TENDON ELONGATION CALCULATION

UTRACON STRUCTURAL SYSTEMS PVT LTD


PROJECT: (a) Coeff. of Friction, u =
PROPOSED MAGNUM GLOBAL PARK, SECTOR - 58, GURGAON ,HARYANA 0.200 (c) Area of Strand = 140 mm2 (e) Prestressing Force = 195.5 kN
LOCATION PTB-1,2ND FLOOR PT BEAM (b) Wobble Factor, k = 0.001 (d) Mod. of Elasticity = 195 kN/mm2
DWG NO : 190708/SD/2-PB3 R-D 26.08.2019 (strand) DATE : 11-Jul-19
STAGE : 1 PAGE : 1
Tendon Length 1 or 2 End Factor s Angular Exponential
No. (m) end Front Rear P(I)
Deviation Constant d1 d2 d
P(O)
stressing Y1 X1 Y2 X2 Y3 X3 Y4 X4 Y5 X5 Y6 X6 Y7 X7 Y8 X8 Y9 X9 Y10 X10 Y11 X11 Y11 X11 Y12 (radian) (mm) (mm) (mm)

T-22 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-24 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-26 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-27 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-28 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-30 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-32 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8
T-34 28.465 2 1 1 760 750 760 12560 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 940 60 7365 760 270 760 0.603 0.861 189.8 7.1 196.8