A = CAN High
TCM ‘pass through’ connections CANNOT be used with TCM ‘stub’ installations.
B = CAN Low
C = Shield Maximum network length is 40 m. For shielded networks (J1939-11), stub lengths are not included; with unshielded
networks (J1939-15), stub lengths are included in the overall network length. K. Karch - 05/30/05
Two 120 ohm TERMINATION BACKBONE - the cable Stubs must be spaced Allison 4th Generation TCM
RESISTORS required; one at between the two termination > 10 cm apart.
each end of the backbone. resistors. It and the stubs must 49 J1939 SHIELD
They always use blue wedge be 120 ohm impedance cable. 8 J1939 LOW
locks. Parts shown have the As shown, the backbone can CAN1
28 J1939 HIGH
resistor built in the casing. pass through bulkhead
7 INTERNAL TR
connectors. NOTE: Wire twist is
not shown for clarity.
Allison Transmission MY07 Datalink Communications – June 2006 SECTION C: SAE J1939 – 240