Changing Cells:
Result Cells:
Notes: Current Values column represents values of changing cells at
time Scenario Summary Report was created. Changing cells for each
scenario are highlighted in gray.
General Input :- Coulmn NO.= 10
Flat Slab Input
Slab thk t 200 mm fy
cover 20 mm fc'
d 165 mm
fyt
DL 5 Kn/m2 Ln1
LL 5 Kn/m2 Ln2
Wu 14 Kn/m2 L1
L2
Normal weight concrete λ = 1
Column Dimensions
c_1(max face) 700 mm 0.7
c_2(min face) 350 mm 0.35
Punching Critcal Zone
b1 865 mm 0.865
b2 515 mm 0.515
b0(p) 2760 2.76
Interior Column
� 2.00
αs 40
Punching Shear Input
Vu 775.348 KN
Φ shear 0.75
(1+2/�)(√(𝑓^′ 𝑐)∗𝑏𝑜𝑑)/6
= 569250.000
(𝛼𝑑/𝑏𝑜+2)(√(𝑓^′
ΦVc =min. of 𝑐)∗𝑏𝑜𝑑)/12 = 624937.500
(√(𝑓^′ 𝑐)∗𝑏𝑜𝑑)/3
= 569250.000
2 If d>150mm & d>16ts We can use shear RFT.==> Can Use RFT.
Reduce Vc = 379.500 KN
Vn=Vu/Φ = 1033.798 KN
3 If Vn<3Vc can use shear RFT. OK
Av/s(req.) 13.22 mm
use Φ 18 254.47
No. Of Legs 2
Av = 2035.75 4sides
Sreq. = 154.01 = 15.40 cm
USE Φ 18 @ 8.25 cm
Vu= ΦVc
Vu = 775348.35 N
ΦVc = 103.13 N
X= = 1095.76 mm
X= = 109.58 cm
300 N/mm2
25 N/mm2
300 N/mm2
6.85 m
8.15 m
6.85 m
8.15 m
φVn = φVc)
N.G (Vu>ΦVc)
Ratio 1.36
8
10
12
14
16
18
20
Edge Column
� 1.00
αs 30
Punching Shear Input
Vu 783.683 KN
Φ shear 0.75
(1+2/�)(√(𝑓^′ 𝑐)∗𝑏𝑜𝑑)/6
= 473343.750
(𝛼𝑑/𝑏𝑜+2)(√(𝑓^′
ΦVc =min. of 𝑐)∗𝑏𝑜𝑑)/12 = 413015.625
(√(𝑓^′ 𝑐)∗𝑏𝑜𝑑)/3 = 315562.500
2 If d>150mm & d>16ts We can use shear RFT.==> Can Use RFT.
Reduce Vc = 210.375 KN
Vn=Vu/Φ = 1044.911 KN
3 If Vn<3Vc can use shear RFT. N.G(Can't Use RFT==>Incre
Av/s(req.) 16.86 mm
use Φ 18 254.47
No. Of Legs 2
Av = 1526.81 3sides
Sreq. = 90.56 = 9.06 cm
USE Φ 18 @ 8.25 cm
Vu= ΦVc
Vu = 783683.43 N
ΦVc = 103.13 N
X= = 1110.04 mm
X= = 111.00 cm
300 N/mm2
25 N/mm2
300 N/mm2
7.5 m
7.5 m
7.5 m
7.5 m
φVn = φVc)
N.G (Vu>ΦVc)
Ratio 2.48
8
10
12
14
16
18
20
Corner Column
� 1.00
αs 20
Punching Shear Input
Vu 783.894 KN
Φ shear 0.75
(1+2/�)(√(𝑓^′ 𝑐)∗𝑏𝑜𝑑)/6
= 409171.875
(𝛼𝑑/𝑏𝑜+2)(√(𝑓^′
ΦVc =min. of 𝑐)∗𝑏𝑜𝑑)/12 = 425296.875
(√(𝑓^′ 𝑐)∗𝑏𝑜𝑑)/3 = 272781.250
2 If d>150mm & d>16ts We can use shear RFT.==> Can Use RFT.
Reduce Vc = 181.854 KN
Vn=Vu/Φ = 1045.192 KN
3 If Vn<3Vc can use shear RFT. N.G(Can't Use RFT==>Incre
Av/s(req.) 13.39 mm
use Φ 16 201.06
No. Of Legs 2
Av = 804.25 2sides
Sreq. = 60.09 = 6.01 cm
USE Φ 16 @ 6.01 cm
Vu= ΦVc
Vu = 783894.21 N
ΦVc = 134.38 N
X= = 727.19 mm
X= = 72.72 cm
300 N/mm2
25 N/mm2
300 N/mm2
7.5 m
7.5 m
7.5 m
7.5 m
φVn = φVc)
N.G (Vu>ΦVc)
Ratio 2.87
8
10
12
14
16
18