Professional Documents
Culture Documents
Bateria Gd150-12 Kuhn
Bateria Gd150-12 Kuhn
GD150-12 12V150AH
GD SERIES-Deep Cycle Battery
Specification
Nominal Voltage 12V
Nominal Capacity(10HR) 150.0AH
Length 485 3mm (19.09 inches)
Width 170 2mm (6.69 inches)
Dimension
Container Height 240 2mm (9.45 inches)
Total Height (with Terminal) 240 2mm (9.45 inches)
Approx Weight Approx 41.1 Kg (90.61 Ibs)
Terminal T11
Container Mater ial ABS
160.8 AH/8.04A (20hr ,1.80V/cell,25℃/77℉)
Applications 150.0 AH/15.0A (10hr,1.80V/cell,25℃/77℉)
Rated Capacity 131.6 AH/26.3A (5hr,1.75V/cell,25℃/77℉)
Electric tools 119.3 AH/39.8A (3hr,1.75V/cell,25℃/77℉)
Vehicle in place of walking 96.9 AH/96.9A (1hr,1.60V/cell,25℃/77℉)
Lawn mowers Max. Discharge Current 1500A (5s)
Golf trolleys and golf cart
Internal Resistance Approx 2.5mΩ
Portable apparatus, lights and
Discharge : -15 50℃ (5 122℉)
instruments;
Operating Temp.Range Charge : 0 40℃ (32 104℉)
Electric toys
Storage : -15 40℃ (5 104℉)
Illumination light
Nominal Operating Temp. Range 25 3℃ (77 5℉ )
Fire alarms
Portable power Initial Charging Current less than 45.0A.Voltage
Cycle Use
Wheelchairs 14.4V~15.0V at 25℃(77℉)Temp. Coefficient -30mV/℃
Medical equipments. No limit on Initial Charging Current Voltage
Standby Use
13.5V~13.8V at 25℃(77℉)Temp. Coefficient -20mV/℃
40℃ (104 ℉) 103%
Capacity affected by
ISO ISO OHSAS Temperature
25℃ ( 77 ℉ ) 100%
86%
9001 14001 18001 0℃ ( 32 ℉ )
KUHN GD series batterys may be stored for up to 6 months
Self Discharge at 25℃(77℉) and then a freshening charge is required.
For higher temperatures the time interval will be shorter.
Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values.
www.kuhn.cl Page 1 of 2
Maintenance Free Deep Cycle Solar Battery
GD150-12 12V150AH
GD SERIES-Deep Cycle Battery
Dimensions
T11 Terminal
Unit: mm [inches]
20 [0.787]
140 2
170 2
M8 [0.315]
7 [0.276]
240 2
225 2
+ _
Dimensions (mm) 389 2
450 2 485 3
120
6.0
Terminal Voltage(V)
12.0
Charged Volume
100 0.1C 2.5
5.5 11.0
2.4 Charge Voltage
80 0.08C (Constant 2.45v/cell) 0.1C 0.054C
0.214C
5.0 10.0
2.3 0.365C
60 0.06C
After 50% Discharge 3.8C 2.6C 1.1C 0.646C
Charging Current
20 0.02C 2.1 (initial at 0.1c Amp) 4.0 8.0
0C
0 4 8 12 16 20 24 28 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
min H
Charging Time(hours)
Discharge Time
Temperature Effects in Relation to Battery Capacity Cycle Life in Relation to Depth of Discharge
T e st i ng co nd it i on
D is ch ar gi ng :c ur r en t 0 .1 7C (F V 1 . 7V /c el l );
120 C ha rg in g: cu rr en t 2 .4 5V /c el l , ma x. 0. 25 CA ;
C ha rg in g v o lu me :1 25 % o f di s c ha rg ed ca pa ci t y .
0.1CA
100 0.12CA 120
0.21CA
80 100
1CA
Capacity (%)
2CA 80
60 3CA
Capcity(%)
40 60
100% 50% 30%
DOD DOD DOD
20 40
0 20
-20 -10 0 10 20 30 40 50
0
Temperature(0C) 0 200 400 600 800 1000 1200 1400 1600 1800
Number of Cycles
40 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
3.Charged for 8~10hours at limted current 0.05CA .
20
Supplementary charge may often fail to recover the capacity.
0 The battery should never be left standing till this is reached.
0 2 4 6 8 10 12
Storage Time(Months)
KUHN GD BATTERIES
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/
specification are subject to modification without notice. Contact KUHN for the latest information.
www.kuhn.cl Page 2 of 2