Professional Documents
Culture Documents
Type 6518
Type 2508 Type 2513 Type 2510/11 Type 2012 Type 2030
Cable plug Cable plug Cable plug ASI Single seat valve Diaphragm valve
(ATEX Cat. 3 GD)
www.burkert.com S. 1/37
6518/6519
Type 6518/6519 Standard (with tag connector acc.to DIN EN 175301-803 Form A, without cable plug)
Technical data
Orifice Type 6518 DN8 mm
Type 6519 DN8 and 9 mm
Body material
Type 6518
Pilot and main valve Polyamide, reinforced glass-fibre
Type 6519
Pilot valve Polyamide, reinforced
Main valve Polyamide (5/2 way), aluminium (5/3 way)
Type 6518
Threaded socket material Brass (stainless steel on request)
Standard Type 6519 Seal material Type 6518 NBR and PUR
Standard Type 6519 NBR and PUR (5/2 way), NBR (5/3 way)
Medium Neutral Medium, e.g. lubricated or non-lubricated com-
pressed air
Compressed air quality ISO 8573-1:2010, Class 7.4.4*
Type 6518 and the Type 6519 together form a product Medium temperature - 10 °C to + 50 °C
line. Both types can be mounted on a pneumatic module. Ambient temperature - 25 °C to + 55 °C
The valve width of 32 mm allows high flow rates. A sole- Pneumatic connection
Supply port connection 1, 3, 5 Thread G ¼, multi-station manifold (on request NPT ¼)
noid valve Type 6014 is used as a pilot. The valves can Service port 2, 4 Thread G ¼ (on request NPT ¼)
be used individually or in blocks. Operating voltages 24 V DC
24/ 110/ 230 V/ 50 - 60 Hz
Power consumption Voltage tolerance + 10 %
Inrush Hold (hot coil) Duty cycle 100 % continuous operation
AC [VA] AC [VA/W] DC [W] Electrical connection Tag connector acc. to DIN EN 175301-803 (previously
DIN 43650) Form A for cable plug Type 2508
11 6/2 2 Type of protection IP65 with cable plug
Response times1) Installation As required, preferably with actuator upright
Opening 20 [ms] * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than
Closing 40 [ms] the temperature of the medium.
1)
Measured at valve outlet at 6 bar and + 20 °C acc. to ISO 12238.
Opening: Pressure rise 0 to 90 %,
Closing: Pressure drop 100 to 10 %
Frequency
Article no.
Weight [g]
power [W]
Threaded
and body
QNn value
Pressure
Voltage/
Nominal
function
material
range2)
Orifice
Circuit
[l/min]
[V/Hz]
[inch]
[mm]
[bar]
Seal
port
air1)
Type 6518 Standard – Brass threaded socket, also threads 1 and 3 of multi-station manifold; without cable plug
C 2(A) 8.0 NBR and G¼ 1300 2 - 8 370 2 024/DC 132457
12 PUR 024/50 - 60 132458
1(P) 3(R) (Polyamide)
110/50 - 60 132459
3/2 way servo-controlled solenoid valve,
normally closed, with manual override 230/50 - 60 132460
D 2(B) 8.0 NBR and G¼ 1300 2 - 8 370 2 024/DC 132461
10
PUR 024/50 - 60 132462
1(P) 3(R) (Polyamide)
110/50 - 60 132463
3/2 way servo-controlled, solenoid valve,
normally open, with manual override 230/50 - 60 132464
Type 6519 Standard – Brass threaded socket, also threads 1, 3 and 5 of multi-station manifold; without cable plug
H 4 2 8.0 NBR and G¼ 1300 2 - 8 450 2 024/DC 132465
14 PUR
12 024/50 - 60 132466
5 1 3 (Polyamide)
5/2 way servo-controlled solenoid valve, 110/50 - 60 132467
with manual override 230/50 - 60 132468
L 4 2 9.0 NBR G¼ 1300 3 - 10 720 2 024/DC 132469
14 12
(Aluminium) 024/50 - 60 132470
5 13
110/50 - 60 132471
5/3 way solenoid valve, in middle position
all ports locked, with manual override 230/50 - 60 132472
N 4 2 9.0 NBR G¼ 1300 3 - 10 720 2 024/DC 132473
14 12
(Aluminium) 024/50 - 60 132474
5 13
110/50 - 60 132475
5/3 way valve, in middle position ports 2
and 4 open, with manual override 230/50 - 60 132476
1) Flow rate: QNn value air [l/min]: Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference
2) Pressure values [bar]: Overpressure with respect to atmospheric pressure
S. 2/37
6518/6519
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Technical data
Orifice Type 6518 DN8 mm
Type 6519 DN8 and 9 mm
Body material
Type 6518 - Pilot & main valve Polyamide, reinforced glass-fibre
Type 6519 - Pilot valve Polyamide, reinforced glass-fibre
Main valve Polyamide (5/2 way), aluminium (5/3 way)
Threaded socket material Brass (stainless steel on request)
Seal material Type 6518 NBR and PUR
Type 6519 NBR and PUR (5/2 way), NBR (5/3 way)
Medium Neutral medium, e.g. lubricated or non-lubricated
compressed air
Compressed air quality ISO 8573-1:2010, Class 7.4.4*
Medium temperature - 10 °C to + 50 °C
Type 6519 Ex m Ambient temperature - 25 °C to + 50 °C
Type 6518 Ex m
Pneumatic connection
Supply port connection 1, 3, 5 Thread G ¼, multi-station manifold (on request NPT ¼)
Service port 2, 4 Thread G ¼ (on request NPT ¼)
The approval Ex m is achieved by the mounting of an Operating voltages 24/ 110/ 230 V/UC
approved push-over coil. The cable connection and the Voltage tolerance + 10 %
cable are non-detachable and sealed together with the Duty cycle 100 % continuous operation
valve. The valves can be used individually or in blocks. Electrical connection 3 m cable, moulded
junction box (without fuse)
Type of protection IP65
Response times1) Approvals
Opening 20 [ms] Coil PTB 14 ATEX 2023 X / IECEx PTB 14.0049 X
Closing 50 [ms] II 2G Ex mb IIC T5 Gb
II 2D Ex mb IIIC T 100 °C Db
1)
Measured at valve outlet at 6 bar and + 20 °C acc. to ISO 12238. Junction box EPS16 ATEX 1046 X / IECEx EPS 16.0021 X
Öffnen: Pressure rise 0 to 90 % II 2G EX eb mb IIC T5 Gb
Closing: Pressure drop 100 to 10 % II 2D EX mb tb IIIC T100 °C Db
Installation As required, preferably with actuator upright
* T
o prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the
temperature of the medium.
Frequency
Article no.
Weight [g]
power [W]
Threaded
and body
QNn value
Pressure
Voltage/
Nominal
function
material
range2)
Orifice
Circuit
[l/min]
[V/Hz]
[inch]
Luft1)
[mm]
[bar]
Seal
port
Type 6518 Ex m – Brass threaded socket, also threads 1 and 3 of multi-station manifold; with moulded cable, 3 m long3)
C 2(A) 8.0 NBR G¼ 1300 2 - 8 600 3 024/UC 278195
12
and 110/UC 278200
1(P) 3(R) PUR
230/UC 278201
3/2 way servo-controlled solenoid valve, (Polyamide)
normally closed, with manual override
D 2(B) 8.0 NBR G¼ 1300 2 - 8 600 3 024/UC 278205
10
and 110/UC x
1(P) 3(R) PUR
230/UC x
3/2 way servo-controlled, solenoid valve, (Polyamide)
normally open, with manual override
Type 6519 Ex m – Brass threaded socket, also threads 1, 3 and 5 of multi-station manifold; with moulded cable, 3 m long4)
H 4 2 8.0 NBR G¼ 1300 2 - 8 700 3 024/UC 278209
14
and 110/UC 278212
12
5 1 3 PUR
230/UC 278213
5/2 way servo-controlled solenoid valve, (Polyamide)
with manual override
L 4 2 9.0 NBR G¼ 1300 3 - 10 1.100 3 024/UC 278221
14 12
(Aluminium) 110/UC x
5 13 230/UC x
5/3 way solenoid valve, in middle position
all ports locked, with manual override
N 4 2 9.0 NBR G¼ 1300 3 - 10 1.100 3 024/UC 278222
14 12
(Aluminium) 110/UC x
5 13 230/UC x
5/3 way valve, in middle position ports 2
and 4 open, with manual override
1)
Flow rate: QNn value air [l/min]: Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference
2)
Pressure values [bar]: Overpressure with respect to atmospheric pressure
3)
Versions with junction box on request
4)
Circuit function H (5/2 way) as impulsee version on request
S. 3/37
x = on request
6518/6519
Type 6518/6519 Ex i (with Tag connector acc. to DIN EN 175301-803 Form A, without cable plug)
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Technical data
Orifice Type 6518 DN8 mm
Type 6519 DN8 and 9 mm
Body material
Pilot valve Stainless steel 1.4305 or brass
Main valve Polyamide, reinforced glass-fibre
Threaded socket material Brass (stainless steel on request)
Seal material FPM, NBR and PUR
Medium Neutral medium, e.g. lubricated or non-lubricated
compressed air
Compressed air quality ISO 8573-1:2010, Class 7.4.4*
Medium temperature - 10 °C to + 50 °C
Type 6518 Ambient temperature - 25 °C to + 55 °C
Ex i Type 6519
Pneumatic connection
Ex i Supply port connection 1, 3, 5 Thread G ¼, multi-station manifold (on request PT1/4)
Service port 2, 4 Thread G ¼ (on request NPT ¼)
The intrinsically-safe Type 6518 Ex i and 6519 Ex i valves
Duty cycle 100 % continuous operation
consist of an intrinsically-safe pilot control and a pneumatic
Electrical connection Tag connector acc. to DIN EN 175301-803 (previ-
amplifier. The diaphragm-controlled valve seats work with
ously DIN 43650) Form A for cable plug Type 2508
very low friction, ensuring reliable switching of the valve,
(not in delivery, see accessories), check for correct
even after long shutdown periods.
polarity
Response times1) Type of protection IP65 with cable plug
Opening 75 [ms] Installation As required, preferably with actuator upright
Closing 115 [ms] * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than
Measured at valve outlet at 6 bar and + 20 °C acc. to ISO 12238.
1) the temperature of the medium.
Opening: Pressure rise 0 to 90 %
Closing: Pressure drop 100 to 10 %
Electrical data - Coil AC10 Ex i
Approvals PTB 01 ATEX 2101 / PTB IECEx 10.0019
Note II 2G Ex ia IIC T6 Gb
These units may only be used in explosive atmospheres in II 2G Ex ia IIIC T80 °C Db
the manner approved by the Federal Institute of Physics and Function values for
Technology (PTB), i.e., the permissible maximum electrical Switching function valve1) at + 20 °C at + 55 °C
values must be complied with. Suitable barriers and isolating
Minimum switching current 29 mA 29 mA
modules are available for this.
Nominal resistance coil 310 Ω 360 Ω
Minimum terminal voltage 9.0 V 10.4 V
Conformity specifications
Ui 35 V
Ii 0.9 A
The valve is intended for operation on 24 V DC outputs via the Pi 1.1 W
intermediate switching of a corresponding intrinsically-safe 1)
With high resistance coil on request
operating resource (isolating module or barrier).
If required, request the “Recommended Barrier and Isolating
Module” data sheet.
Ordering chart for valves without manual override (with manual override and high resistance coil on request)
range2) [bar]
connection
air control
pilot valve
Article no.
Weight [g]
connector
terial and
Threaded
QNn value
Seal ma-
Pressure
Material
function
material
Orifice
Circuit
[l/min]
[inch]
Body
Luft1)
[mm]
body
port
Type 6519 NAMUR Standard (with Tag connector acc. to DIN EN 175301-803 Form A, without cable plug)
Technical data
Orifice Type 6519 DN6 mm
Body material
Type 6519 Pilot and main valve Polyamide, reinforced glass-fibre
Threaded socket material Brass (stainless steel on request)
Seal material Type 6519 NBR and PUR
Medium Neutral medium, e.g. lubricated or non-lubricated
compressed air
Compressed air quality ISO 8573-1:2010, Class 7.4.4*
Medium temperature - 10 °C to + 50 °C
Ambient temperature - 25 °C to + 55 °C
Pneumatic connection
Type 6519 NA- Supply port connection 1, 3, 5 Thread G ¼, (on request NPT ¼)
MUR Standard
Service port 2, 4 NAMUR Flange
Operating voltages 24 V DC
24/ 110/ 230 V/ 50 - 60 Hz
The valve bodies of Type 6519 NAMUR are identi- Voltage tolerance + 10 %
cal with the Ex m variants. The difference is in the Duty cycle 100 % continuous operation
coils, which are laid out and approved in different Electrical connection Tag connector acc. to DIN EN 175301-803 (previ-
ways. By changing the coil on the valve body, it is ously DIN 43650) Form A for cable plug Type 2508
possible to easily convert from Non-Ex operation to Type of protection IP65 with cable plug
Ex operation (or vice versa). The coils are designed Installation As required, preferably with actuator upright
to be push-over and can be locked in 4 × 90° * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the
displaced positions and be positioned any where temperature of the medium.
in-between.
Power consumption Response times1)
Inrush Hold (hot coil)
Opening 20 [ms]
AC [VA] AC [VA/W] DC [W]
Closing 40 [ms]
11 6/2 2
1)
Measured at valve outlet at 6 bar and + 20 °C acc. to ISO 12238.
Opening: Pressure rise 0 to 90 %,
Closing: Pressure drop 100 to 10 %
Frequency
Article no.
Weight [g]
power [W]
Electrical
Threaded
and body
QNn value
sockets1)
Pressure
Voltage/
Material
function
material
nominal
range3)
Orifice
Circuit
[l/min]
[V/Hz]
[inch]
Luft2)
[mm]
[bar]
Seal
port
W 024/DC 131425
4 2
14
NBR
12 and Stainless 024/50 - 60 131426
6.0 G¼ 900 2 - 8 460 2
3 15 PUR steel 110/50 - 60 131427
or
230/50 - 60 131428
4 2 024/DC 131421
14
W 12 NBR 024/50 - 60 131422
5 1 3 Brass,
and 110/50 - 60 131423
6.0 nickel G¼ 900 2 - 8 460 2
PUR
plated
5/2 or 3/2 way solenoid valve,
with removable disk and manual 230/50 - 60 131424
override
1)
When the connecting sockets are made of stainless steel, then the mounting screws are also made of stainless steel
2)
Flow rate: QNn value air [l/min]: Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference
3)
Pressure values [bar]: Overpressure with respect to atmospheric pressure
All valves can be operated in circuit function C as well as in circuit function H. By replacing the adapter
plate that comes with the valves, the change between the two circuit functions can be set up.
S. 5/37
6518/6519
connection
Frequency
Article no.
Weight [g]
power [W]
Electrical
and body
QNn value
sockets1)
Pressure
Voltage/
Nominal
Material
function
range3)
Circuit
[l/min]
[V/Hz]
[inch]
Luft2)
[bar]
1)
When the connecting sockets are made of stainless steel, then the mounting screws are also made of stainless steel x on request
2)
Flow rate: QNn value air [l/min]: Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference
3)
Pressure values [bar]: Overpressure with respect to atmospheric pressure
All valves can be operated in circuit function C as well as in circuit function H. By replacing the adapter plate that comes with the valves, the change between the
two circuit functions can be set up.
S. 6/37
6518/6519
Type 6519 NAMUR Ex i (with Tag connector acc. to DIN EN 175301-803 Form A, without cable plug)
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Technical data
Orifice DN6 mm
Body material
Pilot valve Stainless steel 1.4305 or brass
Main valve Polyamide, reinforced glass-fibre
Threaded socket material Brass (stainless steel on request)
Seal material FPM, NBR and PUR
Medium Neutral medium, e.g. lubricated or non-lubricated
compressed air
Compressed air quality ISO 8573-1:2010, Class 7.4.4*
Medium temperature - 10 °C to + 50 °C
Ambient temperature - 25 °C to + 55 °C
Pneumatic connection
Type 6519 NAMUR Ex i Supply port connection 1, 3, 5 Thread G ¼, (on request NPT ¼)
Service port 2, 4 NAMUR Flange
Duty cycle 100 % continuous operation
The Type 6519 NAMUR Ex i valve is used for the pneumatic
Electrical connection Tag connector acc. to DIN EN 175301-803 (previously
DIN 43650) Form A for cable plug Type 2508 (not in de-
control of double or single-acting actuators with a NAMUR
adapter plate flange. The circuit function can easily be livery, see accessories), check for correct polarity
changed using an adapter plate. In the 3/2 way function, Type of protection IP65 with cable plug
feedback of the exhaust air takes place in the spring area Installation As required, preferably with actuator upright
of the armature drive. The diaphragm-controlled valve seats * To
prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than
work with very low friction, ensuring reliable switching of the the temperature of the medium.
valve even after long shutdown periods and at ambient tem- 1)
Measured at valve outlet at 6 bar and + 20 °C acc. to ISO 12238.
Response times1) [ms]
peratures below 0 °C. The valves work without a continuous Opening: Pressure rise 0 to 90 %
air consumption. Opening 75 Closing: Pressure drop 100 to 10 %
Closing 115
Note
The units may only be used in explosive atmospheres in the Electrical data
manner approved by the Federal Institute of Physics and Approvals PTB 01 ATEX 2101 / PTB IECEx 10.0019
Technology (PTB), i.e., the permissible maximum electrical II 2G Ex ia IIC T6 Gb
values must be complied with. Suitable barriers and isolat- II 2G Ex ia IIIC T80 °C Db
ing modules are available for this. Function values for
Switching function valve1) at + 20 °C at + 55 °C
Minimum switching current 29 mA 29 mA
Nominal resistance coil 310 Ω 360 Ω
Minimum terminal voltage 9.0 V 10.4 V
The valve is intended for operation on 24 V DC outputs via
Conformity specifications
Ui 35 V
the intermediate switching of a corresponding intrinsically- Ii 0.9 A
safe operating resource (isolating module or barrier). Pi 1.1 W
If required, request the “Recommended Barrier and Isolating 1)
With high resistance coil on request
Module” data sheet.
Ordering chart for valves without manual override (with manual override and high resistance coil on request)
without cable plug
range2) [bar]
Material air
connection
pilot valve
Article no.
Weight [g]
connector
Threaded
and body
QNn value
Pressure
function
material
material
control
Orifice
Circuit
[l/min]
[inch]
Body
Luft1)
[mm]
Seal
port
4 2
W 14 St. St. 144482
12 St. St.
3 15
1.4305
NBR Brass, nickel
or 144483
and plated
6.0 G¼ 900 2 - 8 670
PUR
4 2
W 14 (Polyamide)
12 Brass, nickel
Brass 147244
5 1 3 plated
5/2 or 3/2 way solenoid valve,
with removable disk
1) Flow rate: QNn value air [l/min]: Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference
2) Pressure values [bar]: Overpressure with respect to atmospheric pressure
All valves can be operated in circuit function C as well as in circuit function H. By replacing the adapter plate that comes with the valves, the change
between the two circuit functions can be set up. All valves have mounting plates and tag connectors acc. to DIN EN 175301-803 Form A
(previously DIN 43650) and are supplied without cable plug
S. 7/37
6518/6519
Connector module,
Pneumatic basic Pneumatic intermediate supply module: supply channel pushed
left
module, 3 valves through for additional pressure supply
or
Connector module, right: supply channel closed off, thereby several
operational pressures possible in a single block
Pneumatic
basic module,
2 valves
Connector module,
right
Supply ports
3(R)
1(P)
no.
Article
no.
S. 8/37
6518/6519
101,5
59 + (n x 33) 65
ø 5,5
15
3 3
182
1 1
102,5
115
124,8
120
249
108
24
58
100
92
82
57,5
48
5 5
G 1/2
G 1/8 6
10
33 NPT 1/2
NPT 1/8 8
G 1/4 55
NPT 1/4
46
n x 33 52
87 + (n x 33) 90
110 + (n x 33)
Valve assembly on pneumatic modules Type MP07 using the supplied M4 screws
S. 9/37
6518/6519
18
Accessories
18
Cable plug 2508 acc. to DIN EN 175301-803 Form A
46 Fixing screw
The delivery of a cable plug includes the flat seal and the fixing screw. For other cable plug
versions acc. to DIN EN 175301-803 Form A (previously DIN 43650) with
27,5
18
integrated circuitry, see datasheet Type 2508.
Flat seal
18
1,5
Dimensions Type 2508 [mm] M3
28
18 46
18
27,5
18
1,5
M3
46 28
27,5
Ordering chart
18
1,5
M3
28 2508
Cable plug
Beschaltung Voltage Article no.
For standard version 6518/19
18
BN
[in mm]
Article
length
Cable
[mm]
no.
BU 12000 260893
5000 260892
GNYE 3000 260891
300 260890
Accessories (continued)
Ex-Cable glands
(polyamide version included in delivery / surcharge applied for brass nickel plated version
Ex Approvals
Certification
Description
Identifica-
Article no
Drawing
Photo
tion
TL 29 - 37 mm
Brass.
L 6 mm
nickel- PTB 04 ATEX 1112 X, II 2 G Ex e IIC Gb,
773278 D 20
plated, IECEx PTB 13.0027X II 2 D Ex tb IIIC Db IP68,
6 - 13 mm SW 24 mm
E 27 mm
TL 36 - 45 mm
L 10 mm
Polyamide, PTB 13 ATEX 1015 X, II 2 G Ex e IIC Gb,
773277 D 20
7 - 13 mm IECEx PTB 13.0034X II 2 D Ex tb IIIC Db IP68
SW 24 mm
E 28 mm
Article no.
Descrip-
Photo
tion
Set SC02-AC10
Special wrench
293488
Service Manual
S. 11/37
6518/6519
Dimensions [mm]
Standard versions
Type 6518
3/2 way valve, circuit function C and D
32
SW 14 45
G1/8 20.5
11.2
G1/4 / NPT1/4
8 - 4.3 deep
G1/4 / NPT1/4
138.7
4.3
69.6
4.3
13.5
12
28.5
25.5
25.5
8
3 43 24
3 - 3 tief
24 53
32
Type 6519
5/2 way valve, circuit function H
32
SW 14 45
G1/8 20.5
11.2
G1/4 / NPT1/4
G1/4 / NPT1/4
4.3
28.5
8 - 4.3 deep
4.3
107.7
36
24
48
26.5
39.6
3 - 3 deep
3 43 24
24 53
32
S. 12/37
6518/6519
Dimensions [mm]
Standard versions
Type 6519
5/3 way valve, circuit function L and N
Standard version
32
SW 14 45
G1/8 20.5
11.2
G1/4 / NPT1/4
3 - 3 deep
G1/4 / NPT1/4
26 24
4.3
28.5
11 - 3 deep
43
36
250.2
112
24
70
48
4.5
26.5
50
44
32
S. 13/37
6518/6519
Dimensions [mm]
Ex m/me versions
Type 6518
3/2 way valve, circuit function C and D
Length acc. to D
A
ordering information C
SW 14
G1/8 B
6.2
10.9
mi
G1/4 / NPT1/4
n.
R2
8 - 4.3 deep
5
G1/4 / NPT1/4
138.7
4.3
4.3
69.6
13.5
12
28.5
25 5
25.5
3 - 3 deep
8
3 43 24
24 53
32
Coil size A B C D E F
5 32 20.5 46 68.8 99.8 174.7
with junction box (Ex me) 6 40 23.5 52 74.8 102.8 177.7
A F
SW 14 E
68 G1/8 M20x1.5 B
SW 27
29.7
R84
radius
10.9
Turning
41.3
84.3
G1/4 / NPT1/4
8 - 4.3 deep
138.7
4.3
69.6
4.3
13.5
12
25.5
25.5
3
24 43
32 53
S. 14/37
6518/6519
Dimensions [mm]
Ex m/me versions
Type 6519
5/2 way valve, circuit function H
A length acc. to D
SW 14 ordering information C
G1/8 B
6.2
10.9
G1/4 / NPT1/4
mi
n.
G1/4 / NPT1/4
R2
5
7.9 - 4.2 deep
176.85
4.3
28.5
107.75
4.3
8 - 4.3 deep
36
24
48
26.5
39.6
3 - 3 deep
43 24
24 53
32
A Length acc. to D
SW14 ordering information C
G1/8 B
6.2
G1/4 / NPT 1/4 10.9
mi
3 - 3 deep
n.
R2
5
26 24
4.3
11 - 3 deep
28.5
43
250.2
112
36
70
48
24
4.5
26.5
50
44
32
S. 15/37
6518/6519
Dimensions [mm]
Ex i versions
Type 6518
3/2 way valve, circuit function C Ex i- Zulassung
40
SW 14 51
G1/8 23,5
11,2
G1/4 / NPT1/4
8 - 4,3 tief
145,7
G1/4 / NPT1/4
4,3
7,9 - 4,2 tief
69,6
4,3
13,5
12
28,5
25,5
25,5
8
3 43 24
3 - 3 tief
24 53
32
Type 6519
5/2 way valve, circuit function H
Ex i Approval
40
SW 14 51
G1/8 23.5
11.2
G1/4 / NPT1/4
G1/4 / NPT1/4
4.3
28.5
8 - 4.3 deep
4.3
107.7
36
24
48
26.5
39.6
3 - 3 tief
3 43 24
24 53
32
S. 16/37
6518/6519
Dimensions [mm]
NAMUR Standard version
Type 6519
Standard version
3/2 way valve, circuit function C or 5/2 way valve, circuit function H
32
45
SW 14
20.5
G1/8
11.2
G1/4 / NPT1/4
176.8
5.3
107.7
48
24
51.6
51.6
32 3.95
37 32
53
S. 17/37
6518/6519
Dimensions [mm]
Type 6519
3/2 way valve, circuit function C or 5/2 way valve, circuit function H
A D
Length acc. to
SW 14 C ordering information
G1/8 B
6.2
10.9
G1/4 / NPT1/4
25
.R
min
176.8
5.3
107.7
48
24
51.6
51.6
32 3.95
37 32
53
Coil size A B C D E F
5 32 20.5 46 68.8 99.8 174.7
6 40 23.5 52 74.8 102.8 177.7
with junction box (Ex me)
F
E
20.5 M20x1.5
29.7
R84
Turnin
g radiu
s
41.3
G1/4 / NPT1/4
84.3
176.8
5.3
107.7
48
24
51.6
51.6
SW27
68 32 3.95
37 32
53
S. 18/37
6518/6519
Dimensions [mm]
NAMUR Ex i version
Type 6519
3/2 way valve, circuit function C or 5/2 way valve, circuit function H
Ex i Approval
40
SW 14 51
G1/8 23.5
11.2
G1/4 / NPT1/4
Aluminium
183.6
5.3
107.7
48
24
51.6
51.6
32 3.95
37 32
53
S. 19/37
6519
for extended
temperature range
Type 6519 for extended standard temperature range
Ordering chart for valves in aluminium with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Frequency
Article no.
Weight [g]
power [W]
QNn-value
Threaded
and body
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[l/min]
[V/Hz]
range
[inch]
[mm]
[bar]
Seal
port
air
5/2 WWH 9.0 FPM, NBR G ¼" 1800 2.5 - 10 680 2 024/DC 231386
4 2 024/50 - 60 231387
14
12 110/50 - 60 231388
5 1 3 230/50 - 60 231389
5/2-bistable WWZ 9.0 FPM, NBR G ¼" 2100 2.5 - 10 990 2 024/DC 231390
4 2 024/50 - 60 231391
14 12 110/50 - 60 231392
5 1 3 230/50 - 60 231393
5/3 WWL 9.0 FPM, NBR G ¼" 1500 2.5 - 10 1060 2 024/DC 231394
4 2 024/50 - 60 231395
14 12
110/50 - 60 231396
5 13
230/50 - 60 231397
5/3 WWN 9.0 FPM, NBR G ¼" 1500 2.5 - 10 1060 2 024/DC 231399
4 2
14 12 024/50 - 60 231400
110/50 - 60 231401
5 13
230/50 - 60 231402
S. 20/37
6519
for extended
temperature range
Ordering chart for valves in stainless steel with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Frequency
Article no.
Weight [g]
power [W]
QNn-value
Threaded
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[l/min]
[V/Hz]
range
[inch]
[mm]
body
[bar]
Seal
port
air
5/2 WWH 8.0 PU, NBR G ¼" 1980 3 - 10 1370 2 024/DC 231403
4 2 024/50 - 60 231404
14
12
110/50 - 60 231405
5 1 3 230/50 - 60 231406
5/2-bistable WWZ 8.0 PU, NBR G ¼" 1920 3 - 10 1680 2 024/DC 231407
4 2 024/50 - 60 231408
14 12
110/50 - 60 231409
5 1 3
230/50 - 60 231410
5/3 WWL 8.0 PU, NBR G ¼" 1770 3 - 10 1680 2 024/DC 231411
4 2 024/50 - 60 231412
14 12
110/50 - 60 231413
5 13 230/50 - 60 231414
5/3 WWN 8.0 PU, NBR G ¼" 1770 3 - 10 1680 2 024/DC 231415
4 2
14 12
024/50 - 60 231416
110/50 - 60 231417
5 13
230/50 - 60 231418
S. 21/37
6519
for extended
temperature range
Type 6519 for extended Ex m temperature range
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Ordering chart for valves in aluminium with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Seal mate-
Frequency
Article no.
Weight [g]
power [W]
QNn-value
Threaded
Pressure
rial body
Voltage/
Nominal
function
Orifice
Circuit
[l/min]
[V/Hz]
range
[inch]
[mm]
[bar]
port
air
5 1 3
230/UC x
5/3 WWL 9.0 FPM, NBR G ¼" 1500 2.5 - 10 1060 3 024/UC x
4 2
14 12 110/UC x
5 13 230/UC x
5/3 WWN 9.0 FPM, NBR G ¼" 1500 2.5 - 10 1060 3 024/UC 278223
4 2
14 12 110/UC x
5 13 230/UC x
1)
Junction box version on request x = on request
S. 22/37
6519
for extended
temperature range
Ordering chart for valves in stainless steel with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Frequency
Article no.
Weight [g]
power [W]
QNn-value
Threaded
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[l/min]
[V/Hz]
range
[inch]
[mm]
body
[bar]
Seal
port
air
Type 6519 Ex m - with moulded cable, 3 m long1)
5/2 WWH 4 2 8.0 PU, NBR G ¼" 1980 3 - 10 1370 3 024/UC x
14
12
110/UC x
5 1 3
230/UC 278219
5/2-bistable WWZ 8.0 PU, NBR G ¼" 1920 3 - 10 1680 3 024/UC 278246
4 2
14 12 110/UC x
5 1 3 230/UC x
5/3 WWL 8.0 PU, NBR G ¼" 1770 3 - 10 1680 3 024/UC x
4 2
14 12 110/UC x
5 13 230/UC x
5/3 WWN 8.0 PU, NBR G ¼" 1770 3 - 10 1680 3 024/UC x
4 2
14 12 110/UC x
5 13 230/UC x
1)
Junction box version on request x = on request
S. 23/37
6519
for extended
temperature range
Type 6519 for extended Ex i temperature range
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Note
+ ≥ lmin
+
These units may only be used in explosive atmospheres in the manner approved by the Federal Institute of Physics and Technology (PTB), i.e.,
the permissible maximum electrical values must be complied with. Suitable barriers and isolating modules are available for this.
The valve is intended for operation on 24 V DC outputs via the intermediate switching of a corresponding intrinsically-safe operating resource
(isolating module or barrier).
S. 24/37
6519
for extended
temperature range
Ordering chart for valves in aluminium with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
Threaded port
Seal material
current [mA]
Orifice [mm]
connection
voltage [V]
resistance
Article no.
coil [Ohm]
Weight [g]
air [l/min]
switching
QNn-value
Minimum
Minimum
Pressure
Nominal
terminal
function
Circuit
range
[inch]
body
[bar]
5/2 WWH 9.0 FPM, NBR G ¼" 1800 2.5 - 10 825 29 310 9 231452
4 2
14
12 23 481 11 231453
5 1 3
5/2-bistable WWZ 9.0 FPM, NBR G ¼" 2100 2.5 - 10 1280 29 310 9 231454
4 2
14 12 23 481 11 231455
5 1 3
5/3 WWL 9.0 FPM, NBR G ¼" 1500 2.5 - 10 1350 29 310 9 231456
4 2
14 12 23 481 11 231457
5 13
5/3 WWN 9.0 FPM, NBR G ¼" 1500 2.5 - 10 1350 29 310 9 231458
4 2
14 12 23 481 11 231459
5 13
Ordering chart for valves in stainless steel with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
Seal material
current [mA]
Orifice [mm]
connection
range [bar]
voltage [V]
resistance
Article no.
coil [Ohm]
Weight [g]
air [l/min]
switching
QNn-value
Threaded
Minimum
Minimum
Pressure
Nominal
terminal
function
Circuit
[inch]
body
port
5/2 WWH 8.0 PU, NBR G ¼" 1980 3 - 10 1520 29 310 9 231460
4 2
14
12 23 481 11 231461
5 1 3
5/2-bistable WWZ 8.0 PU, NBR G ¼" 1920 3 - 10 1970 29 310 9 231463
4 2
14 12
23 481 11 231464
5 1 3
5/3 WWL 8.0 PU, NBR G ¼" 1770 3 - 10 1970 29 310 9 231465
4 2
14 12
23 481 11 231466
5 13
5/3 WWN 8.0 PU, NBR G ¼" 1770 3 - 10 1970 29 310 9 231467
4 2
14 12
23 481 11 231468
5 13
S. 25/37
6519
for extended
temperature range
Type 6519 for extended NAMUR standard temperature range
Ordering chart for valves in aluminium with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Frequency
Article no.
Weight [g]
power [W]
QNn-value
Threaded
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[l/min]
[V/Hz]
range
[inch]
[mm]
body
[bar]
Seal
port
air
3/2 WWC 6.0 FPM, NBR G ¼" 780 3 - 10 540 2 024/DC 231469
2(A)
024/50 - 60 231470
12
110/50 - 60 231471
1(P) 3(R)
230/50 - 60 231472
5/2 WWH 4 2 6.0 FPM, NBR G ¼" 800 3 - 10 540 2 024/DC 231473
14 024/50 - 60
12
231474
5 1 3 110/50 - 60 231475
230/50 - 60 231476
5/2-bistable WWZ 6.0 FPM, NBR G ¼" 900 3 - 10 540 2 024/DC 231477
4 2
14 12 024/50 - 60 231478
110/50 - 60 231479
5 1 3
230/50 - 60 231480
S. 26/37
6519
for extended
temperature range
Ordering chart for valves in stainless steel with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Frequency
Article no.
Weight [g]
power [W]
air [l/min]
QNn-value
Threaded
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[V/Hz]
range
[inch]
[mm]
body
[bar]
Seal
port
3/2 WWC 6.0 PU, NBR G ¼" 1280 3 - 10 540 2 024/DC 231481
2(A)
12 024/50 - 60 231482
1(P) 3(R)
110/50 - 60 231483
230/50 - 60 231484
5/2 WWH 6.0 PU, NBR G ¼" 1060 3 - 10 540 2 024/DC 231485
4 2
14 024/50 - 60 231486
12
110/50 - 60 231487
5 1 3
230/50 - 60 231488
5/2-bistable WWZ 6.0 PU, NBR G ¼" 1050 3 - 10 540 2 024/DC 231489
4 2 024/50 - 60 231490
14 12
110/50 - 60 231491
5 1 3 230/50 - 60 231492
S. 27/37
6519
for extended
temperature range
Type 6519 for extended NAMUR Ex m temperature range
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Ordering chart for valves in aluminium with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
range [bar]
Frequency
Article no.
Weight [g]
power [W]
air [l/min]
QNn-value
Threaded
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[V/Hz]
[inch]
[mm]
body
Seal
port
5 1 3 230/UC x
1)
Junction box version on request x = on request
S. 28/37
6519
for extended
temperature range
Ordering chart for valves in stainless steel with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
connection
Frequency
Article no.
Weight [g]
power [W]
QNn-value
Threaded
Pressure
Voltage/
Nominal
function
material
Orifice
Circuit
[l/min]
[V/Hz]
range
[inch]
[mm]
body
[bar]
Seal
port
air
Type 6519 Ex m - with moulded cable, 3 m long1)
3/2 WWC 6.0 PU, NBR G ¼" 1280 3 - 10 960 3 024/UC x
2(A)
12 110/UC x
1(P) 3(R) 230/UC x
5/2 WWH 4 2
6.0 PU, NBR G ¼" 1060 3 - 10 960 3 024/UC x
14 110/UC x
12
5 1 3 230/UC x
5/2-bistable WWZ 6.0 PU, NBR G ¼" 1050 3 - 10 1260 3 024/UC x
4 2
14 12
110/UC x
5 1 3
230/UC x
1)
Junction box version on request x = on request
S. 29/37
6519
for extended
temperature range
Type 6519 for extended NAMUR Ex i temperature range
The maximum fluid temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K.
Note
+ ≥ lmin
+
These units may only be used in explosive atmospheres in the manner approved by the Federal Institute of Physics and Technology (PTB), i.e.,
the p
ermissible maximum electrical values must be complied with. Suitable barriers and isolating modules are available for this.
The valve is intended for operation on 24 V DC outputs via the intermediate switching of a corresponding intrinsically-safe operating resource (isolating
module or barrier).
S. 30/37
6519
for extended
temperature range
Ordering chart for valves in aluminium with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
QNn-value air
current [mA]
Orifice [mm]
connection
range [bar]
resistance
Article no.
coil [Ohm]
Weight [g]
voltage[V]
switching
Threaded
Minimum
Minimum
Pressure
Nominal
terminal
function
material
Circuit
[l/min]
[inch]
body
Seal
port
3/2 WWC 6.0 FPM, NBR G ¼" 780 3 - 10 690 29 310 9 231520
2(A)
12
23 481 11 231521
1(P) 3(R)
5/2 WWH 6.0 FPM, NBR G ¼" 800 3 - 10 690 29 310 9 231522
4 2
14
12 23 481 11 231523
5 1 3
5/2 bistable WWZ 6.0 FPM, NBR G ¼" 900 3 - 10 1140 29 310 9 231524
4 2
14 12
23 481 11 231525
5 1 3
Ordering chart for valves in stainless steel with manual override (without manual override on request)
All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity.
QNn-value air
current [mA]
Seal materi-
Orifice [mm]
connection
resistance
Article no.
coil [Ohm]
Weight [g]
voltage[V]
switching
Threaded
Minimum
Minimum
Pressure
Nominal
terminal
function
al body
Circuit
[l/min]
range
[inch]
[bar]
port
3/2 WWC 6.0 PU, NBR G ¼" 1280 3 - 10 1100 29 310 9 231526
2(A)
12
23 481 11 231527
1(P) 3(R)
5/2 WWH 6.0 PU, NBR G ¼" 1060 3 - 10 1100 29 310 9 231528
4 2
14
12
5 1 3 23 481 11 231529
5/2 bistable WWZ 6.0 PU, NBR G ¼" 1050 3 - 10 1550 29 310 9 231530
4 2
14 12
5 1 3 23 481 11 231531
S. 31/37
6519
for extended
temperature range 18
Accessories
18
Cable plug 2508 acc. to DIN EN 175301-803 Form A
Fixing screw
Included in delivery is a connector with flat seal and fixing screw.46
For other cable plug v ersions acc. to DIN EN 175301-803 Form A (previously DIN 43650)
27,5
18
with integrated circuitry, see datasheet Type 2508.
Flat seal
18
1,5
Dimensions Type 2508 [mm] M3
28
18 46
18
27,5
18
1,5
M3
46 28
27,5
18
1,5
M3
Ordering
28 chart for cable plug 2508
BN
[in mm]
Article
length
Cable
[mm]
no.
BU 12000 260893
5000 260892
GNYE 3000 260891
300 260890
Ex-Cable glands
(polyamide version included in delivery / surcharge applied for brass nickel plated version
Ex Approvals
Certification
Description
Identifica-
Article no
Drawing
Photo
tion
TL 29 - 37 mm
Brass.
L 6 mm
nickel- PTB 04 ATEX 1112 X, II 2 G Ex e IIC Gb,
773278 D 20
plated, IECEx PTB 13.0027X II 2 D Ex tb IIIC Db IP68,
6 - 13 mm SW 24 mm
E 27 mm
TL 36 - 45 mm
L 10 mm
Polyamide, PTB 13 ATEX 1015 X, II 2 G Ex e IIC Gb,
773277 D 20
7 - 13 mm IECEx PTB 13.0034X II 2 D Ex tb IIIC Db IP68
SW 24 mm
E 28 mm
Article no.
Descrip-
Photo
tion
Set SC02-AC10
Special wrench
293488
Service Manual
S. 33/37
6519
for extended
temperature range
Dimensions [mm]
WWH
E
Threaded port version D
12
WWH
G1/4
H
5.5
48
B
24
24
66
4.3
A
A
24 32 G1/4
30 50
E
Threaded port version D
12
WWH – Impulse, WWL,
WWN
G1/4
G1/4
5.5
66
B
H
48
24
24
H
4.3
5.5
A
48
B
A
A
G1/4
24 32
30 50
Version Variants A B D E H
Standard, Ex m Ex i Standard, Ex m Ex i Standard, Ex m Ex i
WWH Stainless 53.5 107 35 40.7 45 51 177.8 186.6
steel
WWH Aluminium 43.5 97 35 40.7 45 51 167.8 176.6
WWH – Impulse, WWL, WWN Stainless 53.5 107 35 40.7 45 51 248.6 266.2
steel
WWH – Impulse, WWL, WWN Aluminium 53.5 107 35 40.7 45 51 148.6 266.2
S. 34/37
6519
for extended
temperature range
Dimensions [mm]
WWC
NAMUR version
WWC E
D
12
WWC
D E
12 D
G1/4
44
24
HB
2
A
40
C
G1/4
44
24
B
25 25
32
44.35 40
A
40
C
25 32
WWH
44.35 E 40
D
12
NAMUR version Variant: stainless Variant: aluminium
WWH WWH steel
D E
12
44.35
G1/4
G1/4
H
G1/4
G1/4
44
44
H
24
C
C
44
44
A
24
12.5
C
C
25 32 10
A
44.35 40 14.5
12.5
25 32 10
44.35 40 14.5
Version Variants A B C D E H
Standard, Ex m Ex i Standard, Ex m Ex i Standard, Ex m Ex i
WWC Stainless 35 94 25 35 40.7 45 51 165 173.8
steel
WWC Aluminium 25 84 15 35 40.7 45 51 155 163.8
WWH Stainless 35 94 47 35 40.7 45 51 165 173.8
steel
WWH Aluminium 25 84 37 35 40.7 45 51 155 163.8
WWH – Impulse, WWL, WWN Stainless 35 94 47 35 40.7 45 51 236 253.6
steel
WWH – Impulse, WWL, WWN Aluminium 35 94 47 35 40.7 45 51 236 253.6
S. 35/37
6519
for extended
temperature range
Dimensions [mm]
WWH - Impulse. WWL. WWN
G1/4
G1/4
G1/4
10 12.5
44
B
H
25
44
44
24
B
40
C
C
32
C
14.5
A
64.8
44.35
G1/4
G1/4
Version Variants A B C D E H
Standard, Ex m Ex i Standard, Ex m Ex i Standard, Ex m Ex i
WWC Stainless 35 94 25 35 40.7 45 51 165 173.8
steel
44
44
steel
WWH Aluminium 25 84 37 35 40.7 45 51 155 163.8
12.5
WWH
10
– Impulse, WWL, WWN Stainless 35 94 47 35 40.7 45 51 236 253.6
steel
14.5
WWH – Impulse, WWL, WWN Aluminium 35 94 47 35 40.7 45 51 236 253.6
S. 36/37
6519
for extended
temperature range
Dimensions - Atex Approvals [mm]
Cable coil
D
Length acc. to
ordering information C
B A
6.2
m
in
R2
5
Junction box
68 F
27
E
M20x1.5 B
29.7
R84
dius
Turn ing ra
84.3
A 41.3
Coil size A B C D E F
5 32 20.5 46 68.8 99.8 174.7
6 40 23.5 52 74.8 102.8 177.7
To find your nearest Bürkert facility, click on the orange box www.burkert.com
In case of special application conditions, We reserve the right to make technical changes without notice.
please consult for advice. © Christian Bürkert GmbH & Co. KG 1801/15_EU-en_00891764
S. 37/37