You are on page 1of 74

Providing power and lighting facility for renovation of SSD building ECIL, Hyderabad

ESD_ELEC-588
S.No PLNO (Item Description Quantity
1 1.1 Supply and installation of sheet steel flush mounted double door type three phase 7.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 160A, 12-way TPN DPX MCCB DB (Cat No: 5077
48)Make: Legrand / L&T / Siemens / Schneider

2 1.2 Supply and installation of sheet steel flush mounted double door type three phase 10.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 8-Way VTPN DB (5077 27)Make: Legrand / L&T /
Siemens / Schneider

3 1.3 Supply and installation of sheet steel flush mounted double door type three phase 3.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 4-Way VTPN DB (5077 25)Make: Legrand / L&T /
Siemens / Schneider

4 2.1 Supply and installation of sheet steel flush mounted double door type single phase 2.000
distribution board with phase and neutral to install on wall / column including MS
angular frame work with necessary accessories, internal wiring, earthing, painting,
numbering, and minor civil works etc., complete. 8-Way SPN DB (Cat No. 5076
11)Make: Legrand / L&T / Siemens / Schneider

5 3.1 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 7.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 160A DPXMCCB (Cat No: 4200 17) Make:
Legrand / L&T / Siemens / Schneider

6 3.2 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 10.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A FPMCB (Cat No: 4087 02)Make: Legrand /
L&T / Siemens / Schneider

7 3.3 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 10.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A RCCB (Cat No: 4118 88)Make: Legrand /
L&T / Siemens / Schneider

8 3.4 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 24.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A TPMCB (Cat No: 4086 61)Make: Legrand /
L&T / Siemens / Schneider
9 3.5 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 24.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 32A TPMCB (Cat No: 4086 58)Make: Legrand /
L&T / Siemens / Schneider

10 3.6 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 2.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 40A DPMCB (Cat No. 4086 37)Make: Legrand /
L&T / Siemens / Schneider

11 3.7 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 288.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge.10/20/32A SPMCBs (Cat No: 4085
90/93/95)Make: Legrand / L&T / Siemens / Schneider

12 4 Supply and Installation of 32 A TPN 5 pin plug & socket P17 Tempra model (Cat 10.000
No.5078 62) with 40A, 100ma FPRCCB (Cat No.4118 82) to install on DB with
suitable knock out for incoming cables to draw the three phase power supply
including MS frame work to fix on wall / column with required fasteners, earthing,
painting, numbering and minor civil works etc., complete. Make: Legrand / L&T /
Siemens / Schneider

13 5 Supply and Installation of 250 V grade 3-pin metal clad protected weather proof 20.000
plug socket, housed in Legrand MS box with 20A socket (Cat No.5078 14) with
plug top controlled by 20A DPRCCB (Cat No.4118 56) including earthing, neutral
link internal wiring, painting and numbering etc., complete to fix on suitable MS
bracket / frame work to wall / column as detailed. Make: Legrand / L&T / Siemens /
Schneider

14 6.1 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 2-Way
6/16A Modular Power socket controlled by 2 Nos of 16A Modular switch.
Make: North West / Legrand / L&T/Schneider

15 6.2 Supply and installation of following modular type plug sockets with Modular type 30.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 4-Way
6A Modular Power sockets controlled by 4Nos of 6A Modular switches. Make:
North West / Legrand / L&T/Schneider

16 6.3 Supply and installation of following modular type plug sockets with Modular type 30.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 3-Way
6A Modular Power socket controlled by 2 Nos of 6A Modular switch. Make:
North West / Legrand / L&T/Schneider

17 6.4 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 6A
Modular Power socket controlled by 6A Modular switchMake: North West /
Legrand / L&T/Schneider
18 6.5 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 16A
Modular Power socket controlled by 16A Modular switch.Make: North West /
Legrand / L&T/Schneider

19 7 Supply and installation of 600mmX600mm recessed type 34-40W LED false 230.000
ceiling lighting fixtures with LEDs mounted symmetrically inside the fitting and with
equal distribution of light including control circuitry duly wired to operate at 150-
290VAC, 50Hz to be fixed to beam / ceiling / on false ceiling including supply of all
necessary clamps supports, chains, pipes, fasteners, ball & sockets where
needed and earthing etc., complete Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VINLEDs: OSRAM/ Nichia / Cree

20 8 Supply and Installation, testing and commissioning of 4feet industrial box type 100.000
LED lighting fixture of 20-22 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete. Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

21 9 Supply and Installation, testing and commissioning of 4 feet industrial box type 100.000
LED lighting fixture of 36-40 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete.Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

22 10 Supply and Installation of high speed 1400mm sweep ceiling fan capacitor type 60.000
suitable to operate on 230 volts AC supply with blades, down rod, top and bottom
canopies to ISS 374/1979 double ball bearing including Northwest make electronic
step type speed control regulator and necessary fan hook to fix to ceiling / beam
with required accessories and fasteners etc., complete. Make: Crompton (High
speed HSD-1400mm)/Bajaj/Orient

23 11 Supply and installation of 400mm sweep oscillating type wall mounted fan suitable 30.000
to operate on single phase 230V 50Hz AC supply to be installed on Wall / Column
with required MS frame work, wiring and necessary civil works etc., complete.
Make: Orient / Bajaj / Almonard

24 12.1 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 500.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete. 5
X 6 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells
25 12.2 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 3000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 4 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

26 12.3 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 4000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

27 12.4 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 3000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel
/Lapp/Bonton/Havells

28 12.5 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 4000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 1.5 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

29 12.6 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 500.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 10 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

30 13.1 Supply of following 1100V grade XLPE insulated PVC sheathed armoured heavy 400.000
duty copper conductor Cables of approved make conforming to IS-7098 (Part-I)
specifications. 4 core, 10 Sq.mm Copper cableMake: Finolex / L&T / KEI /
Universal

31 14.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 80.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply
of all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling one light / Fans.Make:
Finolex/L&T (wires) & North West / Legrand / L&T Switches. Conduit:
Sudhakar/VIP/Precision
32 14.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of
all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling two lights.Make: Finolex/L&T
(wires) & North West / Legrand / L&T Switches. Conduit: Sudhakar/VIP/Precision

33 15.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 20.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling one light / Fans.Make: Finolex/L&T (wires) &
North West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

34 15.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 100.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling two lights.Make: Finolex/L&T (wires) & North
West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath
35 16.1 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling one
light / Fans.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches

36 16.2 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling two
lights.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches

37 17.1 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 4000.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 25 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

38 17.2 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 2000.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 20 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

39 18.1 Supply and fixing of following communication outlet sockets to be mounted in a 25.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ11 telephoneMake: Northwest/ Legrand / L&T
40 18.2 Supply and fixing of following communication outlet sockets to be mounted in a 25.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ 45 LAN (CAT-6)Make: Northwest/ Legrand / L&T
41 19.1 Supply and Installation of krone connector type telephone distribution box in sheet 2.000
steel enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with
castle key lock, hinged gasketed type cover and connected fasteners etc.,
complete 50 Pair DB box

42 20.1 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 500.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 20 pair
PVC Telephone cablesMake: Finolex / Delton

43 20.2 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 1000.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 04 pair
PVC Telephone cablesMake: Finolex / Delton

44 21.1 Supply and fixing of following Modular convex type cover plate to be fixed on 50.000
modular furniture / GI Metal box on walls / Columns. 2-Modular cover plateMake:
Northwest/ Legrand / L&T

45 22 Supply and Installation of Two-Module modular metal enclosure boxes including 50.000
fixing in the wall surface / recess, modular furniture with minor civil works
etc,Make: Northwest/ Legrand / L&T.
46 23 Supply, Installation, Testing & Commissioning of new Earth pits as per IS 3043 10.000
with UL Listed 3/4 copper bonded steel rod of 3 Mtrs long, scope of work
includes all civil works like excavation of pit (3 Mtrs depth), backfilling the pit with
Carbon based chemical Ground Enhancement material of 22.5KG to be supplied
by the contractor including construction of chamber for the pit, frame around the
pit, supply of pit cover, measurement of earth pit resistance complete as per the
instructions of Engineer In-charge. Make: DEHN / ABB / Infinity

47 24 ANTI - STATIC EARTH TERMINALS: i) Supply and installation of 200mm in 25.000


length, 25mm width and 3mm thick soft drawn hot dipped Tin coated Copper strip
with porcelain bases as supports of suitable size with provision for tapping from
the strip including chromium coated hardware to fix on wall / column at the height
of 0.5 Mtr from floor level with anti-static indicator including supply of necessary
accessories, welding, bending, drilling and minor civil works etc., complete as per
instructions of Engineer In-charge.

48 25.1 Supply and laying of hot dip GI /Copper strip / wire as under including 1000.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. 25 x 3 mm G.I strip

49 25.2 Supply and laying of hot dip GI /Copper strip / wire as under including 300.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. N0.8 SWG G.I wire
50 26.1 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.450 x62.5 x2mm cable Tray

51 26.2 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 450X62.5mm above size with 2mm
thickness

52 26.3 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.150 x50 x1.6mm cable Tray

53 26.4 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 150X50mm size with 2mm
thickness

54 27.1 Removals of old electrical fittings: Ceiling fans 40.000


55 27.2 Removals of old electrical fittings: Tube light fixtures 80.000
56 27.3 Removals of old electrical fittings: Switch boards with MS box 30.000
57 27.4 Removals of old electrical fittings: Metal clad sockets with MS box 30.000
58 27.5 Removals of old electrical fittings: MS / PVC pipes along with wires 300.000
59 27.6 Removals of old electrical fittings: Armoured cables 100.000
Total

Estimated Cost

Quote Percent
ng ECIL, Hyderabad

Unit Rate Amount


Each 15027.00 105189.00

Each 9696.00 96960.00

Each 7637.00 22911.00

Each 2008.00 4016.00

Each 7961.00 55727.00

Each 1897.00 18970.00

Each 3585.00 35850.00

Each 1504.00 36096.00


Each 986.00 23664.00

Each 972.00 1944.00

Each 215.00 61920.00

Each 6840.00 68400.00

Each 3667.00 73340.00

Each 1081.00 75670.00

Each 1542.00 46260.00

Each 1242.00 37260.00

Each 459.00 32130.00


Each 585.00 40950.00

Each 3292.00 757160.00

Each 2990.00 299000.00

Each 3255.00 325500.00

Each 2393.00 143580.00

Each 1623.00 48690.00

Metre 262.00 131000.00


Metre 71.00 213000.00

Metre 49.00 196000.00

Metre 25.00 75000.00

Metre 16.00 64000.00

Metre 95.00 47500.00

Metre 349.00 139600.00

Each 929.00 74320.00


Each 1211.00 60550.00

Each 1163.00 23260.00

Each 1622.00 162200.00


Each 660.00 33000.00

Each 951.00 47550.00

Metre 78.00 312000.00

Metre 61.00 122000.00

Each 225.00 5625.00

Each 573.00 14325.00


Each 4200.00 8400.00

Metre 119.00 59500.00

Metre 49.00 49000.00

Each 79.00 3950.00

Each 92.00 4600.00

Each 18500.00 185000.00

Each 214.00 5350.00

Metre 75.00 75000.00

Metre 15.00 4500.00


Metre 944.00 47200.00

Metre 894.00 44700.00

Metre 376.00 18800.00

Metre 420.00 21000.00

Each 100.00 4000.00


Each 100.00 8000.00
Each 60.00 1800.00
Each 75.00 2250.00
Metre 15.00 4500.00
Metre 25.00 2500.00
4,682,167.00

4,000,000.00

17.05%

Rs. 4,682,167.00
Providing power and lighting facility for renovation of SSD building ECIL, Hyderabad
ESD_ELEC-588
S.No
PLNO (Item Code) Item Description Quantity
1 1.1 Supply and installation of sheet steel flush mounted double door type three phase 1.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 160A, 12-way TPN DPX MCCB DB (Cat No: 5077
48)Make: Legrand / L&T / Siemens / Schneider

2 1.2 Supply and installation of sheet steel flush mounted double door type three phase 1.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 8-Way VTPN DB (5077 27)Make: Legrand / L&T /
Siemens / Schneider

3 1.3 Supply and installation of sheet steel flush mounted double door type three phase 1.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 4-Way VTPN DB (5077 25)Make: Legrand / L&T /
Siemens / Schneider

4 2.1 Supply and installation of sheet steel flush mounted double door type single phase 1.000
distribution board with phase and neutral to install on wall / column including MS
angular frame work with necessary accessories, internal wiring, earthing, painting,
numbering, and minor civil works etc., complete. 8-Way SPN DB (Cat No. 5076
11)Make: Legrand / L&T / Siemens / Schneider

5 3.1 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 160A DPXMCCB (Cat No: 4200 17) Make:
Legrand / L&T / Siemens / Schneider

6 3.2 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A FPMCB (Cat No: 4087 02)Make: Legrand /
L&T / Siemens / Schneider

7 3.3 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A RCCB (Cat No: 4118 88)Make: Legrand /
L&T / Siemens / Schneider

8 3.4 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A TPMCB (Cat No: 4086 61)Make: Legrand /
L&T / Siemens / Schneider
9 3.5 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 32A TPMCB (Cat No: 4086 58)Make: Legrand /
L&T / Siemens / Schneider

10 3.6 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 40A DPMCB (Cat No. 4086 37)Make: Legrand /
L&T / Siemens / Schneider

11 3.7 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 1.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge.10/20/32A SPMCBs (Cat No: 4085
90/93/95)Make: Legrand / L&T / Siemens / Schneider

12 4 Supply and Installation of 32 A TPN 5 pin plug & socket P17 Tempra model (Cat 1.000
No.5078 62) with 40A, 100ma FPRCCB (Cat No.4118 82) to install on DB with
suitable knock out for incoming cables to draw the three phase power supply
including MS frame work to fix on wall / column with required fasteners, earthing,
painting, numbering and minor civil works etc., complete. Make: Legrand / L&T /
Siemens / Schneider

13 5 Supply and Installation of 250 V grade 3-pin metal clad protected weather proof 1.000
plug socket, housed in Legrand MS box with 20A socket (Cat No.5078 14) with
plug top controlled by 20A DPRCCB (Cat No.4118 56) including earthing, neutral
link internal wiring, painting and numbering etc., complete to fix on suitable MS
bracket / frame work to wall / column as detailed. Make: Legrand / L&T / Siemens /
Schneider

14 6.1 Supply and installation of following modular type plug sockets with Modular type 1.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 2-Way
6/16A Modular Power socket controlled by 2 Nos of 16A Modular switch.
Make: North West / Legrand / L&T/Schneider

15 6.2 Supply and installation of following modular type plug sockets with Modular type 1.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 4-Way
6A Modular Power sockets controlled by 4Nos of 6A Modular switches. Make:
North West / Legrand / L&T/Schneider

16 6.3 Supply and installation of following modular type plug sockets with Modular type 1.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 3-Way
6A Modular Power socket controlled by 2 Nos of 6A Modular switch. Make:
North West / Legrand / L&T/Schneider
17 6.4 Supply and installation of following modular type plug sockets with Modular type 1.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 6A
Modular Power socket controlled by 6A Modular switchMake: North West /
Legrand / L&T/Schneider

18 6.5 Supply and installation of following modular type plug sockets with Modular type 1.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 16A
Modular Power socket controlled by 16A Modular switch.Make: North West /
Legrand / L&T/Schneider

19 7 Supply and installation of 600mmX600mm recessed type 34-40W LED false 1.000
ceiling lighting fixtures with LEDs mounted symmetrically inside the fitting and with
equal distribution of light including control circuitry duly wired to operate at 150-
290VAC, 50Hz to be fixed to beam / ceiling / on false ceiling including supply of all
necessary clamps supports, chains, pipes, fasteners, ball & sockets where
needed and earthing etc., complete Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VINLEDs: OSRAM/ Nichia / Cree

20 8 Supply and Installation, testing and commissioning of 4feet industrial box type 1.000
LED lighting fixture of 20-22 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete. Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

21 9 Supply and Installation, testing and commissioning of 4 feet industrial box type 1.000
LED lighting fixture of 36-40 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete.Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

22 10 Supply and Installation of high speed 1400mm sweep ceiling fan capacitor type 1.000
suitable to operate on 230 volts AC supply with blades, down rod, top and bottom
canopies to ISS 374/1979 double ball bearing including Northwest make electronic
step type speed control regulator and necessary fan hook to fix to ceiling / beam
with required accessories and fasteners etc., complete. Make: Crompton (High
speed HSD-1400mm)/Bajaj/Orient

23 11 Supply and installation of 400mm sweep oscillating type wall mounted fan suitable 1.000
to operate on single phase 230V 50Hz AC supply to be installed on Wall / Column
with required MS frame work, wiring and necessary civil works etc., complete.
Make: Orient / Bajaj / Almonard
24 12.1 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 1.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete. 5
X 6 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

25 12.2 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 1.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 4 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

26 12.3 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 1.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

27 12.4 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 1.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel
/Lapp/Bonton/Havells

28 12.5 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 1.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 1.5 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

29 12.6 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 1.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 10 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

30 13.1 Supply of following 1100V grade XLPE insulated PVC sheathed armoured heavy 1.000
duty copper conductor Cables of approved make conforming to IS-7098 (Part-I)
specifications. 4 core, 10 Sq.mm Copper cableMake: Finolex / L&T / KEI /
Universal
31 14.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 1.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply
of all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling one light / Fans.Make:
Finolex/L&T (wires) & North West / Legrand / L&T Switches. Conduit:
Sudhakar/VIP/Precision

Point Wiring
Conduit 3.900
Wire 9.450
Box 1.000
Cover Plate 1.000
Switch 1.000
Circuit Wiring
Conduit 3.900
Wire 2.5sq.mm 6.300
Wire 1.5sq.mm 3.150
Labour 1.000
OHP 0.150

32 14.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 1.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of
all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling two lights.Make: Finolex/L&T
(wires) & North West / Legrand / L&T Switches. Conduit: Sudhakar/VIP/Precision

Point Wiring
Conduit 7.800
Wire 18.900
Box 1.000
Cover Plate 1.000
Switch 1.000
Circuit Wiring
Conduit 3.900
Wire 2.5sq.mm 6.300
Wire 1.5sq.mm 3.150
Labour 1.000
OHP 0.150

33 15.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 1.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling one light / Fans.Make: Finolex/L&T (wires) &
North West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

Point Wiring
Conduit 3.900
Wire 9.450
Box 1.000
Cover Plate 1.000
Switch 1.000
Circuit Wiring
Conduit 3.900
Wire 2.5sq.mm 6.300
Wire 1.5sq.mm 3.150
Labour 1.000
OHP 0.150
34 15.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 1.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling two lights.Make: Finolex/L&T (wires) & North
West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

Point Wiring
Conduit 7.800
Wire 18.900
Box 1.000
Cover Plate 1.000
Switch 1.000
Circuit Wiring
Conduit 3.900
Wire 2.5sq.mm 6.300
Wire 1.5sq.mm 3.150
Labour 1.000
OHP 0.150

35 16.1 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 1.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling one
light / Fans.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches

Point Wiring
Conduit 0.000
Wire 9.450
Box 1.000
Cover Plate 1.000
Switch 1.000
Circuit Wiring
Conduit 0.000
Wire 2.5sq.mm 6.300
Wire 1.5sq.mm 3.150
Labour 1.000
OHP 0.150

36 16.2 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 1.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling two
lights.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches

Point Wiring
Conduit 0.000
Wire 18.900
Box 1.000
Cover Plate 1.000
Switch 1.000
Circuit Wiring
Conduit 0.000
Wire 2.5sq.mm 6.300
Wire 1.5sq.mm 3.150
Labour 1.000
OHP 0.150

37 17.1 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 1.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 25 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision
38 17.2 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 1.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 20 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

39 18.1 Supply and fixing of following communication outlet sockets to be mounted in a 1.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ11 telephoneMake: Northwest/ Legrand / L&T
40 18.2 Supply and fixing of following communication outlet sockets to be mounted in a 1.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ 45 LAN (CAT-6)Make: Northwest/ Legrand / L&T
41 19.1 Supply and Installation of krone connector type telephone distribution box in sheet 1.000
steel enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with
castle key lock, hinged gasketed type cover and connected fasteners etc.,
complete 50 Pair DB box

42 20.1 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 1.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 20 pair
PVC Telephone cablesMake: Finolex / Delton

43 20.2 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 1.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 04 pair
PVC Telephone cablesMake: Finolex / Delton

44 21.1 Supply and fixing of following Modular convex type cover plate to be fixed on 1.000
modular furniture / GI Metal box on walls / Columns. 2-Modular cover plateMake:
Northwest/ Legrand / L&T

45 22 Supply and Installation of Two-Module modular metal enclosure boxes including 1.000
fixing in the wall surface / recess, modular furniture with minor civil works
etc,Make: Northwest/ Legrand / L&T.
46 23 Supply, Installation, Testing & Commissioning of new Earth pits as per IS 3043 1.000
with UL Listed 3/4 copper bonded steel rod of 3 Mtrs long, scope of work
includes all civil works like excavation of pit (3 Mtrs depth), backfilling the pit with
Carbon based chemical Ground Enhancement material of 22.5KG to be supplied
by the contractor including construction of chamber for the pit, frame around the
pit, supply of pit cover, measurement of earth pit resistance complete as per the
instructions of Engineer In-charge. Make: DEHN / ABB / Infinity
47 24 ANTI - STATIC EARTH TERMINALS: i) Supply and installation of 200mm in 1.000
length, 25mm width and 3mm thick soft drawn hot dipped Tin coated Copper strip
with porcelain bases as supports of suitable size with provision for tapping from
the strip including chromium coated hardware to fix on wall / column at the height
of 0.5 Mtr from floor level with anti-static indicator including supply of necessary
accessories, welding, bending, drilling and minor civil works etc., complete as per
instructions of Engineer In-charge.

48 25.1 Supply and laying of hot dip GI /Copper strip / wire as under including 1.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. 25 x 3 mm G.I strip

49 25.2 Supply and laying of hot dip GI /Copper strip / wire as under including 1.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. N0.8 SWG G.I wire

50 26.1 Supply and Installation of following Perforated galvanized iron cable tray, 1.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.450 x62.5 x2mm cable Tray

51 26.2 Supply and Installation of following Perforated galvanized iron cable tray, 1.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 450X62.5mm above size with 2mm
thickness

52 26.3 Supply and Installation of following Perforated galvanized iron cable tray, 1.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.150 x50 x1.6mm cable Tray
53 26.4 Supply and Installation of following Perforated galvanized iron cable tray, 1.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 150X50mm size with 2mm
thickness

54 27.1 Removals of old electrical fittings: Ceiling fans 1.000


55 27.2 Removals of old electrical fittings: Tube light fixtures 1.000
56 27.3 Removals of old electrical fittings: Switch boards with MS box 1.000
57 27.4 Removals of old electrical fittings: Metal clad sockets with MS box 1.000
58 27.5 Removals of old electrical fittings: MS / PVC pipes along with wires 1.000
59 27.6 Removals of old electrical fittings: Armoured cables 1.000
Unit Rate Amount
Each 15026.54 15026.54

Each 9695.38 9695.38

Each 7636.52 7636.52

Each 2007.6 2007.60

Each 7960.5 7960.50

Each 1896.6 1896.60

Each 3584.34 3584.34

Each 1503.3 1503.30


Each 985.64 985.64

Each 971.84 971.84

Each 214.06 214.06

Each 6839.34 6839.34

Each 3666.08 3666.08

Each 1080.49 1080.49

Each 1541.04 1541.04

Each 1241.58 1241.58


Each 458.64 458.64

Each 584.91 584.91

Each 3291.2 3291.20

Each 2989.35 2989.35

Each 3255 3255.00

Each 2392.5 2392.50

Each 1622.881 1622.88


Metre 261.509 261.51

Metre 70.8797 70.88

Metre 48.5178 48.52

Metre 24.2589 24.26

Metre 15.2457 15.25

Metre 94.20918 94.21

Metre 348.45 348.45


Each 928.38 928.38

Metre 23.544 91.82


Metre 10.907 103.07
Each 44.4 44.40
Each 60 60.00
Each 70.8 70.80
0.00
Metre 23.544 91.82
Metre 17.6215 111.02
Metre 10.907 34.36
LS 200 200.00
% 807.29 121.09

Each 1210.01 1210.01

Metre 23.544 183.64


Metre 10.907 206.14
Each 44.4 44.40
Each 60 60.00
Each 70.8 70.80
0 0.00
Metre 23.544 91.82
Metre 17.6215 111.02
Metre 10.907 34.36
LS 250 250.00
% 1052.18 157.83

Each 1162.84 1162.84

Metre 63 245.70
Metre 10.907 103.07
Each 44.4 44.40
Each 60 60.00
Each 70.8 70.80
0 0.00
Metre 23.544 91.82
Metre 17.6215 111.02
Metre 10.907 34.36
LS 250 250.00
% 1011.17 151.67
Each 1621.43 1621.43

Metre 63 491.40
Metre 10.907 206.14
Each 44.4 44.40
Each 60 60.00
Each 70.8 70.80
0 0.00
Metre 23.544 91.82
Metre 17.6215 111.02
Metre 10.907 34.36
LS 300 300.00
% 1409.94 211.49

Each 659.69 659.69

Metre 63 0.00
Metre 10.907 103.07
Each 44.4 44.40
Each 60 60.00
Each 70.8 70.80
0 0.00
Metre 23.544 0.00
Metre 17.6215 111.02
Metre 10.907 34.36
LS 150 150.00
% 573.64 86.05

Each 950.72 950.72

Metre 63 0.00
Metre 10.907 206.14
Each 44.4 44.40
Each 60 60.00
Each 70.8 70.80
0 0.00
Metre 23.544 0.00
Metre 17.6215 111.02
Metre 10.907 34.36
LS 300 300.00
% 826.71 124.01

Metre 77.11925 77.12


Metre 60.8842 60.88

Each 224.57 224.57

Each 572.65 572.65

Each 4200 4200.00

Metre 118.6 118.60

Metre 48.92 48.92

Each 79 79.00

Each 91.06 91.06

Each 18500 18500.00


Each 213.9923 213.99

Metre 74.85 74.85

Metre 15 15.00

Metre 943.5 943.50

Metre 893.5 893.50

Metre 376 376.00


Metre 420 420.00

Each 100 100.00


Each 100 100.00
Each 60 60.00
Each 75 75.00
Metre 15 15.00
Metre 25 25.00
Providing power and lighting facility for renovation of SSD building ECIL, Hyderabad
ESD_ELEC-588
S.No PLNO (Item Description Quantity
1 1.1 Supply and installation of sheet steel flush mounted double door type three phase 7.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 160A, 12-way TPN DPX MCCB DB (Cat No: 5077
48)Make: Legrand / L&T / Siemens / Schneider

2 1.2 Supply and installation of sheet steel flush mounted double door type three phase 10.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 8-Way VTPN DB (5077 27)Make: Legrand / L&T /
Siemens / Schneider

3 1.3 Supply and installation of sheet steel flush mounted double door type three phase 3.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 4-Way VTPN DB (5077 25)Make: Legrand / L&T /
Siemens / Schneider

4 2.1 Supply and installation of sheet steel flush mounted double door type single phase 2.000
distribution board with phase and neutral to install on wall / column including MS
angular frame work with necessary accessories, internal wiring, earthing, painting,
numbering, and minor civil works etc., complete. 8-Way SPN DB (Cat No. 5076
11)Make: Legrand / L&T / Siemens / Schneider

5 3.1 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 7.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 160A DPXMCCB (Cat No: 4200 17) Make:
Legrand / L&T / Siemens / Schneider

6 3.2 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 10.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A FPMCB (Cat No: 4087 02)Make: Legrand /
L&T / Siemens / Schneider

7 3.3 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 10.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A RCCB (Cat No: 4118 88)Make: Legrand /
L&T / Siemens / Schneider

8 3.4 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 24.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A TPMCB (Cat No: 4086 61)Make: Legrand /
L&T / Siemens / Schneider
9 3.5 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 24.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 32A TPMCB (Cat No: 4086 58)Make: Legrand /
L&T / Siemens / Schneider

10 3.6 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 2.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 40A DPMCB (Cat No. 4086 37)Make: Legrand /
L&T / Siemens / Schneider

11 3.7 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 288.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge.10/20/32A SPMCBs (Cat No: 4085
90/93/95)Make: Legrand / L&T / Siemens / Schneider

12 4 Supply and Installation of 32 A TPN 5 pin plug & socket P17 Tempra model (Cat 10.000
No.5078 62) with 40A, 100ma FPRCCB (Cat No.4118 82) to install on DB with
suitable knock out for incoming cables to draw the three phase power supply
including MS frame work to fix on wall / column with required fasteners, earthing,
painting, numbering and minor civil works etc., complete. Make: Legrand / L&T /
Siemens / Schneider

13 5 Supply and Installation of 250 V grade 3-pin metal clad protected weather proof 20.000
plug socket, housed in Legrand MS box with 20A socket (Cat No.5078 14) with
plug top controlled by 20A DPRCCB (Cat No.4118 56) including earthing, neutral
link internal wiring, painting and numbering etc., complete to fix on suitable MS
bracket / frame work to wall / column as detailed. Make: Legrand / L&T / Siemens /
Schneider

14 6.1 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 2-Way
6/16A Modular Power socket controlled by 2 Nos of 16A Modular switch.
Make: North West / Legrand / L&T/Schneider

15 6.2 Supply and installation of following modular type plug sockets with Modular type 30.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 4-Way
6A Modular Power sockets controlled by 4Nos of 6A Modular switches. Make:
North West / Legrand / L&T/Schneider

16 6.3 Supply and installation of following modular type plug sockets with Modular type 30.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 3-Way
6A Modular Power socket controlled by 2 Nos of 6A Modular switch. Make:
North West / Legrand / L&T/Schneider
17 6.4 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 6A
Modular Power socket controlled by 6A Modular switchMake: North West /
Legrand / L&T/Schneider

18 6.5 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 16A
Modular Power socket controlled by 16A Modular switch.Make: North West /
Legrand / L&T/Schneider

19 7 Supply and installation of 600mmX600mm recessed type 34-40W LED false 230.000
ceiling lighting fixtures with LEDs mounted symmetrically inside the fitting and with
equal distribution of light including control circuitry duly wired to operate at 150-
290VAC, 50Hz to be fixed to beam / ceiling / on false ceiling including supply of all
necessary clamps supports, chains, pipes, fasteners, ball & sockets where
needed and earthing etc., complete Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VINLEDs: OSRAM/ Nichia / Cree

20 8 Supply and Installation, testing and commissioning of 4feet industrial box type 100.000
LED lighting fixture of 20-22 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete. Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

21 9 Supply and Installation, testing and commissioning of 4 feet industrial box type 100.000
LED lighting fixture of 36-40 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete.Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

22 10 Supply and Installation of high speed 1400mm sweep ceiling fan capacitor type 60.000
suitable to operate on 230 volts AC supply with blades, down rod, top and bottom
canopies to ISS 374/1979 double ball bearing including Northwest make electronic
step type speed control regulator and necessary fan hook to fix to ceiling / beam
with required accessories and fasteners etc., complete. Make: Crompton (High
speed HSD-1400mm)/Bajaj/Orient

23 11 Supply and installation of 400mm sweep oscillating type wall mounted fan suitable 30.000
to operate on single phase 230V 50Hz AC supply to be installed on Wall / Column
with required MS frame work, wiring and necessary civil works etc., complete.
Make: Orient / Bajaj / Almonard
24 12.1 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 500.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete. 5
X 6 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

25 12.2 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 3000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 4 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

26 12.3 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 4000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

27 12.4 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 3000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel
/Lapp/Bonton/Havells

28 12.5 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 4000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 1.5 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

29 12.6 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 500.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 10 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

30 13.1 Supply of following 1100V grade XLPE insulated PVC sheathed armoured heavy 400.000
duty copper conductor Cables of approved make conforming to IS-7098 (Part-I)
specifications. 4 core, 10 Sq.mm Copper cableMake: Finolex / L&T / KEI /
Universal
31 14.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 80.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply
of all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling one light / Fans.Make:
Finolex/L&T (wires) & North West / Legrand / L&T Switches. Conduit:
Sudhakar/VIP/Precision

32 14.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of
all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling two lights.Make: Finolex/L&T
(wires) & North West / Legrand / L&T Switches. Conduit: Sudhakar/VIP/Precision
33 15.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 20.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling one light / Fans.Make: Finolex/L&T (wires) &
North West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

34 15.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 100.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling two lights.Make: Finolex/L&T (wires) & North
West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

35 16.1 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling one
light / Fans.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches
36 16.2 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling two
lights.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches

37 17.1 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 4000.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 25 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

38 17.2 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 2000.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 20 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

39 18.1 Supply and fixing of following communication outlet sockets to be mounted in a 25.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ11 telephoneMake: Northwest/ Legrand / L&T
40 18.2 Supply and fixing of following communication outlet sockets to be mounted in a 25.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ 45 LAN (CAT-6)Make: Northwest/ Legrand / L&T
41 19.1 Supply and Installation of krone connector type telephone distribution box in sheet 2.000
steel enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with
castle key lock, hinged gasketed type cover and connected fasteners etc.,
complete 50 Pair DB box

42 20.1 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 500.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 20 pair
PVC Telephone cablesMake: Finolex / Delton

43 20.2 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 1000.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 04 pair
PVC Telephone cablesMake: Finolex / Delton
44 21.1 Supply and fixing of following Modular convex type cover plate to be fixed on 50.000
modular furniture / GI Metal box on walls / Columns. 2-Modular cover plateMake:
Northwest/ Legrand / L&T

45 22 Supply and Installation of Two-Module modular metal enclosure boxes including 50.000
fixing in the wall surface / recess, modular furniture with minor civil works
etc,Make: Northwest/ Legrand / L&T.
46 23 Supply, Installation, Testing & Commissioning of new Earth pits as per IS 3043 10.000
with UL Listed 3/4 copper bonded steel rod of 3 Mtrs long, scope of work
includes all civil works like excavation of pit (3 Mtrs depth), backfilling the pit with
Carbon based chemical Ground Enhancement material of 22.5KG to be supplied
by the contractor including construction of chamber for the pit, frame around the
pit, supply of pit cover, measurement of earth pit resistance complete as per the
instructions of Engineer In-charge. Make: DEHN / ABB / Infinity

47 24 ANTI - STATIC EARTH TERMINALS: i) Supply and installation of 200mm in 25.000


length, 25mm width and 3mm thick soft drawn hot dipped Tin coated Copper strip
with porcelain bases as supports of suitable size with provision for tapping from
the strip including chromium coated hardware to fix on wall / column at the height
of 0.5 Mtr from floor level with anti-static indicator including supply of necessary
accessories, welding, bending, drilling and minor civil works etc., complete as per
instructions of Engineer In-charge.

48 25.1 Supply and laying of hot dip GI /Copper strip / wire as under including 1000.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. 25 x 3 mm G.I strip

49 25.2 Supply and laying of hot dip GI /Copper strip / wire as under including 300.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. N0.8 SWG G.I wire

50 26.1 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.450 x62.5 x2mm cable Tray

51 26.2 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 450X62.5mm above size with 2mm
thickness
52 26.3 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.150 x50 x1.6mm cable Tray

53 26.4 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 150X50mm size with 2mm
thickness

54 27.1 Removals of old electrical fittings: Ceiling fans 40.000


55 27.2 Removals of old electrical fittings: Tube light fixtures 80.000
56 27.3 Removals of old electrical fittings: Switch boards with MS box 30.000
57 27.4 Removals of old electrical fittings: Metal clad sockets with MS box 30.000
58 27.5 Removals of old electrical fittings: MS / PVC pipes along with wires 300.000
59 27.6 Removals of old electrical fittings: Armoured cables 100.000
Total

Estimated Cost

Quote Percent
ng ECIL, Hyderabad

Unit Rate Amount


Each 14274.00 99918.00

Each 9217.00 92170.00

Each 7254.00 21762.00

Each 1908.00 3816.00

Each 7560.00 52920.00

Each 1800.00 18000.00

Each 3402.00 34020.00

Each 1422.00 34128.00


Each 936.00 22464.00

Each 927.00 1854.00

Each 207.00 59616.00

Each 6480.00 64800.00

Each 3420.00 68400.00

Each 972.00 68040.00

Each 1386.00 41580.00

Each 1116.00 33480.00


Each 414.00 28980.00

Each 522.00 36540.00

Each 2961.00 681030.00

Each 2691.00 269100.00

Each 2925.00 292500.00

Each 2151.00 129060.00

Each 1458.00 43740.00


Metre 234.00 117000.00

Metre 63.00 189000.00

Metre 45.00 180000.00

Metre 27.00 81000.00

Metre 18.00 72000.00

Metre 81.00 40500.00

Metre 315.00 126000.00


Each 837.00 66960.00

Each 1080.00 54000.00


Each 1044.00 20880.00

Each 1458.00 145800.00

Each 594.00 29700.00


Each 854.00 42700.00

Metre 72.00 288000.00

Metre 54.00 108000.00

Each 207.00 5175.00

Each 513.00 12825.00

Each 3780.00 7560.00

Metre 108.00 54000.00

Metre 45.00 45000.00


Each 72.00 3600.00

Each 81.00 4050.00

Each 16650.00 166500.00

Each 198.00 4950.00

Metre 63.00 63000.00

Metre 18.00 5400.00

Metre 845.00 42250.00

Metre 801.00 40050.00


Metre 333.00 16650.00

Metre 378.00 18900.00

Each 90.00 3600.00


Each 90.00 7200.00
Each 54.00 1620.00
Each 63.00 1890.00
Metre 18.00 5400.00
Metre 27.00 2700.00
4,271,778.00

4,000,000.00

6.79%

Rs. 4,271,778.00
Providing power and lighting facility for renovation of SSD building ECIL, Hyderabad
ESD_ELEC-588
S.No PLNO (Item Description Quantity
1 1.1 Supply and installation of sheet steel flush mounted double door type three phase 7.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 160A, 12-way TPN DPX MCCB DB (Cat No: 5077
48)Make: Legrand / L&T / Siemens / Schneider

2 1.2 Supply and installation of sheet steel flush mounted double door type three phase 10.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 8-Way VTPN DB (5077 27)Make: Legrand / L&T /
Siemens / Schneider

3 1.3 Supply and installation of sheet steel flush mounted double door type three phase 3.000
vertical bus-bar MCCB/VTPN distribution board with phase and neutral to install
on wall / column including Cable end boxes, MS angular frame work with
necessary accessories, internal wiring, earthing, painting, numbering, and minor
civil works etc., complete. 4-Way VTPN DB (5077 25)Make: Legrand / L&T /
Siemens / Schneider

4 2.1 Supply and installation of sheet steel flush mounted double door type single phase 2.000
distribution board with phase and neutral to install on wall / column including MS
angular frame work with necessary accessories, internal wiring, earthing, painting,
numbering, and minor civil works etc., complete. 8-Way SPN DB (Cat No. 5076
11)Make: Legrand / L&T / Siemens / Schneider

5 3.1 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 7.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 160A DPXMCCB (Cat No: 4200 17) Make:
Legrand / L&T / Siemens / Schneider

6 3.2 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 10.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A FPMCB (Cat No: 4087 02)Make: Legrand /
L&T / Siemens / Schneider

7 3.3 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 10.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A RCCB (Cat No: 4118 88)Make: Legrand /
L&T / Siemens / Schneider

8 3.4 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 24.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 63A TPMCB (Cat No: 4086 61)Make: Legrand /
L&T / Siemens / Schneider
9 3.5 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 24.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 32A TPMCB (Cat No: 4086 58)Make: Legrand /
L&T / Siemens / Schneider

10 3.6 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 2.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge. 40A DPMCB (Cat No. 4086 37)Make: Legrand /
L&T / Siemens / Schneider

11 3.7 Supply and Fixing of following MCCB/MCBs in the above mentioned distribution 288.000
board including required wiring, identification & numbering complete as per the
directions of Engineer In-charge.10/20/32A SPMCBs (Cat No: 4085
90/93/95)Make: Legrand / L&T / Siemens / Schneider

12 4 Supply and Installation of 32 A TPN 5 pin plug & socket P17 Tempra model (Cat 10.000
No.5078 62) with 40A, 100ma FPRCCB (Cat No.4118 82) to install on DB with
suitable knock out for incoming cables to draw the three phase power supply
including MS frame work to fix on wall / column with required fasteners, earthing,
painting, numbering and minor civil works etc., complete. Make: Legrand / L&T /
Siemens / Schneider

13 5 Supply and Installation of 250 V grade 3-pin metal clad protected weather proof 20.000
plug socket, housed in Legrand MS box with 20A socket (Cat No.5078 14) with
plug top controlled by 20A DPRCCB (Cat No.4118 56) including earthing, neutral
link internal wiring, painting and numbering etc., complete to fix on suitable MS
bracket / frame work to wall / column as detailed. Make: Legrand / L&T / Siemens /
Schneider

14 6.1 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 2-Way
6/16A Modular Power socket controlled by 2 Nos of 16A Modular switch.
Make: North West / Legrand / L&T/Schneider

15 6.2 Supply and installation of following modular type plug sockets with Modular type 30.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 4-Way
6A Modular Power sockets controlled by 4Nos of 6A Modular switches. Make:
North West / Legrand / L&T/Schneider

16 6.3 Supply and installation of following modular type plug sockets with Modular type 30.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 3-Way
6A Modular Power socket controlled by 2 Nos of 6A Modular switch. Make:
North West / Legrand / L&T/Schneider
17 6.4 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 6A
Modular Power socket controlled by 6A Modular switchMake: North West /
Legrand / L&T/Schneider

18 6.5 Supply and installation of following modular type plug sockets with Modular type 70.000
switches with Including supply of suitable mounting boxes, Dummies, Inner plates,
Cover plates with internal wiring and minor civil works etc., complete. 1-way 16A
Modular Power socket controlled by 16A Modular switch.Make: North West /
Legrand / L&T/Schneider

19 7 Supply and installation of 600mmX600mm recessed type 34-40W LED false 230.000
ceiling lighting fixtures with LEDs mounted symmetrically inside the fitting and with
equal distribution of light including control circuitry duly wired to operate at 150-
290VAC, 50Hz to be fixed to beam / ceiling / on false ceiling including supply of all
necessary clamps supports, chains, pipes, fasteners, ball & sockets where
needed and earthing etc., complete Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VINLEDs: OSRAM/ Nichia / Cree

20 8 Supply and Installation, testing and commissioning of 4feet industrial box type 100.000
LED lighting fixture of 20-22 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete. Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

21 9 Supply and Installation, testing and commissioning of 4 feet industrial box type 100.000
LED lighting fixture of 36-40 watts LED lamps with necessary accessories like
Electronic ballast to be fixed to beam / ceiling / on false ceiling including supply of
all necessary accessories like supports, pipes, ball and sockets where needed,
fasteners and earthing etc., complete.Make: Philips / Crompton
/Havells/Syska/wipro/ Bajaj/VIN

22 10 Supply and Installation of high speed 1400mm sweep ceiling fan capacitor type 60.000
suitable to operate on 230 volts AC supply with blades, down rod, top and bottom
canopies to ISS 374/1979 double ball bearing including Northwest make electronic
step type speed control regulator and necessary fan hook to fix to ceiling / beam
with required accessories and fasteners etc., complete. Make: Crompton (High
speed HSD-1400mm)/Bajaj/Orient

23 11 Supply and installation of 400mm sweep oscillating type wall mounted fan suitable 30.000
to operate on single phase 230V 50Hz AC supply to be installed on Wall / Column
with required MS frame work, wiring and necessary civil works etc., complete.
Make: Orient / Bajaj / Almonard
24 12.1 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 500.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete. 5
X 6 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

25 12.2 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 3000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 4 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

26 12.3 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 4000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
2 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

27 12.4 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 3000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1 X 2.5 Sq.mm PVC copper wire.Make: Finolex/L&T/KEI/Universal/RR Kabel
/Lapp/Bonton/Havells

28 12.5 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 4000.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 1.5 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

29 12.6 Supply and drawing of 600V grade PVC insulated copper FRLS wires in existing 500.000
surface / recessed steel / PVC conduit in different colours preferably black colour
for neutral and green colour for shield including interconnections etc., complete.
1X 10 Sq.mm PVC copper wireMake: Finolex/L&T/KEI/Universal/RR Kabel /
Lapp/Bonton/Havells

30 13.1 Supply of following 1100V grade XLPE insulated PVC sheathed armoured heavy 400.000
duty copper conductor Cables of approved make conforming to IS-7098 (Part-I)
specifications. 4 core, 10 Sq.mm Copper cableMake: Finolex / L&T / KEI /
Universal
31 14.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 80.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply
of all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling one light / Fans.Make:
Finolex/L&T (wires) & North West / Legrand / L&T Switches. Conduit:
Sudhakar/VIP/Precision

32 14.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, FRLS PVC
conduit pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess),
columns, furniture (including supply of conduit and its accessories) supported on
saddles with number of wires bunched at certain places, controlled by 6A, 250V
single pole Modular type switches for light / fan point including 6A socket for wall
mounting fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type
switches for Flood light, flush marked mounted on suitable mounting boxes (MS),
Inner plates, Cover plates with internal wiring. Supply being tapped from DB with 2
nos. of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of
all necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box
earthing the installation with 1.5 Sq.mm PVC copper wire (Green colour) and
numbering etc., complete. One switches controlling two lights.Make: Finolex/L&T
(wires) & North West / Legrand / L&T Switches. Conduit: Sudhakar/VIP/Precision
33 15.1 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 20.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling one light / Fans.Make: Finolex/L&T (wires) &
North West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

34 15.2 Modular Point Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 100.000
copper wire preferably black colour for neutral of 1100 volts grade, MS conduit
pipe from 20mm / 25mm / 32mm to be laid on walls (Surface / recess), columns,
furniture (including supply of conduit and its accessories) supported on saddles
with number of wires bunched at certain places, controlled by 6A, 250V single pole
Modular type switches for light / fan point including 6A socket for wall mounting
fan, ceiling rose for tube light fixture / ceiling fan and 15A Modular type switches
for Flood light, flush marked mounted on suitable mounting boxes (MS), Inner
plates, Cover plates with internal wiring. Supply being tapped from DB with 2 nos.
of multi strands 2.5 Sq.mm PVC copper wire for primary Light / Fan. Supply of all
necessary accessories like, ceiling rose, BH/AH, 6A, MS junction box earthing the
installation with 1.5 Sq.mm PVC copper wire (Green colour) and numbering etc.,
complete. One switches controlling two lights.Make: Finolex/L&T (wires) & North
West / Legrand / L&T Switches.MS Pipe: BEC / Gupta / National / Victory /
Bharath

35 16.1 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling one
light / Fans.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches
36 16.2 Modular Point Re-Wiring With 2 Nos. of multi strand 1.5 Sq.mm PVC insulated FR 50.000
copper wire preferably black colour for neutral of 1100 volts grade, in existing
PVC/steel conduit pipe from 20mm / 25mm / 32mm laid on walls (Surface /
recess), controlled by 6A, 250V single pole Modular type switches for light / fan
point including 6A socket for wall mounting fan, ceiling rose for tube light fixture /
ceiling fan and 15A Modular type switches for Flood light, flush marked mounted
on suitable mounting boxes (MS), Inner plates, Cover plates with internal wiring.
Supply being tapped from DB with 2 nos. of multi strands 2.5 Sq.mm PVC copper
wire for primary Light / Fan. Supply of all necessary accessories like, ceiling rose,
BH/AH, 6A, MS junction box earthing the installation with 1.5 Sq.mm PVC copper
wire (Green colour) and numbering etc., complete. One switches controlling two
lights.Make: Finolex/L&T (wires) & North West / Legrand / L&T Switches

37 17.1 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 4000.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 25 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

38 17.2 Supply and laying of heavy duty medium class FRLS PVC conduit pipe with 2000.000
necessary accessories such as bends, junction boxes, reducers etc., on wall
(surface / recess) / column / beam / roof / concealed in wall supported on saddles,
clamps, including all minor civil works welding, painting, earthing etc., complete
and as per instructions of Engineer In- charge. 20 mm dia. FRLS PVC conduit
pipe.Make: VIP / Sudhakar / Precision

39 18.1 Supply and fixing of following communication outlet sockets to be mounted in a 25.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ11 telephoneMake: Northwest/ Legrand / L&T
40 18.2 Supply and fixing of following communication outlet sockets to be mounted in a 25.000
cover plates fixed to wall / columns / departmental supplied modular furnitures.
RJ 45 LAN (CAT-6)Make: Northwest/ Legrand / L&T
41 19.1 Supply and Installation of krone connector type telephone distribution box in sheet 2.000
steel enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with
castle key lock, hinged gasketed type cover and connected fasteners etc.,
complete 50 Pair DB box

42 20.1 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 500.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 20 pair
PVC Telephone cablesMake: Finolex / Delton

43 20.2 Supply and laying of following pair 0.5 mm dia FRLS PVC insulated annealed 1000.000
copper conductor unarmoured telephone cables in laid conduits, modular
furnitures raceways etc., as per the instructions of Engineer In-charge. 04 pair
PVC Telephone cablesMake: Finolex / Delton
44 21.1 Supply and fixing of following Modular convex type cover plate to be fixed on 50.000
modular furniture / GI Metal box on walls / Columns. 2-Modular cover plateMake:
Northwest/ Legrand / L&T

45 22 Supply and Installation of Two-Module modular metal enclosure boxes including 50.000
fixing in the wall surface / recess, modular furniture with minor civil works
etc,Make: Northwest/ Legrand / L&T.
46 23 Supply, Installation, Testing & Commissioning of new Earth pits as per IS 3043 10.000
with UL Listed 3/4 copper bonded steel rod of 3 Mtrs long, scope of work
includes all civil works like excavation of pit (3 Mtrs depth), backfilling the pit with
Carbon based chemical Ground Enhancement material of 22.5KG to be supplied
by the contractor including construction of chamber for the pit, frame around the
pit, supply of pit cover, measurement of earth pit resistance complete as per the
instructions of Engineer In-charge. Make: DEHN / ABB / Infinity

47 24 ANTI - STATIC EARTH TERMINALS: i) Supply and installation of 200mm in 25.000


length, 25mm width and 3mm thick soft drawn hot dipped Tin coated Copper strip
with porcelain bases as supports of suitable size with provision for tapping from
the strip including chromium coated hardware to fix on wall / column at the height
of 0.5 Mtr from floor level with anti-static indicator including supply of necessary
accessories, welding, bending, drilling and minor civil works etc., complete as per
instructions of Engineer In-charge.

48 25.1 Supply and laying of hot dip GI /Copper strip / wire as under including 1000.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. 25 x 3 mm G.I strip

49 25.2 Supply and laying of hot dip GI /Copper strip / wire as under including 300.000
interconnections and tapping, wherever necessary on wall / partition / trench /
underground by excavation from earth pit to the building, with required civil works
like welding, clamping and painting etc., complete. N0.8 SWG G.I wire

50 26.1 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.450 x62.5 x2mm cable Tray

51 26.2 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 450X62.5mm above size with 2mm
thickness
52 26.3 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.150 x50 x1.6mm cable Tray

53 26.4 Supply and Installation of following Perforated galvanized iron cable tray, 50.000
Including fixing of supports to Walls / beams / pillars / Ceiling / Floor with required
hardware like channels, rods at a equal intervals of 1Mtr, Welding for installing the
cable trays over the false ceiling and other areas as per the instructions of
Engineer In-charge.Cable tray cover for above 150X50mm size with 2mm
thickness

54 27.1 Removals of old electrical fittings: Ceiling fans 40.000


55 27.2 Removals of old electrical fittings: Tube light fixtures 80.000
56 27.3 Removals of old electrical fittings: Switch boards with MS box 30.000
57 27.4 Removals of old electrical fittings: Metal clad sockets with MS box 30.000
58 27.5 Removals of old electrical fittings: MS / PVC pipes along with wires 300.000
59 27.6 Removals of old electrical fittings: Armoured cables 100.000
Total

Estimated Cost

Quote Percent
ding ECIL, Hyderabad

Unit Rate Amount


Each 13419 93933.00

Each 8658 86580.00

Each 6813 20439.00

Each 1800 3600.00

Each 7101 49707.00

Each 1692 16920.00

Each 3195 31950.00

Each 1341 32184.00


Each 882 21168.00

Each 873 1746.00

Each 198 57024.00

Each 6093 60930.00

Each 3213 64260.00

Each 909 63630.00

Each 1305 39150.00

Each 1053 31590.00


Each 387 27090.00

Each 495 34650.00

Each 2961.00 681030.00

Each 1980.00 198000.00

Each 2700.00 270000.00

Each 2151.00 129060.00

Each 1458.00 43740.00


Metre 234 117000.00

Metre 54 162000.00

Metre 45 180000.00

Metre 27 81000.00

Metre 18 72000.00

Metre 72 36000.00

Metre 297 118800.00


Each 783 62640.00

Each 1017 50850.00


Each 981 19620.00

Each 1377 137700.00

Each 558 27900.00


Each 801 40050.00

Metre 63 252000.00

Metre 54 108000.00

Each 198 4950.00

Each 486 12150.00

Each 3555 7110.00

Metre 108 54000.00

Metre 45.00 45000.00


Each 72.00 3600.00

Each 81.00 4050.00

Each 16650.00 166500.00

Each 198.00 4950.00

Metre 63.00 63000.00

Metre 18.00 5400.00

Metre 846.00 42300.00

Metre 801.00 40050.00


Metre 333.00 16650.00

Metre 378.00 18900.00

Each 90.00 3600.00


Each 90.00 7200.00
Each 54.00 1620.00
Each 63.00 1890.00
Metre 18.00 5400.00
Metre 27.00 2700.00
4,034,961.00

4,000,000.00

0.87%

Rs. 4,034,961.00