You are on page 1of 12

20-inch Normal Case description

Data Input
Flowline Properties
Internal pressure Pi Pa
Pipe OD D pipe mm
Pipe wallthickness t pipe mm
Pipe Density r pipe kg/m3
Pipe Youngs Modulus E Pa
Internal liner thickness til mm
Corrosion coating thickness tcc mm
Concrete thickness t crt mm
Marine growth thickness t mg mm
Internal liner density r lin kg/m3
Corrosion Protection density r pp kg/m3
Content density r con kg/m3
Concrete density r crt kg/m3
Marine growth density r mg kg/m3
water density rw kg/m3
gap under pipeline e mm
Ambient Temperature T amb C
Operation Temperature T op C
Effective residual lay tension Heff N
Effective axial force release Seffmax %
Temperature expansion coefficient ae C-1
Poisson ratio v
SMYS Pa
Environmental Data
Water depth WD m
Trench depth d mm
Steady Current Uc m/s
Significant - Wave particle velocity Uw m/s
Significant - Wave particle accleration Uw dot m/s2
Significant - Wave period Tz s
Maximum - Wave particle velocity Uw_max m/s
Maximum - Wave particle accleration Uw dot_max m/s2
Maximum - Wave period Tz_max s
Relevant soil thickness (table 7.2) Su kN/m2
Additional Input Data (DNV RP F105 and OS F101)
Safety Factor-Inline gin
Safety Factor-cross flow gcr
Safety factor on stress range (2.6) gs
Safety factor on natural frequency gf
Safety factor on damping gk
Safety factor on onset of Vr gon
Structural damping (4.1.8) zstr
Soil damping (4.1.8) zsoil
hydrodynamic damping (4.1.8) zh
Concrete Stiffness Coefficient CSF
Inline Static deflection (6.8.2) d m
Pressure load effect factor (5.D300) γp
Usage factor for equivalent stress check (12.F1200) η
Boundary Condition
Boundary Condition C1 (6.7.8) C1
Boundary Condition C2 (6.7.8) C2
Boundary Condition C3 (6.7.8) C3
Boundary Condition C4 (6.7.8) C4
Boundary Condition C5 (6.7.8) C5
Boundary Condition C6 (6.7.8) C6
Calculation
Calculated General Values
Pipe Drag Diameter D mm
Moment of Inertia Ipipe m4
Current flow velocity ratio Sig. wave (4.1.6) a
Current flow velocity ratio dominant wave (4.1.6) a max
Mass of pipe m pipe kg/m
Internal liner mass m il mm
Corrosion coating mass m cc mm
Concrete mass m crt mm
Marine growth mass m mg mm
content mass m ct mm
total mass m pipe kg/m
Buoyancy B kg/m
Submerged weight of pipe Ws kg/m
Span gap ratio e/D
Relative Trench depth (4.4.9) ∆/D
Added mass coefficient CA
Added mass pipe MA kg/m
Effective mass (6.7.3) me kg/m
Eksternal pressure Pe Pa
Pressure difference ∆p Pa
Internal area (bore) (6.53) Ai m2
External pipe area (6.53) Ae m2
Pipe cross section area Ap m2
Temperature difference ∆T C
Effective Tension (6.5.3) Seff N
Total damping ratio zT
Ks
Stability parameter (4.1.7)
Ksd
Keulegan Carpenter number KC
Keulegan Carpenter number max KCmax
VIV Inline Span Length
Euler Buckling Load (6.8.2 & 6.8.8) PE N
Inline onset value for reduced velocity V in
R,onset m/s
b
Leff/L
Leff
fundamental natural frequency

EI  S efef  d 
22

ff00  C
C11.. 1  CSF .1  C 22 .  C 33   
m ee L44eff  PEE  D  
eff

Inline natural frequency

Uc  L / D  g IL
f 0, IL  .1  . .g f
VRIL,onset .D  250  a
Inline screening criteria
Span Length for inline flow VIV LVIV in m
VIV cross flow Span Length
Euler Buckling Load (6.8.2 & 6.8.8) PE N
Seabed correction factor yproxi,onset
spesific mass correction factor ymass,onset
current wave correction factor ya,onset
trench correction factor ytrench,onset
Cross flow onset value for reduced velocity VcrR,onset m/s
Deflection load per unit length (6.8.7) Q N/m
Static deflection (6.8.7) d m
Soil Stiffness K
b
Leff/L
Leff
Cross flow natural frequency
UUc c UUw w
CF 
f 00,,CF .g .g CF.g .g F
VVRCF
CF
. D CF F
, onset . D
R, onset

fundamental natural frequency

EI  S ef  d  
2

f 0  C1 . 1  CSF 
. 1  C2 .  C3  
4
crossflow screening criteriam e L eff
 P  D  
 E

Span Length for cross flow VIV LVIV cr m


Ultimate Limit State Cross Flow Span Length
Euler Buckling Load (6.8.2 ) PE N
Static (vertical) deflection (6.8.7) d m
Span natural frequency cross flow (6.7.2 ) f0,cr Hz
Reduced cross flow velocity (4.1.4) max. wave VcrR,max m/s
Cross flow response value (4.4.4) Az/D
Cross flow Unit Stress Amplitude (6.8.5) A cr Pa
Cross flow reduction factor (4.4.10) Rk
Cross flow VIV stress range (4.4.3) S cr_cr Pa
Dynamic stress cros flow (2.5.4) σcr
R,dyn Mpa
Basic drag coeff in oscilalatory flow (5.4.5) Cd,o
Drag Correction factor for pipe roughness (5.4.7) Ψ.k_CD
Drag Correction factor accounting for the sea bed proximity (5.4.6) Ψ.proxi_CD
Drag Correction factor accounting for the effect of pipe in a trench Ψ.trench_CD
Drag Amplification factor due tocrosflow vibration (5.4.9) Ψ.A_CD
Drag coefficient (5.4.4) Cd
Inertia coefficient (5.4.11) C M0
Inertia Correction factor for pipe roughness (5.4.12) Ψ.k_CM
Inertia Correction factor accounting for the sea bed proximity (5.4 Ψ.proxi_CM
Inertia Correction factor accounting for the effect of pipe in a tren Ψ.trench_CM
Inertia coefficient (5.4.10) CM
Drag force term (5.4.1) gD Kg/m
Inertia force term (5.4.1) gI Kg/m
Static horizontal load per unit length (6.8.7) Max. wave Q hor_max N/m
Resultant lateralstatic loading Q N/m
Static cross flow bending moment (6.8.6) M cr
R,sta Nm
Static cross flow bending stress (6.8.6) σcrR,sta Pa
Hoop stress σh Pa
True steel wall axial force Ntr Pa
Wall axial stress (2.5.8) σN Pa
Total axial stress (2.5.8) σL Pa
Von misses stress σe Pa
yield stress (table 5.2 F101) fy Pa
b
Leff/L
Leff
Cross flow ULS screening criteria
Span Length for cross flow ULS LULS cr m
Ultimate Limit State Inline Flow Span Length
Euler Buckling Load (6.7.2 ) PE N
Span natural frequency inline (6.7.2 ) f0,in Hz
Reduced inline velocity (4.1.4) max. wave VinR,max m/s
Inline response value (4.3.6) Ay/D
inline Unit Stress Amplitude (6.8.5) A in Pa
Amplitude reduction in dominant waves (4.3.8) ya,in
Inline VIV stress range (4.3.3) S in Pa
Static (vertical) deflection (6.8.7) d m
Cross flow response value (4.4.4) Az/D
Cross flow Unit Stress Amplitude (6.8.5) A cr Pa
Cross flow reduction factor (4.4.10) Rk
Cross flow VIV stress range (4.4.3) S cr_in Pa
Drag coefficient (5.4.4) Cd
Inertia coefficient (5.4.10) CM
Drag force term (5.4.1) gD Kg/m
Inertia force term (5.4.1) gI Kg/m
Static horizontal load per unit length (6.8.7) Max. wave Q hor_max N/m
Resultant lateralstatic loading Q N/m
Static inline bending moment (6.8.6) MinR,sta Nm
Static inline bending stress (6.8.6) σinR,sta Pa
Hoop stress σh Pa
True steel wall axial force Ntr Pa
Wall axial stress (2.5.8) σN Pa
Dynamic stress cros flow (2.5.4) σin
R,dyn Mpa
Total axial stress (2.5.8) σL Pa
Von misses stress σe Pa
yield stress (table 5.2 F101) fy Pa
b
Leff/L
Leff
Cross flow ULS screening criteria
Span Length for inline flow ULS LULS in m

Summary Case description

Span Length for inline flow VIV LVIV in m


Span Length for cross flow VIV LVIV cr m
Span Length for cross flow ULS LULS cr m
Span Length for inline flow ULS LULS in m
Buckling croteria (6.8.1)
Overall maximum allowable span length Lallow m
Operation

9652660.000
508.000
15.900
7850.000
207000000000.000
0.000
6.000
35.000
12.000
0.000
1300.000
60.000
3043.000
1234.000
1025.000
550.000
14.900
48.900
205000.000
0.000
0.0000117
0.300
448000000.000

94.000
0.000
0.900
0.249
0.126
12.400
0.483
0.244
12.440
12.500

1.100
1.100
1.300
1.200
1.150
1.200
0.005
0.010
0.000
0.900
0.000 ignored by dnv
1.050
0.500

1.570
1.000
0.800
4.930
0.125
0.013

614.000
0.0007449
0.784
0.651
192.961
0.000
12.595
185.700
28.005
10.686
429.948
365.377
64.571
0.896
0.000
0.972
295.007
724.955
945193.500
8707466.500
0.178
0.034
0.025
34.000
-2439443.102
0.015
0.294
0.255
5.019
9.786

3212561.430
0.833
0.852
1.000
30.000

0.544

2.384

-1.840
30.000 skenario

3212561.430
1.000
1.000
1.167
1.000
2.918
633.441
0.095
2570.000
0.852
1.000
30.000
0.846

0.565

0.281
30.000 skenario

3212561.430
0.095
0.544
4.141
0.700
650953688.854
0.962
1139344147.213
569672073.606
1.446
0.989
1.000
1.000
1.000
1.431
1.299
1.011
1.000
1.000
1.313
450.199
398.406
553.598
841.260
296117.734
100978258.342
134746674.989
-752677.091
-30620222.053
640030109.895
584425597.310
430080000.000
0.852
1.000
30.000
-369385597.310
30.000 skenario

5019627.234
1.242
1.813
0.000
1017115138.834
0.503
0.000
0.018
0.700
1017115138.834
0.962
1780225230.020
1.431
1.313
450.199
398.406
135.078
647.684
90722.740
30937101.106
134746674.989
-752677.091
-30620222.053
890112615.010
920297039.024
860869525.797
430080000.000
5.007
1.000
24.000
-645829525.797
24.000 skenario

Operation Corroded

30.000
30.000
30.000
24.000
CONVERGENCE
24.000

You might also like