Professional Documents
Culture Documents
HORIZONTAL SUPPORT
CONNECTOR PLATE
9"
(TYP.)
3/8" FLANGED HEX NUT
2"
3"
5-7/8"
HOLD-DOWN CLAMP
& EXPANSION GUIDE 6"
6.25"
H B
W2
o R
90
W*
R*
o
90
3" W1 90o HORIZONTAL ELBOW
o
A W1 W1
90 VERTICAL
OUTSIDE ELBOW R*
30" R*
W2
DROPOUT TEE WITH OUTSIDE
VERTICAL RISER TAP 16"
B W2
HORIZONTAL CROSS
3" 1" x 1-5/8" 12 GA. STRUT
H*
A WALL BRACKET, HEAVY DUTY
TIN PLATED 4/O COPPER CABLE
oR 7/16" DIA. FIXED COLLAR COPPER LUG GREEN INSULATION
W* 90 HOLES LOOSE COLLAR
(ADJUSTABLE)
W* H+5.5"
W*+5.5" 20"
6"
RAIN HOOD
ASSEMBLY
WALL PENETRATION SLEEVE US
12B 81 lbs/ft - 12' span C A412B 1 A41 12' 0.60 in2 1000
12C 100 lbs/ft - 12' span D-3M A412C 1 A41 12', 24’ 0.60 in 2 1000
4" 3"
20A 58 lbs/ft - 20' span D-6M A420A 2 A42 12’, 20' 1.50 in2 1600
20B 85 lbs/ft - 20' span E-6M A420B 2 A42 20', 24’ 1.50 in 2 1600
12B 78 lbs/ft - 12' span C A512B 1 A51 12' 1.00 in2 1200
5" 4" 20A 57 lbs/ft - 20' span D-6M A520A 2 A52 12’, 20' 1.50 in 2 1600
SIDE LOAD 20C 115 lbs/ft - 20' span E-6M A520C 2 A52 20' 1.50 in 2 1600
RAIL DEPTH
HEIGHT 12B 89 lbs/ft - 12' span D-3M A612B 1 A61 12' 1.00 in2 1200
12C 105 lbs/ft - 12' span D-3M A612C 1 A61 12' 1.00 in 2 1200
20A 62 lbs/ft - 20' span D-6M A620A 2 A62 12’, 20' 1.50 in2 1600
Cable Tray Cross-Section
6" 5" 20B 80 lbs/ft - 20' span E-6M A620B 2 A62 20', 24’ 1.50 in 2 1600
• Extruded aluminum alloy 6063-T6
• Side rails are I-Beam profiles 20C 109 lbs/ft - 20' span E-6M A620C 2 A62 12’, 20’, 24' 2.00 in2 2000
• Rungs are 1-1/8" square tubes 20C+ 104 lbs/ft - 24' span E-6M A624C 3 A63 20', 24’ 2.00 in 2 2000
with open slot facing down
20C++ 128 lbs/ft - 25' span E-6M A620D 3 A63 20', 25’ 2.00 in2 2000
• Arc-welded construction
12C 100 lbs/ft - 12' span D-3M A712C 1 A71 12' 1.00 in 2 1200
• U.L. Classified grounding
20C 108 lbs/ft - 20' span E-6M A720C 2 A72 20', 24’ 2.00 in2 2000
• U.L. Certified load capacities 7" 6"
• NEMA, CSA and NEC Compliant 20C+ 111 lbs/ft - 24' span E-6M A720D 3 A73 20', 25’ 2.00 in 2 2000
• Necessary Splice Plates with 20C++ 105 lbs/ft - 30' span E-6M A720E 3 A73 20’, 30' 2.00 in 2 2000
hardware are included with all
straight sections and fittings 8" 7" 20C++ 114 lbs/ft - 40' span E-6M A820E 4 A84 30', 40’ 2.00 in2 2000
• Made in the USA
Catalog Numbers for Straight Tray Sections Non-standard lengths
and widths are
available; consult
Example: A620C - 09(*) - SL20 - 24 - S factory for lead times
All USTray aluminum cable trays are Bottom Type Optional Rungs Item Length Width Hardware
classified by Underwriters Laboratories CableTray 06 - 6" Rung Spacing and Bottoms 10 - 10'-0” 06 - 6" Finish
as suitable for use as equipment Code
System
grounding conductors per NEC 392 Number 09 - 9" Rung Spacing BLANK - Standard
SL
12 - 12'-0" 09 - 9" G - Geomet
and are certified by UL to meet all 12 - 12" Rung Spacing Insert 2-Digit 20 - 20'-0” 12 - 12" Plated
requirements of CSA Std. C22.2 No. Select Straight Steel
VT - Ventilated/Trough Bottom Code 24 - 24'-0” 18 - 18"
126. All NEMA and CSA safe load data from chart Length
is based on destruction load tests that above
(See Below) 25 - 25'-0” 24 - 24" S - Stainless
SF - Solid Flat Bottom to specify Steel 316
were witnessed and certified to be 30 - 30'-0" 30 - 30"
accurate by Underwriters Laboratories. SFU - Solid Flat Bottom, optional rungs
and bottoms 40 - 40'-0” 36 - 36"
Under Rungs
Note: This calculation is based on the load being applied at the center of the tray in 100 (149) 8C 12C 16C 20C
the middle of a rung or bottom. If the specification requires the concentrated static
load to be applied on top of one side rail, then the equivalent uniform load will be 2 120 (179) D*
times the result of this calculation. E*
200 (299)
Example: A cable tray is to be supported on 20’ spans. It shall contain 50 lbs/ft of * CSA Classes D and E are applicable to both 3.0 and 6.0 meter
cables and support 15 lbs/ft of snow load. It is also required to support a 250 pound support spans. The appropriate support span should also be included
concentrated static load applied in the center of the tray width. when specifying these classes (example: D-3M).
Using the calculation above, the concentrated static load is converted to an
equivalent uniform load as follows: 2 x 250 lbs / 20 ft = 25 lbs/ft Working Load: The total load supported by the cable tray, uniformly
distributed. This will be the combined weight of all of the cables or tray
The Total Working Load will be the combination of all 3 loads, expressed in lbs/ft: contents, any environmental loads (snow, ice, dust) and any
Cables 40 lbs/ft concentrated static loads.
Snow + 15 lbs/ft Support Span: The maximum distance between the tray supports.
Concentrated Load + 25 lbs/ft NEMA Load Classes: A number (support span in feet) combined
Total Working Load: 80 lbs/ft with a letter (load capacity: A=50, B=75 and C=100 Lbs/Ft). Defined in
the National Electrical Manufacturers Assoc. NEMA Standard VE1.
Refer to the chart on the right. With a support span of 20’ and a total working load of
80 lbs/ft, a NEMA Class 20B tray rated at 75 lbs/ft will not be adequate. A NEMA CSA Load Classes: A single letter (A,B,C,D,E) designates the
Class 20C tray, rated at 100 lbs/ft, will be required. support span and load capacity per Canadian Standards Association
CSA Standard C22.2, No. 126.
Catalog Numbers for Horizontal and Vertical Elbows, Standard Horizontal Tees and Crosses
Material A - Aluminum
Catalog Numbers for Reducer Fittings, Reducing and Expanding Tees, Reducing Crosses
Material A - Aluminum
RS
W2
RADIUS SQUARE
ITEM CODE ITEM CODE ITEM CODE ITEM CODE LEFT-HAND
W1
90H 60H 45H 30H LEFT-HAND
REDUCER
WYE - LEFT WYE - RIGHT WYE ADJUSTABLE ITEM CODE
STRAIGHT ELBOW RL
W2
ADJUSTABLE
ANGLE RIGHT-HAND
W1
45o 45 o 45o 45o RIGHT-HAND
• No Radius REDUCER
• Max. 35 Degree Bend
ITEM CODE
ITEM CODE ITEM CODE ITEM CODE ITEM CODE
RR
HYL HYR HYS HAE W2
W2
• Can be customized with W2
special widths and radius
DROPOUT CROSS DOWN
W2
SQUARE
RADIUS VERTICAL DROPOUT STANDARD REDUCING EXPANDING
CROSS CROSS W1 = W2 W1 > W2 W1 < W2
CROSS TYPE ITEM CODE TYPE
ITEM CODE ITEM CODE
STANDARD
CROSS W1 = W2 HC DOWN DCD DCDR DCDE
REDUCING VC
CROSS
W1 < W2 HCR UP DCU DCUR DCUE
VERTICAL ELBOWS
o o o o
90 60 45 30
DIVIDERS
VERTICAL ELBOW
Standard: Supplied with (2) #10
self-drilling, stainless steel screws
STRAIGHT STRAIGHT - HEAVY DUTY HORIZONTAL FLEXIBLE Heavy-Duty: Includes holes for
Supplied with (4) #10 self- Includes holes for installation with U-Bolt Supplied with (3) #10 self- installation with U-Bolt Divider
drilling, stainless steel screws Divider Clamps (ordered separately) drilling, stainless steel screws Clamps (ordered separately)
Straight & Flexible Catalog Numbers: Vertical Elbow Divider Catalog Numbers: DIVIDER SPLICE
Example: DS - A6 - 12 Example: DF - A6 - 45VO24 5"
U-BOLT DIVIDER CLAMP KIT CABLE BRIDGE FOR DIVIDED TEES AND CROSSES
• Heavy-duty for high winds
• Provides support for vertical cable CATALOG NO. EACH
• Install on 36" - 48" centers separation where cables cross in
(Same as tek screws in
standard configuration)
divided Horizontal Tees and Crosses CB - A(H)*-(W )*-(L )*
• Dimensions can be customized to
• Includes U-Bolt, alum. plate
and (2) 1/4" flanged hex nuts 20" meet specific project requirements (H )* Insert tray side rail height
• Bolt and nuts are type 316 • Includes (6) #10 x 1" long self- in inches (4, 5, 6, 7, 8)
Stainless Steel W drilling, stainless steel screws (W )* Insert Bridge width in inches
• Standard height B is typically (03, 4.5, 06, 09, 12, 15, 18, 24, 30)
CATALOG NO. EA. B ½ of the tray interior load depth (L )* Insert Bridge length in inches
DHC-A-S W + 1.5" • Standard length (L)* is typically 20" (05, 08, 12, 18, 20, 24, 27, 30, 36)
COVERS
o
Flat, Non-Flanged, Flat, Flanged, Flat, Non-Flanged, Flat, Flanged, Peaked 20 ,
Solid Solid Ventilated Ventilated Flanged, Solid
Material Cover Item Length Width Thickness Material Cover Item Radius Width Thickness Side Rail
System Code Standard: 06 - 6" 040 - 0.040" System Code 00 - Square 06 - 6" 040 - 0.040" Height
AC FNS (Standard) AC 12 - 12" 09 - 9" (Standard)
Aluminum
SL 06 - 6'-0" 09 - 9"
Alternates: Aluminum
FNS Fitting
12 - 12" Alternates:
For Outside
Vertical
Item 24 - 24"
Cover
FFS Straight 12 - 12'-0" 12 - 12" Cover
FFS 18 - 18" Elbows
063 - 0.063" 36 - 36" 063 - 0.063"
FNV Length Non-standard
18 - 18" FNV Code OR
24 - 24" Only;
24 - 24" 080 - 0.080" 30 - 30" 080 - 0.080" Leave
lengths are FFV
FFV available; 090 - 0.090" Pages Reducer 36 - 36" 090 - 0.090" Blank For
30 - 30" Width W1
PFS consult factory 125 - 0.125" PFS 4&5 OR 125 - 0.125" All Other
for lead times 36 - 36" Reducer Fittings
188 - 0.188" 188 - 0.188"
Width W2
COVER CONNECTORS
COVER CLAMPS Cover Clamp Catalog Numbers: COVER CLIPS
OUTDOOR OR VERTICAL USE INDOOR AND
Example: CFS - A6 - 18 - S HORIZONTAL USE
FLAT STANDARD
STRAP Item Material Side Rail Width Hardware
Code A Height 06 - 6" Material COVER CLIP
ITEM CODE
Aluminum 4 - 4" High 09 - 9"
Clamp S - Stainless
CFS Item 5 - 5" High 12 - 12" Steel 316
6 - 6" High 18 - 18" (Standard
Code 24 - 24" Hardware
7 - 7" High
PEAKED 30 - 30" Material)
8 - 8" High
STRAP 36 - 36"
• Indoor Use Only
ITEM CODE
RECOMMENDED QUANTITY • 18-8 Stainless Steel
QUANTITY Clip and Screw
CPS OF COVER CONNECTORS
STANDARD CLAMPS CATALOG NO. EACH
GAP COVER TYPE
CLIPS
ELEVATED CCS-S
COVER STRAIGHT SECTION 6'L 4 2
CLAMP
STRAIGHT SECTION 12'L 6 3
ITEM CODE
ELBOWS 4 2
RAISED COVER CLIP
CCE- (†)* TEES 6 3
(†)* Specify Gap = 1", 2", 3", 4" CROSSES 8 4
GAP
16"
HORIZONTAL VERTICAL
S Only 16"
TRAYS TRAYS
ITEM CODE ITEM CODE ITEM CODE ITEM CODE For odd ITEM CODE ITEM CODE ITEM CODE ITEM CODE
angle
bends
SPS SPE SPM SPV up to 30o SPH SPB SHH SVH
All Splice Plates (except reducing) are Splice Plate & Connector Catalog Numbers:
supplied in pairs. Geomet-plated steel OFFSET R*
hardware is supplied with all splices and
connectors. Type 316 stainless steel
Example: SPS - A7 - G4 REDUCING
hardware is optional.
Standard Splice Plates are automatically Supplied each,
included with all straight tray sections and Item Material Side Rail Hardware Hardware not in pairs
fittings. Extras for field cuts or spares should Code A Height Finish Quantity
(†)* Insert Reduction
be ordered separately. Splice or Aluminum 4 - 4" High G - Geomet 4 - (4) Screws
Bonding Jumpers are required for use only 5 - 5" High
per plate ITEM CODE in inches (R)* = 1.5,
Connector
6 - 6" High S 3, 4.5, 6, 7.5, 9, 10.5,
with expansion connectors and at - Stainless 8 - (8) Screws
discontinuities in the tray system. Bonding
Item
7 - 7" High
Steel 316 per plate, SPR- (†)* 12, 13.5, 15, 18, 21,
jumpers are not required for use with vertical Code Fitting Class
24, 27, or 30
or horizontal adjustable connectors. 8 - 8" High 3 Only
STEP-DOWN CONVERSION
(REDUCING HEIGHT) PLATE BRANCH PIVOT
CONNECTORS
4/O 1600 GBJ-C-1600 3/O thru 250 MCM GWS-S-2-(F )* CATALOG NO. EA. CATALOG NO. EA.
250 2000 GBJ-C-2000 300 thru 500 MCM GWS-S-3-(F )* GWC-A1-Z GWL-A-Z
Bracket
Bracket + Clamp
• Aluminum Bracket
• *Specify conduit type (D)* = R for Rigid, E for EMT
• Aluminum • Zinc plated steel • *Specify conduit size in inches (†)*=
• 3/8" tray attachment hardware included • Use with 1/2" threaded rod .5, .75, 1, 1.25, 1.5, 2, 2.5, 3, or 4
• 1/2" support attachment hardware not included • Order 1/2" threaded rod and • *Specify Tray Fitting Class (C)* = 1, 2, 3 or 4
hex nuts separately
CATALOG NO. EA. CATALOG NO. EACH
CATALOG NO. EACH
2 HOLES HBT-A- ( F ) * Bracket Only CAB-( C )*- ( F )*
HRC-Z ( H )* - ( C )*
4 HOLES HBF-A- ( F ) * Clamp + Bracket CAC-(D†)*-(C)*-(F )*
(H )* Insert tray height in inches
(F )* Insert G or S (C)* Insert Fitting Class = 1, 2 or 3 (F )* Insert Z or S for clamp & fastener material
ACCESSORIES
RAIN HOOD FOR WALL PENETRATION SLEEVE Wall Penetration Sleeve
(Ordered Separately)
• Cover attaches to Wall Penetration Sleeve Wall
Indoor Tray
Hold-Down Strap
• Top of outdoor tray attaches to bottom of (2 pcs. included)
sleeve to create downhill "Drip Loop" in cables
Cable Dropout Plate
and prevent water from seeping into building (Included)
• Aluminum materials 30"
• Fasteners are stainless steel type 316
• Rain Hood attaches independently
of tray and sleeve assembly
CATALOG NUMBER EACH
Center Light SKCL-A-( Z or S )-( 38 or 12 ) 2 2 (1/4") 2 (1/4") 1 (3/8" or 1/2") 2 (3/8" or 1/2")
Hung Heavy SKCH-A-( Z or S )-( 38 or 12 ) 2 2 (3/8") 2 (3/8") 1 (3/8" or 1/2") 2 (3/8" or 1/2")
38 = 3/8", 12 = 1/2" Hardware for use with 3/8" or 1/2" threaded rod Chart above shows quantities of each item included in kits, supplied in plastic bags.
1.75"
• U.L. Certified load capacities SOLID ACHS 12' 0.60 in2 1,000 8AA 48 27 17 12
4" 1.75"
• NEMA, CSA and NEC Compliant VENTED ACHV 12' 0.40 in 2
600 8AA 48 27 17 12
• Necessary Splice Plates with SOLID ACHS 12' 0.60 in2 1,000 8AA 48 27 17 12
hardware are included with all 6" 1.75"
straight sections and fittings VENTED ACHV 12' 0.60 in 2 1,000 8AA 48 27 17 12
Pre-punched round holes Large round holes for cable CHANNEL CATALOG NO.
for Splice Plate connections dropouts and ventilation accept WIDTH (EACH)
Cable Bushings for cable protection
3" SB-P-1.25
Channel Hole Pattern Details (Pattern Repeats on 12" Centers)
4" & 6" SB-P-2
CHANNEL FITTINGS
Material: All channel fittings are aluminum alloy
5052 with arc-welded construction. Catalog Numbers for Channel Fittings
Channel Bottoms: Fittings are available in solid
and ventilated designs. Example: ACHV - 175 - 90H24 - 04 - S
Tangents: All fittings have 3" tangents (flats) at the
end of all curved side rails to accommodate splice
plate connectors. Channel Depth Radius Width Hardware
Channel Item
Radius: Standard 12”, 24” and 36” radius are 175 - 1-3/4" 12 - 12" 03 - 3" Finish
System Code
available for all fittings. 48” radius and other Number 24 - 24" 04 - 4" G - Geomet
custom designs are also available, consult factory. Insert 2, 3,
or 4-digit 36 - 36" 06 - 6" Plated
ACHV - Ventilated Steel
Splice Plates: All elbows are supplied with one Item Code
standard splice plate with hardware at no charge. ACHS - Solid to specify S - Stainless
Tee fittings include 2 and crosses include 3 Fitting type Steel 316
connectors with hardware at no charge.
o o o o
90 60 45 30 TEE CROSS
CHANNEL DIVIDERS
Straight & Flexible Catalog Numbers: Vertical Elbow Divider Catalog Numbers: DIVIDER SPLICE
Example: DSC-A175-12 Example: DFC - A175 - 45VO24 5"
S Only
ITEM CODE ITEM CODE ITEM CODE ITEM CODE For odd ITEM CODE ITEM CODE
angle
bends
SPW SPE SPV SPH up to 90o SPB CTC
All Splice Plates for Channel are supplied in Splice Plate & Connector Catalog Numbers:
single units, not in pairs. Geomet-plated REDUCING
steel hardware is supplied with all splices
and connectors. Type 316 stainless steel
Example: SPW - AC4 - G4 SPLICES
hardware is optional.
Standard Splice Plates are automatically WIDTHS CATALOG NO. EACH
included with all straight Channel sections Item Material Channel Hardware Hardware
Code AC Width Finish Quantity
and fittings. Extras for field cuts or spares 4" TO 3" SPR-AC43- ( F )* 4
should be ordered separately. Splice or Aluminum 3 - 3" Wide G - Geomet 4 - 4 Screws
Bonding Jumpers are required for use only Connector Channel 4 - 4" Wide
per plate 6" TO 3" SPR-AC63- ( F )* 4
with expansion connectors and at 6 - 6" Wide S - Stainless
discontinuities in the tray system. Bonding
Item Steel 316 6" TO 4" SPR-AC64- ( F )* 4
jumpers are not required for use with vertical Code
or horizontal adjustable connectors. (F )* Insert G or S
CHANNEL COVERS
o
Flat, Flanged, Solid Flat, Flanged, Ventilated Peaked 20 , Flanged, Solid
Material Cover Item Length Width Thickness Material Cover Item Radius Width Thickness
System Code Standard: 03 - 3" 040 - 0.040" System Code 12 - 12" 03 - 3" Blank - 0.040"
ACC (Standard)
ACC (Standard)
FFS SL 10 - 10'-0" 04 - 4" FFS Fitting 24 - 24" 04 - 4"
Aluminum Alternates: Aluminum Alternates:
FFV 12 - 12'-0" 06 - 6" FFV Item 36 - 36" 06 - 6"
Channel Straight 063 - 0.063" Channel 063 - 0.063"
Cover PFS Length Non-standard Cover PFS Code
080 - 0.080" 080 - 0.080"
lengths are
available; 090 - 0.090" Pages 090 - 0.090"
consult factory 125 - 0.125" 1&2 125 - 0.125"
for lead times
188 - 0.188" 188 - 0.188"
COVER CLAMPS - FLAT COVERS COVER CLAMPS - PEAKED COVERS COMBINATION COVER
CLAMP & HOLD-DOWN
WIDTH CATALOG NO. EACH WIDTH CATALOG NO. EACH
CATALOG NO. EA.
3" CFS-AC-03-S 3" CPS-AC-03-S
HDC-AC
4" CFS-AC-04-S 4" CPS-AC-04-S
6" CFS-AC-06-S 6" CPS-AC-06-S •Hole sized for 1/2" fasteners
•Fasteners ordered separately
• Aluminum with 1/4" Dia. Stainless Steel Fasteners • Aluminum with 1/4" Dia. Stainless Steel Fasteners
*Optional: For hole sized for 1/4" or 3/8"
• Suitable for Outdoor and Vertical Use • Suitable for Outdoor and Vertical Use fasteners, insert catalog no. suffix "-14" or "-38".
CHANNEL ACCESSORIES
SUPPORT CLAMPS MOUNTING BRACKET FLOOR BASE PLATE BLIND END
• Aluminum
•Hole sized for 1/2" fasteners • Aluminum • Fasteners included for • Aluminum
•Fasteners ordered separately • Fasteners Included Channel attachment only • Fasteners Included
CLAMP TYPE CAT. NO. EACH WIDTH CATALOG NO. EACH WIDTH CATALOG NO. EACH WIDTH CATALOG NO. EACH
HOLD DOWN
CLAMP HDZ-AC 3" CMB-AC3- ( F )* 3" CFB-AC3- ( F )* 3" BE-AC3- ( F )*
EXPANSION 4" CMB-AC4- ( F )* 4" CFB-AC4- ( F )* 4" BE-AC4- ( F )*
GUIDE CLAMP HDE-AC
6" CMB-AC6- ( F )* 6" CFB-AC6- ( F )* 6" BE-AC6- ( F )*
*Optional: For hole sized for 1/4" or
3/8" fasteners, insert catalog number
suffix "-14" or "-38". (F )* Insert Fastener Material: G Steel, Geomet Plated or S Stainless Steel, Type 316
• Aluminum
• Hang from ½" Threaded Rod • Aluminum • Aluminum • Aluminum
or Mount on Wall • 8" Wide for 3" & 4" Channels • 8" Wide for 3" & 4" Channels • Hang from ½" Threaded Rod
• Fasteners, Clamps and Rods • 10" Wide for 6" Channels • 10" Wide for 6" Channels • Fasteners, Clamps and Rods
Not Included • No Fasteners Included • No Fasteners Included Not Included
CHANNEL CATALOG NO. CHANNEL CATALOG NO. CHANNEL CATALOG NO. WIDTH CATALOG NO. EACH
WIDTH (EACH) WIDTH (EACH) WIDTH (EACH)
3" ACHD-A-03
3" & 4" ACHS-A-03-04 3" & 4" WBSC-A-08 3" & 4" WBC-A-08 4" ACHD-A-04
6" ACHS-A-06 6" WBSC-A-10 6" WBC-A-10 6" ACHD-A-06
IF
HIGH VOLTAGE
ISO
IED
9
560 Wharton Circle
IF
I SO
IE
Suite E
D
Atlanta, GA 30336
Phone: 404-696-8585 USTRAY
Fax: 404-696-8599
ustray.com
June 2017