You are on page 1of 2

Monocrystalline

KYL KYL-150M
36 CELL KYL-155M
KYL-160M
SERIES KYL-165M
KYL-170M

PROVEN QUALITY
IN A NEW DIMENSION

Durability
20.4% Durable PV modules, independently tested for harsh environmental
CELL EFFICIENCY conditions such as exposure to salt mist, ammonia and known PID risk
factors.
DURABLE

Advanced Glass
Our high-transmission glass features a unique anti-reflective coating
that directs more light on the solar cells, resulting in a higher energy
ANTI REFLECTION

yield.

Extended Size
Our large-format module facilitates system-level cost savings through
EXTENDED SIZE
reduced handling and installation times.

PID Resistant
Tested in accordance to the draft standard IEC 62804, our PV
modules have demonstrated resistance against PID (Potential Induced
Degradation), which translates to security for your investment.
PID-FREE
KYL 36 CELL SERIES
ELECTRICAL PERFORMANCE GENERAL CHARACTERISTICS
Electrical parameters at Standard Test Conditions (STC) Dimensions (L / W / H) 1480mm/680mm/35mm
Module type KYL- x xx M Weight 10.9kg
Power output Pmax W 150 155 160 165 170
Power output tolerances ΔPmax W 0 /+ 5
Module efficiency ηm % 15.2 15.6 16.2 16.6 17.1
PA C K A G I N G S P E C I F I C AT I O N S
Voltage at Pmax Vmpp V 18.0 18.3 18.4 18.5 18.6
Number of modules per pallet
Current at Pmax Impp A 8.33 8.47 8.70 8.92 9.14
Number of pallets per 40' container
Open-circuit voltage Voc V 21.4 21.7 21.8 22.0 22.3
Short-circuit current Isc A 8.96 9.11 9.35 9.54 9.68 Packaging box dimensions
(L / W / H)
STC: 1000W/m irradiance, 25°C module temperature, AM1.5g spectrum according to EN 60904-3.
2

Average relative efficiency reduction of 3.3% at 200W/m 2 according to EN 60904-1. Box weight

Electrical parameters at Nominal Operating Cell Temperature (NOCT)


Unit: mm 35
Power output Pmax W 109.0 112.6 116.3 119.9 123.5
Voltage at Pmax Vmpp V 16.2 16.5 16.6 16.7 16.8
Current at Pmax Impp A 6.73 6.83 7.01 7.18 7.35
BXI
Technologies
PV-bx2020c-5

Open-circuit voltage Voc V 19.5 19.8 19.9 20.0 20.1

380
Drainage holes
Short-circuit current Isc A 7.61 7.71 7.92 8.11 8.31 14
*
NOCT: open-circuit module operation temperature at 800W/m 2 irradiance, 20°C ambient temperature, 1m/s wind speed. 4-Ø9

740
THERMAL CHARACTERISTICS Mounting holes

Nominal operating cell temperature NOCT °C 46 +/- 2

Temperature coefficent of Pmax γ %/°C -0.42 5


2-Ø

1480
720
Temperature coefficent of Voc βVoc %/°C -0.32
Grounding holes
Temperature coefficent of I sc αIsc %/°C 0.05

Temperature coefficent of Vmpp βVmpp %/°C -0.42

O P E R AT I N G C O N D I T I O N S
638
Max. system voltage 1000 VDC

Max. series fuse rating 15A

30
Limiting reverse current 15A

Operating temperature range -40°C to 85°C


680
Max. static load, front (e.g., snow) 5400Pa

Max. static load, back (e.g., wind) 2400Pa


Ø9

Max. hailstone impact (diameter / velocity) 25mm / 23m/s


35
*14

C O N S T R U C T I O N M AT E R I A L S 30
Front cover (material / thickness) low-iron tempered glass / 3.2mm
SECTION
Cell (quantity / material / dimensions /
36 / monocrystal silicon / 156.75mm x 156.75mm /4 or 5
number of busbars) Warning: Read the Installation and User Manual
Frame (material / color / anodization color / in its entirety before handling, installing, and
anodized aluminum alloy / silver / clear / silicone operating Yingli Solar modules.
edge sealing)

Junction box (protection degree) ≥ IP65

Cable (length / cross-sectional area) 0.7m / 2.5mm2

Plug connector
MC4 / IP65
(type / protection degree)

• Due to continuous innovation, research and product improvement, the specifiications in this product information sheet are subject to change
without prior notice. The specifications may deviate slightly and are not guaranteed.
• The data do not refer to a single module and they are not part of the offer, they only serve for comparison to different module types.

Q U A L I F I C AT I O N S & C E R T I F I C AT E S
IEC 61215, IEC 61730, CE, MCS, ISO 9001:2008, ISO 14001:2004,
BS OHSAS 18001:2007, PV Cycle, SA 8000

www.kuhn.cl