UXL7-12

12V 7AH
Extended Life

UXL7-12 Physical Specification

Part Number: UXL7-12

Length: 151 ± 3 mm ( 5.94 inches )

Width: 65 ± 3 mm ( 2.56 inches )

Container Height: 93.5 ± 3 mm ( 3.70 inches )

Total Height (with terminal): 99 ± 3 mm ( 3.94 inches )

Approx Weight: Approx 2.45 Kg (5.40 Ibs)

Specifications
Nominal Voltage 12V
Nominal Capacity (10HR) 7AH
Terminal Type Standard Terminal F1
Optional Terminal F2
Container Material Standard Option ABS
Flame Retardant Option (FR) ABS (UL94:VO)
Rated Capacity 7.42 AH/0.37A (20hr,1.80V/cell, 25°C / 77°F)
7.00 AH/0.70A (10hr,1.80V/cell, 25°C / 77°F)
6.07 AH/1.21A (5hr,1.75V/cell, 25°C / 77°F)
5.53 AH/1.84A (3hr,1.75V/cell, 25°C / 77°F)
4.31 AH/4.31A (1hr,1.60V/cell, 25°C / 77°F)
Max Discharge Current 105.0A (5s)
Internal Resistance Approx 18.0mΩ
Discharge Characteristics Operating Temp. Range Discharge: -15 ~ 50°C (5 ~ 122°F)
Charge: 0 ~ 40°C (32 ~ 104°F)
Storage: -15 ~ 40°C (5 ~ 104°F)
Nominal Operating Temp. Range 25 ± 3°C (77 ± 5°F)
Cycle Use Inital Charging Current less than 2.1A.Voltage
14.4V ~ 15.0V at 25°C (77°F) Temp. Coefficient -30mV/°C
Standby Use No limit on Initial Charging Current Voltage
13.5V ~ 13.8V at 25°C (77°F) Temp. Coefficient -20mV/°C
Capacity affected by Temperature 40°C (104°F) 103%
25°C (77°F) 100%
0°C (32°F) 86%
Design Floating Life at 20°C 15 Years
Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is
required. For higher temperatures the time interval will be shorter.

Dimensions

F1 Terminal 151 1 43 1

4. 75( 0. 187)
-
3. 2( 0. 126)
1

+
94.5

6. 35( 0. 25)
100

0. 8( 0. 031)

65 1

Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

1
Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: info@ultracell.co.uk
www.ultracell.co.uk ISO9001
Constant Current Discharge (Amperes) at 25 0C (77 0F )
F.V/Time 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 9.03 7.53 6.42 5.25 3.97 3.33 2.12 1.68 1.36 1.10 0.97 0.77 0.661 0.368
1.80V/cell 11.5 9.10 7.59 6.19 4.61 3.73 2.32 1.81 1.46 1.18 1.04 0.82 0.700 0.371
1.75V/cell 12.7 9.9 8.17 6.43 4.79 3.90 2.40 1.84 1.49 1.21 1.07 0.84 0.707 0.375
1.70V/cell 13.8 10.6 8.58 6.69 4.98 4.02 2.50 1.89 1.53 1.24 1.09 0.85 0.714 0.382
1.65V/cell 14.9 11.3 9.12 7.06 5.10 4.16 2.57 1.98 1.58 1.28 1.11 0.86 0.729 0.386
1.60V/cell 16.2 12.1 9.71 7.45 5.32 4.31 2.65 2.04 1.63 1.32 1.14 0.87 0.736 0.389

Constant Power Discharge (Watts) at 25 0C (77 0F )


F.V/Time 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 17.0 14.3 12.3 10.2 7.76 6.53 4.20 3.34 2.71 2.20 1.93 1.55 1.33 0.741
1.80V/cell 21.5 17.1 14.4 11.8 8.96 7.28 4.55 3.57 2.88 2.35 2.07 1.65 1.41 0.747
1.75V/cell 23.2 18.4 15.3 12.2 9.21 7.58 4.70 3.62 2.94 2.40 2.12 1.67 1.42 0.753
1.70V/cell 24.7 19.4 16.0 12.6 9.55 7.80 4.88 3.72 3.01 2.46 2.16 1.69 1.43 0.767
1.65V/cell 26.5 20.5 16.8 13.2 9.70 8.00 4.99 3.86 3.10 2.52 2.20 1.71 1.46 0.776
1.60V/cell 28.1 21.5 17.7 13.8 10.05 8.24 5.13 3.96 3.19 2.60 2.24 1.73 1.47 0.779

Discharge Characteristics Float Charging Characteristics


2V 6V 12V Char ged Char ged Char ge
0
Batt ery Batt ery Batt ery Tem perature :25 C Volume Curre nt Voltage
V V V % XC A V
0
0.1C A-2.2 5V/ce ll te mperature25C
140
Terminal Voltage(V )

2.16 6.50 13.0

0.1 0
2.00 6.00 12.0 120
2.5 0 C HAR G E D V O LUME 15.0

1.84 5.50 11.0 100 0.0 8


0.1C 0.0535C C HAR G E V O LTAG E
0.263C 2.3 3 14.0
1.68 5.00 10.0 80
0.0 6
1.073C 0.62C
2.1 6 13.0
1.52 4.50 9.00 60
0.0 4
1.36 4.00 8.00 A F T E R 5 0% D IS C HA R G E
3.5C 2.4C 40 2.0 0 12.0
A F T E R 1 00 % D IS C HA R G E
0.0 2
1 2 4 6 8 10 20 40 60 100 200 400 600 1000 2000 Min
20
1.8 3 11.0
0.1 0.2 0.3 0.4 0.5 1 2 3 4 5 10 20 (Hours) C HA R G IN G C UR R E NT
0 0 0
0 4 8 12 16 20 24 28 31 36
Dis cha rge Tim e

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life

120
0.1 CA 10
100 0.1 7C A 8
6
0.2 5C A 5
%

80 4
Charging voltage :
2.25V/cell
C a pa c ity

3
Life expectancy(year)

60
2
40
1
20

0.5
-20 -10 0 10 20 30 40 50 60 20 30 40 50 0
C
68 86 104 122 O
F
0
Temper ature( C) Battery temperature

Self Discharge Characteristics

100 No supplementary required

100C A A (Carryout supplementary charge before use if 100% capacity is required.)


80
Remaining Capacity (%)

250C
60
B Supplementary charge required before use. Optional charging way as below:
1. Charged for above 3 days at limited current 0.25CA and constant voltage 2.25V/cell.
30 C
0
40 C 0

40 B 2. Charged for above 20 hours at limited current 0.25CA and constant voltage 2.25Vcell.
3. Charged for 8 ~ 10 hours at limited current 0.05 CA.
C
20

0 Supplementary charge may often fail to recover the capacity.


0 2 4 6 8 10 12
C The battery should never be left standing till this is reached.
Storage Time (Months)