You are on page 1of 1

Aspen Exchanger Design and Rating Fired Heater V11

File: C:\Users\Hafidz Aliyufa\Documents\ALIYUFA\..\QFiredHeater7.EDR Printed: 11/7/2019 at 8:02:20 PM

API Combustion

COMBUSTION DESIGN CONDITIONS


1 Type of fuel Fuel Mix Fuel 1 Fuel 2 Fuel 3 Fuel 4
2 Fuel flowrate kg/h 355 355
3 Excess air, % 5
4 Calculated heat release (LHV) kW 4929.6
5 Calculated fuel efficiency (LHV), % 93.25225
6 Flue gas temp leaving: Radiant sect. °C 171
7 : Convection °C 171
8 : Air preheater °C
9 Flue gas quantity (wet) kg/h 6126
10 Flue gas mass vel. (bank1-bank5) kg/s/m²
11 Flue gas mass vel. (bank6-bank9) kg/s/m²
12 Draft at arch Pa -80.1
13 Draft at burners Pa -172.3
14 Ambient air temp. (efficiency calc.) °C 20
15 Ambient air temp. (stack design) °C 20
16 FUEL CHARACTERISTICS:
17 Type of fuel Fuel Mix Fuel 1 Fuel 2 Fuel 3 Fuel 4
18 Fuel lower calorific value (LHV) kJ/kg 50034.8 50034.8
19 Temperature @ burner °C 25
20 Composition (mass fraction)
21 Carbon - 0.7487 0.7487
22 Hydrogen - 0.2513 0.2513
23 Oxygen - 0 0
24 Nitrogen - 0 0
25 Sulphur - 0 0
26 Ash - 0 0
27 BURNER DATA:
28 Type natural draught, low NOX (API 560) Number 1
29 Heat release per burner kW 4929.6 Location bottom