Professional Documents
Culture Documents
XT-2000i
Actual Trends in Healthcare
University
Hospital
G e n e ra l
H o s p it a l
D is t r ic t D is t r ic t D is t r ic t
H o s p it a l H o s p it a l H o s p it a l
H e a lt h H e a lt h H e a lt h H e a lt h H e a lt h H e a lt h H e a lt h H e a lt h H e a lt h
C lin i c C lin i c C lin i c C lin i c C lin i c C lin i c C lin i c C lin i c C lin i c
Core-Lab
Satellite Satellite
Lab. Lab.
Satellite
Lab.
Sender/
Ward Sender/
Sender/ Sender/ Ward
Ward Ward
Sender/
Ward
Concept
Main Characteristics
.. Discrete analysis
48 hr sample stability
.. Windows 2000
SNCS (on line QC and remote maintenance: under
development)
. Introduction of XT-1800i
.. new algorithm
new functions
.. vice versa
except the technical limitation.
XE-2100
XE-2100
XE-2100L
Value
XE-2100L
XT-2000i
XE-2100
XT-1800i
XT-2000i
XE-2100L XT-1800i
Ver. UP
XT-2000i
Ver. UP
XT-1800i
Year
SYSMEX SINGAPORE PTE LTD XT-2000i Launch
Core and Satellite Lab.
Sysmex Sysmex
Core Lab
XE-2100 XE-2100
HST
Alpha
Same Reagents
Same Results
Sysmex Same Operation Sysmex
XT-2000i XT-2000i
Satellite Lab B
..Analysis principle
FCM (Semiconductor Laser)
..Reagent System
Network function
.. .TCP/IP connection
Research Parameter
IG
..
Research Screen
Q-Flag system
..
SNCS:
online QC/remote maintenance
Model Parameter
XT-2000i CBC+DIFF+RET
XT-1800i CBC+DIFF
XT-2000i XT-1800i
..
Theoretical Calculation
XT > SF-3000
..
Actual simulation
XT < SF-3000
Specifications
XT-2000i Parameters
. 33 Parameters
WBC, RBC, HGB, Hct, MCV, MCH, MCHC, PLT
RDW-CV, RDW-SD, MPV, PDW, P-LCR, PCT,
NEUT %, LYMPH %, MONO %, EO %, BASO %, IG %,
NEUT #, LYMPH #, MONO #, EO #, BASO #, IG #‚
RET %, RET #, LFR, MFR, HFR, IRF, PLT-fl
. 2 Histograms
RBC, PLT
. 5 Scattergrams
DIFF, WBC/BASO, RET, PLT-O, RET-EXT
.. Capillary Blood
Open Mode
40 µl
85 µl
.. Manual Closed
Automode
150 µl
150 µl
.. CBC
CBC + Diff
80 samples/h
80 samples/h
.. Minimised maintenance
Selectivity
.. Interpretive messages
Quality Control
Name Abbreviation
Cellpack EBK
Sulfolyser SLS
Stromatolyser 4DS FFS
Stromatolyser FB FBA
Stromatolyser 4DL FFD
Ret Search 2 Dye RED
Ret Search 2 Lyse RED
Central-PC
Work list
Barcode
Barcode reading
of each sample
Order information
• CBC
• CBC + DIFF
• CBC + DIFF + RET
Selective Analyse • CBC + RET
after ordering
Results
.. PIM software
TCM software: two unit connection with 1 x IPU*
• * only for the same model type available.
..
XT-2000” is not possible.
Sampler (50samples)
Bar coder reader (sampler)
XT Twin
SYSMEX SINGAPORE PTE LTD XT-2000i Launch
XT-2000i Twin Configuration
Main Unit
XT IPU
PIM
TCM
BCR
Sampler
TCP/IP O/M Basic soft
connection
accessory
Pneumatic unit
Analysis Principle
XT-2000i Multi Channel Analyser
Analysis
Block RBC/PLT HGB WBC RET
Flow Cytometry
WBC/BASO Diode laser - 1:50
WBC, Baso #‚ Baso %
Lymph #‚Lymph %,
Flow cytometry Mono #, Mono %,
4 Diff
Diode laser - 1:51 Eo #, Eo %,
Neut #‚ Neut %
Photo Multiplier
(Fluorescence Light)
Dichroic
Mirror
Photo Multiplier
(Side Scattered Light)
Semiconductor Laser
(λ = 633nm)
Flow Cell
Photo Diode
(Forward Scattered Light)
Laser Beam
(λ = 633nm)
2. DIFF-Scattergram
Lymph
Fluorescence
Neut + Baso
Eo
Ghos
t
Side Scatter
DIFF Scattergram
Fluorescence
Side Scatter
Atypical
Lymph Promyelo
Myelo
Abn. Lymph/
Blasts
Metamyelo
Band
2. DIFF-Scattergram
Lyse
WBC/BASO Scattergram
Baso
Forward Scatter
WBC
Side Scatter
2. DIFF-Scattergram
Staining:
Polymethine: RNA
Oxazine: DNA
SYSMEX SINGAPORE PTE LTD XT-2000i Launch
Ret Channel
RET Scattergram
RBC
Forward Scatter
RET
(LFR, MFR, HFR)
IRF
PLT-O
Fluorescence
2. DIFF-Scattergram
CELLPACK
(Sheath solution)
Sample
Aperture
C A
B
cells
aperture
1. SLS
2. Reaction Mechanism
Hemoglobin-Molecule
Hydrophobic
group
Heme
Hydrophilic
group
Globin
1. Hydrophobic groups of
SLS binds to globulin
2. 0xidation of Ferro: Fe2+ --> Fe3+
Flagging System
Flag
..
NEGATIVE
No abnormality
..
POSITIVE
One or more of the IP messages is
generated
..
ERROR
Classified as Functional abnormality
XT-2000i Launch
SYSMEX SINGAPORE PTE LTD
XT Flagging System
NEGATIV Report
E
Result
POSITIVE
ERROR
Two Types
..Abnormal IP Message:
Indicates that the sample is definitely
abnormal. The IP abnormal message criteria
..
can be set except for some items.
Suspect IP Message:
Indicates that there is a possibility that the
sample is abnormal.
..
IP messages are detected from:
Cell information
.. Fluorescence
Forward Scatter Light Flowcytometry
.. Scattergrams
Histograms
. WBC abnormal
Scattergram .. Blasts?
..
Immature Gran?
Neutropenia
Neutrophilia .. Left Shift?
..
Atypical Lympho?
Lymphopenia
Lymphocytosis .. Abn Lympho/L-Blasts?
..
RBC Lyse Resistance?
Monocytosis
Eosinophilia . NRBC?
.. Basophilia
Leukopenia
.. Anisocytosis
Microcytosis
. Fragments?
.. Macrocytosis
Hypochromasia
.. Anaemia
Erythrocytosis
..
PLT C(s) ?
PLT ABN Scattergram
Thrombocytopenia
. Thrombocytosis
Price
SF-
3000
K-4500
KX-21/
KX-21N
F series
Price
Pentra-60
AcT 5 Diff
ADVIA 70
ADVIA-120
CD-4000
Gen*S/LH750
Micros Pentra-120R
CD-1200
Act DiffⅡ
Price
Pentra-60 XT-2000i SE
AcT 5 Diff
ADVIA 70 XT-1800i
ADVIA-120
K-4500 CD-4000
Gen*S/LH750
KX-21/
KX-21N Micros Pentra-120R
CD-1200
F series Act DiffⅡ
Price
Sysmex
XE-2100
Specifications
XT-2000 i XE-2100
Parameters 30 32
Throughput CBC 80 samples/hour 150 samples/hour
XT-2000 i XE-2100
XT-2000 i XE-2100
CELLPACK use use
CELLSHEATH not use use
STROMATOLYSER- use use
FB
STROMATOLYSER- use use
4DL
STROMATOLYSER- use use
4DS
STROMATOLYSER- not use use
IM
SULFOLYSER use use
STROMATOLYSER- not use use
NR
RETSEARCH II use use
OS: Windows NT
XT-Series
Measure Sample Analysis the raw data
- differential
Sysmex
XT-2000i
- raw data
- flagging
Store the results
Features
Features
1.
2. Flowcytometry
3.
4.
Multi Channel Analyzer
Semi Conductor Laser
5.
6.
Network
Fully Automated RET analysis (XT-2000i)
7.
8.
Random access testing
Common operation & reagent system with XE
9.
10.
Hydrodynamic Focusing System
Effective Hematology Information
11.
12.
SNCS
X-bar-M Control
Q-Flag
Flowcytometry
Principle in Hematology
.. Resistance
Optical Measurement
. Scatter light
Information
Side- Granularity
scatter Internal Cell Structure
. Fluorescence
..
Light source:
Tungsten lamp
..
He-Ne laser
Argon laser
Semiconductor laser
Forward- Side-
scatter scatter Fluorescence
Tungsten lamp
He-Ne-Laser
Argon laser
Semi conductor
laser
Definition:
Argon laser
. Wavelength λ = 488 nm
Staining (RET)
Semiconductor Laser
. Wavelength λ = 633 nm
Staining
..Diff
Reticulocytes
What is so special on it ?
What is so special?
1 2
10
7
4
5 6
.
8
7
4 Cytoplasm (3)
5 6
- Mitochondria (5) energy factory no RNA/DNA
- Golgi machine (4) pack up enzymes no RNA/DNA
- Endoplasmatic Reticulum (10) is a membran
structure with Ribosome (RNA) for protein
synthesis (not in RBC)
- Lysosomen (8) Granula no RNA/DNA, enzymes
Semiconductor Laser
Fluorescence Flow Cytometry
Optical System
Photo Multiplier
(Fluorescence Light)
Dichroic
Mirror
Photo Multiplier
(Side Scattered Light)
Semiconductor Laser
(λ = 633nm)
Flow Cell
Photo Diode
(Forward Scattered Light)
.
Feature
Long-life Laser
. . Saves money
Quick start-up
. . Stat samples
Compact
. . Save money
High stability
. Less maintenance cost
..
Useful information
IRF, LFR, MFR, HFR
..
bone marrow suppression
recovery in terms of erythropoesis
Atypical Lymph
Feature
X
Fluorescence PLT
XE (PLT-o) x 10 ^9/L
120 120
XE (PLT-i) x 10 ^9/L
90 90
60 60
30 30
0
0
0 30 60 90 120 150 0 30 60 90 120 150
RBC ratio x 10 ^9/L RBC ratio x 10 ^9/L
Results
No
PLT-I, unreliable PLT-I Result
Yes
No
PLT-O, unreliable PLT-O Result
Yes
In case of MDS:
dysplastic Erythrocytes (Fragments)
dysplastic Platelets (degranulated)
IG Count
IG Count
.. IG:
promyelocyte
.. myelocyte
metamyelocyte
Maturation of neutrophil
IG
Promyelo
Myelo
Metamyelo
Band
35
15
10
0
0 5 10 15 20 25 30
XE-2100 IG%
Atypical Lymph
Diff Scattergram
Atypical
Lymph Promyelo
Myelo
Abn. Lymph/
Blasts
Metamyelo
Band
Activated
B-Lymphocytes
..
Blast or Blast-like
ALL or AML
NHL (IB or CC-CB)
..
Large Lymphocytes
Activated T-Cells
..
Activated B-Cells
O-Lymphocytes
NHL all kinds.
SYSMEX SINGAPORE PTE LTD XT-2000i Launch
Comparison: XT vs. ADVIA
The result was Other: 11.5%, LUC: 10.8% and manual: 9% respectively,
it showed excellent correlation.
Network capacity
Network
XE-2100
Room A
NETWORK
PC room
Doctor’s room
Room C
Room B
Quality Control
.. 24 files for either x bar or L-J
1 file for x bar M
.. Error Detection
Error Prevention
X-bar-M Control
Patient Moving Average
..
Monitors stability over time of:
Instrumentation
..Reagents
Technique
..
Use of routine samples
Fresh blood, cells without fixation, optimal
.
to check lyse processes
NO additional costs, because the control runs
in the back ground with routine samples
.
..
no manual handling
Optimal controlling of reagents
especially after reagent change
Online QC
On-line QC
.. IQC
Available anytime, but
if any abnormality found...
.. Instrument condition?
Control Blood Problem?
EQC
Reproducibility flag
1111
When SDI increased or decreased
continuously 6 times
Remote Maintenance
Remote Service
Clinical
Labs
Line for
Remote Support
Line for
Remote Support Sysmex
Support
Center
..
Real-time random access testing
Quick report
. Cost saving
CBC
CBC + DIFF
CBC + DIFF + RET
CBC + RET
XE / XT Family Concept
Operation & reagent system with XE
..Solution for
HST (XE) series: Core lab.
Core Lab
Same Reagents
Same Results
Same Operation
Hydrodynamic Focusing
Hydrodynamic Focusing System
..
New system
Compact
CELLPACK
(Sheath solution)
Sample
Aperture
Q-Flag
Unique Q-Flag System
..
effectively.
Quantitative monitoring of suspect flags:
Blasts?
.. Imm Gran?
Left Shift?
.. Atypical Ly?
Abn Ly/Blasts?
.. RBC Lyse Res?
RBC Agglut?
.. Turb/HGB?
HGB Defect?
..Fragments?
PLT Clumps?
IP Message
BLASTS ? BLASTS ?
300 300
200 200
100 100
Red, if
above 100
Green, if 80 250
below 100
Numerical value of the bar height
Negative Positive
example example
Degree of the
abnormality Trigger
level
3. Repitition of steps 1 and 2 until the values are stabil (max. 5 times), I.
e. the centroides are in a fixed position.
4. If the differences are not stable after the 5. repetition, there will be no
separation of WBC populations (grey area).
It’s up to us to choose :
.. Images or Perception
Customer Target Groups
.. Competitor Target
Core Strategy
.. Appealing Software
Unique menu of clinically relevant parameters
.. PLT-fl
.
IG
Fluorescence : ‘brightest’ hematology system
. Network connectivity
. compact
.
quality
True Selectivity : random access profiling:
CBC, CBC+DIFF, CBC+DIFF+RET,
CBC+RET
..
efficiency
New parameters: IG, PLT-fl, RBC-O
a world of new important information
.. the Scientist
the Altruist
.. IG % and IG #
80 % of all diseases have an increased IG
.. PLT-fl
Monitoring of Anemia
SYSMEX SINGAPORE PTE LTD
New Parameter: RBC-Y
XT-2000i Launch
and RET-Y
Target Group: the Altruist
.. Online Maintenance
Online Application Support
.. Used to be Nr. 1
No random access selectivity
.. No IG
No innovations
.. A newcomer
No random access selectivity
.. No IG
No Dual System
. Not fast
.. powerful QC-package
adjust screens to his needs: flexibility