You are on page 1of 1

Chemical Engineering Calculations

Pump Sizing Calculation


https://checalc.com/calc/pump.html

Project re Developed By ewr


Date 2019-10-24 Reviewed By rwe
Revision 0 Approved By rwe

Data
Flowrate liter/h 1500 Vapor Pressure barg 1.00
Density kg/m³ 1000 Pump Efficiency % 80.00
Viscosity cP 0.800

Hydraulic Data
Suction Discharge
Operating Pressure barg 1.00 5.00
Static Head m 0.500 5.00
Equipment Loss bar 0.100 2.00
Length m 5.00 2000
Pipe Selected 2", Thickness 0.375 2", Thickness 0.375
Pipe Inside Diameter inch 1.63 1.63
Velocity m/s 0.311 0.311
Reynold's Number 16067 16067
Pipe, ΔP bar/100 m 0.0348 0.0348
Pressure at Pump Suction / barg 0.941 8.34
Discharge

Pipe Fitting Loss


Suction Discharge
Fittings # K ΔP # K ΔP
Elbows, 90LR 2 0.37 0.00 100 0.37 0.02
Elbows, 45LR 2 0.27 0.00 100 0.27 0.01
Tees, Thru 2 0.82 0.00 100 0.82 0.04
Tees, Branch 2 1.34 0.00 100 1.34 0.07
Ball Valve 2 0.27 0.00 10 0.27 0.00
Butterfly Valve 0 0.45 0.00 10 0.45 0.00
Gate Valve 0 0.18 0.00 1 0.18 0.00
Globe Valve 0 6.55 0.00 0 6.55 0.00
Check Valve 2 2.52 0.00 10 2.52 0.01
Plug Valve 2 0.47 0.00 0 0.47 0.00
Pipe Entrance / Exit 0 0.51 0.00 1 1.00 0.00
Total ΔP, bar 0.00587 0.152

Result
Differential Pressure bar 7.40 Pump BKW kW 0.385
Differential Head m 75.49 NPSH Available m -0.598
Hydraulic Power kW 0.308

Downloaded on 10/24/2019, 8:53:29 AM from checalc.com Page 1 of 1