MAX DIMENSIONS FOR DISCONNECTS

1034" *

9
716 "*

PREFERRED
1' - 638" *

1' - 0" *

4'-4"

4" DUCT COVER 100 amp DISCONNECT 60 amp DISCONNECT

NOTES: SQUARE D DISCONNECTS OR EQUIVILENT

1'-8" WALL
TO WALL
ACCESS
COVER
DISCONNECT SWITCH (BY OTHERS)

(FRONT)
10% - 95% NON-CONDENSING RELATIVE HUMIDITY

* DISCONNECTS LARGER THAN THESE PROVIDED DIMENSIONS, SUCH AS


DISCONNECTS WITH AN ELEVATOR SHUNT TRIP COULD INCREASE

3'-6" CLEAR
MINIMUM CONTROL ROOM DIMENSIONS.
DISCONNECT SWITCH,ABOVE CAR
LIGHT AND ALARM CIRCUIT WITH MACHINE DATA
SEPARATE DISCONNECT SWITCH
(STACKED) MACHINE
SUPPORT AND DISCONNECTS VOLTAGE
BY OTHERS
CAR SPEED
DRIVE H.P. **
HEAT LOAD
MACHINE
w/o TRANSFORMER
2'-111" 11 6" .
8 1 EQ w/ TRANSFORMER
)R

2"
1" REGENERATIVE DRIVE
2'-98 (8

CONTROL ROOM DATA


1'

NOTES: 7'-6" MIN. CEILING HEIGHT


MACHINE ROOM MUST BE CONDITIONED TO MAINTAIN TEMPERATURE
3'-61"

3'-4"

7'-6" MIN.
8

CONTROLLER ASSY. CONTROLLER ASSY.


1'

EXCEED 95% NON-CONDENSING

7' DOOR
(400 LBS.) (400 LBS.)

8"
5'-93
ONE, 6" WIDE X 6" HIGH ELECTRICAL RACEWAY REQUIRED. LOCATION IS
DETERMINED BY RELATIONSHIP BETWEEN CONTROL ROOM AND
1'

HOISTWAY. FINAL LOCATION TO BE VERIFIED BY THE FIELD


SUPERINTENDENT.

THE MINIMUM SIZES SHOWN FOR THESE CONTROL SPACES ARE


HEAT PREDICATED ON AVERAGE SIZED COMPONENTS AND ANY OVERSIZED
1"

DEFLECTOR
38

BOX OR DISCONNECT COULD AFFECT THE SIZE OF THE CONTROL ROOM.

6"
1"

1"
2'-34

2'-34

RESISTOR
CABINET THE PREFERRED LOCATION OF CONTROL ROOM SHOULD BE LOCATED AT
BOLT PATTERN FOR THE UPPER MOST LANDING AND THE MAXIMUM DISTANCE RUN OF
WALL MOUNTED CONTROLLER CONDUIT FROM CONTROLLER TO MACHINE IS 160'.

6"
4' CLR. OPNG.

4'-4"
WALL MOUNTED CONTROLLER

THIS STANDARD ARRANGEMENT IS TO BE USED WITH NO ADDITIONAL OPTIONS


AND A FEEDER VOLTAGE OF 208/240 OR 460/480 V

DELAWARE ELEVATOR
MANUFACTURING
PROJECT:
CONTROL CLOSET STANDARD RAIL SUPPORTED
LOCATION:

DRAWN BY : DATE : SCALE :

CONTRACT : SHEET :
NO. DATE BY REVISIONS 1 of 1