code and diagnosis message 667 UWSA: PEAK CURRENT PROT. DURING
INVERTER-START-PHASE
Description A peak current protection (code 664) occurs during the
start-phase of the inverter.
Software detection by CPU (G011) [T2]
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
• permanent inhibit inverter A (BRAM)
Possible reasons Power circuit fault (e.g. short circuit)
action to reset Limp mode for propel is possible after fault reset by driver
at standstill
action to repair Repair power circuit fault
SIEMENS-event code 111
Notes
event code and diagnosis message 668 UWSA: PEAK VOLTAGE PROTECTION DC-
LINK ACTIVE
Description
Software detection by CPU (G011) [T2]
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
Possible reasons Power circuit fault (e.g. short circuit)
action to reset
action to repair Repair power circuit fault
SIEMENS-event code
Notes
event code and diagnosis message 669 UWSA: PEAK CURRENT COUNTER
PROTECTION INVERTER
Description The number of peak current protections within a time
frame exceeded the permissible limit.
Software detection by CPU (G011) [T1]
Threshold 6 peak current protections within 192 ms
Protection reactions:
Inverter GTO pulse inhibit Immediate inhibit inverter A and B
Possible reasons See code 664
action to reset Limp mode is possible after fault reset by driver at
standstill
action to repair See code 664
SIEMENS-event code 111
Notes
event code and diagnosis message 697 UWSA: HARDWARE COMPARATOR FAULT
703+
event code and diagnosis message 703 UWSB: IPM CURRENT DETECTION (PIN
X1.D12)
Description
Hardware detection by UWS-card B (G079)
Protection reactions:
Inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation Inhibit by hardware circuit (totallock)
Main circuit breaker Inhibit by hardware circuit (totallock)
Possible reasons • fault of IPM-firing electronic card
• fault of pulse amplifier card B (2B: L119, 2A: L103)
• fault of UWS-card B (G079)
action to reset Automatic reset of fault reactions as soon as IPM feedback
signal goes low.
action to repair • exchange BOD, if firing was unjustified
• exchange IPM-firing electronic card
• exchange faulty pulse amplifier card (2B: L119, 2A:
L103)
• exchange faulty UWS-card B (G079)
SIEMENS-event code
Notes
event code and diagnosis message 715 UWSB: IPM FEEDBACK SIGNAL
event code and diagnosis message 745 UWSB: OVERVOLTAGE DC-LINK (GW5)
event code and diagnosis message 746 UWSB: SUPERVISION BUS-CLOCK UWSB
event code and diagnosis message 747 UWSB: SUPERVISION PCB-CLOCK UWS B
(G079)
description PCB-clock failure UWS-card B (G079).
hardware detection by UWS-card (G079)
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
excitation Inhibit by hardware circuit (totallock)
main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons PCB-clock failure UWS-card B
action to reset Switch off / switch on – sequence TCU
action to repair Exchange UWS-card B (G079)
SIEMENS-event code
notes
event code and diagnosis message 760 UWSB: INCORRECT VERSION FPGA UWSB
(G079)
description The revision level of the UWS-card FPGA is incorrect.
software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong UWS-card FPGA in use
action to repair Exchange UWS-card FPGA or UWS-card (G079)
SIEMENS-event code
notes
event code and diagnosis message 763 UWSB: FAILURE MICROCONTROLLER UWS
B (G079)
description The micro controller of the UWS-card is not ready for
operation.
hardware/software detection by CPU (G011) [T1]
protection reactions: No
possible reasons Micro controller failure.
action to reset Switch off / switch on - sequence TCU
action to repair Exchange UWS-card B (G079)
SIEMENS-event code 41
notes
event code and diagnosis message 764 UWSA: PEAK CURRENT PROTECTION
INVERTER ACTIVE
description One of the inverter output currents exceeded the
permissible level.
threshold 1900...2300 A / 1000...1600 A (hysteresis, depending on
stator frequency)
hardware detection by UWS B (G079)
protection reactions: • affected GTO will be switched off
• immediate torque reduction to 80% of actual level for 3
seconds
possible reasons • control disturbances caused by road conditions
• power circuit fault (e.g. motor internal fault)
• fault of inverter current measuring device
action to repair • repair power circuit fault
• exchange faulty measuring device
SIEMENS-event code
notes Sporadic events are admissible and do not require
corrective action.
event code and diagnosis message 765 UWSB: FAILURE ADC UWS B (G079)
event code and diagnosis message 766 UWSB: PARAMETER OR HARDWARE FAULT
UWS B (G079)
description Faulty UWS-card or fault of software parameter for UWS-
functions.
software detection by CPU (G011) [T8]
protection reactions:
inverter GTO pulse inhibit Permanent inhibit inverter B
possible reasons • faulty UWS-card (G079)
• software parameter fault
action to reset • limp mode for propel is possible after fault reset by
driver at standstill (limp mode for retard is enabled
automatically)
• switch off / switch on - sequence TCU
action to repair • exchange UWS-card B (G079)
• correct software parameter fault (only SIEMENS)
SIEMENS-event code 111
notes
event code and diagnosis message 767 UWSB: PEAK CURRENT PROT. DURING
INVERTER-START-PHASE
description A peak current protection (code 764) occurs during the
start-phase of the inverter.
software detection by CPU (G011) [T2]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B (BRAM)
possible reasons Power circuit fault (e.g. short circuit)
action to reset Limp mode for propel is possible after fault reset by driver
at standstill
action to repair Repair power circuit fault
SIEMENS-event code 111
notes
event code and diagnosis message 768 UWSB: PEAK VOLTAGE PRTECTION DC-
LINK ACTIVE
description
software detection by CPU (G011) [T2]
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B in propel
possible reasons Power circuit fault (e.g. short circuit)
action to reset
action to repair Repair power circuit fault
SIEMENS-event code
notes
Event code and diagnosis message 769 UWSB: PEAK CURRENT COUNTER
PROTECTION INVERTER
description The number of peak current protections within a time
frame exceeded the permissible limit.
software detection by CPU (G011) [T1]
threshold 6 peak current protections within 192 ms
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B
possible reasons See code 764
action to reset Limp mode is possible after fault reset by driver at
standstill
action to repair See code 764
SIEMENS-event code 111
notes
event code and diagnosis message 797 UWSB: HARDWARE COMPARATOR FAULT
800+
event code and diagnosis message 800 BUS2: SERIAL INTERFACE DATA
RECEPTION FAILURE
description The TCU did not receive a valid serial interface telegram
for more than 1 s.
software detection by CPU (G011) [T6]
protection reactions: The cruise control will be switched off, if the cruise
control commands are transmitted via serial interface.
possible reasons • fault/failure of transmitting device
• fault of serial interface card (G063)
• fault of serial interface wiring
action to reset Switch off / switch on – sequence control power
action to repair • repair or exchange transmitting device
• exchange serial interface card (G063)
• repair serial interface wiring
SIEMENS-event code 23
notes
event code and diagnosis message 819 BUS2: SERIAL INTERFACE CARD
FAILURE (G063)
description Fault/failure of serial interface card (G063)
software detection by CPU (G011) [T6]
protection reactions: The cruise control will be switched off, if the cruise
control commands are transmitted via serial interface.
possible reasons • fault/failure of serial interface card (G063)
action to reset Switch off / switch on – sequence TCU
action to repair • exchange serial interface card (G063)
SIEMENS-event code No transmission of event code possible any more.
notes
event code and diagnosis message 850 TR: TRACO 1 HAS TRIGGERED
event code and diagnosis message 852 TR: TRACO 2 HAS TRIGGERED
event code and diagnosis message 871 ETM: OPEN CIRCUIT PT100 ETM1
(L131)
description The TCU performs two plausibility checks for
temperatures read by the ETM-card. The value and its
gradient must be in reasonable ranges, otherwise an open
circuit is suspected.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • failure PT100
• fault of PT100 wiring
• fault of ETM-card 1 (L131)
action to repair • exchange PT100
• repair PT100 wiring
• exchange ETM-card 1 (L131)
SIEMENS-event code 41
notes If the TCU detects an open circuit, the last valid temperature
value will be frozen. If a valid temperature value was not yet
read, the temperature will be set to a default value (0°C).
event code and diagnosis message 872 ETM: OPEN CIRCUIT PT100 ETM2
(L139)
description The TCU performs two plausibility checks for
temperatures read by the ETM-card. The value and its
gradient must be in reasonable ranges, otherwise an open
circuit is suspected.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • failure PT100
• fault of PT100 wiring
• fault of ETM-card 2 (L139)
action to repair • exchange PT100
• repair PT100 wiring
• exchange ETM-card 2 (L139)
SIEMENS-event code 41
notes If the TCU detects an open circuit, the last valid temperature
value will be frozen. It a valid temperature value was not yet
read, the temperature will be set to a default value (0°C).
event code and diagnosis message 873 ETM: OPEN CIRCUIT PT100 ETM3
(L147)
description The TCU performs two plausibility checks for
temperatures read by the ETM-card. The value and its
gradient must be in reasonable ranges, otherwise an open
circuit is suspected.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • failure PT100
• fault of PT100 wiring
• fault of ETM-card 3 (L147)
action to repair • exchange PT100
• repair PT100 wiring
• exchange ETM-card 3 (L147)
SIEMENS-event code 41
notes If the TCU detects an open circuit, the last valid temperature
value will be frozen. It a valid temperature value was not yet
read, the temperature will be set to a default value (0°C).
event code and diagnosis message 876 ETM: FAILURE ADC IO (G035) FOR
TEMPERATURES OF ETM 1
description The conversion time for the AD-converter reading
temperatures from ETM1 was exceeded.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
notes
event code and diagnosis message 877 ETM: FAILURE ADC IO (G035) FOR
TEMPERATURES OF ETM 2
description The conversion time for the AD-converter reading
temperatures from ETM2 was exceeded.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
notes
event code and diagnosis message 878 ETM: FAILURE ADC IO (G035) FOR
TEMPERATURES OF ETM 3
description The conversion time for the AD-converter reading
temperatures from ETM3 was exceeded.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
notes
910+
Event code and diagnosis message 921 DEFECTIVE OUTPUT TRANSISTOR ABIN 1
(C003)
Description The output transistor for the field regulator enable
command on card C003 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on - sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 1 (2B: C003)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !
Event code and diagnosis message 923 DEFECTIVE OUTPUT TRANSISTOR ABIN 3
(C019)
Description The output transistor for the field regulator enable
command on card C019 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on - sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 3 (2B: C019)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !
Event code and diagnosis message 924 DEFECTIVE OUTPUT TRANSISTOR ABIN 4
(C027)
Description The output transistor for the field regulator enable
command on card C019 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on - sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 4 (2B: C027)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !
Event code and diagnosis message 925 DEFECTIVE OUTPUT TRANSISTOR ABIN 5
(C035)
Description The output transistor for the field regulator enable
command on card C035 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on – sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 5 (2B: C035)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !
event code and diagnosis message 970 AIF: FAILURE ADC AIF (G087)
1299+
event code and diagnosis message 1299 START-UP TEST: FEEDBACK ERROR
CONTACTOR K105
description The contactor K105 (module preheat contactor) is
commanded during the start-up test. If the feedbacks from
the contactor do not indicate that the contactor closed
during the test, code 1299 will be stored in the diagnosis
memory.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • fault of contactor K105
• fault of contactor wiring
action to repair • exchange contactor K105
• repair contactor wiring
SIEMENS-event code 41
notes If the contactor K105 does not work, module preheating is
impossible.
event code and diagnosis message 1311 HL: POWER-SUPPLY FAILURE GATE UNIT
event code and diagnosis message 1315 HL: FAILURE IPM CURRENT DETECTION
event code and diagnosis message 1330 HL: GTO-PULSE-TEST: TEST STOPPED
1423+
event code and diagnosis message 1423 IUW: OUTPUT CURRENT SUPERVISION
(IDLE) INV A
description The absolute value of one inverter output current exceeds
the threshold after the inverter is out of operation for more
than 5 s.
threshold 100 A
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit Permanent inhibit inverter A (BRAM-buffered)
possible reasons Fault of inverter current measuring device
action to reset Limp mode for propel is possible after fault reset by driver
at standstill (limp mode for retard is enabled
automatically)
action to repair Exchange or repair faulty measuring device
SIEMENS-event code 111
notes
event code and diagnosis message 1424 IUW: OUTPUT CURRENT SUPERVISION
(IDLE) INV B
description The absolute value of one inverter output current exceeds
the threshold, while the inverter is not operating since at
least 5 s.
threshold 100 A
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit Permanent inhibit inverter B (BRAM-buffered)
possible reasons Fault of inverter current measuring device
action to reset Limp mode for propel is possible after fault reset by driver
at standstill (limp mode for retard is enabled
automatically)
action to repair Exchange or repair faulty measuring device
SIEMENS-event code 111
notes
event code and diagnosis message 1450 IUW: PRECHARGING SUPERVISION DC-
LINK VOLTAGE 1
description The DC bus voltage is less than the threshold, although the
field regulator is enabled for at least 360 ms.
threshold 50 V
software detection by CPU (G011) [T4]
protection reactions:
excitation Inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of control wiring (field regulator)
• fault of DC bus voltage measuring device
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair control wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes
event code and diagnosis message 1451 IUW: PRECHARGING SUPERVISION DC-
LINK VOLTAGE 2
description The DC bus voltage is less than the threshold, although the
alternator output control is enabled for at least 6 s.
threshold 500 V
software detection by CPU (G011) [T4]
protection reactions:
excitation Inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes
event code and diagnosis message 1456 IUW: TORQUE REDUCTION DUE TO
TROLLEY CONDITIONS
description During the DBT mode, if the trolley line voltage is
between 800V to 1000V not more than 10s, the torque is
reduced from 100% to 80% linearly. During the DT mode,
if the trolley line voltage is between 1800V to 2200V, the
torque need to be reduced from 100% to 75% linearly. If
the torque reduction keeps more than 5s.
threshold
software detection by CPU (G011) [T4]
protection reactions:
excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes
event code and diagnosis message 1457 IUW: TORQUE REDUCTION DUE TO DC-
LINK VOLTAGE
description
threshold
software detection by CPU (G011) [T4]
protection reactions:
excitation inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes
event code and diagnosis message 1458 DC-LINK VOLTAGE OUT OF ENVELOPE IN
PROPEL
description The DC bus voltage is out of the admissible range in
propel.
threshold 800/850 V (hysteresis for lower limit)
2875/2925 V (hysteresis for upper limit)
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B in propel
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)t
• fault of bus voltage measuring device (transducer
U105)
action to reset Automatic reset of inverter inhibit as soon as bus voltage
is back in the admissible range.
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code 81
notes
event code and diagnosis message 1459 DC-LINK VOLTAGE OUT OF ENVELOPE IN
RETARD
description The DC bus voltage is out of the admissible range in
retard.
threshold 800/850 V (hysteresis for lower limit)
3000/3050 V (hysteresis for upper limit)
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B in retard
possible reasons • alternator fault
• rectifier fault
• grid fault (grid open)
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)t
• fault of bus voltage measuring device (transducer
U105)
action to reset Automatic reset of inverter inhibit as soon as bus voltage
is back in the admissible range.
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair grids
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code 81
notes
description The difference between the bus voltage set point and the
measured bus voltage is more than the threshold. For 1 s
threshold 300 V
software detection by CPU (G011) [T1]
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B
excitation Inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of bus voltage measuring device (transducer
U105)
action to reset The TCU will try to charge-up the bus after some seconds
automatically. If the fault is still present the precharging
supervision (codes 1450 or 1451 will trigger).
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code 82
notes
event code and diagnosis message 1461 IUW: TROLLEY LINE UNDERVOLTAGE
SUPERVISION
description During the DBT mode, if the trolley line voltage is less
than 800VDC in DBT or 1500VDC in DT for more than
500ms
threshold
software detection by CPU (G011) [T1]
protection reactions: The DISENGAGE SEQUENCE will be implemented
possible reasons • power cabling fault (alternator/rectifier/DC-link)
• fault of bus voltage measuring device (transducer
U105)
• trolley line problems
• pantograph problems
action to reset Automatic reset after trolley disconnect sequence
successful.
action to repair • exchange or repair faulty measuring device
• check pantograph pressure
SIEMENS-event code
notes
event code and diagnosis message 1463 IUW: TROLLEY LINE OVERVOLTAGE
SUPERVISION
description During the DBT mode if the trolley line voltage is greater
than 1850VDC or in DT above 2650Vfor 500ms.
threshold
software detection by CPU (G011) [T1]
protection reactions: The DISENGAGE SEQUENCE will be implemented.
event code and diagnosis message 1470 IUW: GROUND FAULT DETECTED
1) Activate the “drive shutdown” switch or select the mode using User-commands
Reset the inhibit by the reset-button or in User-commands . Watch bus-voltage and
ground voltage, check the diagnosis memory. If the bus-voltage comes up again, the
ratio of ground and bus voltage is correct and the ground fault detection does not
occur again, the ground fault is not on the alternator/rectifier side of the DC-link
contactor K104. If the ground fault detection occurs again, the fault must be on the
alternator/rectifier side.
2) If the ground fault is not on the alternator/rectifier side of K104, turn off the “drive
shutdown” switch. Watch the bus-voltage and the ground voltage and check the
diagnosis memory. If the bus-voltage comes up again, the ratio of ground and bus
voltage is correct and the ground fault does not occur again as long as the inverter
are not operating (truck at standstill, shift lever in “NEUTRAL”), the ground fault
must be on the inverter output side (e.g. motors).
3) Evaluate the filtered values for ground voltage and bus voltage stored in the
diagnosis memory for the ground fault detection:
• ground voltage = 0 V indicates a ground fault on the positive DC-bus
• ground voltage = bus voltage indicates a ground fault on the negative DC-bus
• ground voltage = ½ bus voltage indicates a ground fault on the alternator/rectifier
side or on the inverter/motor side
The I2-t supervision of the DC-link current prevents the alternator from sustained
overloading. The “I2-integral” is calculated as shown in the functional block diagram:
IDC
I2-integral
+1
sign
IDCN 100 % -1
T = 98 s
The “I2-integral” is supervised and resulting in the “alternator over current warning”
(Code 1517) and the “alternator over current protection” (Code 1518).
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT Siemens Energy and Automation, Inc. All Rights Reserved. Pages 139 of 218
TRACTION DRIVES / SE&A
examples:
1511+
event code and diagnosis message 1511 IUW: TROLLEY LINE AND DC-LINK
CURRENT SUPERVISION UNDER TROLLEY
MODE
description During trolley mode, if the difference between trolley line
current and dc link current is greater than 200A for 3s
threshold 200A
software detection by CPU (G011)
protection reactions: The DISENGAGE SEQUENCE will be implemented.
possible reasons Faulty measuring devices
Faulty power cabling
SIEMENS-event code
notes
event code and diagnosis message 1513 TORQUE REDUCTION DUE TO THE I
SQUARE TIME
description - The “I²-integral” (Maximum Inverter peak current)
exceeds the protection-limit.
threshold 100%/95%
software detection by CPU (G011)
protection reactions: Reduce both inverter torque to 80%
possible reasons Inverter overload operation
SIEMENS-event code 42
notes
event code and diagnosis message 1514 TORQUE REDUCTION DUE TO THE TORQUE
SQUARE TIME
description - The “T²-integral” (Maximum Inverter torque) exceeds
the protection-limit.
threshold NO
software detection by CPU (G011)
protection reactions: Reduce both inverter torque to 80%
possible reasons Inverter overload operation
SIEMENS-event code 42
notes
event code and diagnosis message 1520 TMP: INVERTER MODULE TEMPERATURE A
< OPERATION LIMIT
description The minimum module temperature of inverter A is less
than the operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit inhibit inverter A and B
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibit as soon as module
temperature is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.
event code and diagnosis message 1521 TMP: INVERTER MODULE TEMPERATURE A
> APRS-LIMIT
description The maximum module temperature of inverter A is higher
than the limit for the automatic power reduction system
(APRS).
threshold 64/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor A from 100% to 75% of
requested value between 64° and 67°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes The APRS-system can be disabled by the customer per
menu.
event code and diagnosis message 1522 TMP: INVERTER MODULE TEMPERATURE A
> SHUTDOWN-LIMIT
description The maximum module temperature of inverter A is higher
than the shutdown-limit.
threshold 67/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter A in retard
possible reasons insufficient power module cooling
action to reset • limp mode for propel is possible after a fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1525 TMP: SNUBBER RESISTOR TEMPERATURE
A > WARNING-LIMIT
description The Snubber resistor temperature is higher than the
threshold for a warning.
threshold 90/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons Insufficient Snubber resistor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes
event code and diagnosis message 1526 TMP: SNUBBER RESISTOR TEMPERATURE
A > SHUTDOWN-LIMIT
description The temperature of Snubber resistor A is higher then the
shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit • “medium inhibit” inverter A and B in propel
• “medium inhibit” inverter A in retard
possible reasons Insufficient Snubber resistor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1530 TMP: INVERTER MODULE TEMPERATURE B
< OPERATION LIMIT
description The minimum module temperature of inverter B is less
than the operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit inhibit inverter A and B
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibit as soon as module
temperature is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.
event code and diagnosis message 1531 TMP: INVERTER MODULE TEMPERATURE B
> APRS-LIMIT
description The maximum module temperature of inverter B is higher
than the limit for the automatic power reduction system
(APRS).
threshold 69/67 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor B from 100% to 75% of
requested value between 69° and 72°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1532 TMP: INVERTER MODULE TEMPERATURE B
> SHUTDOWN-LIMIT
description The maximum module temperature of inverter B is higher
than the shutdown-limit.
threshold 72/67 °C
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter B in retard
possible reasons Insufficient power module cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1535 TMP: SNUBBER RESISTOR TEMPERATURE
B > WARNING-LIMIT
description The Snubber resistor temperature is higher than the
threshold for a warning.
threshold 90/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons Insufficient Snubber resistor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes
event code and diagnosis message 1536 TMP: SNUBBER RESISTOR TEMPERATURE
B > SHUTDOWN-LIMIT
description The temperature of Snubber resistor B is higher then the
shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit • “medium inhibit” inverter A and B in propel
• “medium inhibit” inverter B in retard
possible reasons Insufficient Snubber resistor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1537 TMP: SNUBBER A/B DELTA T >
SHUTDOWN-LIMIT
description The difference value of maximum temperature of Snubber
resistors and ambient temperature is higher then the
shutdown-limit.
threshold 40/35 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit “medium inhibit” inverter A and B in propel
possible reasons Insufficient Snubber resistor cooling
action to reset automatic reset of inverter inhibit as soon as temperature is
lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code
notes
1620+
event code and diagnosis message 1620 TMP: CHOPPER MODULE TEMPERATURE A
< OPERATION LIMIT
description The chopper module temperature A is less than the
operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit Inhibit inverter A and B
self load-test inhibit Test-test inhibit
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibits as soon as temperature
is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.
event code and diagnosis message 1621 TMP: CHOPPER MODULE TEMPERATURE A
> APRS-LIMIT
description The chopper module temperature A is higher than the limit
for the automatic power reduction system (APRS).
threshold 64/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard torque reduction motor A and B from 100%
to 75% of requested value between 64° and 72°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1622 TMP: CHOPPER MODULE TEMPERATURE A
> SHUTDOWN-LIMIT
description The chopper module temperature A is higher than the
shutdown-limit.
threshold 67/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation Inhibit excitation as soon as
• inverters are blocked and SHTS-system is active in
retard
• truck is at standstill and SHTS-system is active in
propel
test-test inhibit Test-test inhibit
possible reasons Insufficient power module cooling
action to reset Automatic reset of inhibits as soon as chopper temperature
is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 107, 114
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1627 TMP: GRID BLOWER SUPERVISION
description The event code will be stored if the chopper duty cycle is
higher than 10% and the feedback from the grid blower is
not “OK” for more than 5 s.
software detection by CPU (G011) [T7]
protection reactions: No
possible reasons
action to repair
SIEMENS-event code 43
notes Right now the grid blower feedback is always “LOW”
(14.4.99); threshold for chopper duty cycle has to be
adjusted once a feedback (e.g. from a pressure switch) is
installed
event code and diagnosis message 1628 TMP: RETARD GRID TEMPERATURE A >
APRS-LIMIT
description The retard grid temperature A is higher than the limit for
the automatic power reduction system (APRS).
threshold 270/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard power reduction motor A and B from 100%
to 75% of maximum value between 220° and 240°C
possible reasons Insufficient grid cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1629 TMP: RETARD GRID TEMPERATURE A >
SHUTDOWN-LIMIT
description The retard grid temperature A is higher than the shutdown-
limit.
threshold 300/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
test-test inhibit Test-test inhibit
possible reasons Insufficient grid cooling
action to reset Automatic reset of inhibits as soon as grid temperature is
lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 66, 107, 114, 115
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1630 TMP: CHOPPER MODULE TEMPERATURE B
< OPERATION LIMIT
description The chopper module temperature B is less than the
operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit Inhibit inverter A and B
test-test inhibit Test-test inhibit
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibits as soon as temperature
is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.
event code and diagnosis message 1631 TMP: CHOPPER MODULE TEMPERATURE B
> APRS-LIMIT
description The chopper module temperature B is higher than the limit
for the automatic power reduction system (APRS).
threshold 69/67 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard torque reduction motor A and B from 100%
to 75% of requested value between 69° and 67°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1632 TMP: CHOPPER MODULE TEMPERATURE B
> SHUTDOWN-LIMIT
description The chopper module temperature B is higher than the
shutdown-limit.
threshold 72/67 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation Inhibit excitation as soon as
• inverters are blocked and SHTS-system is active in
retard
• truck is at standstill and SHTS-system is active in
propel
test-test inhibit Test-test inhibit
possible reasons Insufficient power module cooling
action to reset Automatic reset of inhibits as soon as chopper temperature
is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 107, 114
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1638 TMP: RETARD GRID TEMPERATURE B >
APRS-LIMIT
description The retard grid temperature B is higher than the limit for
the automatic power reduction system (APRS).
threshold 270/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard power reduction motor A and B from 100%
to 75% of maximum value between 220° and 240°C
possible reasons Insufficient grid cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1639 TMP: RETARD GRID TEMPERATURE B >
SHUTDOWN-LIMIT
description The retard grid temperature B is higher than the shutdown-
limit.
threshold 300/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
test-test inhibit Test-test inhibit
possible reasons Insufficient grid cooling
action to reset Automatic reset of inhibits as soon as grid temperature is
lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 66, 107, 114, 115
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.
event code and diagnosis message 1645 TMP: ALTERNATOR STATOR TEMPERATURE
> APRS-LIMIT
description The chopper module temperature B is higher than the limit
for the automatic power reduction system (APRS).
threshold 140/130 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear propel power reduction motor A and B from 100%
to 75% of maximum between 160° and 180°C
possible reasons Insufficient alternator cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1646 TMP: ALTERNATOR STATOR TEMPERATURE
> SHUTDOWN-LIMIT
description The alternator stator temperature is higher than the
shutdown-limit.
threshold 160/130 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation Inhibit excitation as soon as truck is at standstill and
SHTS-system is active in propel
test-test inhibit Test-test inhibit
possible reasons Insufficient alternator cooling
action to reset Automatic reset of inhibits as soon as alternator
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 65, 115
notes The automatic shutdown-system can be disabled by the
customer.
event code and diagnosis message 1650 TMP: TRACTION MOTOR TEMPERATURE A
> APRS-LIMIT
description The traction motor temperature A is higher than the limit
for the automatic power reduction system (APRS).
threshold 180/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor A and B from 100% to 75%
of requested value between 220° and 240°C
possible reasons Insufficient motor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1651 TMP: TRACTION MOTOR TEMPERATURE B
> APRS-LIMIT
description The traction motor temperature B is higher than the limit
for the automatic power reduction system (APRS).
threshold 180/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor A and B from 100% to 75%
of requested value between 220° and 240°C
possible reasons Insufficient motor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.
event code and diagnosis message 1653 TMP: TRACTION MOTOR TEMPERATURE A
> SHUTDOWN-LIMIT
description The traction motor temperature is higher than the
shutdown-limit.
threshold 200/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter A in retard
possible reasons Insufficient motor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibits as soon as motor
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer.
event code and diagnosis message 1654 TMP: TRACTION MOTOR TEMPERATURE B
> SHUTDOWN-LIMIT
description The traction motor temperature is higher than the
shutdown-limit.
threshold 200/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter B in retard
possible reasons Insufficient motor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibits as soon as motor
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer.
event code and diagnosis message 1660 TMP: TRACTION MOTOR BEARING
TEMPERATURE A > WARNING-LIMIT
description The traction motor bearing temperature is higher than the
APRS-limit.
threshold 95/85 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: Operator is informed of over temperature
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.
event code and diagnosis message 1661 TMP: TRACTION MOTOR BEARING
TEMPERATURE B > WARNING-LIMIT
description The traction motor bearing temperature is higher than the
APRS-limit.
threshold 95/85 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: Operator is informed of over temperature
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.
event code and diagnosis message 1663 TMP: TRACTION MOTOR BEARING
TEMPERATURE A > SHUTDOWN-LIMIT
description The traction motor bearing temperature is higher than the
Shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T7]
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.
event code and diagnosis message 1664 TMP: TRACTION MOTOR BEARING
TEMPERATURE B > SHUTDOWN-LIMIT
description The traction motor bearing temperature is higher than the
Shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T7]
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.
1729+
event code and diagnosis message 1729 TMP: MAIN BLOWER SUPERVISION
description The event code will be stored if the blower inverter set
point frequency is higher than 60 Hz for 120Hz blower or
25HZ for 60Hz blower and the feedback from the main
blower is not “OK” for more than 60 s.
software detection by CPU (G011) [T7]
protection reactions: Inhibit the propel if the fault last longer that 1 minute
possible reasons
action to repair
SIEMENS-event code 44
notes This fault can be masked by user parameter
event code and diagnosis message 1763 TEMPERATURE TCU > WARNING-LIMIT
event code and diagnosis message 1764 TEMPERATURE TCU > SHUTDOWN-LIMIT
event code and diagnosis message 1765 OVERTEMPERATURE TCU: REQUEST TCU-
SHUTDOWN
description The TCU temperature is higher than the shutdown limit.
threshold
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation
drive shutdown transition to “drive shutdown”
possible reasons • TCU blower failure (code 17)
• insufficient cooling air supply (e.g. from dirt on the
vent holes at the bottom of the TCU)
• fault of TCU temperature sensor IO-card (G035)
action to reset Inverter and excitation inhibit will last until the TCU is
switched off. Operation can be resumed after power-up of
the TCU and if the TCU-temperature is O.K.
action to repair • repair or exchange TCU blower subassembly
• ensure proper cooling air supply
• exchange IO-card (G035)
SIEMENS-event code
notes
description The absolute motor speed value A is less than 0,1 1/s,
while the absolute motor speed value B is greater than 40
1/s. To set the speed sensor failure, this condition must be
true for at least 240 ms.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
possible reasons Fault/failure of speed measuring equipment.
action to reset • limp mode for propel is possible after reset by driver at
standstill, if only one speed sensor failed
• automatic reset of inverter inhibit if “tolerance band
condition” is fulfilled (e.g. in limp mode) and the “set
condition” for the speed sensor failure is not active
• reset of speed sensor failure by driver’s reset at
standstill, if both speed sensors (A and B) failed
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes speed sensor “tolerance band condition”:
• the quotient of the absolute motor speed values is
between 0.7 and 1.3
• the minimum of the absolute motor speed values is
higher than 3 1/s
The “tolerance band condition” is fulfilled if both conditions are
true for more than 2 s
description The absolute motor speed value B is less than 0,1 1/s,
while the absolute motor speed value A is greater than 40
1/s. To set the speed sensor failure, this condition must be
true for at least 240 ms.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
possible reasons Fault/failure of speed measuring equipment.
action to reset • limp mode for propel is possible after reset by driver at
standstill, if only one speed sensor failed
• automatic reset of inverter inhibit if “tolerance band
condition” is fulfilled (e.g. in limp mode) and the “set
condition” for the speed sensor failure is not active
• reset of speed sensor failure by driver’s reset at
standstill, if both speed sensors (A and B) failed
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes speed sensor “tolerance band condition”:
• the quotient of the absolute motor speed values is
between 0.7 and 1.3
• the minimum of the absolute motor speed values is
higher than 3 1/s
The “tolerance band condition” is fulfilled if both conditions are
true for more than 2 s
event code and diagnosis message 1788 SUPERVISION MOTOR SPEED A DSP
event code and diagnosis message 1789 SUPERVISION MOTOR SPEED B DSP
event code and diagnosis message 1790 SUPERVISION ENGINE SPEED DSP
1815+
event code and diagnosis message 1816 MINIMUM VEHICLE SPEED SUPERVISION
FOR TROLLEY
description Under trolley mode, if the vehicle speed is less than set
minimum speed limit
threshold Adjustable
software detection by CPU (G011) [T6]
protection reactions: The ENGAGE SEQUENCE is not possible or the
DISENGAGE SEQUENCE will be implemented.
SIEMENS-event code
notes
1963+
event code and diagnosis message 1963 SHIFT LEVER VALIDATION FAILURE
description The message will be stored if the feedbacks from the shift
lever (forward, reverse, neutral) do not clearly indicate the
shift lever position for more than 1.2 s.
software detection by CPU (G011) [T6]
protection reactions: The last valid shift lever position will not be changed, as
long as the truck moves; once the truck reaches standstill,
the shift lever position will be regarded as “neutral” until a
different position is clearly indicated. With the shift lever
position “neutral” no propel torque is possible.
possible reasons • shift lever fault
• shift lever wiring fault
• fault of binary input converter card (2B: G127, 2A:
G135)
action to repair • repair/exchange shift lever
• repair shift lever wiring
• exchange binary input converter card (2B: G127, 2A:
G135)
SIEMENS-event code 68
notes
2009+
event code and diagnosis message 2009 SIV: EXCITAION CURRENT SETPOINT
SUPERVISION
description The excitation current set point is at its upper limit for
more than 10 s.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation as soon as inverters are out of operation
possible reasons Disturbance of bus voltage control by faulty measured
values or faulty field regulator.
action to reset Reset by driver at standstill.
action to repair • check and repair bus voltage measuring equipment
(transducer U105)
• repair/exchange field regulator
SIEMENS-event code
notes
event code and diagnosis message 2029 SIV: MAIN BLOWER CONTACTOR
SUPERVISION
description The message will be stored, if the feedback signals from
the main blower contactors K141, K142 and K143 do not
reflect the status requested from the TCU for more than 2
s.
software detection by CPU (G011) [T6]
protection reactions: If the blower inverter is not yet connected to the power
supply (commands for K141 and K143 “LOW”), the
sequence to connect it to the power supply won’t start.
If the blower inverter is already connected to the power
supply, it will be disconnected from the power supply if
the 2.4 tap connection is active.
As the blower is not able to work without the inverter
connected, the drive system will be without cooling and
secondary faults may occur.
possible reasons • fault of contactors or auxiliary status contactors
• fault of contactor control wiring (command and
feedback)
• fault of binary input converter card (2B: G151, 2A:
G103)
• fault of binary output contactor drive (2B: C019, 2A:
G119 for K141; 2B: C011, 2A: G127 for K142)
action to repair • exchange faulty contactor
• repair control wiring
• exchange faulty binary input converter care
• exchange faulty binary output contactor drive
SIEMENS-event code 44
notes
event code and diagnosis message 2033 SIV: TORQUE SUPERVISION DRIVE A
event code and diagnosis message 2053 SIV: TORQUE SUPERVISION DRIVE B
event code and diagnosis message 2091 SIV: CHOPPER A HAS OPEN OR SHORT
CIRCUIT
description The measured mean value for the chopper current A is less
than 50 A, while the calculated value (from DC-bus
voltage and chopper modulation degree) is higher than 100
A or chopper A current is 200 A higher than chopper B
current. If these conditions are fulfilled for more than 2 s
the message will be stored.
software detection by CPU (G011) [T4]
protection reactions: No
possible reasons • chopper fault
• grid fault (e.g. grid failed open)
• fault of chopper current measuring device
action to repair • eliminate chopper fault
• correct grid fault
• repair/exchange faulty chopper current measuring
device
SIEMENS-event code
notes
event code and diagnosis message 2092 SIV: CHOPPER B HAS OPEN OR SHORT
CIRCUIT
description The measured mean value for the chopper current B is less
than 50 A, while the calculated value (from DC-bus
voltage and chopper modulation degree) is higher than 100
A or chopper B current is 200 A higher than chopper A
current. If these conditions are fulfilled for more than 2 s
the message will be stored.
software detection by CPU (G011) [T4]
protection reactions: No
possible reasons • chopper fault
• grid fault (e.g. grid failed open)
• fault of chopper current measuring device
action to repair • eliminate chopper fault
• correct grid fault
• repair/exchange faulty chopper current measuring
device
SIEMENS-event code
notes
2113+
event code and diagnosis message 2113 EXT: FAILURE AUXILIARY INVERTER
event code and diagnosis message 2114 EXT: FAILURE FIELD REGULATOR
event code and diagnosis message 2116 EXT: ENGINE DERATE PROTECTION
event code and diagnosis message 2117 EXT: TRUCK PLUG MONITORING
event code and diagnosis message 2118 EXT: MINIMUM ENGINE SPEED
SUPERVISION
description The engine speed is lower than the threshold set for the
enabling of the field regulator.
threshold 10 / 9.2 1/s (600 / 552 rpm) (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
excitation disabling of the field regulator
possible reasons • engine failure
• fault/failure of engine speed measuring device
action to reset Automatic reset of field regulator inhibit as soon as engine
speed is high enough.
action to repair • correct engine problem
• repair/exchange faulty speed measuring device
SIEMENS-event code
notes Secondary reactions will take place due to the inhibit of
the field regulator.
event code and diagnosis message 2120EXT: BOTH INVERTER JUMPERS ARE
MISSING
description Both inverter enable jumper located at X100 are missing
threshold No
software detection by G119
protection reactions: Transfer to drive shutdown mode
excitation Disable and re-enable
possible reasons • Wiring
• G119 card
action to repair • correct wiring problem
• replace G119 card
SIEMENS-event code
notes .
event code and diagnosis message 2121 EXT: FAILURE STEERING ENCORDER
event code and diagnosis message 2122 EXT: AUTO-LUBE IS NOT FUNCTIONING
event code and diagnosis message 2123 EXT: AXLE BOX OVERTEMPERATURE
event code and diagnosis message 2124 EXT:GRID FAN CONTROL CIRCUIT
FAILED
description Grid blower circuit current is outside expected range >10s
threshold Current must be >20A and with in expected values
software detection by L095
protection reactions: Contactor K191 is opened, propel is inhibited, fault light
and buzzer inform operator of problem.
20s after the fault has been logged retard is disabled
action to reset Reset is required using operator reset button once the truck
is at standstill.
possible reasons • Wiring
• Software settings for RG1, RG2, RG3, and Motor
resistance. (Set in User – Parameters)
• Grid blower current transducer (U171)
• L095 card
action to repair • Correct wiring problem
• Check/adjust software settings
• Replace U171
• Replace L095 card
SIEMENS-event code 43
notes This fault is serious, repair before sending to production
2201+
event code and diagnosis message 2201 START-UP SEQUENCE: K104 DOES NOT
OPEN
description After the power-up, the TCU will try to open K104, if the
feedback signals from K104 does not clearly indicate that
K104 is open. If the feedback signals still do not indicate
K104 to be open 10 s after the TCU tried to open K104,
the code 2201 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not continue with the next step
as long as the feedback signals from K104 do not indicate
K104 to be open.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair dc-voltage sensor if measuring too high
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2202 START-UP SEQUENCE: THE TROLLEY
RELATED CONTACTORS ARE OPEN
description After the power-up, the TCU will try to open K303/304,
CB301, K305, K306, K307 and K308, if the feedback
signals from these contactors do not clearly indicate that
they are open after 10 s
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not continue with the next step
as long as the feedback signals are not correct.
possible reasons • fault of trolley contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2203 START-UP SEQUENCE: GATE UNIT POWER
SUPPLY NOT ENABLED
description The TCU enables the Gate Unit power supply during the
start-up sequence. If the feedback signal from the Gate
Unit power supply does not indicate that the supply is
working within 5 s, the code 2203 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not continue with the next step
as long as the feedback does not indicate that the gate unit
power supply is working.
possible reasons • gate unit power supply failure
• fault of signal wiring (command and feedback signals
for the gate unit power supply)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair or exchange gate unit power supply
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2204 START-UP SEQUENCE: INVERTER TEST
DOES NOT TERMINATE
description The TCU performs an inverter test during the start-up
sequence. The message 2204 will be stored, if the test does
not terminate within 30 s.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not be terminated. No operation
is possible
possible reasons CPU software fault.
action to reset switch off / switch on - sequence TCU
action to repair CPU-software has to be corrected by SIEMENS.
SIEMENS-event code
notes
event code and diagnosis message 2205 START-UP SEQUENCE: K104 DOES NOT
CLOSE
description The TCU will try to close contactor K104 during the start-
up sequence (if start-up to normal operation). If the
feedback signals from K104 do not clearly indicate that
K104 is closed within 30 s, the event code 2205 will be
stored.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not be terminated as long as the
feedback signals do not indicate that K104 is closed.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • replace dc-bus voltage transducer if offset present
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2206 START-UP SEQUENCE: CB301 OR K306
ARE NOT CLOSED
description The TCU will try to close contactor CB301 and K306
during the start-up sequence (if start-up to normal
operation). If the feedback signals from these do not
clearly indicate that they are closed within 30 s
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not be terminated as long as the
feedback signals do not indicate that they are closed.
possible reasons • fault of contactor CB301 or K306
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2211 TRANS. TO DRIVE SHUTDOWN: DC-LINK
NOT DISCHARGED
description During the transition to “drive shutdown” the TCU will try
to discharge the bus with the choppers. If the measured
bus voltage does not indicate that the bus is discharged
within 10 s, event code 2211 will be stored.
software detection by CPU (G011) [T6]
protection reactions:
transition to “drive shutdown” The sequence will not continue with the next step until the
bus is discharged.
possible reasons • chopper fault
• fault of bus voltage measuring device
• TCU fault (suppressing chopper commands), check
diagnosis memory for other messages
action to reset switch off / switch on - sequence TCU
action to repair • correct chopper fault
• repair or exchange bus voltage measuring device
• correct TCU fault
SIEMENS-event code
notes
event code and diagnosis message 2212 TRANS. TO DRIVE SHUTDOWN: K104
DOES NOT OPEN
description During the transition to “drive shutdown” the TCU tries to
open K104. If the feedback signals do not clearly indicate
that K104 is open within 30 s, event code 2212 will be
stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “drive shutdown” will not continue with
the next step as long as the feedback signals from K104 do
not indicate that K104 is open.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • replace DC-bus voltage transducer if offset present
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2213 TRANS. TO DRIVE SHUTDOWN: THE
TROLLEY RELATED CONTACTORS ARE NOT
CORRECT
description During the transition to “drive shutdown”, the TCU will
try to open CB301 and close K306. If the feedback signals
do not indicate the contactors to be in the correct positions
30s after the TCU commands
software detection by CPU (G011) [T6]
protection reactions: The transition to “drive shutdown” will not continue with
the next step as long as the feedback signals are not
correct.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2216 TRANS. TO STB-IDLE: GATE UNIT
POWER SUPPLY NOT OK
description The TCU enables the Gate Unit power supply during the
transition to “standby-idle”. If the feedback signal from
the Gate Unit power supply does not indicate that the
supply is working within 10 s, the code 2216 will be
stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “standby-idle” will not continue with the
next step, as long as the feedback does not indicate that the
gate unit power supply is working.
possible reasons • gate unit power supply failure
• fault of signal wiring (command and feedback signals
for the gate unit power supply)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair or exchange gate unit power supply
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2217 TRANS. TO STB-IDLE: K104 DOES NOT
CLOSE
description The TCU will try to close contactor K104 during the
transition to “standby idle”. If the feedback signals from
K104 do not clearly indicate that K104 is closed within 30
s, the event code 2217 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “standby idle” will not continue with the
next step, as long as the feedback signals do not indicate
that K104 is closed.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • replace DC-bus voltage transducer if offset is found
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2218 TRANS. TO STB-IDLE: THE TROLLEY
RELATED CONTACTORS ARE NOT CORRECT
description During the transition to “stand by idle”, the TCU will try
to open K303/K304, K305, K307, K308. If any of these
feedback signals still do not indicate the contactors to be
opened 30s after TCU commands to open them
software detection by CPU (G011) [T6]
protection reactions: The standby idle sequence will not continue with the next
step as long as the feedback signals from the above
contactors do not indicate they are opened.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2221 IPM TURNOFF-SEQ.: K104 DOES NOT
OPEN
description During the “IPM turnoff-sequence” the TCU tries to open
K104. If the feedback signals do not clearly indicate that
K104 is open within 30 s, event code 2221 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The “IPM turnoff-sequence” will not continue with the
next step as long as the feedback signals from K104 do not
indicate that K104 is open.
possible reasons • fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2222 IPM TURNOFF-SEQ: K104 DOES NOT
CLOSE
description During the “IPM turnoff-sequence” the TCU tries to close
K104. If the feedback signals from K104 do not clearly
indicate that K104 is closed within 30 s, the event code
2222 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The “IPM turnoff-sequence” will not continue with the
next step, as long as the feedback signals do not indicate
that K104 is closed.
possible reasons • fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2223 IPM TURNOFF-SEQ.: FIELD REGULATOR
NOT ENABLED
description At the end of the “IPM turnoff-sequence” the TCU will
enable the field regulator. If the feedback does not indicate
that the field regulator is enabled within 5 s, the event
code 2223 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The “IPM turnoff sequence” will not terminate, as long as
the feedback does not indicate that field regulator is
working.
possible reasons • fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair or exchange field regulator
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2224 IPM TURNOFF-SEQ.: THE TROLLEY
RELATED CONTACTORS ARE NOT OPEN
description During the transition to “IPM TURNOFF-SEQ”, the TCU
will try to open K303/K304, K305, K307, K308. If any of
these feedback signals still do not indicate the contactors
to be open 30s after the TCU commands to open them
software detection by CPU (G011) [T6]
protection reactions: The standby idle sequence will not continue with the next
step as long as the feedback signals from the above
contactors do not indicate they are open.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2225 IPM TURNOFF-SEQ.: THE TROLLEY
RELATED CONTACTORS ARE NOT CLOSED
description During the transition to “IPM TURN-OFF ”, TCU will try
to close K306 and CB301. If the feedback signals from
K306 and CB301 don’t indicate that CB301 or K306 is
closed within 30s
software detection by CPU (G011) [T6]
protection reactions: The stand by idle sequence will not continue with the next
step as long as the feedback signals from the above
contactors do not indicate they are closed.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2231 POWER-DOWN SEQUENCE: K104 DOES NOT
OPEN
description During the power-down sequence the TCU tries to open
K104. If the feedback signals do not clearly indicate that
K104 is open within 10 s, event code 2231 will be stored.
software detection by CPU (G011) [T6]
protection reactions: no
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • replace DC-bus voltage transducer if offset is found
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2232 POWER-DOWN SEQUENCE: CB301 DOES
NOT OPEN
description During the transition to “POWER-DOWN”, the TCU will
try to open CB301. If any of these feedback signals still do
not indicate the contactors to be opened 30s after TCU
commands to open them
software detection by CPU (G011) [T6]
protection reactions: no
possible reasons • fault of contactor cb301
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • exchange contactor
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2234 ENGAGE SEQUENCE: TROLLEY ENGAGE
SEQUENCE INCOMPLETE
description During the transition from D3 to DBT sequence, the TCU
will try to raise pantograph, close K303/K304, open
K306, move K307 to position 2, close K305. If not in
trolley active mode 8s after TCU commands engage
software detection by CPU (G011) [T6]
protection reactions: The circuit breaker will be opened, lower pantograph and
go back to diesel mode.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
event code and diagnosis message 2235 DISENGAGE SEQUENCE: TROLLEY ENGAGE
SEQUENCE INCOMPLETE
description During the transition from DBT to D3 sequence, TCU
will try to open K305, move K307 to position 1, close
K306, open K303/K304, and low pantograph. If the
feedback signals don’t indicate the pantograph and
contactors correctly 8s after TCU commands them
software detection by CPU (G011) [T6]
protection reactions: The circuit breaker will be opened, lower pantograph and
go back to diesel mode.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes
Event code and diagnosis message 2249 WARNING: FEEDBACK SIGNAL K101
INCONSISTENT
Description The TCU tries to close contactor K101 as long as it is
operational. The event code 2249 will be stored if the
feedback indicates that K101 is open.
Software detection by CPU (G011) [T8]
Protection reactions: no
Possible reasons • fault of signal wiring (command and feedback signals
for K101)
• fault of contactor K101
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
Action to repair • repair control signal wiring, connect power and
feedback together to bypass status contactor.
• exchange contactor K101
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code 41
notes
2389+
Event code and diagnosis message 2389 BM: SERVICE BRAKE APPLICATION
ABOVE SPEED LIMIT
Description If the feedback from the service brake pedal indicates that
the pedal is pressed and the truck speed is higher than the
threshold, the event code 2389 is stored.
Threshold 5 mph
Software detection by CPU (G011) [T6]
Protection reactions: no
Possible reasons service brake application above speed limit
SIEMENS-event code
notes
Event code and diagnosis message 2392 DATA STORE SWITCH IS PRESSED
Description Log a code and save the current data into memory
Software detection by G127
Protection reactions: no
Possible reasons • Switch is pressed
• Wiring error
• G127 card
Action to repair Not necessary unless this code is active all the time, then
should try to correct the wiring or replace G127 card
SIEMENS-event code
notes
Event code and diagnosis message 2396 DM: FAILURE DIAGNOSIS MEMORY
Event code and diagnosis message 2397 DM: DIAGNOSIS MEMORY OCCUPATION >
75 %
Description The diagnosis memory occupation is higher than 75 %.
Software detection by CPU (G011) [T8]
Protection reactions: no
Possible reasons Many events stored in the diagnosis memory.
Action to reset Clear diagnosis memory.
SIEMENS-event code
Notes
Event code and diagnosis message 2398 DM: DIAGNOSIS MEMORY FULL