TRACTION DRIVES / SE&A

AC DRIVE HAUL TRUCK

System Fault Codes

Revision : 2.0
Date : 7/10/2003
Number of pages: 218
File Name: System codes.doc

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 1 of 218
TRACTION DRIVES / SE&A

Driver Information System ............................................................................................. 4


21- Drive shutdown (N1) 15hex 4
22-TCU-battery low (N2) 16hex 4
23-Serial link data not available (N3) 17hex 4
26-Limp mode inverter A (N6) 1A hex 5
27-Limp mode inverter B (N7) 1B hex 5
28-Propel Inhibit Switch (N8) 1C hex 5
37-Auto-lube is not functioning (W1) 25 hex 5
38-Axle box is over temperature (W1) 26 hex 5
40-Steering encoder failure (W1) 28 hex 5
41-Minor component failure (W2) 29 hex 6
42-Loss of propel to be expected (W3) 2A hex 6
43-Grid Blower Failure (W4) 2B hex 6
44-Drive failure (propulsion and retard) to be expected (W5) 2C hex 7
45-Overtemperature warning (W6) 2D hex 7
48-Differential oil pressure is low (W7) 30 hex 7
61-Propulsion torque reduction (P1) 3D hex 8
62-Retard torque reduction (P2) 3E hex 8
65-Power reduction (P5) 41 hex 8
66-Power reduction (P6) 42 hex 9
68-Propulsion torque reduction to zero (P8) 44 hex 9
69-Maximum system speed violation (P9) 45 hex 10
70-Engine Derate (P10) 46 hex 10
81-Temporary stop of inverter operation (T1) 51 hex 10
82-Temporary stop of inverter operation and excitation (T2) 52 hex 10
91-Stop of inverter operation (R1) 5B hex 11
92-Stop of inverter operation (R2) 5C hex 11
102-Limp mode possible after fault reset (C1) 66 hex 12
107-Propel Inhibit (C1) 6B hex 12
111-Severe drive component failure, After reset Limp mode possible (C2) 6F hex 12
112-Limp mode possible after disconnection of inverter A (C2) 70 hex 13
113-Limp mode possible after disconnection of inverter B (C3) 71 hex 13
114-Retard Inhibit (C4) 72 hex 13
115-Inverter and exciter operation not possible any more (C5) 73 hex 14
116-Component Over temperature (C6) 74 hex 14
117-Inhibit Active (C7) 75 hex 14
118-Request TCU shutdown (C8) 76 hex 14
121-Ground fault detected (G1) 79 hex 14
122-Ground fault drive shutdown resetable (G2) 7A hex 15
123-Ground fault drive shutdown not resetable (G3) 7B hex 15
202-GTO Module preheating active (Seq) CA hex 15
203-Precharging active (Seq) CB hex 15
205-Start-up sequence running (Seq) CD hex 15
206-Transition“standby idle” running(Seq) CE hex 15
207-IPM extinction sequence running (Seq) CF hex 15
208-Transition to “drive shutdown” running (Seq) D0 hex 16
209-Power-down sequence running (Seq) D1 hex 16
Fault finding .............................................................................................................. 17
TCU basic settings 17
Instruments, tools, measuring points 18
Software connector values 19

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 2 of 218
TRACTION DRIVES / SE&A
Diagnosis 24
System Faults (Event Statistic) List.............................................................................. 26
System faults (Event statistics) Complete descriptions ................................................ 33
100+ 59
350+ 71
603+ 84
703+ 97
800+ 110
910+ 117
1299+ 121
1423+ 125
Following this criteria help to locate the ground fault: 139
1511+ 141
1620+ 151
1729+ 168
1815+ 177
1963+ 179
2009+ 180
2113+ 185
2201+ 192
2389+ 215

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 3 of 218
TRACTION DRIVES / SE&A
Driver Information System

This document describes the operator’s information system of SIEMENS AC HAUL


TRUCK drives controlled by SIBAS®32 traction control units. The control system
provides a “SIEMENS event byte” in the serial link telegram, which can be used to
inform the truck operator about the drive status by means of a display. The
document describes the meaning of the codes sent in the “SIEMENS event byte”.

Event classification
The following chapters show the different levels of possible events. The tables contain a
code (preliminary, may be changed) and a possible text for the message on the display for
each level. The event code “00” indicates that no inhibit or special drive status is active.

Notifications
Notifications indicate events without influence on the truck operation, some should be
reported to the service personnel for corrective action.

21- Drive shutdown (N1) 15hex

21 NOTIFICATION: “drive shutdown” mode active


Check position of “drive shutdown” switch

22-TCU-battery low (N2) 16hex

22 NOTIFICATION: TCU-battery low


TCU battery must be replaced by qualified personnel

Note: Battery buffered data might be lost, if the battery will not be replaced in time.

16 |ZRES_0AQ| N/ |SYS: UNDERVOLTAGE TCU-BATTERY

23-Serial link data not available (N3) 17hex

23 NOTIFICATION: Serial link data not available


Correct problem when convenient

Note: All functions relying on commands coming from the serial link are not available.

800 |BUS2_0AQ| N/ |BUS: TIMEOUT-SUPERVISION RECEIVE MESSAGES FROM PC

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 4 of 218
TRACTION DRIVES / SE&A
26-Limp mode inverter A (N6) 1A hex

26 NOTIFICATION: limp mode inverter A active


Inverter B inactive. Seek service IMMEDIATELY

27-Limp mode inverter B (N7) 1B hex

27 NOTIFICATION: limp mode inverter B active


Inverter A inactive. Seek service IMMEDIATELY

28-Propel Inhibit Switch (N8) 1C hex

28 NOTIFICATION: Propel Inhibit


Propel Inhibit Switch Activated

Warnings
Warnings indicate events without immediate influence on truck operation, but service is
required soon. Component failures will cause a warning, if there’s no immediate effect
on truck operation. As the failure may influence the truck operation, if it is present for a
longer time, service is required as soon as possible

37-Auto-lube is not functioning (W1) 25 hex

37 WARNING: Auto-lube is not functioning


Service required as soon as possible

38-Axle box is over temperature (W1) 26 hex

38 WARNING: Axle box over temperature


Service required as soon as possible

40-Steering encoder failure (W1) 28 hex

40 WARNING: Steering Encoder Out of Range


Service required as soon as possible

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 5 of 218
TRACTION DRIVES / SE&A

41-Minor component failure (W2) 29 hex

41 WARNING: minor drive component failure


Service required. See troubleshooting manual

72 |SPPAI0AQ| W/1 |DSPA: FAILURE VOLTAGE TRANSDUCER U13 (T101)


73 |SPPAI0AQ| W/1 |DSPA: FAILURE VOLTAGE TRANSDUCER U23 (T102)
122 |SPPBI0AQ| W/1 |DSPB: FAILURE VOLTAGE TRANSDUCER U13 (T201)
123 |SPPBI0AQ| W/1 |DSPB: FAILURE VOLTAGE TRANSDUCER U23 (T201)
397 |HDWV_0AQ| W/1 |IO: HARDWARE-COMPARATOR FAULT
398 |HDWI_0AQ| W/1 |IO: FAILURE ADC IO FOR TCU TEMPERATURE (G035)
399 |HDWI_0AQ| W/1 |IO: TCU-TEMPERATURE OUT OF MEANINGFUL RANGE
663 |UWSA_0AQ| W/1 |UWSA: FAILURE MICROCONTROLLER UWS A (G071)
665 |UWSA_0AQ| W/1 |UWSA: FAILURE ADC UWS A (G071)
697|UWSA_0AQ| W/1 |UWSA: HARDWARE-COMPARATOR FAULT
763 |UWSB_0AQ| W/1 |UWSB: FAILURE MICROCONTROLLER UWS B (G079)
765 |UWSB_0AQ| W/1 |UWSB: FAILURE ADC UWS B (G079)
797 |UWSB_0AQ| W/1 |UWSB: HARDWARE-COMPARATOR FAULT
871 |ETM1_0AQ| W/1 |ETM: OPEN CIRCUIT PT100 ETM 1 (L131)
872 |ETM2_0AQ| W/1 |ETM: OPEN CIRCUIT PT100 ETM 2 (L139)
876 |ETM1_0AQ| W/1 |ETM: FAILURE ADC IO (G035) FOR TEMPERATURES OF ETM 1
877 |ETM2_0AQ| W/1 |ETM: FAILURE ADC IO (G035) FOR TEMPERATURES OF ETM 2
970 |HDWI_0AQ| W/1 |AIF: FAILURE ADC AIF (G087)
1299 |FUWK_0AQ| W/1 |START-UP TEST: FEEDBACK ERROR CONTACTOR K105
2249 |FUWK_0AQ| W/1 |WARNING: FEEDBACK SIGNAL K101 INCONSISTENT

42-Loss of propel to be expected (W3) 2A hex

42 WARNING: loss of propel to be expected


Power demand too high.

1513 TORQUE REDUCTION DUE TO THE I SQUARE TIME


1514 TORQUE REDUCTION DUE TO THE TORQUE SQUARE TIME
1517 alternator over current warning

43-Grid Blower Failure (W4) 2B hex

43 WARNING: Grid Blower Failure, Stop truck now!!


Grid Blower pressure switch bad / out of adjustment.
Grid Blower circuit current out of range >10s
** Propel disabled, Retard disabled after 20s of fault*****

1627 |FUWK_0AQ| W/2 |TMP: GRID BLOWER SUPERVISION


2124|ANSS_0AQ| EXT:GRID FAN CONTROL CIRCUIT FAILED

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 6 of 218
TRACTION DRIVES / SE&A

44-Drive failure (propulsion and retard) to be expected (W5) 2C hex

44 WARNING: drive failure to be expected


If the fault stays active then the truck should be driven to a
safe place and maintenance should be called.

17 |ZRES_0AQ| W/4 |SYS: TCU BLOWER FAILURE


1729 |FUWK_0AQ| W/4 |TMP: MAIN BLOWER SUPERVISION
2029 |ANSS_0AQ| W/4 |SIV: MAIN BLOWER CONTACTOR SUPERVISION
2115 |FUWK_0AQ| W/4 | EXT: OVERTEMPERATURE BATTERY CHARGER
2117 |FUWK_0AQ| W/4 |EXT: TRUCK PLUG MONITORING

45-Overtemperature warning (W6) 2D hex

45 WARNING: System over temperature


See troubleshooting manual for possible causes
1521 |FUWT_0AQ| W/6 |TMP: INVERTER MODULE TEMPERATURE A > APRS-LIMIT
1525 |FUWT_0AQ| W/6 |TMP: SNUBBER RESISTOR TEMPERATURE A > WARNING-LIMIT
1531 |FUWT_0AQ| W/6 |TMP: INVERTER MODULE TEMPERATURE B > APRS-LIMIT
1535 |FUWT_0AQ| W/6 |TMP: SNUBBER RESISTOR TEMPERATURE B > WARNING-LIMIT
1621 |FUWT_0AQ| W/6 |TMP: CHOPPER MODULE TEMPERATURE A > APRS-LIMIT
1628 |FUWT_0AQ| W/6 |TMP: RETARD GRID TEMPERATURE A > APRS-LIMIT
1631 |FUWT_0AQ| W/6 |TMP: CHOPPER MODULE TEMPERATURE B > APRS-LIMIT
1638 |FUWT_0AQ| W/6 |TMP: RETARD GRID TEMPERATURE B > APRS-LIMIT
1645 |FUWT_0AQ| W/6 |TMP: ALTERNATOR STATOR TEMPERATURE > APRS-LIMIT
1647 |FUWT_0AQ| W/6|TMP: ALTERNATOR BEARING TEMPERATURE > APRS-LIMIT
1648|FUWT_0AQ| W/6|TMP: ALTERNATOR BEARING TEMPERATURE > SHUT-LIMIT
1650 |FUWT_0AQ| W/6 |TMP: TRACTION MOTOR TEMPERATURE A > APRS-LIMIT
1651 |FUWT_0AQ| W/6 |TMP: TRACTION MOTOR TEMPERATURE B > APRS-LIMIT
1660 |FUWT_0AQ| W/6|TMP: TRACTION MOTOR BEARING TEMPERATURE A > WARN-LIMIT
1661 FUWT_0AQ| W/6|TMP: TRACTION MOTOR BEARING TEMPERATURE B > WARN-LIMIT
1663 FUWT_0AQ| W/6|TMP: TRACTION MOTOR BEARING TEMPERATURE A > SHUT-LIMIT",
1664 FUWT_0AQ| W/6|TMP: TRACTION MOTOR BEARING TEMPERATURE B > SHUT-LIMIT
1763 |FUWT_0AQ| W/6 |TMP: TEMPERATURE TCU > APRS-LIMIT
1778 |FUWT_0AQ| W/6 |TMP: INVERTER COMPARTMENT TEMPERATURE > APRS-LIMIT

48-Differential oil pressure is low (W7) 30 hex

46 WARNING: Differential oil pressure is low


Truck speed is limited to 15 mph until pressure is no longer
low.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 7 of 218
TRACTION DRIVES / SE&A
Torque / power reduction

61-Propulsion torque reduction (P1) 3D hex

61 WARNING: propulsion torque reduction active !


APRS Temperature limit reached

1521 |FUWT_0AQ| M/ |TMP: INVERTER MODULE TEMPERATURE A > APRS-LIMIT


1525 |FUWT_0AQ| M/ |TMP: SNUBBER RESISTOR TEMPERATURE A > APRS-LIMIT
1531 |FUWT_0AQ| M/ |TMP: INVERTER MODULE TEMPERATURE B > APRS-LIMIT
1535 |FUWT_0AQ| M/ |TMP: SNUBBER RESISTOR TEMPERATURE B > APRS-LIMIT
1621 |FUWT_0AQ| M/ |TMP: CHOPPER MODULE TEMPERATURE A > APRS-LIMIT
1628 |FUWT_0AQ| P/2 |TMP: RETARD GRID TEMPERATURE A > APRS-LIMIT
1631 |FUWT_0AQ| M/ |TMP: CHOPPER MODULE TEMPERATURE B > APRS-LIMIT
1638 |FUWT_0AQ| P/2 |TMP: RETARD GRID TEMPERATURE B > APRS-LIMIT
1645 |FUWT_0AQ| P/1 |TMP: ALTERNATOR STATOR TEMPERATURE > APRS-LIMIT
1650 |FUWT_0AQ| M/ |TMP: TRACTION MOTOR TEMPERATURE A > APRS-LIMIT
1651 |FUWT_0AQ| M/ |TMP: TRACTION MOTOR TEMPERATURE B > APRS-LIMIT
1778 |FUWT_0AQ| M/ |TMP: INVERTER COMPARTMENT TEMPERATURE > APRS-LIMIT

62-Retard torque reduction (P2) 3E hex

62 WARNING: retard torque reduction active !


APRS Temperature limit reached.

1621 |FUWT_0AQ| M/ |TMP: CHOPPER MODULE TEMPERATURE A > APRS-LIMIT


1628 |FUWT_0AQ| P/2 |TMP: RETARD GRID TEMPERATURE A > APRS-LIMIT
1631 |FUWT_0AQ| M/ |TMP: CHOPPER MODULE TEMPERATURE B > APRS-LIMIT
1638 |FUWT_0AQ| P/2 |TMP: RETARD GRID TEMPERATURE B > APRS-LIMIT
1650 |FUWT_0AQ| M/ |TMP: TRACTION MOTOR TEMPERATURE A > APRS-LIMIT
1651 |FUWT_0AQ| M/ |TMP: TRACTION MOTOR TEMPERATURE B > APRS-LIMIT
1778 |FUWT_0AQ| M/ |TMP: INVERTER COMPARTMENT TEMPERATURE > APRS-LIMIT

65-Power reduction (P5) 41 hex

65 WARNING: propulsion power reduction active !


Alternator over temperature.

1646 |FUWT_0AQ| M/ | TMP: ALTERNATOR STATOR TEMPERATURE > SHUTDOWN-LIMIT

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 8 of 218
TRACTION DRIVES / SE&A

66-Power reduction (P6) 42 hex

66 WARNING: retard power reduction active !


Grid box over temperature

1629 |FUWT_0AQ| M/ | TMP: RETARD GRID TEMPERATURE A > SHUTDOWN-LIMIT


1639 |FUWT_0AQ| M/ | TMP: RETARD GRID TEMPERATURE B > SHUTDOWN-LIMIT

68-Propulsion torque reduction to zero (P8) 44 hex

68 WARNING: propulsion torque reduced to zero !


Shift lever validation error.

1963 |BEFA_0AQ| P/8 |BEF: SHIFT LEVER VALIDATION FAILURE

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 9 of 218
TRACTION DRIVES / SE&A

69-Maximum system speed violation (P9) 45 hex

69 WARNING: Propulsion torque reduced to zero !


max. system speed violation: reduce speed !

1815 |FUWB_0AQ| P/9 |DRZ: MAXIMUM SPEED VIOLATION (SYSTEM/MOTORS)

70-Engine Derate (P10) 46 hex

70 WARNING: Engine Derate Active


Engine fault active, stop truck and consult engine computer
for active codes

2116 |FUWK_0AQ| P/10 |EXT: ENGINE DERATE PROTECTION

Temporary drive faults

81-Temporary stop of inverter operation (T1) 51 hex

The inverter resumes operation after 2 s automatically, if no failure is present any more.

81 Temporary drive fault (2 s)


Call service if system does not recover automatically !

70 |SPPAI0AQ| T/1 |DSPA: OVERCURRENT


120 |SPPBI0AQ| T/1 |DSPB: OVERCURRENT
350 |HDWS_0AQ| T/1 |IO: OVERVOLTAGE DC-LINK, 1. LEVEL (PIN X2.F2)
662 |UWSA_0AQ| T/1 |UWSA: SUPERVISION SWITCHING FREQUENCY
762 |UWSB_0AQ| T/1 |UWSB: SUPERVISION SWITCHING FREQUENCY
1458 |FUWB_0AQ| T/1 |IUW: DC-LINK VOLTAGE OUT OF ENVELOPE IN PROPEL
1459 |FUWB_0AQ| T/1 |IUW: DC-LINK VOLTAGE OUT OF ENVELOPE IN RETARD

82-Temporary stop of inverter operation and excitation (T2) 52 hex

The field regulator and the inverter resume operation after 10...15 s automatically, if no
failure is present any more.

82 Temporary drive fault (15 s)


Call service if system does not recover automatically !

1460 |FUWB_0AQ| T/2 |IUW: DC-LINK UNDERVOLTAGE SUPERVISION


2113 |FUWB_0AQ| T/2 |EXT: FAILURE AUXILIARY INVERTER
2114 |FUWB_0AQ| T/2 |EXT: FAILURE FIELD REGULATOR

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 10 of 218
TRACTION DRIVES / SE&A

Resetable drive faults


Resetable drive faults indicate events, that stop excitation and/or inverter operation, until
the driver resets the fault with the reset switch/button. The Reset can only be performed
at standstill.

91-Stop of inverter operation (R1) 5B hex

91 drive fault: inverter operation stopped


Inhibit active reset at standstill required

92-Stop of inverter operation (R2) 5C hex

92 drive fault: inverter operation stopped


Field regulator inhibit active reset at standstill required

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 11 of 218
TRACTION DRIVES / SE&A

Severe drive component failures


These faults will stop inverter operation or excitation, until corrective action and reset has
been performed by the service personnel. When limp mode is activated the truck should
be driven only as far as necessary to get to a safe place then service should be called.

102-Limp mode possible after fault reset (C1) 66 hex

102 drive fault: inverter operation stopped


Motor speed sensor faulty, press reset to go to limp mode

Both speed wheel motor speed sensors have failed.

107-Propel Inhibit (C1) 6B hex

107 drive fault: Propel Inhibit


Propel inhibited due to temperature

1622 |FWT_0AQ| C/1 |TMP: CHOPPER MODULE TEMPERATURE A > SHUTDOWN-LIMIT


1629 |FUWT_0AQ| C/1 |TMP: RETARD GRID TEMPERATURE A > SHUTDOWN-LIMIT
1632 |FUWT_0AQ| C/1 |TMP: CHOPPER MODULE TEMPERATURE B > SHUTDOWN-LIMIT
1639 |FUWT_0AQ| C/1 |TMP: RETARD GRID TEMPERATURE B > SHUTDOWN-LIMIT
1779 |FUWT_0AQ| C/1 |TMP: INVERTER COMPARTMENT TEMPERATURE > SHUTDOWN-LIMIT

111-Severe drive component failure, After reset Limp mode possible (C2) 6F hex

111 Severe drive component failure


Major drive component failure, press reset for limp mode.

83 |SPPAI0AQ| C/1 |PWRA: STROMWANDLER R DEFEKT


84 |SPPAI0AQ| C/1 |PWRA: STROMWANDLER T DEFEKT
102 |SPVB_0AQ| C/1 |DSPB: BUSY-MONITORING DSP B (G027)
106 |SPPBI0AQ| C/1 |DSPB: INITIALIZATION FAULT DSP B (G027)
107 |SPPBI0AQ| C/1 |DSPB: TIME-SLICE OVERFLOW DSP B T1
108 |SPPBI0AQ| C/1 |DSPB: TIME-SLICE OVERFLOW DSP B T2
109 |SPPBI0AQ| C/1 |DSPB: TIME-SLICE OVERFLOW DSP B T3
110 |SPPBI0AQ| C/1 |DSPB: TIME-SLICE OVERFLOW DSP B T4
121 |SPPBI0AQ| C/1 |DSPB: PARAMETER FAULT BRAKING CHOPPER FREQUENCY
133 |SPPBI0AQ| C/1 |PWRB: STROMWANDLER R DEFEKT
134 |SPPBI0AQ| C/1 |PWRB: STROMWANDLER T DEFEKT
666 |UWSA_0AQ| C/1 |UWSA: PARAMETER OR HARDWARE FAULT UWS A (G071)
667 |FUWB_0AQ| C/1 |UWSA: PEAK CURRENT PROT. DURING INVERTER-START-PHASE
669 |UWSA_0AQ| C/1 |UWSA: PEAK CURRENT COUNTER PROTECTION INVERTER
697 |HDWV_0AQ| C/1 |UWSA: HARDWARE-COMPARATOR FAULT
766 |UWSB_0AQ| C/1 |UWSB: PARAMETER OR HARDWARE FAULT UWS B (G079)
767 |FUWB_0AQ| C/1 |UWSB: PEAK CURRENT PROT. DURING INVERTER-START-PHASE
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 12 of 218
TRACTION DRIVES / SE&A
769 |UWSB_0AQ| C/1 |UWSB: PEAK CURRENT COUNTER PROTECTION INVERTER
797 |HDWV_0AQ| C/1 |UWSB: HARDWARE-COMPARATOR FAULT
1423 |FUWB_0AQ| C/1 |IUW: OUTPUT CURRENT SUPERVISION (IDLE) INV A
1424 |FUWB_0AQ| C/1 |IUW: OUTPUT CURRENT SUPERVISION (IDLE) INV B
1522 |FUWT_0AQ| C/1 |TMP: INVERTER MODULE TEMPERATURE A > SHUTDOWN-LIMIT
1526 |FUWT_0AQ| C/1 |TMP: SNUBBER RESISTOR TEMPERATURE A > SHUTDOWN-LIMIT
1532 |FUWT_0AQ| C/1 |TMP: INVERTER MODULE TEMPERATURE B > SHUTDOWN-LIMIT
1536 |FUWT_0AQ| C/1 |TMP: SNUBBER RESISTOR TEMPERATURE B > SHUTDOWN-LIMIT
1653 |FUWT_0AQ| C/1 |TMP: TRACTION MOTOR TEMPERATURE A > SHUTDOWN-LIMIT
1654 |FUWT_0AQ| C/1 |TMP: TRACTION MOTOR TEMPERATURE B > SHUTDOWN-LIMIT

112-Limp mode possible after disconnection of inverter A (C2) 70 hex

112 severe drive component failure


limp mode possible after disconnection of inverter A

e.g. module failures inverter A.


354 |FUWB_0AQ| C/2 |IO: OVERCURRENT BRAKING CHOPPER B (PIN X2.F06)

113-Limp mode possible after disconnection of inverter B (C3) 71 hex

113 severe drive component failure


limp mode possible after disconnection of inverter B

e.g. module failures inverter B.


353 |FUWB_0AQ| C/3 |IO: OVERCURRENT BRAKING CHOPPER A (PIN X2.D04)

114-Retard Inhibit (C4) 72 hex

114 Retard Inhibit


Retard Inhibit due to over temperature (Cool Grids)

1622 |FUWT_0AQ| C/1 |TMP: CHOPPER MODULE TEMPERATURE A > SHUTDOWN-LIMIT


1629 |FUWT_0AQ| C/1 |TMP: RETARD GRID TEMPERATURE A > SHUTDOWN-LIMIT
1632 |FUWT_0AQ| C/1 |TMP: CHOPPER MODULE TEMPERATURE B > SHUTDOWN-LIMIT
1639 |FUWT_0AQ| C/1 |TMP: RETARD GRID TEMPERATURE B > SHUTDOWN-LIMIT
1779 |FUWT_0AQ| C/1 |TMP: INVERTER COMPARTMENT TEMPERATURE > SHUTDOWN-LIMIT

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 13 of 218
TRACTION DRIVES / SE&A

115-Inverter and exciter operation not possible any more (C5) 73 hex

115 Severe drive component failure


Inverter and excitation inhibit: service required !

1311 |FUWK_0AQ| C/4 |HL: POWER-SUPPLY FAILURE GATE UNIT


1315 |FUWK_0AQ| C/4 |HL: FAILURE CROWBAR CURRENT DETECTION
1629 |FUWT_0AQ| C/4 |TMP: RETARD GRID TEMPERATURE A > SHUTDOWN-LIMIT
1639 |FUWT_0AQ| C/4 |TMP: RETARD GRID TEMPERATURE B > SHUTDOWN-LIMIT
1646 |FUWT_0AQ| C/4 |TMP: ALTERNATOR STATOR TEMPERATURE > SHUTDOWN-LIMIT
1519 |FUWB_0AQ| C/4 |IUW: OVERCURRENT DC-LINK
1779 |FUWT_0AQ| C/4 |TMP: INVERTER COMPARTMENT TEMPERATURE > SHUTDOWN-LIMIT
1820 |IWDR_0AQ| C/4 |DRZ: ROTATION DIRECTION INCONSISTENCY A/B

116-Component Over temperature (C6) 74 hex

116 Component over temperature


Excitation Inhibit due to over temperature

1765 |FUWT_0AQ| C/6 |TMP: OVERTEMPERATURE TCU: REQUEST TCU-SHUTDOWN

117-Inhibit Active (C7) 75 hex

117 Excitation Inhibit active


Must be cleared for normal operation

118-Request TCU shutdown (C8) 76 hex

118 TCU overheating


Shutdown TCU at standstill ! Service required !

Ground fault

121-Ground fault detected (G1) 79 hex

121 ground fault detected


PROPEL inhibit / RETARD possible to standstill

1470 |FUWK_0AQ| S/ |IUW: GROUND FAULT DETECTED

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 14 of 218
TRACTION DRIVES / SE&A

122-Ground fault drive shutdown resetable (G2) 7A hex

122 drive shutdown because of ground fault


RESET Not Possible: Service Required

123-Ground fault drive shutdown not resetable (G3) 7B hex

123 drive shutdown because of ground fault


RESET Possible

Sequences
202
202-GTO Module preheating active (Seq) CA hex

203
203-Precharging active (Seq) CB hex

205
205-Start-up sequence running (Seq) CD hex

206
206-Transition“standby idle” running(Seq) CE
hex

207
207-IPM extinction sequence running (Seq) CF
hex

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 15 of 218
TRACTION DRIVES / SE&A

208
208-Transition to “drive shutdown” running
(Seq) D0 hex

209
209-Power-down sequence running (Seq) D1 hex

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 16 of 218
TRACTION DRIVES / SE&A

Fault finding
Introduction

TCU basic settings

Digital potentiometer
The digital potentiometer on module G011 has to be set to "7". Any other setting is not
allowed for normal service without explicit permission from SIEMENS.
The digital potentiometer on module G035 is not used on this project. The setting is not
relevant.
Exchange of TCU modules and components
If it is necessary to replace any of the TCU modules the following rules have to be
observed:
### Modules may be withdrawn or inserted only when they are de-energized, i.e.
the control unit must be switched off and the front plug connector of the relevant module
must be removed.
### Modules with adjustable hardware elements ("variant modules", e.g. with
resistors), must be replaced by identically adjusted modules. If the new module is ordered
with the complete ordering designation the adjustable elements are correctly set.
TCU module settings
All variable complements and settings on the modules of the TCU are specified in the
corresponding TCU hardware adjustment instructions.

Resistors: All resistors are of type E0207 (0.28W, 85°C), tolerance 0.1%, unless
otherwise specified.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 17 of 218
TRACTION DRIVES / SE&A

Fault finding

Instruments, tools, measuring points

High-impedance low-capacitance measuring instruments should always be employed for


all measurements at the SIBAS control units. The measuring points for the relevant signal
are to be found in the traction control unit circuit diagrams.

Most of the analog signals used by the traction control unit can be measured via a
transient recorder
(6FH 9388). For this purpose the transient recorder, must be installed in slots G003 &
G043. The analog signals are now decoupled and available on front connector X3 for
measuring purposes.

The M bus bar on the terminal strip is employed as the measuring reference point for
external signals. For internal signals (e.g. TTL level) the common M strip conductor is
employed as a reference point, e.g. the M socket, or the pins b2 / b32 at the back plane
plug connector of the corresponding module. In the case of the MC modules (modules
with direct connection to the computer bus via the bus module) only the input and the
output signals (which are all decoupled) may be measured in addition to the signals at the
measuring sockets provided for this purpose.

Internal signals, which are not decoupled, may not be measured on account of the
danger of interference.

The generally applicable ESD rules should be observed for all measurements (refer
to Hardware documentation).

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 18 of 218
TRACTION DRIVES / SE&A

Software connector values

A frequently cause of drive faults are faults of the measured values. The following table
shows which TCU cards evaluate which measured values and the corresponding signal
names in the TCU software.

Attention: This table is valid for TCUs 6FH4272-2B !

voltages:

Measured value transducer/ TCU cards TCU software remarks


sensor connector name
Trolley voltage U301 L071, G035 $UN (CPU)
Ground voltage U106 L079, G035 $UGG (CPU) hardware filtered
(20 ms)
DC-link voltage U105 L055, G019 DU1_UDIS (DSP
A)
$UDISTZA (CPU)
L055, G071 $UDIUWSA (CPU)
L055, $UDIUWSB (CPU)
G071, G079
L063, G027 DU1_UDIS (DSP
B)
$UDISTZB (CPU)
L055, L079, $UDI_IO (CPU) hardware filtered
G035 (94 µs)
L055, L087, $UDIGHW2 (CPU) hardware filtered
G035 (20 ms)
L055, L087, $UDIGHW1 (CPU) hardware filtered (2
G035 µs)
Phase to phase T101 L055, G019 U_13 (DSP A)
voltage R-T, motor
A
Phase to phase T102 L055, G019 U_23 (DSP A)
voltage S-T, motor
A
Phase to phase T201 L063, G027 U_13 (DSP B)
voltage R-T, motor
B
Phase to phase T202 L063, G027 U_23 (DSP B)
voltage S-T, motor
B
throttle pedal L079, G035 $UTP (CPU)

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 19 of 218
TRACTION DRIVES / SE&A
voltage
Retard pedal L079, G035 $URP (CPU)
voltage

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 20 of 218
TRACTION DRIVES / SE&A
currents:

Measured value transducer/ TCU cards TCU software remarks


sensor connector name
Trolley current U108 L071, G035 $IN (CPU)
DC-link current U107 L071, G035 $IDIGHW (CPU) hardware filtered
(20 ms)
Chopper current A U104 L055, G019 I_BST (DSP A)
$IBTGZA (CPU) software filtered
(20 ms)
L055, G035 $IBTA (CPU) hardware filtered
(100 µs)
Chopper current B U204 L063, G027 I_BST (DSP B)
$IBTGZB (CPU) software filtered
(20 ms)
L063, G035 $IBTB (CPU) hardware filtered
(100 µs)
Inverter output U101 L055, G019 I_S1S (DSP A)
current A, phase R
L055, G071 $IL1PWRA (CPU)
Inverter output U102 L055, G019 I_S2S (DSP A)
current A, phase S
L055, G071 $IL2PWRA (CPU)
Inverter output U103 L055, G019 I_S3S (DSP A)
current A, phase T
L055, G071 $IL3PWRA (CPU)
Inverter output U201 L063, G027 I_S1S (DSP B)
current B, phase R
L063, G079 $IL1PWRB (CPU)
Inverter output U202 L063, G027 I_S2S (DSP B)
current B, phase S
L063, G079 $IL2PWRB (CPU)
Inverter output U203 L063, G027 I_S3S (DSP B)
current B, phase T
L063, G079 $IL3PWRB (CPU)

speed values:

Measured value transducer/ TCU cards TCU software remarks


sensor connector name
motor speed A E101 L071, G019 NIST_1 (DSP A)
$NIST1ZA (CPU) (software filtered
5 ms)
motor speed B E102 L071, G027 NIST_1 (DSP B)
$NIST1ZB (CPU) (software filtered
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 21 of 218
TRACTION DRIVES / SE&A
5 ms)
Engine speed L071, G019 NIST_3 (DSP A)
$NIST3ZA (software filtered
5 ms)

temperatures:

Measured value transducer/ TCU cards TCU software remarks


sensor connector name
Inverter A module F101 L131, G035 $C_ETM11 (CPU)
temperature A
Inverter A module F102 L131, G035 $C_ETM12 (CPU)
temperature B
Inverter A module F103 L131, G035 $C_ETM13 (CPU)
temperature C
Chopper module F104 L131, G035 $C_ETM14 (CPU)
temperature A
Inverter B module F201 L131, G035 $C_ETM15 (CPU)
temperature A
Inverter B module F202 L131, G035 $C_ETM16 (CPU)
temperature B
Inverter B module F203 L131, G035 $C_ETM17 (CPU)
temperature C
Chopper module F204 L131, G035 $C_ETM18 (CPU)
temperature B
Inverter F107 L139, G035 $C_ETM21 (CPU)
compartment
temperature
Snubber resistor F105 L139, G035 $C_ETM22 (CPU)
temperature A
Snubber resistor F205 L139, G035 $C_ETM23 (CPU)
temperature B
motor temperature L139, G035 $C_ETM24 (CPU)
A
motor temperature L139, G035 $C_ETM25 (CPU)
B
grid temperature A L139, G035 $C_ETM26 (CPU)
grid temperature B L139, G035 $C_ETM27 (CPU)
Alternator L139, G035 $C_ETM28 (CPU)
temperature

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 22 of 218
TRACTION DRIVES / SE&A
sundries:

Percent horsepower L079, G035 $XHP (CPU)


Steering angle L079, G035 $WST (CPU)
fuel level L095, G087 $YFUEL (CPU)
Battery voltage L095, G087 $YVOLTM (CPU)
Engine coolant L095, G087 $TCOOL (CPU) (linearized)
temperature
oil pressure L095, G087 $YOILPRE
Battery current L095, G087 $YAMMET
air pressure L095, G087 $YAIRPRE

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 23 of 218
TRACTION DRIVES / SE&A

Diagnosis

The SIBAS32 diagnosis system stores all events, which are important for the evaluation
of the TCU process data. Therefore not every stored event means that a fault or a wrong
process status occurred.
Some events are only stored for commissioning or additional maintenance information.

The reasons for faults which restrict or prevent the traction system from fully operation
are mostly to be found outside of the TCU. Most of the time, by simply replacing the
appropriate TCU printed circuit board it is possible to locate, if the fault is within the
TCU or outside.

The diagnosis system stores always the current process data for every event

• TCU operation mode / time


• Status of contactors
• Status of the DSPs
• Status of the INVM
• Analog process data

A detailed explanation how to read the diagnosis system is given in chapter 2.

The following subsections show a list of all possible events stored in the diagnosis
memory and a description for each of these codes:

event code and diagnosis message

Description
Software detection by processor card (slot) [processing time slice]
Hardware detection by card performing the hardware supervision
Protection reactions:
Inverter GTO pulse inhibit
Excitation
Main circuit breaker
Drive shutdown
Possible reasons list of possible causes for the event
Action to reset procedure to reset the protection reactions and/or the
cause of the fault; the event and the fault reaction may
occur again after the reset

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 24 of 218
TRACTION DRIVES / SE&A
Action to repair advices how to eliminate the cause of the event
(corresponding to the sequence of possible reasons)
SIEMENS event-code code sent to the TCU-external diagnosis system via serial
link
Notes

Protection functions:

inverter GTO pulse inhibit:

“soft inhibit” ramp down torque request to zero with a slope of 8333 Nm/s
before stopping the inverter GTO-pulses
“medium ramp down torque request to zero within one second from
inhibit” maximum torque, before stopping the inverter GTO-pulses
Immediate inhibit inverter GTO-pulses without any torque ramp down
inhibit

fire crowbar : activation of the Inverter-Protection-Module

inhibit excitation : disabling of the field regulator by control signal

inhibit main circuit breaker : opening of the main circuit breaker by control
signal

drive shutdown : disconnection of the DC-link from the rectifier output by


contactor K104 (no drive operation is possible)

TCU versions:

“2B” : TCU 6FH4272-2B (for serial trucks)


“2A” : TCU 6FH4272-2A (for prototype trucks Euclid-Hitachi)

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 25 of 218
TRACTION DRIVES / SE&A

System Faults (Event Statistic) List

The following list shows all events, used by the SIBAS32 diagnosis system. They are
listed with the event code and a the long name. Codes which are not listed are not used on
AC HAUL TRUCK.

1 SYS: TIME SLICE OVERFLOW CPU T1


2 SYS: TIME SLICE OVERFLOW CPU T2
3 SYS: TIME SLICE OVERFLOW CPU T3
4 SYS: TIME SLICE OVERFLOW CPU T4
5 SYS: TIME SLICE OVERFLOW CPU T5
6 SYS: TIME SLICE OVERFLOW CPU T6
7 SYS: TIME SLICE OVERFLOW CPU T7
8 SYS: TIME SLICE OVERFLOW CPU T8
13 SYS: HARDWARE FAULT POWER START-UP UNIT ONLINE
14 SYS: TCU POWER SUPPLY FAILURE 24 V FOR PULSE AMPLIFIER
15 SYS: HARDWARE FAULT POWER START-UP UNIT (G163)
16 SYS: UNDERVOLTAGE TCU-BATTERY
17 SYS: TCU BLOWER FAILURE
20 SYS: TOTALLOCK
24 SYS: GENERAL PROTECTION
30 SYS: TCU POWER SUPPLY FAILURE 5 V
31 SYS: TCU POWER SUPPLY FAILURE -15 V
32 SYS: TCU POWER SUPPLY FAILURE +15 V
33 SYS: TCU POWER SUPPLY FAILURE +24 V
34 SYS: TCU POWER SUPPLY FAILURE -24 V
35 SYS: TCU POWER SUPPLY FAILURE PRIMARY
36 SYS: CLOCK FAILURE POWER START-UP UNIT (G163)
37 SYS: TCU RESET
42 SYS: HARDWARE-COMPARATOR TEST STOPPED
50 DSPA: FAILURE DSP A (G019)
51 DSPA: START-UP FAILURE DSP A (G019)
52 DSPA: BUSY-MONITORING DSP A (G019)
53 DSPA: SOFTWARE-TRACO DSP A (G019) HAS TRIGGERED
54 DSPA: SOFTWARE-TRACO DSP A (G019) FULL
56 DSPA: INITIALIZATION FAULT DSP A (G019)
57 DSPA: TIME-SLICE OVERFLOW DSP A T1
58 DSPA: TIME-SLICE OVERFLOW DSP A T2
59 DSPA: TIME-SLICE OVERFLOW DSP A T3
60 DSPA: TIME-SLICE OVERFLOW DSP A T4

70 DSPA: OVERCURRENT
71 DSPA: PARAMETER FAULT BRAKING CHOPPER FREQUENCY
72 DSPA: FAILURE VOLTAGE TRANSDUCER U13 (T101)
73 DSPA: FAILURE VOLTAGE TRANSDUCER U23 (T102)
74 DSPA: HSCX DATA FROM DSP B MISSING
76 DSPA: SUM OF OUTPUT CURRENTS NOT ZERO
77 DSPA: FAILURE V/F-CARD FOR DSP A (L055)
78 DSPA: PULSE-PATTERN FAULT AT HIGH FREQUENCY
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 26 of 218
TRACTION DRIVES / SE&A
79 DSPA: ACTIVE CURRENT CONTROLLER IN LIMITATION
80 DSPA: ACTIVE CURRENT REFERENCE VALUE IN LIMITATION
81 DSPA: BRAKING CHOPPER CONTROLLER IN LIMITATION
82 DSPA: PULSE-INHIBIT BY DSP A (G019)
85 DSPA: UNBALANCE PROTECTION INVERTER CURRENTS

100 DSPB: FAILURE DSP B (G027)


101 DSPB: START-UP FAILURE DSP B (G027)
102 DSPB: BUSY-MONITORING DSP B (G027)
103 DSPB: SOFTWARE-TRACO DSP B (G027) HAS TRIGGERED
104 DSPB: SOFTWARE-TRACO DSP A (G019) FULL
106 DSPB: INITIALIZATION FAULT DSP B (G027)
107 DSPB: TIME-SLICE OVERFLOW DSP B T1
108 DSPB: TIME-SLICE OVERFLOW DSP B T2
109 DSPB: TIME-SLICE OVERFLOW DSP B T3
110 DSPB: TIME-SLICE OVERFLOW DSP B T4

120 DSPB: OVERCURRENT


121 DSPB: PARAMETER FAULT BRAKING CHOPPER FREQUENCY
122 DSPB: FAILURE VOLTAGE TRANSDUCER U13 (T201)
123 DSPB: FAILURE VOLTAGE TRANSDUCER U23 (T201)
124 DSPB: HSCX DATA FROM DSP A MISSING
126 DSPB: SUM OF OUTPUT CURRENTS NOT ZERO
127 DSPB: FAILURE V/F-CARD FOR DSP B (L063)
128 DSPB: PULSE-PATTERN FAULT AT HIGH FREQUENCY
129 DSPB: ACTIVE CURRENT CONTROLLER IN LIMITATION
130 DSPB: ACTIVE CURRENT REFERENCE VALUE IN LIMITATION
131 DSPB: BRAKING CHOPPER CONTROLLER IN LIMITATION
132 DSPB: PULSE-INHIBIT BY DSP B (G027)
135 DSPB: UNBALANCE PROTECTION INVERTER CURRENTS

350 IO: OVERVOLTAGE DC-LINK, 1. LEVEL (PIN X2.F2)


351 IO: OVERVOLTAGE DC-LINK, 2. LEVEL (PIN X2.D2)
353 IO: OVERCURRENT BRAKING CHOPPER A (PIN X2.D04)
354 IO: OVERCURRENT BRAKING CHOPPER B (PIN X2.F06)
355 IO: OVERCURRENT DC-LINK (PIN X2.D6)
356 IO: OVERVOLTAGE TROLLEY (PIN X2.F08)
358 IO: OVERCURRENT TROLLEY (PIN X2.B8)
360 IO: TEST-VOLTAGE IO-CARD NOT ZERO
361 IO: CLOCK-SUPERVISION ABIN 1 (2B:C003/2A:G119)
362 IO: CLOCK-SUPERVISION ABIN 2 (2B:C011/2A:G127)
363 IO: TCU PLUG-MONITORING
367 IO: PROCESS SUPERVISION CPU (G011)
368 IO: CPU-RESET
370 IO: SUPERVISION BUS-CLOCK IO
371 IO: SUPERVISION PCB-CLOCK IO (G035)
372 IO: INCORRECT VERSION FPGA IO (G035)
373 IO: INCORRECT APPLICATION VERSION FPGA IO (G035)
375 IO: FAILURE ADC IO (G035)
376 IO: INCORRECT VERSION IO-CARD (G035)
381 IO: PROCESS SUPERVISION DSP A (G019)
382 IO: PROCESS SUPERVISION DSP B (G027)
384 IO: CLOCK-SUPERVISION ABIN 3 (2B:C019/2A:G151)
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 27 of 218
TRACTION DRIVES / SE&A
387 IO: CLOCK-SUPERVISION ABIN 4 (C027)
388 IO: CLOCK-SUPERVISION ABIN 5 (C035)
397 IO: HARDWARE-COMPARATOR FAULT
398 IO: FAILURE ADC IO FOR TCU TEMPERATURE (G035)
399 IO: TCU-TEMPERATURE OUT OF MEANINGFUL RANGE

603 UWSA: TCU POWER SUPPLY FAILURE 24 V FOR PULSE


AMPLIFIER
620 UWSA: GTO SWITCHING FAILURE A101-1
621 UWSA: GTO SWITCHING FAILURE A101-2
622 UWSA: GTO SWITCHING FAILURE A102-1
623 UWSA: GTO SWITCHING FAILURE A102-2
624 UWSA: GTO SWITCHING FAILURE A103-1
625 UWSA: GTO SWITCHING FAILURE A103-2
626 UWSA: GTO SWITCHING FAILURE A104
642 UWSA: OVERCURRENT INV A L1
643 UWSA: OVERCURRENT INV A L2
644 UWSA: OVERCURRENT INV A L3
645 UWSA: OVERVOLTAGE DC-LINK (GW5)
646 UWSA: SUPERVISION BUS-CLOCK UWS A
647 UWSA: SUPERVISION PCB-CLOCK UWS A (G071)
660 UWSA: INCORRECT VERSION FPGA UWS A (G071)
661 UWSA: INCORRECT APPLICATION VERSION FPGA UWS A (G071)
662 UWSA: SUPERVISION SWITCHING FREQUENCY
663 UWSA: FAILURE MICROCONTROLLER UWS A (G071)
664 UWSA: PEAK CURRENT PROTECTION INVERTER ACTIVE
665 UWSA: FAILURE ADC UWS A (G071)
666 UWSA: PARAMETER OR HARDWARE FAULT UWS A (G071)
667 UWSA: PEAK CURRENT PROT. DURING INVERTER-START-PHASE
668 UWSA: PEAK VOLTAGE PROTECTION DC-LINK ACTIVE
669 UWSA: PEAK CURRENT COUNTER PROTECTION INVERTER
697 UWSA: HARDWARE-COMPARATOR FAULT

703 UWSB: IPM CURRENT DETECTION (PIN X1.D12)


715 UWSB: IPM FEEDBACK SIGNAL
720 UWSB: GTO SWITCHING FAILURE A201-1
721 UWSB: GTO SWITCHING FAILURE A201-2
722 UWSB: GTO SWITCHING FAILURE A202-1
723 UWSB: GTO SWITCHING FAILURE A202-2
724 UWSB: GTO SWITCHING FAILURE A203-1
725 UWSB: GTO SWITCHING FAILURE A203-2
726 UWSB: GTO SWITCHING FAILURE A204
742 UWSB: OVERCURRENT INV B L1
743 UWSB: OVERCURRENT INV B L2
744 UWSB: OVERCURRENT INV B L3
745 UWSB: OVERVOLTAGE DC-LINK (GW5)
746 UWSB: SUPERVISION BUS-CLOCK UWS B
747 UWSB: SUPERVISION PCB-CLOCK UWS B (G079)
760 UWSB: INCORRECT VERSION FPGA UWS B (G079)
761 UWSB: INCORRECT APPLICATION VERSION FPGA UWS B (G079)
762 UWSB: SUPERVISION SWITCHING FREQUENCY
763 UWSB: FAILURE MICROCONTROLLER UWS B (G079)
764 UWSB: PEAK CURRENT PROTECTION INVERTER ACTIVE
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 28 of 218
TRACTION DRIVES / SE&A
765 UWSB: FAILURE ADC UWS B (G079)
766 UWSB: PARAMETER OR HARDWARE FAULT UWS B (G079)
767 UWSB: PEAK CURRENT PROT. DURING INVERTER-START-PHASE
768 UWSB: PEAK VOLTAGE PROTECTION DC-LINK ACTIVE
769 UWSB: PEAK CURRENT COUNTER PROTECTION INVERTER
797 UWSB: HARDWARE-COMPARATOR FAULT

800 BUS: SERIAL INTERFACE DATA RECEPTION FAILURE


819 BUS: SERIAL INTERFACE CARD FAILURE (G063)

850 TR: TRACO 1 HAS TRIGGERED


851 TR: TRACO 1 IS FULL
852 TR: TRACO 2 HAS TRIGGERED
853 TR: TRACO 2 IS FULL

871 ETM: OPEN CIRCUIT PT100 ETM 1 (L131)


872 ETM: OPEN CIRCUIT PT100 ETM 2 (L139)
873 ETM: OPEN CIRCUIT PT100 ETM 3 (L147)
876 ETM: FAILURE ADC IO (G035) FOR TEMPERATURES OF ETM 1
877 ETM: FAILURE ADC IO (G035) FOR TEMPERATURES OF ETM 2
878 ETM: FAILURE ADC IO (G035) FOR TEMPERATURES OF ETM 3

890 INCORRECT PCB-VERSION EBIN 1 (2B:G111/2A:G103)


891 INCORRECT PCB-VERSION EBIN 2 (2B:G119/2A:G111)

910 INCORRECT PCB-VERSION ABIN 1 (G119)


911 INCORRECT PCB-VERSION ABIN 2 (G127)
921 ABIN: DEFECTIVE OUTPUT TRANSISTOR ABIN 1 (C003)
923 ABIN: DEFECTIVE OUTPUT TRANSISTOR ABIN 3 (C019)
924 ABIN: DEFECTIVE OUTPUT TRANSISTOR ABIN 4 (C027)
925 ABIN: DEFECTIVE OUTPUT TRANSISTOR ABIN 5 (C035)
970 AIF: FAILURE ADC AIF (G087)

1299 START-UP TEST: FEEDBACK ERROR CONTACTOR K105

1311 HL: POWER-SUPPLY FAILURE GATE UNIT


1315 HL: FAILURE IPM CURRENT DETECTION

1330 HL: GTO-PULSE-TEST: TEST STOPPED


1423 IUW: OUTPUT CURRENT SUPERVISION (IDLE) INV A
1424 IUW: OUTPUT CURRENT SUPERVISION (IDLE) INV B
1450 IUW: PRECHARCHING SUPERVISION DC-LINK VOLTAGE 1
1451 IUW: PRECHARCHING SUPERVISION DC-LINK VOLTAGE 2
1453 IUW: PRECHARCHING SUPERVISION EXCITATION CURRENT1
1454 IUW: PRECHARCHING SUPERVISION EXCITATION CURRENT2
1456 IUW: TORQUE REDUCTION DUE TO TROLLEY CONDITIONS
1457 IUW: TORQUE REDUCTION DUE TO DC-LINK VOLTAGE
1458 IUW: DC-LINK VOLTAGE OUT OF ENVELOPE IN PROPEL
1459 IUW: DC-LINK VOLTAGE OUT OF ENVELOPE IN RETARD
1460 IUW: DC-LINK UNDERVOLTAGE SUPERVISION
1461 IUW: TROLLEY LINE UNDERVOLTAGE SUPERVISION

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 29 of 218
TRACTION DRIVES / SE&A
1463 IUW: TROLLEY LINE OVERVOLTAGE SUPERVISION
1470 IUW: GROUND FAULT DETECTED
1511 IUW: TROLLEY LINE CURRENT AND DC-LINK CURRENT
SUPERVISION UNDER TROLLEY MODE
1513 IUW: TORQUE REDUCTION DUE TO THE I SQUARE TIME
1514 IUW: TORQUE REDUCTION DUE TO THE TORQUE SQUARE TIME
1516 IUW: ALTERNATOR NEGATIVE CURRENT PROTECTION
1517 IUW: ALTERNATOR OVERCURRENT WARNING
1518 IUW: ALTERNATOR OVERCURRENT PROTECTION
1519 IUW: OVERCURRENT DC-LINK

1520 TMP: INVERTER MODULE TEMPERATURE A < OPERATION LIMIT


1521 TMP: INVERTER MODULE TEMPERATURE A > APRS-LIMIT
1522 TMP: INVERTER MODULE TEMPERATURE A > SHUTDOWN-LIMIT
1525 TMP: SNUBBER RESISTOR TEMPERATURE A > WARNING-LIMIT
1526 TMP: SNUBBER RESISTOR TEMPERATURE A > SHUTDOWN-LIMIT

1530 TMP: INVERTER MODULE TEMPERATURE B < OPERATION LIMIT


1531 TMP: INVERTER MODULE TEMPERATURE B > APRS-LIMIT
1532 TMP: INVERTER MODULE TEMPERATURE B > SHUTDOWN-LIMIT
1535 TMP: SNUBBER RESISTOR TEMPERATURE B > WARNING-LIMIT
1536 TMP: SNUBBER RESISTOR TEMPERATURE B > SHUTDOWN-LIMIT
1537 TMP: SNUBBER A/B DELTA T > SHUTDOWN-LIMIT

1620 TMP: CHOPPER MODULE TEMPERATURE A < OPERATION-LIMIT


1621 TMP: CHOPPER MODULE TEMPERATURE A > APRS-LIMIT
1622 TMP: CHOPPER MODULE TEMPERATURE A > SHUTDOWN-LIMIT
1627 TMP: GRID BLOWER SUPERVISION
1628 TMP: RETARD GRID TEMPERATURE A > APRS-LIMIT
1629 TMP: RETARD GRID TEMPERATURE A > SHUTDOWN-LIMIT

1630 TMP: CHOPPER MODULE TEMPERATURE B < OPERATION-LIMIT


1631 TMP: CHOPPER MODULE TEMPERATURE B > APRS-LIMIT
1632 TMP: CHOPPER MODULE TEMPERATURE B > SHUTDOWN-LIMIT
1638 TMP: RETARD GRID TEMPERATURE B > APRS-LIMIT
1639 TMP: RETARD GRID TEMPERATURE B > SHUTDOWN-LIMIT

1645 TMP: ALTERNATOR STATOR TEMPERATURE > APRS-LIMIT


1646 TMP: ALTERNATOR STATOR TEMPERATURE > SHUTDOWN-LIMIT
1647 TMP: ALTERNATOR BEARING TEMPERATURE > APRS-LIMIT
1648 TMP: ALTERNATOR BEARING TEMPERATURE > SHUTDOWN-LIMIT

1650 TMP: TRACTION MOTOR TEMPERATURE A > APRS-LIMIT


1651 TMP: TRACTION MOTOR TEMPERATURE B > APRS-LIMIT
1653 TMP: TRACTION MOTOR TEMPERATURE A > SHUTDOWN-LIMIT
1654 TMP: TRACTION MOTOR TEMPERATURE B > SHUTDOWN-LIMIT
1660 TMP: TRACTION MOTOR BEARING TEMPERATURE A > WARN-LIMIT
1661 TMP: TRACTION MOTOR BEARING TEMPERATURE B > WARN-LIMIT
1663 TMP: TRACTION MOTOR BEARING TEMPERATURE A > SHUT-LIMIT
1664 TMP: TRACTION MOTOR BEARING TEMPERATURE B > SHUT-LIMIT

1729 TMP: MAIN BLOWER SUPERVISION


1763 TMP: TEMPERATURE TCU > APRS-LIMIT

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 30 of 218
TRACTION DRIVES / SE&A
1764 TMP: TEMPERATURE TCU > SHUTDOWN-LIMIT
1765 TMP: OVERTEMPERATURE TCU: REQUEST TCU-SHUTDOWN
1778 TMP: INVERTER COMPARTMENT TEMPERATURE > APRS-LIMIT
1779 TMP: INVERTER COMPARTMENT TEMPERATURE > SHUTDOWN-LIMIT

1780 DRZ: FAILURE SPEED SENSOR A


1781 DRZ: FAILURE SPEED SENSOR B
1788 DRZ: SUPERVISION MOTOR SPEED A DSP
1789 DRZ: SUPERVISION MOTOR SPEED B DSP
1790 DRZ: SUPERVISION ENGINE SPEED DSP
1815 DRZ: MAXIMUM SPEED VIOLATION (SYSTEM/MOTORS)
1816 DRZ: MINIMUM VEHICLE SPEED SUPERVISION FOR TROLLEY
1820 DRZ: ROTATION DIRECTION INCONSISTENCY A/B

1963 BEF: SHIFT LEVER VALIDATION FAILURE

2009 REF: EXCITATION CURRENT SETPOINT VALUE SUPERVISION


2029 SIV: MAIN BLOWER CONTACTOR SUPERVISION
2031 SIV: SUPERVISION DC-LINK CONTROLLLER
2033 SIV: TORQUE SUPERVISION DRIVE A
2053 SIV: TORQUE SUPERVISION DRIVE B
2091 SIV: CHOPPER A HAS AN OPEN OR SHORT CIRCUIT
2092 SIV: CHOPPER B HAS OPEN OR SHORT CIRCUIT
2113 EXT: FAILURE AUXILIARY INVERTER
2114 EXT: FAILURE FIELD REGULATOR
2115 EXT: OVERTEMPERATURE BATTERY CHARGER
2116 EXT: ENGINE DERATE PROTECTION
2117 EXT: TRUCK PLUG MONITORING
2118 EXT: MINIMUM ENGINE SPEED SUPERVISION
2120 EXT: BOTH INVERTER JUMPERS ARE MISSING
2121 EXT: FAILURE STEERING ENCORDER
2122 EXT: AUTO-LUBE IS NOT FUNCTIONING
2123 EXT: AXLE BOX OVERTEMPERATURE
2124 EXT:GRID FAN CONTROL CIRCUIT FAILED

2201 START-UP SEQUENCE: K104 DOES NOT OPEN


2202 START-UP SEQUENCE: THE TROLLEY RELATED CONTACTORS ARE
OPEN
2203 START-UP SEQUENCE: GATE UNIT POWER SUPPLY NOT ENABLED
2204 START-UP SEQUENCE: INVERTER TEST DOES NOT TERMINATE
2205 START-UP SEQUENCE: K104 DOES NOT CLOSE
2206 START-UP SEQUENCE: CB301 OR K306 IS NOT CLOSED
2211 DRIVE-SHUTDOWN: DC-LINK NOT DISCHARGED
2212 DRIVE-SHUTDOWN: K104 DOES NOT OPEN
2213 TRANS. TO DRIVE-SHUTDOWN: THE TROLLEY RELATED
CONTACTORS ARE NOT CORRECT
2215 TRANS. TO STB-IDLE: FIELD REGULATOR NOT DISABLED
2216 TRANS. TO STB-IDLE: GATE UNIT POWER SUPPLY NOT OK
2217 TRANS. TO STB-IDLE: K104 DOES NOT CLOSE
2218 TRANS. TO STB-IDLE: THE TROLLEY RELATED CONTACTORS ARE
NOT CORRECT
2221 IPM TURNOFF-SEQ.: K104 DOES NOT OPEN
2222 IPM TURNOFF-SEQ.: K104 DOES NOT CLOSE

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 31 of 218
TRACTION DRIVES / SE&A
2223 IPM TURNOFF-SEQ.: FIELD REGULATOR NOT ENABLED
2224 IPM TURNOFF-SEQ.: THE TROLLEY RELATED CONTACTORS ARE
NOT OPEN
2225 IPM TURNOFF-SEQ.: THE TROLLEY RELATED CONTACTORS ARE
NOT CLOSED
2231 POWER-DOWN SEQUENCE: K104 DOES NOT OPEN
2232 POWER DOWN SEQUENCE: CB301 DOES NOT OPEN
2234 ENGAGE SEQUENCE: TROLLEY ENGAGE SEQUENCE
INCOMPLETE
2235 DISENGAGE SEQUENCE: TROLLEY DISENGAGE SEQUENCE INCOMPLETE
2249 WARNING: FEEDBACK SIGNAL K101 INCONSISTENT
2389 BM: SERVICE BRAKE APPLICATION ABOVE SPEED LIMIT
2392 DATA STORE SWITCH IS PRESSED

2396 DM: FAILURE DIAGNOSIS MEMORY


2397 DM: DIAGNOSIS MEMORY OCCUPATION > 75 %
2398 DM: DIAGNOSIS MEMORY FULL
2399 TEST EVENT

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 32 of 218
TRACTION DRIVES / SE&A

System faults (Event statistics) Complete descriptions

event code and diagnosis message 1 SYS: TIME-SLICE OVERFLOW CPU T1


2 SYS: TIME-SLICE OVERFLOW CPU T2
3 SYS: TIME-SLICE OVERFLOW CPU T3
4 SYS: TIME-SLICE OVERFLOW CPU T4
5 SYS: TIME-SLICE OVERFLOW CPU T5
6 SYS: TIME-SLICE OVERFLOW CPU T6
7 SYS: TIME-SLICE OVERFLOW CPU T7
8 SYS: TIME-SLICE OVERFLOW CPU T8
Description The processing of one time slice of the CPU-software did
not terminate within the allowed time.
Software detection by CPU (G011)
Protection reactions:
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • processing time overload
• defective CPU-card (G011)
action to reset switch off / switch on – sequence TCU
action to repair • software change (by SIEMENS)
• exchange CPU-card (G011)
SIEMENS-event code no (process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 33 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 13 SYS: HARDWARE FAULT POWER START-UP
UNIT ONLINE
Description A hardware fault of the power start-up unit (G163) is
detected during normal TCU operation.
Software detection by CPU (G011) [T6]
Protection reactions: propel inhibit
Propel inhibit override possible with dump body override switch
Possible reasons hardware fault of the power start-up unit (G163)
action to reset • override propel inhibit by pressing the dump body
override switch
• switch off / switch on – sequence TCU
action to repair replace defective power start-up unit (G163)
SIEMENS-event code
Notes

event code and diagnosis message 14 SYS: TCU POWER SUPPLY FAILURE 24V
FOR PULSE AMPLIFIER
Description
Software detection by CPU (G011) [T6]
Protection reactions: propel inhibit
Propel inhibit
Possible reasons
action to reset
action to repair
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 34 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 15 SYS:HARDWARE FAULT POWER START-UP


UNIT (G163)
Description The power-start up unit cannot be initialized properly.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons failure power start-up unit (G163)
action to reset switch off / switch on – sequence TCU
action to repair replace defective power start-up unit (G163)
SIEMENS-event code
Notes The start-up sequence for the drive system will not be
performed. No operation is possible.

event code and diagnosis message 16 SYS:UNDERVOLTAGE TCU-BATERY

Description The voltage of the TCU-battery dropped below 2,8 V.


Hardware/software detection by CPU (G011) [T8]
Protection reactions: no (diagnosis message only)
action to repair replace battery in blower subassembly
SIEMENS-event code 22
Notes In case of low battery voltage a loss of stored data (e.g.
diagnosis data) may occur.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 35 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 17 SYS: TCU BLOWER FAILURE

Description Minimum / maximum current supervision TCU fans.


Hardware detection by TCU blower subassembly
Software detection by CPU (G011) [T8]
Protection reactions: No (diagnosis only)
action to reset Switch off / switch on – sequence TCU
Possible reasons • defective blower
• defective back plane wiring between CPU (G011) and
blower subassembly
• defective CPU-card (G011)
action to repair • replace defective blower or blower subassembly
• repair defective back plane wiring between CPU
(G011) and blower subassembly
• replace defective CPU-card (G011)
SIEMENS-event code 44
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 36 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 20 SYS:TOTALLOCK

Description The „totallock“ is a hardware protection function


including the blocking of inverter GTO-pulses (not
braking chopper pulses!), the inhibit of the field-regulator,
and the opening of the main circuit breaker (CB301). It is
caused by different hardware protection functions (e.g.
over voltage detection, process supervision...). As long as
the totallock is active, the red LED on the IO-card (G035)
will be dark.
Software detection by CPU (G011) [T1]
Protection reactions:
Inverter GTO pulse inhibit Inverter A and B by hardware circuits
Excitation Inhibit by hardware circuit
Main circuit breaker Inhibit by hardware circuit
Possible reasons • over voltage DC-link, 2. Level (Code 350)
• test-voltage IO-card not zero (Code 360)
• clock-supervision ABIN 1 (Code 361)
• clock-supervision ABIN 2 (Code 362)
• TCU plug-monitoring (Code 363)
• process supervision CPU (Code 367)
• CPU-reset (Code 368)
• supervision bus-clock IO (Code 370)
• supervision PCB-clock IO (Code 371)
• process supervision DSP A (Code 381)
• process supervision DSP B (Code 382)
• clock supervision ABIN 3 (Code 384)
• clock supervision ABIN 4 (Code 387)
• clock supervision ABIN 5 (Code 388)
• TCU power supply failure 24 V for pulse amplifier
(Code 603)
• GTO switching failures inverter A (Codes 620 to 626)
• over current inverter A (Codes 642 to 644)
• over voltage DC-link (Code 645)
• supervision bus-clock UWS A (Code 646)
• supervision PCB-clock UWS A (Code 647)
• IPM feedback signal (Code 715)
• GTO switching failures inverter B (Codes 720 to 726)
• over current inverter B (Codes 742 to 744)
• over voltage DC-link (Code 745)

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 37 of 218
TRACTION DRIVES / SE&A
• supervision bus-clock UWS B (Code 746)
• supervision PCB-clock UWS B (Code 747)
action to repair Check diagnosis memory for event causing the totallock.
Notes

event code and diagnosis message 24 SYS: GENERAL PROTECTION

Description Memory access failure.


Detection by CPU protection mechanism
Protection reactions:
Inverter GTO pulse inhibit Inverter A and B by hardware circuits (totallock)
Crowbar Commanded by software [G10]
Excitation Inhibit by hardware circuit (totallock)
Main circuit breaker Inhibit by hardware circuit (totallock)
Possible reasons • defective CPU-card (G011)
• software fault
action to reset Switch off / switch on – sequence TCU
action to repair • replace defective CPU-card (G011)
• correct software (by SIEMENS)
SIEMENS-event code No (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 38 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 30 SYS: TCU POWER SUPPLY FAILURE 5 V

Description Under voltage supervision of TCU power supply 5 V.


Hardware detection by Power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit Inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • failure DC/DC-converter 24V/5V (C153)
• failure power start-up unit (G163)
• failure electronic card (causing short circuit to the 5 V
supply)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter (C153)
• replace defective power start-up unit (G163)
• replace defective electronic card
SIEMENS-event code no (as CPU process stops)
Notes The hardware protection functions (especially crowbar
firing) may not work properly any more, as they require a
5 V supply themselves.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 39 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 31 SYS: TCU POWER SUPPLY FAILURE -15 V

Description Under voltage supervision TCU power supply -15 V.


Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • failure DC/DC-converter 24V/-15V (C087)
• failure power start-up unit (G163)
• failure electronic card (causing short circuit to the -15
V supply)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter (C087)
• replace defective power start-up unit
• replace defective electronic card
SIEMENS-event code no (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 40 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 32 SYS: TCU POWER SUPPLY FAILURE +15 V

Description Under voltage supervision TCU power supply +15 V.


Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • failure DC/DC-converter 24V/15V (C069)
• failure power start-up unit
• failure electronic card (causing short circuit to the +15
V supply)
• short circuit caused by device (or wiring) supplied from
the TCU (throttle pedal, retard pedal, speed sensors of
engine and traction motors)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter (C069)
• replace defective power start-up unit (G163)
• replace defective electronic card
• replace defective TCU-external component or repair
defective wiring
SIEMENS-event code no (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 41 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 33 SYS: TCU POWER SUPPLY FAILURE +24 V

Description Under voltage supervision TCU power supply +24 V.


Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • failure DC/DC-converter 24V/24V (C105)
• failure power start-up unit
• failure electronic card (causing short circuit to the +24
V supply)
• failure caused by device (or its wiring) supplied from
the TCU (voltage and current transducers)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter (C105)
• replace defective power start-up unit (G163)
• replace defective electronic card
• replace defective TCU-external component or repair
defective wiring
SIEMENS-event code no (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 42 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 34 SYS: TCU POWER SUPPLY FAILURE -24 V

Description Under voltage supervision TCU power supply -24 V.


Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • failure DC/DC-converter 24V/-24V (C129)
• failure power start-up unit
• failure electronic card (causing short circuit to the -24
V supply)
• short circuit caused by device (or its wiring) supplied
from the TCU (voltage and current transducers)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter (C129)
• replace defective power start-up unit (G163)
• replace defective electronic card
• replace defective TCU-external component or repair
defective wiring
SIEMENS-event code no (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 43 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 35 SYS: TCU POWER SUPPLY FAILURE
PRIMARY
Description Under voltage supervision primary TCU power supply.
Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • power supply short circuit
• battery under voltage
action to reset switch off / switch on – sequence TCU
action to repair • eliminate short-circuit
• charge battery
SIEMENS-event code no (as CPU process stops)
Notes

event code and diagnosis message 36 SYS: CLOCK-FAILURE POWER START-UP


UNIT
Description FPGA-clock of power start-up unit (G163) failed.
Hardware detection by power start-up unit (G163)
Protection reactions: TCU switches OFF
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons component failure of power start-up unit
action to reset switch off / switch on – sequence TCU
action to repair replace defective power start-up unit
SIEMENS-event code no (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 44 of 218
TRACTION DRIVES / SE&A

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 45 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 37 SYS: TCU RESET

Description Pressing the red pushbutton on the CPU-card (G011)


causes a reset of the control system.
Hardware detection by power start-up unit (G163)
Protection reactions:
Inverter GTO pulse inhibit inverter A and B by hardware circuits (totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • failure of CPU-card (G011) if event occurs without
pressing the red pushbutton on the CPU-card (G011)
• failure of power start-up (G163) unit if event occurs
without pressing the red pushbutton on the CPU-card
(G011)
action to repair • replace defective CPU-card (G011)
• replace defective power start-up unit (G163)
SIEMENS-event code no (as CPU process stops)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 46 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 42 SYS: HARDWARE-COMPARATOR TEST


STOPPED
Description The hardware-comparator test during the TCU-self test
could not be performed or had to be stopped.
Software detection by CPU (G011), [T6]
Possible reasons • failure analog/digital converter IO-card (G035)
• failure analog/digital converter UWS-card (G071)
• failure analog/digital converter UWS-card (G079)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective IO-card (G035)
• replace defective UWS-card (G071)
• replace defective UWS-card (G079)
SIEMENS-event code No
Notes Analog/digital converter failures will be indicated with
separate fault codes.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 47 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 51 DSPA: START-UP FAILURE DSP A (G019)

Description A failure during the start-up sequence of DSP A (G019)


has been detected.
Software detection by CPU (G011) during start-up routine G9
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons failure DSP A (G019)
action to reset switch off / switch on – sequence TCU
action to repair replace defective DSP A (G019)
SIEMENS-event code No
Notes The power start-up sequence for the drive system will not
be performed. No operation is possible.

event code and diagnosis message 52 DSPA: BUSY-MONITORING DSP A (G019)

Description A failure of DSP A has been detected by the busy-


monitoring.
Software detection by CPU (G011) [T4]
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B
Excitation immediate inhibit
Main circuit breaker immediate inhibit
“drive shutdown” transition to “drive shutdown”
Possible reasons failure DSP A (G019)
action to reset switch off / switch on – sequence TCU
action to repair replace defective DSP A (G019)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 48 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 53 DSPA: SOFTWARE-TRACO DSP A (G019)


HAS TRIGGERED
Description Message for the commissioning personnel, event does not
indicate a failure.
Software detection by DSP A (G019) / CPU (G011)
Notes

event code and diagnosis message 54 DSPA: SOFTWARE-TRACO DSP A (G019)


FULL
Description All partitions of the DSP software transient recorder are
occupied. Message for the commissioning personnel,
event does not indicate a failure.
Software detection by DSP A (G019) / CPU (G011)
Notes

event code and diagnosis message 56 DSPA: INITIALIZATION FAULT DSP A


(G019)
Description Start-up check routines of DSP-software detected a fault.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit inhibit inverter A and B
Main circuit breaker
“drive shutdown” startup to “drive shutdown”
Possible reasons failure DSP-card A (G019)
action to reset switch off / switch on – sequence TCU
action to repair replace defective DSP-card (G019)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 49 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 57 DSPA: TIME-SLICE OVERFLOW DSP A T1


58 DSPA: TIME-SLICE OVERFLOW DSP A T2
59 DSPA: TIME-SLICE OVERFLOW DSP A T3
60 DSPA: TIME-SLICE OVERFLOW DSP A T4
Description The processing of one time slice of the DSP-software did
not terminate within the allowed time.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B
Main circuit breaker
“drive shutdown” transition to “drive shutdown”
Possible reasons • processing time overload
• fault of DSP-card A (G019)
action to reset switch off / switch on – sequence TCU
action to repair • software correction (by SIEMENS)
• exchange DSP-card A (G019)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 50 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 70 DSPA: OVERCURRENT

Description Over current at the output of inverter A (phase L1, L2, L3)
Threshold 2499 A
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
Possible reasons • power circuit fault inverter A (e.g. short circuit)
• fault of inverter output current measuring device
action to reset Automatic reset of pulse-inhibit after 2 s, if over current
disappeared.
action to repair • repair power circuit inverter A
• repair/exchange faulty measuring device
SIEMENS-event code 81
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 51 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 71 DSPA: PARAMETER FAULT BRAKING


CHOPPER FREQUENCY
Description The braking chopper frequency is out of possible range.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit inhibit inverter A and B
Main circuit breaker
“drive shutdown” transition to “drive shutdown” until next power-up of TCU
Possible reasons • fault of DSP A (G019)
• fault of CPU (G011)
action to repair • exchange DSP A (G019)
• exchange CPU (G011)
SIEMENS-event code
Notes If the chopper frequency is set correctly in the software,
the fault should not occur. If the event shows up in the
memory nevertheless, it indicates a fault of the DSP- or
CPU-card.

event code and diagnosis message 72 DSPA: FAILURE VOLTAGE TRANSDUCER


U13 (T101)
Description Failure acquisition of motor transducer value U13
(transducer T101).
Software detection by DSP A (G019)
Protection reactions: Switchover to current modeling for flux.
Possible reasons fault of motor voltage measuring device
action to repair repair/exchange faulty motor voltage measuring device
SIEMENS-event code 41
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 52 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 73 DSPA: FAILURE VOLTAGE TRANSDUCER


U23 (T102)
Description Failure acquisition of motor transducer value U23
(transducer T102).
Software detection by DSP A (G019)
Protection reactions: Switchover to current modeling for flux.
Possible reasons Fault of motor voltage measuring device
action to repair Repair/exchange faulty motor voltage measuring device
SIEMENS-event code 41
Notes

event code and diagnosis message 74 DSPA: HSCX DATA FROM DSP B MISSING

Description Failure of high speed communication link between DSP A


(G019) and DSP B (G027).
Software detection by DSP A (G019)
Possible reasons • failure DSP B (G027)
• failure DSP A (G019)
• back plane wiring failure
action to repair Replace defective DSP-card or repair back plane wiring.
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 53 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 76 DSPA: SUM OF OUTPUT CURRENTS NOT
ZERO
Description The sum of the inverter phase currents exceeded the
allowed maximum.
Threshold 500 A
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
Possible reasons • power circuit fault inverter A
• fault of measuring device for inverter output currents
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair • repair power circuit inverter A
• repair/exchange faulty measuring device
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 54 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 77 DSPA: FAILURE V/F-CARD FOR DSP A
(L055)
Description Offset or amplification of a V/f-channel is out of the
admissible range.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit A and B
Possible reasons • failure V/f-card L055
• failure DSP-card G019
action to reset Automatic reset of inverter pulse inhibit, if offsets and
amplifications are in the permissible range for all channels
at the next calibration. The calibration will be performed
every 60 seconds.
action to repair • exchange V/f-card L055
• exchange DSP-card G019
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 55 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 78 DSPA: PULSE-PATTERN FAULT AT HIGH


FREQUENCY
Description
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons
action to reset
action to repair
SIEMENS-event code
Notes

event code and diagnosis message 79 DSPA: ACTIVE CURRENT CONTROLLER IN


LIMITATION
Description The slip frequency reference is at the stability limit for
more than 2 seconds.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons High torque request at low bus-voltage.
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 56 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 80 DSPA: ACTIVE CURRENT REFERENCE


VALUE IN LIMITATION
Description The active current component reference is at the limit
(determined by the admissible total current) for more than
2 seconds.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons High torque request at low bus-voltage.
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes

event code and diagnosis message 81 DSPA: CHOPPER CONTROLLER IN


LIMITATION
Description The chopper modulation degree is at its upper limit for
more than 8 seconds.
Software detection by DSP A (G019) / CPU (G011) [T4]
Protection reactions: No
Possible reasons retard chopper overload
action to repair to be corrected by SIEMENS
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 57 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 82 DSPA: PULSE-INHIBIT BY DSP A


(G019)
Description Pulse inhibit by DSP-software.
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
Possible reasons • calibration V/f-cards after Reset active
• DSP-software inhibit (by monitor) is set
• watchdog-supervision has triggered
SIEMENS-event code No
Notes

event code and diagnosis message 85 DSPA: UNBALANCE PROTECTION


INVERTER CURRENTS
Description The unbalance of the inverter phase currents exceeded the
threshold.
Threshold 250 A
Software detection by DSP A (G019)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
Possible reasons • open circuit between inverter and motor
• internal fault traction motor
• GTO switching failure (GTO does not turn on)
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair • repair power circuit
• exchange traction motor
• exchange defective Gate-Unit or power module
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 58 of 218
TRACTION DRIVES / SE&A

100+

event code and diagnosis message 100 DSPB: FAILURE DSP B (G027)

Description A failure of DSP B (G027) has been detected.


Software detection by CPU (G011)
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons failure DSP B (G027)
action to reset switch off / switch on – sequence TCU
action to repair replace defective DSP B (G027)
SIEMENS-event code No
Notes The power start-up sequence for the drive system will not
be performed. No operation is possible.

event code and diagnosis message 101 DSPB: START-UP FAILURE DSP B (G027)

Description A failure during the start-up sequence of DSP B (G027)


has been detected.
Software detection by CPU (G011) during start-up routine G9
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons failure DSP B (G027)
action to reset switch off / switch on – sequence TCU
action to repair replace defective DSP B (G027)
SIEMENS-event code No
Notes The power start-up sequence for the drive system will not
be performed. No operation is possible.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 59 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 102 DSPB: BUSY-MONITORING DSP B (G027)

Description A failure of DSP B has been detected by the busy-


monitoring.
Software detection by CPU (G011) [T4]
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons failure DSP A (G019)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair replace defective DSP B (G027)
SIEMENS-event code 111
Notes

event code and diagnosis message 103 DSPB: SOFTWARE-TRACO DSP B (G027)
HAS TRIGGERED
Description Message for the commissioning personnel, event does not
indicate a failure.
Software detection by DSP B (G019) / CPU (G011)
Notes

event code and diagnosis message 104 DSPB: SOFTWARE-TRACO DSP B (G019)
FULL
Description All partitions of the DSP software transient recorder are
occupied. Message for the commissioning personnel,
event does not indicate a failure.
Software detection by DSP B (G019) / CPU (G011)
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 60 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 106 DSPB: INITIALIZATION FAULT DSP B
(G027)
Description Start-up check routines of DSP-software detected a fault.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • inhibit inverter A and B in propel
• inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons failure DSP-card B (G027)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair replace defective DSP-card (G027)
SIEMENS-event code 111
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 61 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 107 DSPB: TIME-SLICE OVERFLOW DSP B T1
108 DSPB: TIME-SLICE OVERFLOW DSP B T2
109 DSPB: TIME-SLICE OVERFLOW DSP B T3
110 DSPB: TIME-SLICE OVERFLOW DSP B T4
Description The processing of one time slice of the DSP-software did
not terminate within the allowed time.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons • processing time overload
• fault of DSP-card B (G027)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair • software correction (by SIEMENS)
• exchange DSP-card B (G027)
SIEMENS-event code 111
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 62 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 120 DSPB: OVERCURRENT

Description Over current at the output of inverter B (phase L1, L2, L3)
Threshold 2499 A
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • power circuit fault inverter B (e.g. short circuit)
• fault of inverter output current measuring device
action to reset Automatic reset of pulse-inhibit after 2 s, if over current
disappeared.
action to repair • repair power circuit inverter B
• repair/exchange faulty measuring device
SIEMENS-event code 81
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 63 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 121 DSPB: PARAMETER FAULT BRAKING
CHOPPER FREQUENCY
Description Braking chopper frequency is out of possible range.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B
Possible reasons • fault of DSP B (G027)
• fault of CPU (G011)
action to reset • limp mode for propel is possible after reset by driver at
standstill
• switch off / switch on – sequence TCU
action to repair • exchange DSP B (G027)
• exchange CPU (G011)
SIEMENS-event code 111
Notes If the chopper frequency is set correctly in the software,
the fault should not occur. If the event shows up in the
memory nevertheless, it indicates a fault of the DSP- or
CPU-card.

event code and diagnosis message 122 DSPB: FAILURE VOLTAGE TRANSDUCER
U13 (T201)
Description Failure acquisition of motor transducer value U13
(transducer T201).
Software detection by DSP B (G027)
Protection reactions: Switchover to current modeling for flux.
Possible reasons fault of motor voltage measuring device
action to repair repair/exchange faulty motor voltage measuring device
SIEMENS-event code 41
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 64 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 123 DSPA: FAILURE VOLTAGE TRANSDUCER
U23 (T202)
Description Failure acquisition of motor transducer value U23
(transducer T202).
Software detection by DSP B (G027)
Protection reactions: Switchover to current modeling for flux.
Possible reasons Fault of motor voltage measuring device
action to repair Repair/exchange faulty motor voltage measuring device
SIEMENS-event code 41
Notes

event code and diagnosis message 124 DSPB: HSCX DATA FROM DSP B MISSING

Description Failure of high speed communication link between DSP A


(G019) and DSP B (G027).
Software detection by DSP B (G027)
Possible reasons • failure DSP B (G027)
• failure DSP A (G019)
• back plane wiring failure
action to repair Replace defective DSP-card or repair back plane wiring.
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 65 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 126 DSPB: SUM OF OUTPUT CURRENTS NOT
ZERO
Description The sum of the inverter phase currents exceeded the
allowed maximum.
Threshold 500 A
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • power circuit fault inverter B
• fault of measuring device for inverter output currents
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair • repair power circuit inverter B
• repair/exchange faulty measuring device
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 66 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 127 DSPB: FAILURE V/F-CARD FOR DSP B
(L063)
Description Offset or amplification of a V/f-channel is out of the
admissible range.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • failure V/f-card L063
• failure DSP-card G027
action to reset Automatic reset of inverter pulse inhibit, if offsets and
amplifications are in the permissible range for all channels
at the next calibration. The calibration will be performed
every 60 seconds.
action to repair • exchange V/f-card L063
• exchange DSP-card G027
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 67 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 128 DSPB: PULSE-PATTERN FAULT AT HIGH
FREQUENCY
Description
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons
action to reset
action to repair
SIEMENS-event code
Notes

event code and diagnosis message 129 DSPB: ACTIVE CURRENT CONTROLLER IN
LIMITATION
Description The slip frequency reference is at the stability limit for
more than 2 seconds.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons High torque request at low bus-voltage.
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 68 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 130 DSPB: ACTIVE CURRENT REFERENCE
VALUE IN LIMITATION
Description The active current component reference is at the limit
(determined by the admissible total current) for more than
2 seconds.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit “soft” inhibit inverter A and B
Possible reasons High torque request at low bus-voltage.
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes

event code and diagnosis message 131 DSPB: BRAKING CHOPPER CONTROLLER
IN LIMITATION
Description
Software detection by DSP B (G027)
Protection reactions:
Possible reasons
action to reset
action to repair Fault of bus-voltage control (to be corrected by
SIEMENS)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 69 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 132 DSPB: PULSE-INHIBIT BY DSP B


(G027)
Description Pulse inhibit by DSP-software.
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • calibration V/f-cards after Reset active
• DSP-software inhibit (by monitor) is set
• watchdog-supervision has triggered
SIEMENS-event code No
Notes

event code and diagnosis message 135 DSPB: UNBALANCE PROTECTION


INVERTER CURRENTS
Description The unbalance of the inverter phase currents exceeded the
threshold.
Threshold 250 A
Software detection by DSP B (G027)
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
Possible reasons • open circuit between inverter and motor
• internal fault traction motor
• GTO switching failure (GTO does not turn on)
action to reset Automatic reset of pulse-inhibit after 2 s, if cause
disappeared.
action to repair • repair power circuit
• exchange traction motor
• exchange defective Gate-Unit or power module
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 70 of 218
TRACTION DRIVES / SE&A

350+

event code and diagnosis message 350 IO: OVERVOLTAGE DC-LINK, 1. LEVEL
(PIN X2.F2)
Description Over voltage DC-link (transducer U105)
Threshold 3000 / 2900 V (hysteresis)
Hardware detection by IO-card (G035), comparator 1
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit A and B for 2 s
Possible reasons • bus voltage regulation disturbance
• fault of bus voltage measuring device
action to repair repair faulty measuring device
SIEMENS-event code 81
Notes

event code and diagnosis message 351 IO: OVERVOLTAGE DC-LINK, 2. LEVEL
(PIN X2.D2)
Description Over voltage DC-link (transducer U105)
Threshold 3400 / 500 V (hysteresis)
Hardware detection by IO-card (G035), comparator 2
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • secondary fault (e.g. in case of chopper failure)
• fault of bus voltage measuring device
action to reset reset by driver at standstill
action to repair • eliminate original fault
• repair faulty measuring device
SIEMENS-event code

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 71 of 218
TRACTION DRIVES / SE&A
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 72 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 353 IO: OVERCURRENT BRAKING CHOPPER
A(PIN X2.D4)
354 IO: OVERCURRENT BRAKING CHOPPER
B(PIN X2.F6)
Description chopper over current (transducer U104 or U204)
Threshold 2000 A
Hardware detection by IO-card (G035), comparator 4 (A), comparator 5 (B)
Protection reactions: No
Possible reasons • short circuit
• grid resistor fault
• fault of chopper current measuring device
action to repair • eliminate short circuit
• repair grid resistor fault
• repair faulty measuring device
SIEMENS-event code 112,113
Notes

event code and diagnosis message 355 IO: OVERCURRENT DC-LINK (PIN
X2.D6)
Description
Threshold
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 73 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 356 IO: OVERVOLTAGE TROLLEY (PIN
X2.F08)
Description
Threshold
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes

event code and diagnosis message 358 IO: OVERCURRENT TROLLEY (PIN
X2.B8)
Description
Threshold
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 74 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 360 IO: TEST-VOLTAGE IO-CARD NOT ZERO

Description The voltage source for the comparator test is not zero in
normal operation.
Threshold 0V
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons fault of IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 75 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 361 IO: CLOCK-SUPERVISION ABIN1


362 IO: CLOCK-SUPERVISION ABIN2
384 IO: CLOCK-SUPERVISION ABIN3
387 IO: CLOCK-SUPERVISION ABIN4
388 IO: CLOCK-SUPERVISION ABIN5
Description PCB-clock failure binary output contactor drive.
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons clock failure
action to reset switch off / switch on – sequence TCU
action to repair exchange faulty output contactor drive card
ABIN1 : C003 (2B) / G119 (2A)
ABIN2 : C011 (2B) / G127 (2A)
ABIN3 : C019 (2B) / G151 (2A)
ABIN4 : C027
ABIN5 : C035
SIEMENS-event code
Notes 2B: TCU 6FH4272-2B
2A: TCU 6FH4272-2A

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 76 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 363 IO: TCU PLUG-MONITORING

Description TCU front plug or PCB is loose or missing.


Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • TCU front plug is loose or missing
• TCU PCB is loose or missing
action to repair • fasten TCU front plugs correctly
• fasten TCU PCBs correctly
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 77 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 367 IO: PROCESS SUPERVISION CPU (G011)
381 IO: PROCESS SUPERVISION DSP A
(G019)
382 IO: PROCESS SUPERVISION DSP B
(G027
Description The process clocks of processor cards are supervised by
watchdog timers.
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • process clock failure CPU (367)
• process clock failure DSP A (381)
• process clock failure DSP B (382)
action to reset switch off / switch on – sequence TCU
action to repair • exchange CPU-card (G011)
• exchange DSP A (G019)
• exchange DSP B (G027)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 78 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 368 CPU-RESET

Description CPU Reset performed by monitor or pushbutton on CPU-


card (G011).
Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
SIEMENS-event code
Notes The code 368 normally does not show up in case of a
reset, as the diagnosis routine will not be processed any
more.

event code and diagnosis message 370 IO: SUPERVISION BUS-CLOCK IO

Description PCB-clock failure CPU.


Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons PCB-clock failure CPU
action to reset switch off / switch on – sequence TCU
action to repair exchange CPU-card (G011)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 79 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 371 IO: SUPERVISION PCB-CLOCK IO

Description PCB-clock failure IO-card.


Hardware detection by IO-card (G035)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons PCB-clock failure IO-card
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes

event code and diagnosis message 372 IO: INCORRECT VERSION FPGA IO
(G035)
Description The revision level of the IO-card FPGA is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong IO-card FPGA in use
action to repair exchange IO-card FPGA or IO-card (G035)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 80 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 373 IO: INCORRECT APPLICATION VERSION
FPGA IO
Description The application version of the IO-card FPGA is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong IO-card FPGA in use
action to repair exchange IO-card FPGA or IO-card (G035)
SIEMENS-event code
Notes

event code and diagnosis message 375 IO: FAILURE ADC IO (G035)

Description The conversion time for a AD-converter of the IO-card


was exceeded.
Software detection by CPU (G011) [T1/T3/T6]
Protection reactions:
Excitation permanent inhibit 1)
Drive shutdown transition to drive shutdown 1)
Possible reasons AD-converter failure IO-card (G035)
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes 1) This fault reaction takes only place, if the ADC reading
the DC-bus voltage is affected. If an AD-converter
exceeded the maximum conversion time, the software
value will be set to a default value (normally “0”). This
may lead to secondary faults, e.g. ground fault detection, if
the ground voltage cannot be read any more.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 81 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 376 IO: INCORRECT VERSION IO-CARD
(G035)
Description The version of the IO-card is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong IO-card in use
action to repair exchange IO-card (G035)
SIEMENS-event code
Notes

event code and diagnosis message 397 IO: HARDWARE COMPARATOR FAULT

Description A hardware comparator of the IO-card failed during the


comparator test.
Software detection by CPU (G011) during TCU-self test routine (after power-up)
Protection reactions: If all three hardware comparators for the bus-voltage
(transducer U105) failed, the start-up sequence for the
power-circuit will not be performed. In this case no
operation will be possible.
Possible reasons IO hardware comparator fault
action to reset switch off / switch on – sequence TCU
action to repair exchange IO-card (G035)
SIEMENS-event code 41
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 82 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 398 IO: FAILURE ADC IO FOR TCU
TEMPERATURE (G035)
Description The conversion time for the IO-temperature AD-converter
was exceeded.
Software detection by CPU (G011) [T8]
Protection reactions: No
Possible reasons AD-converter failure IO-temperature
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
Notes

event code and diagnosis message 399 IO: TCU TEMPERATURE OUT OF
MEANINGFUL RANGE
Description The TCU temperature or its gradient are out of reasonable
ranges.
Software detection by CPU (G011) [T8]
Protection reactions: No
Possible reasons PCB fault IO-card (035)
action to reset switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 83 of 218
TRACTION DRIVES / SE&A

603+

event code and diagnosis message 603 TCU POWER SUPPLY FAILURE 24 V FOR
PULSE AMPLIFIER
Description Under voltage power supply for pulse amplifiers and IPM
electronic card has been detected
Hardware detection by power-start-up unit (G163) / UWS-card A (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • DC/DC-converter failure C045
• failure power start-up unit (G163)
• failure pulse amplifier card (2B: L111, L119; 2A:
L095, L103)
• failure IPM electronic card (external from TCU)
• short-circuit (especially wiring for the 24V-supply of
the IPM electronic card)
action to reset switch off / switch on – sequence TCU
action to repair • replace defective DC/DC-converter C045
• replace defective power start-up unit (G163)
• replace defective pulse amplifier card (2B: L111, L119;
2A: L095, L103)
• replace defective IPM electronic card (external from
TCU)
• repair defective wiring
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 84 of 218
TRACTION DRIVES / SE&A

620 UWSA: GTO SWITCHING FAILURE A101-1


event code and diagnosis message 621 UWSA: GTO SWITCHING FAILURE A101-2
622 UWSA: GTO SWITCHING FAILURE A102-1
623 UWSA: GTO SWITCHING FAILURE A102-2
624 UWSA: GTO SWITCHING FAILURE A103-1
625 UWSA: GTO SWITCHING FAILURE A103-2
626 UWSA: GTO SWITCHING FAILURE A104
Description Inconsistency between GTO command and feedback
status.
Hardware detection by UWS-card A (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • power module fault
• Gate Unit fault
• wiring fault (GTO commands and feedback signals)
• pulse-amplifier-card fault (2B: L111, 2A: L095)
• UWS-card fault (G071)
action to reset Fault reset by driver at standstill.
action to repair • exchange faulty power module
• exchange faulty Gate Unit
• repair faulty wiring (GTO commands and feedback
signals)
• exchange faulty pulse-amplifier-card (2B: L111, 2A:
L095)
• exchange faulty UWS-card (G071)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 85 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 642 UWSA: OVERCURRENT INV A L1


643 UWSA: OVERCURRENT INV A L2
644 UWSA: OVERCURRENT INV A L3
Description Over current at the output of inverter A.
Threshold 2451 / 1600...2000 A (hysteresis)
Hardware detection by UWS-card A (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • power circuit fault (e.g. short circuit)
• fault of inverter output current measuring device
action to reset Fault reset by driver at standstill.
action to repair • repair power circuit fault
• exchange faulty current measuring device
SIEMENS-event code
Notes phase L1: transducer U101
phase L2: transducer U102
phase L3: transducer U103

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 86 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 645 UWSA: OVERVOLTAGE DC-LINK (GW5)

Description Over voltage DC-link (transducer U105)


Threshold 3600 / 3000 V (hysteresis)
Hardware detection by UWS-card A (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar commanded by hardware circuit
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons • secondary fault (e.g. in case of chopper failure)
• fault of bus voltage measuring device
action to reset Fault reset by driver at standstill.
action to repair • repair power circuit fault
• exchange faulty voltage measuring device
SIEMENS-event code
Notes

event code and diagnosis message 646 UWSA: SUPERVISION BUS-CLOCK UWSA

Description PCB-clock failure CPU.


Hardware detection by UWS-card A (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons PCB-clock failure CPU
action to reset switch off / switch on – sequence TCU
action to repair exchange CPU-card (G011)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 87 of 218
TRACTION DRIVES / SE&A

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 88 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 647 UWSA: SUPERVISION PCB-CLOCK UWS A
(G071)
Description PCB-clock failure UWS-card A (G071).
Hardware detection by UWS-card (G071)
Protection reactions:
Inverter GTO pulse inhibit immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation inhibit by hardware circuit (totallock)
Main circuit breaker inhibit by hardware circuit (totallock)
Possible reasons PCB-clock failure UWS-card A
action to reset switch off / switch on – sequence TCU
action to repair exchange UWS-card A (G071)
SIEMENS-event code
Notes

event code and diagnosis message 660 UWSA: INCORRECT VERSION FPGA UWSA
(G071)
Description The revision level of the UWS-card FPGA is incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong UWS-card FPGA in use
action to repair exchange UWS-card FPGA or UWS-card (G071)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 89 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 661 UWSA: INCORRECT APPLICATION


VERSION FPGA UWS A (G071)
Description The application version of the UWS-card FPGA is
incorrect.
Software detection by CPU (G011) during start-up routine P2
Protection reactions:
Inverter GTO pulse inhibit totallock will not be removed
Excitation totallock will not be removed
Main circuit breaker totallock will not be removed
Possible reasons wrong UWS-card FPGA in use
Action to repair exchange UWS-card FPGA or UWS-card (G071)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 90 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 662 UWSA: SUPERVISION SWITCHING


FREQUENCY
Description The switching frequency of inverter A exceeded one of the
limits.
Hardware/software detection by micro controller UWS A (G071)
Thresholds 6 pulses in 6 ms
9 pulses in 12 ms
18 pulses in 42 ms
70 pulses in 192 ms (80 for motor magnetization)
Protection reactions:
Inverter GTO pulse inhibit Inverter A and B
Possible reasons • several consecutive GTO-switch offs due to high peak-
currents (compare code 664)
• control disturbance due to faulty measured values
• fault of trigger equipment
• fault of UWS-card A
action to reset Automatic reset of inverter inhibit after 2 s.
action to repair • eliminate cause of peak-current-supervision (compare
code 664)
• exchange faulty measuring equipment
• exchange DSP-card A (G019)
• exchange UWS-card A (G071)
SIEMENS-event code 81
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 91 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 663 UWSA: FAILURE MICROCONTROLLER UWS
A (G071)
Description The micro controller of the UWS-card is not ready for
operation.
Hardware/software detection by CPU (G011) [T1]
Protection reactions: No
Possible reasons Micro controller failure.
action to reset Switch off / switch on – sequence TCU
action to repair Exchange UWS-card A (G071)
SIEMENS-event code 41
Notes

event code and diagnosis message 664 UWSA: PEAK CURRENT PROTECTION
INVERTER ACTIVE
Description One of the inverter output currents exceeded the
permissible level.
Threshold 1900...2300 A / 1000...1600 A (hysteresis, depending on
stator frequency)
Hardware detection by UWS A (G071)
Protection reactions: • affected GTO will be switched off
• immediate torque reduction to 80% of actual level for 3
seconds
Possible reasons • control disturbances caused by road conditions
• power circuit fault (e.g. motor internal fault)
• fault of inverter current measuring device
action to repair • repair power circuit fault
• exchange faulty measuring device
SIEMENS-event code
Notes Sporadic events are admissible and do not require
corrective action.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 92 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 665 UWSA: FAILURE ADC UWS A (G071)

Description The conversion time for an AD-converter of the UWS-


card A was exceeded.
Software detection by CPU (G011) [T3]
Protection reactions: No
Possible reasons AD-converter failure.
action to reset Switch off / switch on - sequence TCU
action to repair Exchange UWS-card A (G071)
SIEMENS-event code 41
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 93 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 666 UWSA: PARAMETER OR HARDWARE FAULT
UWS A (G071)
Description Faulty UWS-card or fault of software parameter for UWS-
functions.
Software detection by CPU (G011) [T8]
Protection reactions:
Inverter GTO pulse inhibit Permanent inhibit inverter A
Possible reasons • faulty UWS-card (G071)
• software parameter fault
action to reset • limp mode for propel is possible after fault reset by
driver at standstill (limp mode for retard is enabled
automatically)
• switch off / switch on - sequence TCU
action to repair • exchange UWS-card A (G071)
• correct software parameter fault (only SIEMENS)
SIEMENS-event code 111
Notes

event code and diagnosis message 667 UWSA: PEAK CURRENT PROT. DURING
INVERTER-START-PHASE
Description A peak current protection (code 664) occurs during the
start-phase of the inverter.
Software detection by CPU (G011) [T2]
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
• permanent inhibit inverter A (BRAM)
Possible reasons Power circuit fault (e.g. short circuit)
action to reset Limp mode for propel is possible after fault reset by driver
at standstill
action to repair Repair power circuit fault
SIEMENS-event code 111
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 94 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 668 UWSA: PEAK VOLTAGE PROTECTION DC-
LINK ACTIVE
Description
Software detection by CPU (G011) [T2]
Protection reactions:
Inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
Possible reasons Power circuit fault (e.g. short circuit)
action to reset
action to repair Repair power circuit fault
SIEMENS-event code
Notes

event code and diagnosis message 669 UWSA: PEAK CURRENT COUNTER
PROTECTION INVERTER
Description The number of peak current protections within a time
frame exceeded the permissible limit.
Software detection by CPU (G011) [T1]
Threshold 6 peak current protections within 192 ms
Protection reactions:
Inverter GTO pulse inhibit Immediate inhibit inverter A and B
Possible reasons See code 664
action to reset Limp mode is possible after fault reset by driver at
standstill
action to repair See code 664
SIEMENS-event code 111
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 95 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 697 UWSA: HARDWARE COMPARATOR FAULT

Description A hardware comparator of the UWS-card failed during the


comparator test.
Software detection by CPU (G011) during TCU-self test routine (after power-up)
Protection reactions: • If one of the comparators for the inverter output
currents failed, inverter A will be inhibit permanently
• If all three hardware comparators for the bus-voltage
(transducer U105) failed, the start-up sequence for the
power-circuit will not be performed. In this case no
operation will be possible.
Possible reasons UWS hardware comparator fault
action to reset • limp mode for propel is possible after fault reset by
driver at standstill (limp mode for retard is enabled
automatically)
• switch off / switch on - sequence TCU
action to repair Exchange UWS-card A (G071)
SIEMENS-event code 41, 111
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 96 of 218
TRACTION DRIVES / SE&A

703+

event code and diagnosis message 703 UWSB: IPM CURRENT DETECTION (PIN
X1.D12)
Description
Hardware detection by UWS-card B (G079)
Protection reactions:
Inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation Inhibit by hardware circuit (totallock)
Main circuit breaker Inhibit by hardware circuit (totallock)
Possible reasons • fault of IPM-firing electronic card
• fault of pulse amplifier card B (2B: L119, 2A: L103)
• fault of UWS-card B (G079)
action to reset Automatic reset of fault reactions as soon as IPM feedback
signal goes low.
action to repair • exchange BOD, if firing was unjustified
• exchange IPM-firing electronic card
• exchange faulty pulse amplifier card (2B: L119, 2A:
L103)
• exchange faulty UWS-card B (G079)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 97 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 715 UWSB: IPM FEEDBACK SIGNAL

Description The IPM feedback signal indicates an IPM firing not


caused by the TCU.
Hardware detection by UWS-card B (G079)
Protection reactions:
Inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
Excitation Inhibit by hardware circuit (totallock)
Main circuit breaker Inhibit by hardware circuit (totallock)
Possible reasons • IPM fired by BOD
• fault of IPM-firing electronic card
• fault of pulse amplifier card B (2B: L119, 2A: L103)
• fault of UWS-card B (G079)
action to reset Automatic reset of fault reactions as soon as IPM feedback
signal goes low.
action to repair • exchange BOD, if firing was unjustified
• exchange IPM-firing electronic card
• exchange faulty pulse amplifier card (2B: L119, 2A:
L103)
• exchange faulty UWS-card B (G079)
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 98 of 218
TRACTION DRIVES / SE&A

720 UWSB: GTO SWITCHING FAILURE A201-1


event code and diagnosis message 721 UWSB: GTO SWITCHING FAILURE A201-2
722 UWSB: GTO SWITCHING FAILURE A202-1
723 UWSB: GTO SWITCHING FAILURE A202-2
724 UWSB: GTO SWITCHING FAILURE A203-1
725 UWSB: GTO SWITCHING FAILURE A203-2
726 UWSB: GTO SWITCHING FAILURE A204
Description Inconsistency between GTO command and feedback
status.
Hardware detection by UWS-card B (G079)
Protection reactions:
Inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
Crowbar Commanded by hardware circuit
Excitation Inhibit by hardware circuit (totallock)
Main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons • power module fault
• Gate Unit fault
• wiring fault (GTO commands and feedback signals)
• pulse-amplifier-card fault (2B: L119, 2A: L103)
• UWS-card fault (G079)
action to reset Fault reset by driver at standstill.
action to repair • exchange faulty power module
• exchange faulty Gate Unit
• repair faulty wiring (GTO commands and feedback
signals)
• exchange faulty pulse-amplifier-card (2B: L119, 2A:
L103)
• exchange faulty UWS-card (G079)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 99 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 742 UWSB: OVERCURRENT INV B L1


743 UWSB: OVERCURRENT INV B L2
744 UWSB: OVERCURRENT INV B L3
description Over current at the output of inverter B.
threshold 2451 / 1600...2000 A (hysteresis)
hardware detection by UWS-card B (G079)
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
crowbar Commanded by hardware circuit
excitation Inhibit by hardware circuit (totallock)
main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons • power circuit fault (e.g. short circuit)
• fault of inverter output current measuring device
action to reset Fault reset by driver at standstill.
action to repair • repair power circuit fault
• exchange faulty current measuring device
SIEMENS-event code
notes Phase L1: transducer U201
phase L2: transducer U202
phase L3: transducer U203

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 100 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 745 UWSB: OVERVOLTAGE DC-LINK (GW5)

description Over voltage DC-link (transducer U105)


threshold 3600 / 3000 V (hysteresis)
hardware detection by UWS-card B (G079)
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
crowbar Commanded by hardware circuit
excitation Inhibit by hardware circuit (totallock)
main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons • secondary fault (e.g. in case of chopper failure)
• fault of bus voltage measuring device
action to reset Fault reset by driver at standstill.
action to repair • repair power circuit fault
• exchange faulty voltage measuring device
SIEMENS-event code
notes

event code and diagnosis message 746 UWSB: SUPERVISION BUS-CLOCK UWSB

description PCB-clock failure CPU.


hardware detection by UWS-card B (G079)
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
excitation Inhibit by hardware circuit (totallock)
main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons PCB-clock failure CPU
action to reset Switch off / switch on - sequence TCU
action to repair Exchange CPU-card (G011)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 101 of 218
TRACTION DRIVES / SE&A

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 102 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 747 UWSB: SUPERVISION PCB-CLOCK UWS B
(G079)
description PCB-clock failure UWS-card B (G079).
hardware detection by UWS-card (G079)
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
excitation Inhibit by hardware circuit (totallock)
main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons PCB-clock failure UWS-card B
action to reset Switch off / switch on – sequence TCU
action to repair Exchange UWS-card B (G079)
SIEMENS-event code
notes

event code and diagnosis message 760 UWSB: INCORRECT VERSION FPGA UWSB
(G079)
description The revision level of the UWS-card FPGA is incorrect.
software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong UWS-card FPGA in use
action to repair Exchange UWS-card FPGA or UWS-card (G079)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 103 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 761 UWSB: INCORRECT APPLICATION


VERSION FPGA UWS B (G079)
description The application version of the UWS-card FPGA is
incorrect.
software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
possible reasons Wrong UWS-card FPGA in use
action to repair Exchange UWS-card FPGA or UWS-card (G079)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 104 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 762 UWSB: SUPERVISION SWITCHING


FREQUENCY
description The switching frequency of inverter B exceeded one of the
limits.
hardware/software detection by Micro controller UWS B (G079)
thresholds 5 pulses in 6 ms
9 pulses in 12 ms
18 pulses in 42 ms
70 pulses in 192 ms (80 for motor magnetization)
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B
possible reasons • several consecutive GTO-switch offs due to high peak-
currents (compare code 764)
• control disturbance due to faulty measured values
• fault of trigger equipment
• fault of UWS-card B
action to reset Automatic reset of inverter inhibit after 2 s.
action to repair • eliminate cause of peak-current-supervision (compare
code 764)
• exchange faulty measuring equipment
• exchange DSP-card B (G027)
• exchange UWS-card B (G079)
SIEMENS-event code 81
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 105 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 763 UWSB: FAILURE MICROCONTROLLER UWS
B (G079)
description The micro controller of the UWS-card is not ready for
operation.
hardware/software detection by CPU (G011) [T1]
protection reactions: No
possible reasons Micro controller failure.
action to reset Switch off / switch on - sequence TCU
action to repair Exchange UWS-card B (G079)
SIEMENS-event code 41
notes

event code and diagnosis message 764 UWSA: PEAK CURRENT PROTECTION
INVERTER ACTIVE
description One of the inverter output currents exceeded the
permissible level.
threshold 1900...2300 A / 1000...1600 A (hysteresis, depending on
stator frequency)
hardware detection by UWS B (G079)
protection reactions: • affected GTO will be switched off
• immediate torque reduction to 80% of actual level for 3
seconds
possible reasons • control disturbances caused by road conditions
• power circuit fault (e.g. motor internal fault)
• fault of inverter current measuring device
action to repair • repair power circuit fault
• exchange faulty measuring device
SIEMENS-event code
notes Sporadic events are admissible and do not require
corrective action.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 106 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 765 UWSB: FAILURE ADC UWS B (G079)

description The conversion time for a AD-converter of the UWS-card


B was exceeded.
software detection by CPU (G011) [T3]
protection reactions: No
possible reasons AD-converter failure.
action to reset Switch off / switch on - sequence TCU
action to repair Exchange UWS-card B (G079)
SIEMENS-event code 41
notes

event code and diagnosis message 766 UWSB: PARAMETER OR HARDWARE FAULT
UWS B (G079)
description Faulty UWS-card or fault of software parameter for UWS-
functions.
software detection by CPU (G011) [T8]
protection reactions:
inverter GTO pulse inhibit Permanent inhibit inverter B
possible reasons • faulty UWS-card (G079)
• software parameter fault
action to reset • limp mode for propel is possible after fault reset by
driver at standstill (limp mode for retard is enabled
automatically)
• switch off / switch on - sequence TCU
action to repair • exchange UWS-card B (G079)
• correct software parameter fault (only SIEMENS)
SIEMENS-event code 111
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 107 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 767 UWSB: PEAK CURRENT PROT. DURING
INVERTER-START-PHASE
description A peak current protection (code 764) occurs during the
start-phase of the inverter.
software detection by CPU (G011) [T2]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
• permanent inhibit inverter B (BRAM)
possible reasons Power circuit fault (e.g. short circuit)
action to reset Limp mode for propel is possible after fault reset by driver
at standstill
action to repair Repair power circuit fault
SIEMENS-event code 111
notes

event code and diagnosis message 768 UWSB: PEAK VOLTAGE PRTECTION DC-
LINK ACTIVE
description
software detection by CPU (G011) [T2]
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B in propel
possible reasons Power circuit fault (e.g. short circuit)
action to reset
action to repair Repair power circuit fault
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 108 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 769 UWSB: PEAK CURRENT COUNTER
PROTECTION INVERTER
description The number of peak current protections within a time
frame exceeded the permissible limit.
software detection by CPU (G011) [T1]
threshold 6 peak current protections within 192 ms
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B
possible reasons See code 764
action to reset Limp mode is possible after fault reset by driver at
standstill
action to repair See code 764
SIEMENS-event code 111
notes

event code and diagnosis message 797 UWSB: HARDWARE COMPARATOR FAULT

description A hardware comparator of the UWS-card failed during the


comparator test.
software detection by CPU (G011) during TCU-self test routine (after power-up)
protection reactions: • If one of the comparators for the inverter output
currents failed, inverter B will be inhibit permanently.
• If all three hardware comparators for the bus-voltage
(transducer U105) failed, the start-up sequence for the
power-circuit will not be performed. In this case no
operation will be possible.
possible reasons UWS hardware comparator fault
action to reset • limp mode for propel is possible after fault reset by
driver at standstill (limp mode for retard is enabled
automatically)
• switch off / switch on - sequence TCU
action to repair Exchange UWS-card B (G079)
SIEMENS-event code 41, 111
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 109 of 218
TRACTION DRIVES / SE&A

800+

event code and diagnosis message 800 BUS2: SERIAL INTERFACE DATA
RECEPTION FAILURE
description The TCU did not receive a valid serial interface telegram
for more than 1 s.
software detection by CPU (G011) [T6]
protection reactions: The cruise control will be switched off, if the cruise
control commands are transmitted via serial interface.
possible reasons • fault/failure of transmitting device
• fault of serial interface card (G063)
• fault of serial interface wiring
action to reset Switch off / switch on – sequence control power
action to repair • repair or exchange transmitting device
• exchange serial interface card (G063)
• repair serial interface wiring
SIEMENS-event code 23
notes

event code and diagnosis message 819 BUS2: SERIAL INTERFACE CARD
FAILURE (G063)
description Fault/failure of serial interface card (G063)
software detection by CPU (G011) [T6]
protection reactions: The cruise control will be switched off, if the cruise
control commands are transmitted via serial interface.
possible reasons • fault/failure of serial interface card (G063)
action to reset Switch off / switch on – sequence TCU
action to repair • exchange serial interface card (G063)
SIEMENS-event code No transmission of event code possible any more.
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 110 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 850 TR: TRACO 1 HAS TRIGGERED

description The transient recorder A (G003) stored data due to an


active trigger signal.
software detection by CPU (G011) [T8]
protection reactions: No
notes Message for commissioning/service personnel.

event code and diagnosis message 851 TR: TRACO 1 IS FULL

description The transient recorder A (G003) memory is fully


occupied.
software detection by CPU (G011) [T8]
protection reactions: No
notes Message for commissioning/service personnel.

event code and diagnosis message 852 TR: TRACO 2 HAS TRIGGERED

description The transient recorder A (G043) stored data due to an


active trigger signal.
software detection by CPU (G011) [T8]
protection reactions: No
notes Message for commissioning/service personnel.

event code and diagnosis message 853 TR: TRACO 2 IS FULL

description The transient recorder A (G043) memory is fully


occupied.
software detection by CPU (G011) [T8]
protection reactions: No
notes Message for commissioning/service personnel.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 111 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 871 ETM: OPEN CIRCUIT PT100 ETM1
(L131)
description The TCU performs two plausibility checks for
temperatures read by the ETM-card. The value and its
gradient must be in reasonable ranges, otherwise an open
circuit is suspected.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • failure PT100
• fault of PT100 wiring
• fault of ETM-card 1 (L131)
action to repair • exchange PT100
• repair PT100 wiring
• exchange ETM-card 1 (L131)
SIEMENS-event code 41
notes If the TCU detects an open circuit, the last valid temperature
value will be frozen. If a valid temperature value was not yet
read, the temperature will be set to a default value (0°C).

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 112 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 872 ETM: OPEN CIRCUIT PT100 ETM2
(L139)
description The TCU performs two plausibility checks for
temperatures read by the ETM-card. The value and its
gradient must be in reasonable ranges, otherwise an open
circuit is suspected.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • failure PT100
• fault of PT100 wiring
• fault of ETM-card 2 (L139)
action to repair • exchange PT100
• repair PT100 wiring
• exchange ETM-card 2 (L139)
SIEMENS-event code 41
notes If the TCU detects an open circuit, the last valid temperature
value will be frozen. It a valid temperature value was not yet
read, the temperature will be set to a default value (0°C).

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 113 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 873 ETM: OPEN CIRCUIT PT100 ETM3
(L147)
description The TCU performs two plausibility checks for
temperatures read by the ETM-card. The value and its
gradient must be in reasonable ranges, otherwise an open
circuit is suspected.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • failure PT100
• fault of PT100 wiring
• fault of ETM-card 3 (L147)
action to repair • exchange PT100
• repair PT100 wiring
• exchange ETM-card 3 (L147)
SIEMENS-event code 41
notes If the TCU detects an open circuit, the last valid temperature
value will be frozen. It a valid temperature value was not yet
read, the temperature will be set to a default value (0°C).

event code and diagnosis message 876 ETM: FAILURE ADC IO (G035) FOR
TEMPERATURES OF ETM 1
description The conversion time for the AD-converter reading
temperatures from ETM1 was exceeded.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 114 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 877 ETM: FAILURE ADC IO (G035) FOR
TEMPERATURES OF ETM 2
description The conversion time for the AD-converter reading
temperatures from ETM2 was exceeded.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
notes

event code and diagnosis message 878 ETM: FAILURE ADC IO (G035) FOR
TEMPERATURES OF ETM 3
description The conversion time for the AD-converter reading
temperatures from ETM3 was exceeded.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on – sequence TCU
action to repair Exchange IO-card (G035)
SIEMENS-event code 41
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 115 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 890 INCORRECT PCB-VERSION EBIN 1

description The version of the EBIN-card 1 is incorrect.


software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong EBIN-card in use
action to repair Exchange EBIN-card 1 (2B: G111, 2A: G103)
SIEMENS-event code
notes

event code and diagnosis message 891 INCORRECT PCB-VERSION EBIN 2

description The version of the EBIN-card 2 is incorrect.


software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong EBIN-card in use
action to repair Exchange EBIN-card 1 (2B: G119, 2A: G111)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 116 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 892 INCORRECT PCB-VERSION EBIN 3

description The version of the EBIN-card 3 is incorrect.


software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong EBIN-card in use
action to repair Exchange EBIN-card 1 (2B: G127)
SIEMENS-event code
notes Fault code exists only for TCUs 6FH4272-2B !

910+

event code and diagnosis message 910 INCORRECT PCB-VERSION ABIN 1

description The version of the ABIN-card 1 is incorrect.


software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong ABIN-card in use
action to repair Exchange ABIN-card 1 (2A: G119)
SIEMENS-event code
notes Fault code exists only for TCUs 6FH4272-2A !

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 117 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 911 INCORRECT PCB-VERSION ABIN 2

description The version of the ABIN-card 2 is incorrect.


software detection by CPU (G011) during start-up routine P2
protection reactions:
inverter GTO pulse inhibit Totallock will not be removed
excitation Totallock will not be removed
main circuit breaker Totallock will not be removed
possible reasons Wrong ABIN-card in use
action to repair Exchange ABIN-card 1 (2A: G127)
SIEMENS-event code
notes Fault code exists only for TCUs 6FH4272-2A !

Event code and diagnosis message 921 DEFECTIVE OUTPUT TRANSISTOR ABIN 1
(C003)
Description The output transistor for the field regulator enable
command on card C003 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on - sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 1 (2B: C003)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 118 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 923 DEFECTIVE OUTPUT TRANSISTOR ABIN 3
(C019)
Description The output transistor for the field regulator enable
command on card C019 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on - sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 3 (2B: C019)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !

Event code and diagnosis message 924 DEFECTIVE OUTPUT TRANSISTOR ABIN 4
(C027)
Description The output transistor for the field regulator enable
command on card C019 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on - sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 4 (2B: C027)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 119 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 925 DEFECTIVE OUTPUT TRANSISTOR ABIN 5
(C035)
Description The output transistor for the field regulator enable
command on card C035 failed during the test at start-up.
Software detection by CPU (G011) [T6]
Protection reactions:
Excitation Permanent inhibit
Possible reasons • Failure of output transistor (short-circuited)
• Fault of wiring for field regulator enable command.
Action to reset Switch off / switch on – sequence TCU; permanent inhibit
of excitation will be reset if fault has been corrected.
Action to repair • Exchange ABIN-card 5 (2B: C035)
• Correct signal wiring
SIEMENS-event code
Notes The test of the output transistor is only effective for TCUs
4272-2B !

event code and diagnosis message 970 AIF: FAILURE ADC AIF (G087)

description The conversion time for one of the AD-converters of the


AIF-card was exceeded.
software detection by CPU (G011) [T7]
protection reactions: No
possible reasons AD-converter failure
action to reset Switch off / switch on - sequence TCU
action to repair Exchange AIF-card (G087)
SIEMENS-event code 41
notes The signal of a faulty AD-converter will be set to a default
value.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 120 of 218
TRACTION DRIVES / SE&A

1299+

event code and diagnosis message 1299 START-UP TEST: FEEDBACK ERROR
CONTACTOR K105
description The contactor K105 (module preheat contactor) is
commanded during the start-up test. If the feedbacks from
the contactor do not indicate that the contactor closed
during the test, code 1299 will be stored in the diagnosis
memory.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • fault of contactor K105
• fault of contactor wiring
action to repair • exchange contactor K105
• repair contactor wiring
SIEMENS-event code 41
notes If the contactor K105 does not work, module preheating is
impossible.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 121 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1311 HL: POWER-SUPPLY FAILURE GATE UNIT

description Status feedback error of all inverter Gate Units or status


feedback error from gate unit power supply.
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B by hardware circuits
(totallock)
crowbar Commanded by hardware circuit
excitation Inhibit by hardware circuit (totallock)
main circuit breaker Inhibit by hardware circuit (totallock)
possible reasons • failure gate unit power supply
• fault of gate unit power supply wiring (enable signal or
status feedback)
action to repair • exchange gate unit power supply
• repair faulty wiring
SIEMENS-event code 115
notes The protection reaction will be caused by the status
feedback error of the Gate Units (compare codes 620...626
or 720...726). If the gate unit power supply fails during the
start-up sequence, the start-up sequence will not be
terminated.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 122 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1315 HL: FAILURE IPM CURRENT DETECTION

description If the IPM (inverter protection module) is fired at a bus-


voltage of more than 300 V and the bus is discharged after
firing, the feedback from the IPM current transducer must
indicate the firing. If this feedback did not appear, the
message 1315 will be stored.
hardware/software detection by UWS B (G079) / CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit Inverter pulses are already inhibit due to IPM firing
drive shutdown Transition to drive shutdown (BRAM-buffered)
possible reasons • failure IPM current transducer
• fault of IPM current transducer wiring
• fault of IPM-module electronic card
• fault of IPM-module electronic card wiring
• fault of pulse amplifier card B (2B: L119, 2A: L103)
• fault of UWS-card B (G079)
action to reset “inhibits reset” by service personnel (by monitor)
action to repair • exchange IPM current transducer
• repair IPM current transducer wiring
• exchange IPM-module electronic card
• repair IPM-module electronic card wiring
• exchange pulse amplifier card B (2B: L119, 2A: L103)
• exchange UWS-card B (G079)
SIEMENS-event code 115
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 123 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1330 HL: GTO-PULSE-TEST: TEST STOPPED

description A GTO-pulse-test will be performed during the start-up


sequence of the drive and after the IPM was fired. The test
will be only performed, if certain conditions are fulfilled.
If one of these conditions is violated, message 1330 will
be stored.
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons • field regulator is not disabled
• DC-link contactor K104 is not open
• DC bus is not discharged
• gate unit power supply is not enabled
• test is not possible due to totallock
action to repair The fault, preventing the test performance has to be found
and eliminated. The diagnosis memory should be checked
for other messages to find the fault.
• check and repair field regulator control wiring
(command and feedback)
• check and repair K104 control wiring (command and
feedback)
• check and repair chopper
• check and repair gate unit power supply or control
wiring for the power supply (command and feedback)
• eliminate reason for totallock
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 124 of 218
TRACTION DRIVES / SE&A

1423+

event code and diagnosis message 1423 IUW: OUTPUT CURRENT SUPERVISION
(IDLE) INV A
description The absolute value of one inverter output current exceeds
the threshold after the inverter is out of operation for more
than 5 s.
threshold 100 A
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit Permanent inhibit inverter A (BRAM-buffered)
possible reasons Fault of inverter current measuring device
action to reset Limp mode for propel is possible after fault reset by driver
at standstill (limp mode for retard is enabled
automatically)
action to repair Exchange or repair faulty measuring device
SIEMENS-event code 111
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 125 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1424 IUW: OUTPUT CURRENT SUPERVISION
(IDLE) INV B
description The absolute value of one inverter output current exceeds
the threshold, while the inverter is not operating since at
least 5 s.
threshold 100 A
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit Permanent inhibit inverter B (BRAM-buffered)
possible reasons Fault of inverter current measuring device
action to reset Limp mode for propel is possible after fault reset by driver
at standstill (limp mode for retard is enabled
automatically)
action to repair Exchange or repair faulty measuring device
SIEMENS-event code 111
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 126 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1450 IUW: PRECHARGING SUPERVISION DC-
LINK VOLTAGE 1
description The DC bus voltage is less than the threshold, although the
field regulator is enabled for at least 360 ms.
threshold 50 V
software detection by CPU (G011) [T4]
protection reactions:
excitation Inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of control wiring (field regulator)
• fault of DC bus voltage measuring device
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair control wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 127 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1451 IUW: PRECHARGING SUPERVISION DC-
LINK VOLTAGE 2
description The DC bus voltage is less than the threshold, although the
alternator output control is enabled for at least 6 s.
threshold 500 V
software detection by CPU (G011) [T4]
protection reactions:
excitation Inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 128 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1453 IUW: PRECHARGING SUPERVISION


EXCITATION CURRENT 1
description
threshold
software detection by CPU (G011) [T4]
protection reactions:
excitation inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 129 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1454 IUW: PRECHARGING SUPERVISION


EXCITATION CURRENT 2
description
threshold
software detection by CPU (G011) [T4]
protection reactions:
excitation inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 130 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1456 IUW: TORQUE REDUCTION DUE TO
TROLLEY CONDITIONS
description During the DBT mode, if the trolley line voltage is
between 800V to 1000V not more than 10s, the torque is
reduced from 100% to 80% linearly. During the DT mode,
if the trolley line voltage is between 1800V to 2200V, the
torque need to be reduced from 100% to 75% linearly. If
the torque reduction keeps more than 5s.
threshold
software detection by CPU (G011) [T4]
protection reactions:
excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 131 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1457 IUW: TORQUE REDUCTION DUE TO DC-
LINK VOLTAGE
description
threshold
software detection by CPU (G011) [T4]
protection reactions:
excitation inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of DC bus voltage measuring device (transducer
U105)
action to reset “fault reset” by driver at standstill
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 132 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1458 DC-LINK VOLTAGE OUT OF ENVELOPE IN
PROPEL
description The DC bus voltage is out of the admissible range in
propel.
threshold 800/850 V (hysteresis for lower limit)
2875/2925 V (hysteresis for upper limit)
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B in propel
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)t
• fault of bus voltage measuring device (transducer
U105)
action to reset Automatic reset of inverter inhibit as soon as bus voltage
is back in the admissible range.
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code 81
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 133 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1459 DC-LINK VOLTAGE OUT OF ENVELOPE IN
RETARD
description The DC bus voltage is out of the admissible range in
retard.
threshold 800/850 V (hysteresis for lower limit)
3000/3050 V (hysteresis for upper limit)
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B in retard
possible reasons • alternator fault
• rectifier fault
• grid fault (grid open)
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)t
• fault of bus voltage measuring device (transducer
U105)
action to reset Automatic reset of inverter inhibit as soon as bus voltage
is back in the admissible range.
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair grids
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code 81
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 134 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1460 DC-LINK UNDERVOLTAGE SUPERVISION

description The difference between the bus voltage set point and the
measured bus voltage is more than the threshold. For 1 s
threshold 300 V
software detection by CPU (G011) [T1]
protection reactions:
inverter GTO pulse inhibit Immediate inhibit inverter A and B
excitation Inhibit excitation
possible reasons • alternator fault
• rectifier fault
• field regulator fault
• power cabling fault (alternator/rectifier/DC-link)
• fault of wiring (field regulator)
• fault of bus voltage measuring device (transducer
U105)
action to reset The TCU will try to charge-up the bus after some seconds
automatically. If the fault is still present the precharging
supervision (codes 1450 or 1451 will trigger).
action to repair • repair or exchange alternator
• repair or exchange rectifier
• repair or exchange field regulator
• repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code 82
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 135 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1461 IUW: TROLLEY LINE UNDERVOLTAGE
SUPERVISION
description During the DBT mode, if the trolley line voltage is less
than 800VDC in DBT or 1500VDC in DT for more than
500ms
threshold
software detection by CPU (G011) [T1]
protection reactions: The DISENGAGE SEQUENCE will be implemented
possible reasons • power cabling fault (alternator/rectifier/DC-link)
• fault of bus voltage measuring device (transducer
U105)
• trolley line problems
• pantograph problems
action to reset Automatic reset after trolley disconnect sequence
successful.
action to repair • exchange or repair faulty measuring device
• check pantograph pressure
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 136 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1463 IUW: TROLLEY LINE OVERVOLTAGE
SUPERVISION
description During the DBT mode if the trolley line voltage is greater
than 1850VDC or in DT above 2650Vfor 500ms.
threshold
software detection by CPU (G011) [T1]
protection reactions: The DISENGAGE SEQUENCE will be implemented.

possible reasons • power cabling fault (alternator/rectifier/DC-link)


• fault of bus voltage measuring device (transducer
U105)
action to reset Automatic reset after trolley disconnect sequence
successful.
action to repair • repair power cabling
• repair wiring
• exchange or repair faulty measuring device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 137 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1470 IUW: GROUND FAULT DETECTED

description The quotient of the filtered ground voltage (transducer


U106) and the filtered bus voltage (transducer U105) is
out of the allowed range. The detection is only active if the
DC-bus voltage is higher than 500 V.
threshold allowed range for quotient: 0,175 ... 0,325
software detection by CPU (G011) [T4]
protection reactions:
torque reduction “soft” torque reduction to zero in propel
inverter GTO pulse inhibit “soft” stop inverter A and B, if truck reaches standstill
excitation inhibit excitation as soon as inverters are stopped
drive shutdown transition to “drive shutdown” as soon as inverters are
stopped
possible reasons • ground fault
• fault of DC-bus voltage measuring device
• fault of ground voltage measuring device
action to reset • reset by driver at standstill possible, if event occurred
not more than three times within 10 minutes
• reset by service personnel (by monitor)
• suppression of all protection reactions as long as the
dump body override switch is pressed
action to repair • eliminate ground fault
• exchange or repair faulty measuring device
SIEMENS-event code 121
notes Under unfavorable circumstances a ground fault may
cause harm or danger to persons standing on the
ground and touching the truck chassis. Make sure that
nobody can touch the truck, when suppressing the
protection reactions with the override switch or when
you do testing to locate the ground fault at standstill !

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 138 of 218
TRACTION DRIVES / SE&A

Following this criteria help to locate the ground fault:

1) Activate the “drive shutdown” switch or select the mode using User-commands
Reset the inhibit by the reset-button or in User-commands . Watch bus-voltage and
ground voltage, check the diagnosis memory. If the bus-voltage comes up again, the
ratio of ground and bus voltage is correct and the ground fault detection does not
occur again, the ground fault is not on the alternator/rectifier side of the DC-link
contactor K104. If the ground fault detection occurs again, the fault must be on the
alternator/rectifier side.
2) If the ground fault is not on the alternator/rectifier side of K104, turn off the “drive
shutdown” switch. Watch the bus-voltage and the ground voltage and check the
diagnosis memory. If the bus-voltage comes up again, the ratio of ground and bus
voltage is correct and the ground fault does not occur again as long as the inverter
are not operating (truck at standstill, shift lever in “NEUTRAL”), the ground fault
must be on the inverter output side (e.g. motors).

3) Evaluate the filtered values for ground voltage and bus voltage stored in the
diagnosis memory for the ground fault detection:
• ground voltage = 0 V indicates a ground fault on the positive DC-bus
• ground voltage = bus voltage indicates a ground fault on the negative DC-bus
• ground voltage = ½ bus voltage indicates a ground fault on the alternator/rectifier
side or on the inverter/motor side

I²-t supervision DC-link current:

The I2-t supervision of the DC-link current prevents the alternator from sustained
overloading. The “I2-integral” is calculated as shown in the functional block diagram:

IDC

I2-integral
+1
sign
IDCN 100 % -1

T = 98 s

IDC : measured DC-link current (filtered)


IDCN : maximum continuous DC-link current (determined by maximum
alternator current)

The “I2-integral” is supervised and resulting in the “alternator over current warning”
(Code 1517) and the “alternator over current protection” (Code 1518).
AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003
COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 139 of 218
TRACTION DRIVES / SE&A

examples:

maximum continuous DC-link current : 807.6 A (DC) = 659 A (rms) alternator


current
measured DC-link current : 1076 A (DC) = 878 A (rms) alternator current
→ over current warning after 7,5 minutes
→ over current protection after 15 minutes

maximum continuous DC-link current : 807.6 A (DC) = 659 A (rms) alternator


current
measured DC-link current : 941.8 A (DC) = 768.5 A (rms) alternator current
→ over current warning after 30 minutes
→ over current protection after 60 minutes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 140 of 218
TRACTION DRIVES / SE&A

1511+

event code and diagnosis message 1511 IUW: TROLLEY LINE AND DC-LINK
CURRENT SUPERVISION UNDER TROLLEY
MODE
description During trolley mode, if the difference between trolley line
current and dc link current is greater than 200A for 3s
threshold 200A
software detection by CPU (G011)
protection reactions: The DISENGAGE SEQUENCE will be implemented.
possible reasons Faulty measuring devices
Faulty power cabling
SIEMENS-event code
notes

event code and diagnosis message 1513 TORQUE REDUCTION DUE TO THE I
SQUARE TIME
description - The “I²-integral” (Maximum Inverter peak current)
exceeds the protection-limit.
threshold 100%/95%
software detection by CPU (G011)
protection reactions: Reduce both inverter torque to 80%
possible reasons Inverter overload operation
SIEMENS-event code 42
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 141 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1514 TORQUE REDUCTION DUE TO THE TORQUE
SQUARE TIME
description - The “T²-integral” (Maximum Inverter torque) exceeds
the protection-limit.
threshold NO
software detection by CPU (G011)
protection reactions: Reduce both inverter torque to 80%
possible reasons Inverter overload operation
SIEMENS-event code 42
notes

event code and diagnosis message 1516 ALTERNATOR NEGATIVE CURRENT


PROTECTION
description -DC Link Current exceeds –200 A
threshold NO
software detection by CPU (G011)
protection reactions: Immediately inhibit field regulator and inverter
possible reasons Shorted rectifier or power cable
SIEMENS-event code
notes Check rectifier if there is any arcing between phases

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 142 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1517 IUW: ALTERNATOR OVERCURRENT


WARNING
description The “I²-integral” exceeds the warning-limit.
threshold 50/45 % (hysteresis)
software detection by CPU (G011)
protection reactions: No
possible reasons sustained alternator overload
SIEMENS-event code 42
notes

event code and diagnosis message 1518 IUW: ALTERNATOR OVERCURRENT


PROTECTION
description The “I²-integral” exceeds the protection-limit.
threshold 100 % (hysteresis)
software detection by CPU (G011)
protection reactions: not yet decided !
possible reasons sustained alternator overload
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 143 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1519 IUW: OVERCURRENT DC-LINK

description The filtered value of the DC-link current (transducer


U107) exceeds the allowed maximum for more than 120
ms.
threshold 1350 A/(1600A/2400A, direct trolley/diesel boost)
software detection by CPU (G011) [T3]
protection reactions:
inverter GTO pulse inhibit immediate inhibit inverter A and B
excitation immediate inhibit
drive shutdown transition to “drive shutdown” if over current lasts for
more than 5 s or occurs 5 times within 3 minutes
possible reasons • power circuit fault (e.g. short circuit)
• fault of DC-link current measuring device
action to reset • inverter inhibit resets automatically, if over current
disappears
• excitation inhibit resets automatically, if over current
disappears
• reset “drive shutdown” request by service personnel (by
monitor)
action to repair • eliminate power circuit fault
• repair/exchange faulty DC-link current measuring
device
SIEMENS-event code 115
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 144 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1520 TMP: INVERTER MODULE TEMPERATURE A
< OPERATION LIMIT
description The minimum module temperature of inverter A is less
than the operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit inhibit inverter A and B
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibit as soon as module
temperature is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.

event code and diagnosis message 1521 TMP: INVERTER MODULE TEMPERATURE A
> APRS-LIMIT
description The maximum module temperature of inverter A is higher
than the limit for the automatic power reduction system
(APRS).
threshold 64/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor A from 100% to 75% of
requested value between 64° and 67°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes The APRS-system can be disabled by the customer per
menu.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 145 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1522 TMP: INVERTER MODULE TEMPERATURE A
> SHUTDOWN-LIMIT
description The maximum module temperature of inverter A is higher
than the shutdown-limit.
threshold 67/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter A in retard
possible reasons insufficient power module cooling
action to reset • limp mode for propel is possible after a fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

event code and diagnosis message 1525 TMP: SNUBBER RESISTOR TEMPERATURE
A > WARNING-LIMIT
description The Snubber resistor temperature is higher than the
threshold for a warning.
threshold 90/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons Insufficient Snubber resistor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 146 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1526 TMP: SNUBBER RESISTOR TEMPERATURE
A > SHUTDOWN-LIMIT
description The temperature of Snubber resistor A is higher then the
shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit • “medium inhibit” inverter A and B in propel
• “medium inhibit” inverter A in retard
possible reasons Insufficient Snubber resistor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

event code and diagnosis message 1530 TMP: INVERTER MODULE TEMPERATURE B
< OPERATION LIMIT
description The minimum module temperature of inverter B is less
than the operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit inhibit inverter A and B
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibit as soon as module
temperature is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 147 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1531 TMP: INVERTER MODULE TEMPERATURE B
> APRS-LIMIT
description The maximum module temperature of inverter B is higher
than the limit for the automatic power reduction system
(APRS).
threshold 69/67 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor B from 100% to 75% of
requested value between 69° and 72°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes The APRS-system can be disabled by the customer.

event code and diagnosis message 1532 TMP: INVERTER MODULE TEMPERATURE B
> SHUTDOWN-LIMIT
description The maximum module temperature of inverter B is higher
than the shutdown-limit.
threshold 72/67 °C
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter B in retard
possible reasons Insufficient power module cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 148 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1535 TMP: SNUBBER RESISTOR TEMPERATURE
B > WARNING-LIMIT
description The Snubber resistor temperature is higher than the
threshold for a warning.
threshold 90/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions: No
possible reasons Insufficient Snubber resistor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes

event code and diagnosis message 1536 TMP: SNUBBER RESISTOR TEMPERATURE
B > SHUTDOWN-LIMIT
description The temperature of Snubber resistor B is higher then the
shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit • “medium inhibit” inverter A and B in propel
• “medium inhibit” inverter B in retard
possible reasons Insufficient Snubber resistor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibit as soon as
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 149 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1537 TMP: SNUBBER A/B DELTA T >
SHUTDOWN-LIMIT
description The difference value of maximum temperature of Snubber
resistors and ambient temperature is higher then the
shutdown-limit.
threshold 40/35 °C (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit “medium inhibit” inverter A and B in propel
possible reasons Insufficient Snubber resistor cooling
action to reset automatic reset of inverter inhibit as soon as temperature is
lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 150 of 218
TRACTION DRIVES / SE&A

1620+

event code and diagnosis message 1620 TMP: CHOPPER MODULE TEMPERATURE A
< OPERATION LIMIT
description The chopper module temperature A is less than the
operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit Inhibit inverter A and B
self load-test inhibit Test-test inhibit
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibits as soon as temperature
is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.

event code and diagnosis message 1621 TMP: CHOPPER MODULE TEMPERATURE A
> APRS-LIMIT
description The chopper module temperature A is higher than the limit
for the automatic power reduction system (APRS).
threshold 64/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard torque reduction motor A and B from 100%
to 75% of requested value between 64° and 72°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 151 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1622 TMP: CHOPPER MODULE TEMPERATURE A
> SHUTDOWN-LIMIT
description The chopper module temperature A is higher than the
shutdown-limit.
threshold 67/62 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation Inhibit excitation as soon as
• inverters are blocked and SHTS-system is active in
retard
• truck is at standstill and SHTS-system is active in
propel
test-test inhibit Test-test inhibit
possible reasons Insufficient power module cooling
action to reset Automatic reset of inhibits as soon as chopper temperature
is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 107, 114
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 152 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1627 TMP: GRID BLOWER SUPERVISION

description The event code will be stored if the chopper duty cycle is
higher than 10% and the feedback from the grid blower is
not “OK” for more than 5 s.
software detection by CPU (G011) [T7]
protection reactions: No
possible reasons
action to repair
SIEMENS-event code 43
notes Right now the grid blower feedback is always “LOW”
(14.4.99); threshold for chopper duty cycle has to be
adjusted once a feedback (e.g. from a pressure switch) is
installed

event code and diagnosis message 1628 TMP: RETARD GRID TEMPERATURE A >
APRS-LIMIT
description The retard grid temperature A is higher than the limit for
the automatic power reduction system (APRS).
threshold 270/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard power reduction motor A and B from 100%
to 75% of maximum value between 220° and 240°C
possible reasons Insufficient grid cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 153 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1629 TMP: RETARD GRID TEMPERATURE A >
SHUTDOWN-LIMIT
description The retard grid temperature A is higher than the shutdown-
limit.
threshold 300/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
test-test inhibit Test-test inhibit
possible reasons Insufficient grid cooling
action to reset Automatic reset of inhibits as soon as grid temperature is
lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 66, 107, 114, 115
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 154 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1630 TMP: CHOPPER MODULE TEMPERATURE B
< OPERATION LIMIT
description The chopper module temperature B is less than the
operation limit.
threshold -25/-24 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit Inhibit inverter A and B
test-test inhibit Test-test inhibit
possible reasons low ambient temperature
action to reset Automatic reset of inverter inhibits as soon as temperature
is OK for operation.
SIEMENS-event code
notes Preheating will be requested to warm the modules up.

event code and diagnosis message 1631 TMP: CHOPPER MODULE TEMPERATURE B
> APRS-LIMIT
description The chopper module temperature B is higher than the limit
for the automatic power reduction system (APRS).
threshold 69/67 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard torque reduction motor A and B from 100%
to 75% of requested value between 69° and 67°C
possible reasons Insufficient power module cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 155 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1632 TMP: CHOPPER MODULE TEMPERATURE B
> SHUTDOWN-LIMIT
description The chopper module temperature B is higher than the
shutdown-limit.
threshold 72/67 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation Inhibit excitation as soon as
• inverters are blocked and SHTS-system is active in
retard
• truck is at standstill and SHTS-system is active in
propel
test-test inhibit Test-test inhibit
possible reasons Insufficient power module cooling
action to reset Automatic reset of inhibits as soon as chopper temperature
is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 107, 114
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 156 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1638 TMP: RETARD GRID TEMPERATURE B >
APRS-LIMIT
description The retard grid temperature B is higher than the limit for
the automatic power reduction system (APRS).
threshold 270/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear retard power reduction motor A and B from 100%
to 75% of maximum value between 220° and 240°C
possible reasons Insufficient grid cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

event code and diagnosis message 1639 TMP: RETARD GRID TEMPERATURE B >
SHUTDOWN-LIMIT
description The retard grid temperature B is higher than the shutdown-
limit.
threshold 300/265 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
test-test inhibit Test-test inhibit
possible reasons Insufficient grid cooling
action to reset Automatic reset of inhibits as soon as grid temperature is
lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 66, 107, 114, 115
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 157 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1645 TMP: ALTERNATOR STATOR TEMPERATURE
> APRS-LIMIT
description The chopper module temperature B is higher than the limit
for the automatic power reduction system (APRS).
threshold 140/130 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear propel power reduction motor A and B from 100%
to 75% of maximum between 160° and 180°C
possible reasons Insufficient alternator cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61
notes The APRS-system can be disabled by the customer.

event code and diagnosis message 1646 TMP: ALTERNATOR STATOR TEMPERATURE
> SHUTDOWN-LIMIT
description The alternator stator temperature is higher than the
shutdown-limit.
threshold 160/130 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation Inhibit excitation as soon as truck is at standstill and
SHTS-system is active in propel
test-test inhibit Test-test inhibit
possible reasons Insufficient alternator cooling
action to reset Automatic reset of inhibits as soon as alternator
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 65, 115
notes The automatic shutdown-system can be disabled by the
customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 158 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1647 TMP: ALTERNATOR BEARING


TEMPERATURE > APRS-LIMIT
description The alternator bearing temperature is higher than the
APRS-limit.
threshold 95/85 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: Operator is informed of over temperature
possible reasons Insufficient grease in alternator bearing, see alternator
manual for re-greasing instructions.
Improper connection of alternator to engine flywheel,
check and adjust based on procedure in alternator section
of instruction manual.
action to reset Automatic reset of fault as soon as alternator bearing
temperature is lower than the limit
action to repair Check bearing, add grease as instructed
Check and adjust engine to alternator alignment
SIEMENS-event code 45
notes Bearing temperature sensor can be disabled in User-
parametes.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 159 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1648 TMP: ALTERNATOR BEARING


TEMPERATURE > SHUTDOWN-LIMIT
description The alternator bearing temperature is higher than the
Shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: Operator is informed of over temperature
possible reasons Insufficient grease in alternator bearing, see alternator
manual for re-greasing instructions.
Improper connection of alternator to engine flywheel,
check and adjust based on procedure in alternator section
of instruction manual.
action to reset Automatic reset of fault as soon as alternator bearing
temperature is lower than the limit
action to repair Check bearing, add grease as instructed
Check and adjust engine to alternator alignment
SIEMENS-event code 45
notes Bearing temperature sensor can be disabled in User-
parametes.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 160 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1650 TMP: TRACTION MOTOR TEMPERATURE A
> APRS-LIMIT
description The traction motor temperature A is higher than the limit
for the automatic power reduction system (APRS).
threshold 180/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor A and B from 100% to 75%
of requested value between 220° and 240°C
possible reasons Insufficient motor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 161 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1651 TMP: TRACTION MOTOR TEMPERATURE B
> APRS-LIMIT
description The traction motor temperature B is higher than the limit
for the automatic power reduction system (APRS).
threshold 180/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction Linear torque reduction motor A and B from 100% to 75%
of requested value between 220° and 240°C
possible reasons Insufficient motor cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

event code and diagnosis message 1653 TMP: TRACTION MOTOR TEMPERATURE A
> SHUTDOWN-LIMIT
description The traction motor temperature is higher than the
shutdown-limit.
threshold 200/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter A in retard
possible reasons Insufficient motor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibits as soon as motor
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 162 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1654 TMP: TRACTION MOTOR TEMPERATURE B
> SHUTDOWN-LIMIT
description The traction motor temperature is higher than the
shutdown-limit.
threshold 200/160 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
• “soft inhibit” inverter B in retard
possible reasons Insufficient motor cooling
action to reset • limp mode for propel is possible after fault reset by
driver at standstill
• automatic reset of inverter inhibits as soon as motor
temperature is lower than the shutdown-limit
action to repair Check and correct cooling system
SIEMENS-event code 111
notes The automatic shutdown-system can be disabled by the
customer.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 163 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1660 TMP: TRACTION MOTOR BEARING
TEMPERATURE A > WARNING-LIMIT
description The traction motor bearing temperature is higher than the
APRS-limit.
threshold 95/85 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: Operator is informed of over temperature
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.

action to reset Automatic reset of fault as soon as alternator bearing


temperature is lower than the limit
action to repair Check for oil leak in axle box, repair, and contact OEM
Check bearing, add grease as instructed
SIEMENS-event code 45
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 164 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1661 TMP: TRACTION MOTOR BEARING
TEMPERATURE B > WARNING-LIMIT
description The traction motor bearing temperature is higher than the
APRS-limit.
threshold 95/85 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: Operator is informed of over temperature
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.

action to reset Automatic reset of fault as soon as alternator bearing


temperature is lower than the limit
action to repair Check for oil leak in axle box, repair, and contact OEM
Check bearing, add grease as instructed
SIEMENS-event code 45
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 165 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1663 TMP: TRACTION MOTOR BEARING
TEMPERATURE A > SHUTDOWN-LIMIT
description The traction motor bearing temperature is higher than the
Shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T7]
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.

action to reset Automatic reset of fault as soon as alternator bearing


temperature is lower than the limit
action to repair Check for oil leak in axle box, repair, and contact OEM
Check bearing, add grease as instructed
SIEMENS-event code 45
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 166 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1664 TMP: TRACTION MOTOR BEARING
TEMPERATURE B > SHUTDOWN-LIMIT
description The traction motor bearing temperature is higher than the
Shutdown-limit.
threshold 100/85 °C (hysteresis)
software detection by CPU (G011) [T7]
inverter GTO pulse inhibit • “soft inhibit” inverter A and B in propel
possible reasons Oil leak in the gear boxes or axle box causing oil to flush
into the motor and bearing.
Insufficient grease in traction motor bearing(s), see
traction motor manual for re-greasing instructions.

action to reset Automatic reset of fault as soon as alternator bearing


temperature is lower than the limit
action to repair Check for oil leak in axle box, repair, and contact OEM
Check bearing, add grease as instructed
SIEMENS-event code 45
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 167 of 218
TRACTION DRIVES / SE&A

1729+

event code and diagnosis message 1729 TMP: MAIN BLOWER SUPERVISION

description The event code will be stored if the blower inverter set
point frequency is higher than 60 Hz for 120Hz blower or
25HZ for 60Hz blower and the feedback from the main
blower is not “OK” for more than 60 s.
software detection by CPU (G011) [T7]
protection reactions: Inhibit the propel if the fault last longer that 1 minute
possible reasons
action to repair
SIEMENS-event code 44
notes This fault can be masked by user parameter

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 168 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1763 TEMPERATURE TCU > WARNING-LIMIT

description The TCU temperature is higher than the warning limit.


threshold 75/70 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions: No
possible reasons • TCU blower failure (code 17)
• insufficient cooling air supply (e.g. from dirt on the
vent holes at the bottom of the TCU)
• fault of TCU temperature sensor IO-card (G035)
action to repair • repair or exchange TCU blower subassembly
• ensure proper cooling air supply
• exchange IO-card (G035)
SIEMENS-event code 45
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 169 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1764 TEMPERATURE TCU > SHUTDOWN-LIMIT

description The TCU temperature is higher than the shutdown limit.


threshold 80/70 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation
drive shutdown transition to “drive shutdown”
possible reasons • TCU blower failure (code 17)
• insufficient cooling air supply (e.g. from dirt on the
vent holes at the bottom of the TCU)
• fault of TCU temperature sensor IO-card (G035)
action to reset Inverter and excitation inhibit will last until the TCU is
switched off. Operation can be resumed after power-up of
the TCU, if the TCU-temperature is O.K. then.
action to repair • repair or exchange TCU blower subassembly
• ensure proper cooling air supply
• exchange IO-card (G035)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 170 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1765 OVERTEMPERATURE TCU: REQUEST TCU-
SHUTDOWN
description The TCU temperature is higher than the shutdown limit.
threshold
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation
drive shutdown transition to “drive shutdown”
possible reasons • TCU blower failure (code 17)
• insufficient cooling air supply (e.g. from dirt on the
vent holes at the bottom of the TCU)
• fault of TCU temperature sensor IO-card (G035)
action to reset Inverter and excitation inhibit will last until the TCU is
switched off. Operation can be resumed after power-up of
the TCU and if the TCU-temperature is O.K.
action to repair • repair or exchange TCU blower subassembly
• ensure proper cooling air supply
• exchange IO-card (G035)
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 171 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1778 TMP: INVERTER COMPARTMENT


TEMPERATURE > APRS-LIMIT
description The inverter compartment temperature is higher than the
limit for the automatic power reduction system (APRS).
threshold 75/73 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
torque reduction linear torque reduction motor A and B from 100% to 75%
of requested value between 75° and 80°C
possible reasons Insufficient inverter compartment cooling
action to repair Check and correct cooling system
SIEMENS-event code 45, 61, 62
notes The APRS-system can be disabled by the customer.

event code and diagnosis message 1779 TMP: INVERTER COMPARTMENT


TEMPERATURE > SHUTDOWN-LIMIT
description The inverter compartment temperature is higher than the
shutdown-limit.
threshold 80/73 °C (hysteresis)
software detection by CPU (G011) [T7]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
test-test inhibit Test-test inhibit
possible reasons Insufficient inverter compartment cooling
action to reset Automatic reset of inhibits as soon as compartment
temperature is lower than the shutdown-limit
action to repair check and correct cooling system
SIEMENS-event code 107, 114, 115
notes The automatic shutdown-system can be disabled by the
customer selectively for propel and retard.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 172 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1780 FAILURE SPEED SENSOR A

description The absolute motor speed value A is less than 0,1 1/s,
while the absolute motor speed value B is greater than 40
1/s. To set the speed sensor failure, this condition must be
true for at least 240 ms.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
possible reasons Fault/failure of speed measuring equipment.
action to reset • limp mode for propel is possible after reset by driver at
standstill, if only one speed sensor failed
• automatic reset of inverter inhibit if “tolerance band
condition” is fulfilled (e.g. in limp mode) and the “set
condition” for the speed sensor failure is not active
• reset of speed sensor failure by driver’s reset at
standstill, if both speed sensors (A and B) failed
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes speed sensor “tolerance band condition”:
• the quotient of the absolute motor speed values is
between 0.7 and 1.3
• the minimum of the absolute motor speed values is
higher than 3 1/s
The “tolerance band condition” is fulfilled if both conditions are
true for more than 2 s

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 173 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1781 FAILURE SPEED SENSOR B

description The absolute motor speed value B is less than 0,1 1/s,
while the absolute motor speed value A is greater than 40
1/s. To set the speed sensor failure, this condition must be
true for at least 240 ms.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
possible reasons Fault/failure of speed measuring equipment.
action to reset • limp mode for propel is possible after reset by driver at
standstill, if only one speed sensor failed
• automatic reset of inverter inhibit if “tolerance band
condition” is fulfilled (e.g. in limp mode) and the “set
condition” for the speed sensor failure is not active
• reset of speed sensor failure by driver’s reset at
standstill, if both speed sensors (A and B) failed
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes speed sensor “tolerance band condition”:
• the quotient of the absolute motor speed values is
between 0.7 and 1.3
• the minimum of the absolute motor speed values is
higher than 3 1/s
The “tolerance band condition” is fulfilled if both conditions are
true for more than 2 s

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 174 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1788 SUPERVISION MOTOR SPEED A DSP

description Speed sensor failure detection by DSP-software.


software detection by DSP A (G019) [T1] / CPU (G011) [T1]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter A in retard
possible reasons Fault/failure of speed measuring equipment.
action to reset • limp mode for propel possible after reset by driver at
standstill, if only one speed sensor failed
• automatic reset of inverter inhibit if reset-conditions
fulfilled (e.g. in limp mode)
• reset of speed sensor failure by driver’s reset at
standstill, if both speed sensors (A and B) failed
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes conditions for automatic reset:
• no speed sensor failure detection from DSP for more
than 2 s
• absolute motor speed value is higher than 0.1 1/s
• the “tolerance band condition” (see code 1780) is
fulfilled or both motor speed sensors failed

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 175 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1789 SUPERVISION MOTOR SPEED B DSP

description Speed sensor failure detection by DSP-software.


software detection by DSP B (G027) [T1] / CPU (G011) [T1]
protection reactions:
inverter GTO pulse inhibit • immediate inhibit inverter A and B in propel
• immediate inhibit inverter B in retard
possible reasons Fault/failure of speed measuring equipment.
action to reset • limp mode for propel is possible after reset by driver at
standstill, if only one speed sensor failed
• automatic reset of inverter inhibit if reset-conditions
fulfilled (e.g. in limp mode)
• reset of speed sensor failure by driver’s reset at
standstill, if both speed sensors (A and B) failed
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes conditions for automatic reset:
• no speed sensor failure detection from DSP for more
than 2 s
• absolute motor speed value is higher than 0.1 1/s
• the “tolerance band condition” (see code 1780) is
fulfilled or both motor speed sensors failed

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 176 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1790 SUPERVISION ENGINE SPEED DSP

description Speed sensor failure detection by DSP-software.


software detection by DSP A (G019) [T1] / CPU (G011) [T1]
protection reactions: no direct fault reaction, other events probably occur due to
engine speed value
possible reasons Fault/failure of speed measuring equipment.
action to reset • automatic reset of speed sensor failure if reset-
conditions fulfilled
• reset of speed sensor failure by service personnel (by
monitor)
action to repair Repair/exchange faulty speed measuring equipment.
SIEMENS-event code
notes conditions for automatic reset:
• no speed sensor failure detection from DSP for more
than 2 s
• absolute engine speed value is higher than 100 rpm

1815+

event code and diagnosis message 1815 MAXIMUM SPEED VIOLATION


(SYSTEM/MOTORS)
description One of the traction motors exceeded the maximum
permissible speed.
threshold 60/59.17 1/s (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
torque reduction “soft” propel torque reduction to zero (as long as
maximum speed is exceeded)
SIEMENS-event code 69
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 177 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 1816 MINIMUM VEHICLE SPEED SUPERVISION
FOR TROLLEY
description Under trolley mode, if the vehicle speed is less than set
minimum speed limit
threshold Adjustable
software detection by CPU (G011) [T6]
protection reactions: The ENGAGE SEQUENCE is not possible or the
DISENGAGE SEQUENCE will be implemented.
SIEMENS-event code
notes

event code and diagnosis message 1820 ROTATION DIRECTION INCONSISTENCY


A/B
description The message will be stored if the rotation directions of
motor A and B are different, no failure of one speed sensor
has been detected and the absolute speed values are not
very low (hysteresis 1.0/1.5 1/s).
software detection by CPU (G011) [T2]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B if rotation direction
inconsistency lasts for more than 5 s
possible reasons speed sensor problem
action to reset Automatic reset of inverter inhibit as soon as rotation
directions are consistent
action to repair check and repair/exchange faulty speed measuring device
SIEMENS-event code 115
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 178 of 218
TRACTION DRIVES / SE&A

1963+

event code and diagnosis message 1963 SHIFT LEVER VALIDATION FAILURE

description The message will be stored if the feedbacks from the shift
lever (forward, reverse, neutral) do not clearly indicate the
shift lever position for more than 1.2 s.
software detection by CPU (G011) [T6]
protection reactions: The last valid shift lever position will not be changed, as
long as the truck moves; once the truck reaches standstill,
the shift lever position will be regarded as “neutral” until a
different position is clearly indicated. With the shift lever
position “neutral” no propel torque is possible.
possible reasons • shift lever fault
• shift lever wiring fault
• fault of binary input converter card (2B: G127, 2A:
G135)
action to repair • repair/exchange shift lever
• repair shift lever wiring
• exchange binary input converter card (2B: G127, 2A:
G135)
SIEMENS-event code 68
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 179 of 218
TRACTION DRIVES / SE&A

2009+

event code and diagnosis message 2009 SIV: EXCITAION CURRENT SETPOINT
SUPERVISION
description The excitation current set point is at its upper limit for
more than 10 s.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation as soon as inverters are out of operation
possible reasons Disturbance of bus voltage control by faulty measured
values or faulty field regulator.
action to reset Reset by driver at standstill.
action to repair • check and repair bus voltage measuring equipment
(transducer U105)
• repair/exchange field regulator
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 180 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2029 SIV: MAIN BLOWER CONTACTOR
SUPERVISION
description The message will be stored, if the feedback signals from
the main blower contactors K141, K142 and K143 do not
reflect the status requested from the TCU for more than 2
s.
software detection by CPU (G011) [T6]
protection reactions: If the blower inverter is not yet connected to the power
supply (commands for K141 and K143 “LOW”), the
sequence to connect it to the power supply won’t start.
If the blower inverter is already connected to the power
supply, it will be disconnected from the power supply if
the 2.4 tap connection is active.
As the blower is not able to work without the inverter
connected, the drive system will be without cooling and
secondary faults may occur.
possible reasons • fault of contactors or auxiliary status contactors
• fault of contactor control wiring (command and
feedback)
• fault of binary input converter card (2B: G151, 2A:
G103)
• fault of binary output contactor drive (2B: C019, 2A:
G119 for K141; 2B: C011, 2A: G127 for K142)
action to repair • exchange faulty contactor
• repair control wiring
• exchange faulty binary input converter care
• exchange faulty binary output contactor drive
SIEMENS-event code 44
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 181 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2031 SIV: SUPERVISION DC-LINK


CONTROLLER
description The bus voltage is less than 85% of the bus voltage set
point for more than 10 s.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation as soon as inverters are out of operation
possible reasons Disturbance of bus voltage control by faulty measured
values or faulty field regulator.
action to reset Reset by driver at standstill.
action to repair • check and repair bus voltage measuring equipment
(transducer U105)
• repair/exchange field regulator
SIEMENS-event code
notes

event code and diagnosis message 2033 SIV: TORQUE SUPERVISION DRIVE A

description With a torque reference of zero the calculated real torque


exceeds the threshold for more than 2 s.
threshold 1250 Nm
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit immediate inhibit for 2 s
possible reasons disturbance of torque control (e.g. by faulty measured
values)
action to repair check and correct measuring equipment for inverter
currents, and motor speeds
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 182 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2053 SIV: TORQUE SUPERVISION DRIVE B

description With a torque reference of zero the calculated real torque


exceeds the threshold for more than 2 s.
threshold 1250 Nm
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit immediate inhibit for 2 s
possible reasons disturbance of torque control (e.g. by faulty measured
values)
action to repair check and correct measuring equipment for inverter
currents, and motor speeds
SIEMENS-event code
notes

event code and diagnosis message 2091 SIV: CHOPPER A HAS OPEN OR SHORT
CIRCUIT
description The measured mean value for the chopper current A is less
than 50 A, while the calculated value (from DC-bus
voltage and chopper modulation degree) is higher than 100
A or chopper A current is 200 A higher than chopper B
current. If these conditions are fulfilled for more than 2 s
the message will be stored.
software detection by CPU (G011) [T4]
protection reactions: No
possible reasons • chopper fault
• grid fault (e.g. grid failed open)
• fault of chopper current measuring device
action to repair • eliminate chopper fault
• correct grid fault
• repair/exchange faulty chopper current measuring
device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 183 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2092 SIV: CHOPPER B HAS OPEN OR SHORT
CIRCUIT
description The measured mean value for the chopper current B is less
than 50 A, while the calculated value (from DC-bus
voltage and chopper modulation degree) is higher than 100
A or chopper B current is 200 A higher than chopper A
current. If these conditions are fulfilled for more than 2 s
the message will be stored.
software detection by CPU (G011) [T4]
protection reactions: No
possible reasons • chopper fault
• grid fault (e.g. grid failed open)
• fault of chopper current measuring device
action to repair • eliminate chopper fault
• correct grid fault
• repair/exchange faulty chopper current measuring
device
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 184 of 218
TRACTION DRIVES / SE&A

2113+

event code and diagnosis message 2113 EXT: FAILURE AUXILIARY INVERTER

description The status feedback signal from auxiliary inverter


indicates a fault while blower operation is required for
more than 60 s.
software detection by CPU (G011) [T4]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B
excitation inhibit excitation as soon as inverters are out of operation
possible reasons • auxiliary inverter failure (check internal fault memory
for analysis)
• fault of blower inverter feedback signal wiring
• fault of blower enable command signal wiring
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset Automatic restart after some seconds.
action to repair • repair or exchange blower inverter
• repair feedback signal wiring
• repair enable command signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code 82
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 185 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2114 EXT: FAILURE FIELD REGULATOR

description The “enable”-command for the field regulator is “HIGH”


for at least 1 s, but the status feedback from the field
regulator is “LOW”.
software detection by CPU (G011) [T6]
protection reactions:
excitation inhibit excitation; permanent inhibit excitation (BRAM-
buffered), if event happens 5 times within 1 minute.
possible reasons • field regulator failure
• alternator fault
• fault of enable command signal wiring
• fault of feedback signal wiring
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset Automatic restart after some seconds. Reset by service
personnel (monitor), if excitation inhibit is permanent.
action to repair • repair or exchange field regulator
• repair or exchange alternator
• repair enable command signal wiring
• repair feedback signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code 82
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 186 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2115 EXT: BATTERY CHARGER


OVERTEMPERATURE
description The bus precharging is finished for at least 2.25 s, but the
status feedback from the battery charger is “HIGH”.
software detection by CPU (G011) [T8]
protection reactions: no
possible reasons • failure battery charger
• fault of feedback signal wiring
• fault of binary input converter card (2B: G143, 2A:
L119)
action to repair • repair or exchange battery charger
• repair feedback signal wiring
• exchange faulty binary input converter card
SIEMENS-event code 44
notes This fault can be masked by user parameter setting

event code and diagnosis message 2116 EXT: ENGINE DERATE PROTECTION

description The engine feedback signal indicates an engine problem.


software detection by CPU (G011) [T6]
protection reactions:
inverter GTO pulse inhibit “soft stop” inverter A and B in propel (2s delay)
possible reasons • engine fault
• fault of feedback signal wiring
action to reset Automatic reset of inverter inhibit as soon as feedback
signal does no longer indicate an engine problem.
action to repair • correct engine problem
• repair feedback signal wiring
SIEMENS-event code 70
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 187 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2117 EXT: TRUCK PLUG MONITORING

description Truck plug is not connected or loose.


software detection by CPU (G011) [T7]
protection reactions: No
SIEMENS-event code 44
notes

event code and diagnosis message 2118 EXT: MINIMUM ENGINE SPEED
SUPERVISION
description The engine speed is lower than the threshold set for the
enabling of the field regulator.
threshold 10 / 9.2 1/s (600 / 552 rpm) (hysteresis)
software detection by CPU (G011) [T6]
protection reactions:
excitation disabling of the field regulator
possible reasons • engine failure
• fault/failure of engine speed measuring device
action to reset Automatic reset of field regulator inhibit as soon as engine
speed is high enough.
action to repair • correct engine problem
• repair/exchange faulty speed measuring device
SIEMENS-event code
notes Secondary reactions will take place due to the inhibit of
the field regulator.

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 188 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2120EXT: BOTH INVERTER JUMPERS ARE
MISSING
description Both inverter enable jumper located at X100 are missing
threshold No
software detection by G119
protection reactions: Transfer to drive shutdown mode
excitation Disable and re-enable
possible reasons • Wiring
• G119 card
action to repair • correct wiring problem
• replace G119 card
SIEMENS-event code
notes .

event code and diagnosis message 2121 EXT: FAILURE STEERING ENCORDER

description Steering encoder is out of range or it’s output doesn’t


match the wheel motor difference
threshold 1%/99%,
software detection by G035
protection reactions: Disable different torque control
excitation
possible reasons • Wiring
• Steering encoder
action to repair • correct wiring problem
• replace steering encoder
SIEMENS-event code 40
notes .This fault can be masked by user parameter setting

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 189 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2122 EXT: AUTO-LUBE IS NOT FUNCTIONING

description Auto Lube feedback is missing for over 30 minute when


engine speed is higher than 650rpm
threshold No
software detection by G119
protection reactions: Turn on Buzzer
excitation
possible reasons • Wiring
• Auto-Lube relay
• G119 card
action to repair • correct wiring problem
• Replace the relay by OEM
• Replace G119
SIEMENS-event code 37
notes . This fault can be masked by user parameter setting

event code and diagnosis message 2123 EXT: AXLE BOX OVERTEMPERATURE

description Axle Box is over temperature for over 10s


threshold No
software detection by G127
protection reactions: Turn on Buzzer
excitation
possible reasons • Wiring
• Temperature relay
• G127 card
action to repair • correct wiring problem
• Replace the relay by OEM
• Replace G127
SIEMENS-event code 38
notes . This fault can be masked by user parameter setting

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 190 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2124 EXT:GRID FAN CONTROL CIRCUIT
FAILED
description Grid blower circuit current is outside expected range >10s
threshold Current must be >20A and with in expected values
software detection by L095
protection reactions: Contactor K191 is opened, propel is inhibited, fault light
and buzzer inform operator of problem.
20s after the fault has been logged retard is disabled
action to reset Reset is required using operator reset button once the truck
is at standstill.
possible reasons • Wiring
• Software settings for RG1, RG2, RG3, and Motor
resistance. (Set in User – Parameters)
• Grid blower current transducer (U171)
• L095 card
action to repair • Correct wiring problem
• Check/adjust software settings
• Replace U171
• Replace L095 card
SIEMENS-event code 43
notes This fault is serious, repair before sending to production

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 191 of 218
TRACTION DRIVES / SE&A

2201+

event code and diagnosis message 2201 START-UP SEQUENCE: K104 DOES NOT
OPEN
description After the power-up, the TCU will try to open K104, if the
feedback signals from K104 does not clearly indicate that
K104 is open. If the feedback signals still do not indicate
K104 to be open 10 s after the TCU tried to open K104,
the code 2201 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not continue with the next step
as long as the feedback signals from K104 do not indicate
K104 to be open.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair dc-voltage sensor if measuring too high
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 192 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2202 START-UP SEQUENCE: THE TROLLEY
RELATED CONTACTORS ARE OPEN
description After the power-up, the TCU will try to open K303/304,
CB301, K305, K306, K307 and K308, if the feedback
signals from these contactors do not clearly indicate that
they are open after 10 s
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not continue with the next step
as long as the feedback signals are not correct.
possible reasons • fault of trolley contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 193 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2203 START-UP SEQUENCE: GATE UNIT POWER
SUPPLY NOT ENABLED
description The TCU enables the Gate Unit power supply during the
start-up sequence. If the feedback signal from the Gate
Unit power supply does not indicate that the supply is
working within 5 s, the code 2203 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not continue with the next step
as long as the feedback does not indicate that the gate unit
power supply is working.
possible reasons • gate unit power supply failure
• fault of signal wiring (command and feedback signals
for the gate unit power supply)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair or exchange gate unit power supply
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 194 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2204 START-UP SEQUENCE: INVERTER TEST
DOES NOT TERMINATE
description The TCU performs an inverter test during the start-up
sequence. The message 2204 will be stored, if the test does
not terminate within 30 s.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not be terminated. No operation
is possible
possible reasons CPU software fault.
action to reset switch off / switch on - sequence TCU
action to repair CPU-software has to be corrected by SIEMENS.
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 195 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2205 START-UP SEQUENCE: K104 DOES NOT
CLOSE
description The TCU will try to close contactor K104 during the start-
up sequence (if start-up to normal operation). If the
feedback signals from K104 do not clearly indicate that
K104 is closed within 30 s, the event code 2205 will be
stored.
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not be terminated as long as the
feedback signals do not indicate that K104 is closed.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • replace dc-bus voltage transducer if offset present
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 196 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2206 START-UP SEQUENCE: CB301 OR K306
ARE NOT CLOSED
description The TCU will try to close contactor CB301 and K306
during the start-up sequence (if start-up to normal
operation). If the feedback signals from these do not
clearly indicate that they are closed within 30 s
software detection by CPU (G011) [T6]
protection reactions: The start-up sequence will not be terminated as long as the
feedback signals do not indicate that they are closed.
possible reasons • fault of contactor CB301 or K306
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 197 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2211 TRANS. TO DRIVE SHUTDOWN: DC-LINK
NOT DISCHARGED
description During the transition to “drive shutdown” the TCU will try
to discharge the bus with the choppers. If the measured
bus voltage does not indicate that the bus is discharged
within 10 s, event code 2211 will be stored.
software detection by CPU (G011) [T6]
protection reactions:
transition to “drive shutdown” The sequence will not continue with the next step until the
bus is discharged.
possible reasons • chopper fault
• fault of bus voltage measuring device
• TCU fault (suppressing chopper commands), check
diagnosis memory for other messages
action to reset switch off / switch on - sequence TCU
action to repair • correct chopper fault
• repair or exchange bus voltage measuring device
• correct TCU fault
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 198 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2212 TRANS. TO DRIVE SHUTDOWN: K104
DOES NOT OPEN
description During the transition to “drive shutdown” the TCU tries to
open K104. If the feedback signals do not clearly indicate
that K104 is open within 30 s, event code 2212 will be
stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “drive shutdown” will not continue with
the next step as long as the feedback signals from K104 do
not indicate that K104 is open.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • replace DC-bus voltage transducer if offset present
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 199 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2213 TRANS. TO DRIVE SHUTDOWN: THE
TROLLEY RELATED CONTACTORS ARE NOT
CORRECT
description During the transition to “drive shutdown”, the TCU will
try to open CB301 and close K306. If the feedback signals
do not indicate the contactors to be in the correct positions
30s after the TCU commands
software detection by CPU (G011) [T6]
protection reactions: The transition to “drive shutdown” will not continue with
the next step as long as the feedback signals are not
correct.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 200 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2215 TRANS. TO STB-IDLE: FIELD


REGULATOR NOT DISABLED
description During the transition to “standby-idle” the TCU will
disable the field regulator. If the feedback signal do not
indicate that the field regulator is disabled within 15 s,
event code 2215 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “standby-idle” will not continue with the
next step as long as the feedback signal does not indicate
that the field regulator is disabled.
possible reasons • field regulator fault
• fault of signal wiring (command and feedback signals
for the field regulator)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair/exchange field regulator
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 201 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2216 TRANS. TO STB-IDLE: GATE UNIT
POWER SUPPLY NOT OK
description The TCU enables the Gate Unit power supply during the
transition to “standby-idle”. If the feedback signal from
the Gate Unit power supply does not indicate that the
supply is working within 10 s, the code 2216 will be
stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “standby-idle” will not continue with the
next step, as long as the feedback does not indicate that the
gate unit power supply is working.
possible reasons • gate unit power supply failure
• fault of signal wiring (command and feedback signals
for the gate unit power supply)
• fault of binary input converter card (2B: G111, 2A:
G103)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair or exchange gate unit power supply
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 202 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2217 TRANS. TO STB-IDLE: K104 DOES NOT
CLOSE
description The TCU will try to close contactor K104 during the
transition to “standby idle”. If the feedback signals from
K104 do not clearly indicate that K104 is closed within 30
s, the event code 2217 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The transition to “standby idle” will not continue with the
next step, as long as the feedback signals do not indicate
that K104 is closed.
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • replace DC-bus voltage transducer if offset is found
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 203 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2218 TRANS. TO STB-IDLE: THE TROLLEY
RELATED CONTACTORS ARE NOT CORRECT
description During the transition to “stand by idle”, the TCU will try
to open K303/K304, K305, K307, K308. If any of these
feedback signals still do not indicate the contactors to be
opened 30s after TCU commands to open them
software detection by CPU (G011) [T6]
protection reactions: The standby idle sequence will not continue with the next
step as long as the feedback signals from the above
contactors do not indicate they are opened.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 204 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2221 IPM TURNOFF-SEQ.: K104 DOES NOT
OPEN
description During the “IPM turnoff-sequence” the TCU tries to open
K104. If the feedback signals do not clearly indicate that
K104 is open within 30 s, event code 2221 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The “IPM turnoff-sequence” will not continue with the
next step as long as the feedback signals from K104 do not
indicate that K104 is open.
possible reasons • fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 205 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2222 IPM TURNOFF-SEQ: K104 DOES NOT
CLOSE
description During the “IPM turnoff-sequence” the TCU tries to close
K104. If the feedback signals from K104 do not clearly
indicate that K104 is closed within 30 s, the event code
2222 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The “IPM turnoff-sequence” will not continue with the
next step, as long as the feedback signals do not indicate
that K104 is closed.
possible reasons • fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 206 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2223 IPM TURNOFF-SEQ.: FIELD REGULATOR
NOT ENABLED
description At the end of the “IPM turnoff-sequence” the TCU will
enable the field regulator. If the feedback does not indicate
that the field regulator is enabled within 5 s, the event
code 2223 will be stored.
software detection by CPU (G011) [T6]
protection reactions: The “IPM turnoff sequence” will not terminate, as long as
the feedback does not indicate that field regulator is
working.
possible reasons • fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • repair or exchange field regulator
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 207 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2224 IPM TURNOFF-SEQ.: THE TROLLEY
RELATED CONTACTORS ARE NOT OPEN
description During the transition to “IPM TURNOFF-SEQ”, the TCU
will try to open K303/K304, K305, K307, K308. If any of
these feedback signals still do not indicate the contactors
to be open 30s after the TCU commands to open them
software detection by CPU (G011) [T6]
protection reactions: The standby idle sequence will not continue with the next
step as long as the feedback signals from the above
contactors do not indicate they are open.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 208 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2225 IPM TURNOFF-SEQ.: THE TROLLEY
RELATED CONTACTORS ARE NOT CLOSED
description During the transition to “IPM TURN-OFF ”, TCU will try
to close K306 and CB301. If the feedback signals from
K306 and CB301 don’t indicate that CB301 or K306 is
closed within 30s
software detection by CPU (G011) [T6]
protection reactions: The stand by idle sequence will not continue with the next
step as long as the feedback signals from the above
contactors do not indicate they are closed.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to reset switch off / switch on - sequence TCU
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 209 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2231 POWER-DOWN SEQUENCE: K104 DOES NOT
OPEN
description During the power-down sequence the TCU tries to open
K104. If the feedback signals do not clearly indicate that
K104 is open within 10 s, event code 2231 will be stored.
software detection by CPU (G011) [T6]
protection reactions: no
possible reasons • measured DC-bus voltage >30/40V, check fault listing
• fault of contactor K104
• fault of signal wiring (command and feedback signals
for K104)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • replace DC-bus voltage transducer if offset is found
• exchange contactor K104
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 210 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2232 POWER-DOWN SEQUENCE: CB301 DOES
NOT OPEN
description During the transition to “POWER-DOWN”, the TCU will
try to open CB301. If any of these feedback signals still do
not indicate the contactors to be opened 30s after TCU
commands to open them
software detection by CPU (G011) [T6]
protection reactions: no
possible reasons • fault of contactor cb301
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • exchange contactor
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 211 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2234 ENGAGE SEQUENCE: TROLLEY ENGAGE
SEQUENCE INCOMPLETE
description During the transition from D3 to DBT sequence, the TCU
will try to raise pantograph, close K303/K304, open
K306, move K307 to position 2, close K305. If not in
trolley active mode 8s after TCU commands engage
software detection by CPU (G011) [T6]
protection reactions: The circuit breaker will be opened, lower pantograph and
go back to diesel mode.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 212 of 218
TRACTION DRIVES / SE&A

event code and diagnosis message 2235 DISENGAGE SEQUENCE: TROLLEY ENGAGE
SEQUENCE INCOMPLETE
description During the transition from DBT to D3 sequence, TCU
will try to open K305, move K307 to position 1, close
K306, open K303/K304, and low pantograph. If the
feedback signals don’t indicate the pantograph and
contactors correctly 8s after TCU commands them
software detection by CPU (G011) [T6]
protection reactions: The circuit breaker will be opened, lower pantograph and
go back to diesel mode.
possible reasons • fault of contactors
• fault of signal wiring (command and feedback signals)
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
action to repair • exchange contactors
• repair control signal wiring
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 213 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 2249 WARNING: FEEDBACK SIGNAL K101
INCONSISTENT
Description The TCU tries to close contactor K101 as long as it is
operational. The event code 2249 will be stored if the
feedback indicates that K101 is open.
Software detection by CPU (G011) [T8]
Protection reactions: no
Possible reasons • fault of signal wiring (command and feedback signals
for K101)
• fault of contactor K101
• fault of binary input converter card (2B: G119, 2A:
G111)
• fault of binary output contactor drive (2B: C003, 2A:
G119)
Action to repair • repair control signal wiring, connect power and
feedback together to bypass status contactor.
• exchange contactor K101
• exchange faulty binary input converter card
• exchange faulty binary output contactor drive
SIEMENS-event code 41
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 214 of 218
TRACTION DRIVES / SE&A

2389+

Event code and diagnosis message 2389 BM: SERVICE BRAKE APPLICATION
ABOVE SPEED LIMIT
Description If the feedback from the service brake pedal indicates that
the pedal is pressed and the truck speed is higher than the
threshold, the event code 2389 is stored.
Threshold 5 mph
Software detection by CPU (G011) [T6]
Protection reactions: no
Possible reasons service brake application above speed limit
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 215 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 2392 DATA STORE SWITCH IS PRESSED

Description Log a code and save the current data into memory
Software detection by G127
Protection reactions: no
Possible reasons • Switch is pressed
• Wiring error
• G127 card
Action to repair Not necessary unless this code is active all the time, then
should try to correct the wiring or replace G127 card
SIEMENS-event code
notes

Event code and diagnosis message 2396 DM: FAILURE DIAGNOSIS MEMORY

Description Diagnosis code error.


Software detection by CPU (G011) [P2]
Protection reactions: no
Possible reasons CPU software fault.
Action to repair CPU software has to be corrected by SIEMENS.
SIEMENS-event code
notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 216 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 2397 DM: DIAGNOSIS MEMORY OCCUPATION >
75 %
Description The diagnosis memory occupation is higher than 75 %.
Software detection by CPU (G011) [T8]
Protection reactions: no
Possible reasons Many events stored in the diagnosis memory.
Action to reset Clear diagnosis memory.
SIEMENS-event code
Notes

Event code and diagnosis message 2398 DM: DIAGNOSIS MEMORY FULL

Description The diagnosis memory is full.


Software detection by CPU (G011) [T8]
Protection reactions: No
Possible reasons Many events stored in the diagnosis memory.
Action to reset Clear diagnosis memory.
SIEMENS-event code
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 217 of 218
TRACTION DRIVES / SE&A

Event code and diagnosis message 2399 TEST EVENT

Description The diagnosis memory can be tested with the monitor


command “EVENTS Test-Code”. An event with the code
2399 will be stored.
Software detection by CPU (G011) [T8]
Protection reactions: No
Notes

AC Haul Truck Troubleshooting Guide Revision: 2.0 7/10/2003


COPYRIGHT  Siemens Energy and Automation, Inc. All Rights Reserved. Pages 218 of 218