You are on page 1of 18

DATA SHEET

V5812G

Compact GPON OLT

Humax Village 6F 11-4, Sunae-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-825, KOREA


Data Sheet
V5812G

1 Product Overview
V5812G is a compact GPON Optical Line Terminal (OLT) with a height of only 1U. This sys-
tem is suitable for access lines used for Ethernet leased line services.

The GPON technology adds new features and functionality targeted at improving perform-
ance and interoperability, and adds support for new applications, services, and deployment
scenarios. Among these changes are improvements in data rate and reach performance,
diagnostics, and stand-by mode, to name a few.

The V5812G introduces a point-to-multipoint concept with the GPON technology, which en-
ables a cost-effective FTTx service. The reason why GPON is considered as a cost-
effective solution is its usage of a passive splitter rather than an active switching system.

The benefits of the passive splitter are as follows:


• No power supply / maintenance is needed.
• The splitter does not need any fiber optic transceiver. The number of fiber optic
transceivers in the network is minimized.

The V5812G provides four GPON ports on the front panel, each delivering 2.488Gbps
downstream and 1.244Gbps upstream. Each GPON port supports a pluggable SFP laser
module that allows selection of the best speed and power to meet network requirements. It
is comprised of 8 electrical and optical combo GE interfaces as uplink towards the core
network and these interfaces can be used either to cascade other switches or to connect to
a collocated DSLAM. The MGMT and console interface is located on the most left of the
front panel with embedded LED for LNK/ACT and TX/RX indication respectively. They are
for use of equipment management via remote access or CLI.

MGMT Interface
(10/100Base-TX) 4 x GPON Interfaces

Operating LED Console Access 8 x GE uplink Interfaces (combo type)


(RS232) 100/1000Base-X (SFP) or 10/100/1000Base-T (RJ45)

Figure 1 Front View of V5812G

Item Function Connector Type

Operating LED Indicator for system operating status including power, fault detection -
and booting state.
CONSOLE CLI access to configure the functions for system operation RJ45 (RS232)
MGMT Outband TMN-OS Interface RJ45
Subscriber i/f 4 x GPON ports SFP
Uplink i/f 8 x 100/1000Base-X or 10/100/1000Base-T combo type ports SFP or RJ45

Table 1 Front Access Interfaces of V5812G

Page 2 of 18
Data Sheet
V5812G

The V5812G has two Power Supply Unit (PSU) mounting slots on the rear panel. Each
PSU is comprised of single DC or AC power input. For power redundancy, user can equip
dual PSUs into 2-slot. Install an appropriate PSU between AC type and DC type according
to your installation environment.

Figure 2 Rear View of V5812G

1.1 System Architecture


V5812G is a compact GPON Optical Line Terminal (OLT) that is comprised of GPON OLT
4-port modules with SFP GPON OLT transceiver. Up to four GPON links can be serviced
through the development system’s 8 Gigabit Ethernet interfaces as combo uplink ports. You
can use an uplink interface as an optical (1000Base-X, SFP) port or electrical
(10/100/1000Base-T, RJ45) port depending on the type of network it connected to..

With performance of a non-blocking switching capacity of up to 36 Gbps switching capacity


and 26.8 Mpps throughput, the V5812G provides high speed networking environment.

For GPON, the PON layer is terminated on the interface unit and translated to Ethernet up-
link to be transported through an Ethernet/IP environment. For improved system reliability, it
adopts the design of redundancy architecture with dual power supplies.

The power feeding of the V5812G is provided by Power Supply Unit (PSU). Dual PSUs can
be installed to guarantee constant system running. If power A’s input fails, the system can
be automatically switched to the other power B’s input and normal operations of the system
are not affected.

1.2 Service Scenario


A PON consists of an Optical Line Termination (OLT) located at the Central Office and a set
of Optical Network Units (ONUs) or Optical Network Terminals (ONTs) located at the cus-
tomer’s premises. Between them is the optical distribution network (ODN) comprising of fi-
bers and passive optical splitters or couplers. A splitter is a device that divides an optical
signal into two or more signals. OLT connects the PON to the IP network, controls and
manages the PON clients. ONU (ONT) connects the user specific network to PON. The
ONT can be occupied by a single subscriber and also can be a gateway of the local net-
work.

Page 3 of 18
Data Sheet
V5812G

Optical Distribution Network

User Side Central Offic

Core Network

Splitter
Shared OLT
User Fiber

ONTs
(ONUs)

Figure 3 Optical Distribution Network by PON Architecture

The V5812G is a network element, which includes the necessary service adaptation func-
tions to support the delivery of all types multiple services, such as Ethernet, IP telephony,
and video services.

The V5812G GPON OLT system is one element of this end-to-end solution, however
Dasan Networks is able to provide the complete next generation broadband access net-
work and video integration solution, where full interoperability is ensured. Up to 64 termina-
tion points for GPON can be attached to an OLT via passive optical splitter.

There are different possible deployment topologies for GPON networks, which differentiate
from each other basically from the place the optical fiber is terminated. Depending on the
subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber
to the Home), FTTB (fiber to the Building), FTTN (fiber to the neighborhood) or FTTC (fiber
to the Curb). In case of very high bandwidth requirement per user, scenarios without split-
ters offering 2.5Gbps/1.25Gbps (downstream/upstream) data rate can also be deployed by
connecting only the single user on a GPON port.

Street Curb or
Cabinet
HDTV

Central Office
VoIP

Shelf-based
DSLAM
PC

OLT FTTC / FTTN HDTV

VoIP

IP DSLAM OLT
ONU PC

Server FTTH

VoIP

L2 Switch/
PC
ONU

FTTB

Figure 4 FTTx Service Deployments of GPON OLT

Page 4 of 18
Data Sheet
V5812G

1.3 Component Options for V5812G


SFP Options
The following different optical SFP modules are available and can be inserted into the dedi-
cated slots. Each SFP module contains one port.

SFP Module Description

SFP-GE-SX SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX10 SFP GE LX10
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX20 SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX40 SFP GE LX40
- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C

Table 2 SFP Modules

SFP Module Description

SFP-GPON-OLT20 SFP GPON OLT


-. Wavelength: 1490nm/1310nm / Distance: 20km / Mode: singlemode
-. Connector: SC/PC / Data rate: 2.488Gbit/s (Up), 1.25Gbit/s (Down)
-. Core type : Single Core / Operating Temperature : -40 °C ~ 85 °C

Table 3 SFP Modules for GPON

Other types of SFP module can be also available upon customer request.
i
Power Options
Name Description Maximum
quantity

PSU_AC_V5812G AC_power supply unit for V5812G 2


PSU_DC_V5812G DC_power supply unit for V5812G 2
PSU_blank panel Blank panel for power supply unit 2

Table 4 Power Options

Page 5 of 18
Data Sheet
V5812G

2 Product Features and Benefits


V5812G supports the following main features.
• GPON functionality
• Power redundancy
• Non-Stop Forwarding (NSF)

Feature Benefits

GPON Functionality - provides substantially higher efficiency as a transport network


- delivers simplicity and superb scalability for future expansion in supporting
additional services
- offers the lowest cost system for all modes of operation
Power Redundancy - provides non-stop network services including forwarding IP messages, ensur-
ing QoS, etc.
- meets carrier’s requirements for high reliability
Non-Stop Forwarding - improves the network reliability by reliable data forwarding
- simply deployed by the routing protocols (RIP, OSPF, BGP) with graceful restart
capability

Table 5 V5812G Features and Benefits

2.1 GPON Functionality


The Gigabit-capable Passive Optical Network (GPON) is a high-speed optical access
method that has been defined in ITU-T Recommendation G.984. GPON carries a two-fold
promise of both higher bit rates and higher efficiency when carrying multiple services over
the PON.

GPON system of V5812G provides the network services at no extra cost, while EPON sys-
tems require additional adaptation equipment for TDM. It also offers much more available
bandwidth for the entire range of applications. The V5812G introduces a point-to-multipoint
concept with the several GPON mechanisms, which enable the efficient and flexible FTTx
services.

PON Benefits The PON provides the following advantages in general:


♦ Minimal maintenance (only passive splitter)
♦ Low deployment and maintenance costs
♦ High scalability of full-service solutions
♦ Deployments of FTTx environments
♦ Savings in the fiber infrastructure due to the lowest number of fibers required

GPON Benefits The GPON provides the following advantages in specific:


♦ Support a very high fiber splitting factor of up 1:64 (max. 1:128)
♦ Support a very high bandwidth (bit rate up to 2.5Gbit/s for DS)
♦ Use in multi-service applications such as data/video/voice (most flexible payload con-
cept)
♦ In the GPON TC layer, the maximum logical reach is defined as 60km
♦ ONU Activation (Discovery & Ranging)
♦ Embedded OAM messages (PLOAM)
♦ Standardized:

Page 6 of 18
Data Sheet
V5812G

- PON network diagnostic interface


- 128-bit AES for downstream encryption security
- Forward Error Correction (FEC) on Downstream/Upstream
- Fiber protection between the OLT and the splitter

GPON Features V5812G provides the following GPON features.

ONT Management over OMCI

OMCI, an ONT management and control interface protocol defined in ITU-T G.984.4, speci-
fies the format of interactive messages, and the mechanism of information exchange be-
tween an OLT and ONT. Based on the OMCI protocol, GPON terminal management en-
ables an OAM service to provide a standard way to discover ONT capabilities, and to man-
age and control them. OMCI operates on a dedicated bidirectional Port-ID between the
management station and the ONT. In addition, OMCI subdivides the ONT service module,
and defines a series of management entities used for service description.

The V5812G manages and configures various GPON terminals such as ONTs and ONUs
through the OMCI protocol. It provides MIB access that replicates the OLT information da-
tabase and connected ONTs. The management information from/to OLT and connected
ONTs flow is exchanged via an OMCI channel. Besides the OMCI, GPON provides a low
level communication channel to manage physical level issues and the GPON link layer
(GTC). The ONTs send upstream a PLOAM message with the serial number of the ONT.
Both PLOAM and OMCI channel provide full control of the optical network and the man-
agement of the customers’ ONTs.

User Data Encapsulation

GPON Encapsulation Method (GEM) is a scheme of encapsulating user frame data for
transport of the GPON network. Although any type of data can be encapsulated, actual
types depend on service situation.

The GEM protocol is used to provide delineation of the user data frames inside the GPON
partitions and the port identification for multiplexing. It can also permit fragmentation of
frames over partition boundaries.

Extended Reach GPON

Extended Reach GPON offers a clear deployment advantage that allows service providers
to dramatically increase their serving areas. V5812G GPON is especially useful for service
providers that operate in rural areas. The logical reach of the GPON is 60 km but, with the
current price point for laser transceivers, most GPON vendors limit the physical reach of
their GPON product to 20 km for a highly efficient ranging and bandwidth granting proce-
dure. The service providers can address subscribers beyond the 20 km serving-area radius
that had formerly limited the technology, without the expense of constructing and powering
remote cabinets. This is especially beneficial to service providers operating in low-density
areas.

With no additional outside plant investment, a provider can offer virtually all customers the
same high-bandwidth fiber services while minimizing the costs.

Page 7 of 18
Data Sheet
V5812G

PON Aware QoS

QoS schemes in a GPON network, ONT plays a key role in ensuring QoS for all traffic be-
cause it is the ingress/egress point for all network traffic. The ONT can have different types
of service ports, including one or more analog voice ports and one or more Ethernet ports.
It can also perform service classification based on the physical port and map it to 802.1p p-
bits. Traffic flows from voice ports, for example, can be classified as highest priority.

As part of this service differentiation, the ONT associates different traffic flows with a spe-
cific GPON Encapsulation Method (GEM) Port ID. Each physical port in a given ONT can
have a maximum of eight GEM-ports. 802.1p allows a maximum of eight classes of service
(CoS) based on p-bit marking. The GEM-Port IDs and the p-bit marking together define a
specific service.

The GPON upstream QoS provides the following advantages in specific:


♦ Bandwidth grant is out-of-band (No effect on revenue BW)
♦ SLA based on T-CONT
- No BW effect with having T-CONT per service per ONT
♦ Supports fragmented payloads (good for delay and efficiency)

2.2 Power Redundancy


The key features of V5812G are its flexibility and extremely high reliability that result from
the redundancy design concept. V5812G meets carrier’s requirements, which is a substan-
tial factor for aggregation switches to perform traffic forwarding to core network without a
failure. It provides equipment-level reliability including the power redundancy.

Power Supply Redundancy

The power feeding of the V5812G is provided by Power Supply Unit (PSU). Dual PSUs can
be installed to guarantee constant system running. If power A’s input fails, the system can
be automatically switched to the other power B’s input and normal operations of the system
are not affected.

PSUs provide the stable and proper voltages to the system with the redundant and load-
balanced power processing. A failure of the feeding line (e.g. due to an external fuse break)
does not cause system breakdown.

2.3 Non-Stop Forwarding (NSF)


The purpose of Non-Stop Forwarding (NSF) feature is to guarantee continuous forwarding
of IP packets while the routing information is being restored/refreshed in case that the con-
trol plane of a switch fails. To provide NSF feature, the system is based on a distributed ar-
chitecture, with data forwarding plane and control plane separated. The control plane han-
dles a routing protocol and the data plane is responsible for data forwarding. The data can
be properly forwarded when the control plane goes wrong.

V5812G supports NSF feature for RIP, OSPF and BGP with a graceful restart capability.

Page 8 of 18
Data Sheet
V5812G

3 Software Overview
The V5812G software also includes advanced QoS features for service provider applica-
tions with a new dynamic adaptive memory buffer technology that provides better QoS and
network performance. It also features large external address and security tables that scale
to meet the demands of high performance equipment at the core of the network.

For service providers, our software architecture facilitates a converged network by collaps-
ing voice, video and data onto a single IP backbone that supports both wired and wireless
connectivity.

3.1 Software Features


Š High Scalability & Flexibility of Full-service Solutions
Designed for maximum flexibility and scalability to ensure that carriers are able to meet
their customer’s needs with 4 GPON interfaces and 8 Gigabit Ethernet SFP or GTX
combo uplink ports. According to their network circumstances, it enables network man-
agers to build adaptable networks with maximum cost efficiency and easy manage-
ment.

Š Quick development of enhancements and bug fixes


In case V5812G needs to be updated with new software features such as GPON and
OAM, etc. or be released to new firmware due to unexpected problems, software bug
fixes can be developed and tested in a short time span. The software release allows
new features, enhancements, and problem fixes to be integrated into the software
quickly.

Š ONU Management
The V5812G provides the easy and efficient management solution for various service
environments with the ONU profile. The ONU profile is a collection of configurations for
the operation of an ONU (ONT). You can manage all ONUs connected to an OLT by
simply applying the configured profile to ONUs without any local configuration. This will
prevent unnecessary resources to configure every single ONU (ONT), allowing the
maintenance efficiency to dramatically increase.

Š Advanced Security
V5812G supports a comprehensive set of security features for connectivity and access
control, including RADIUS (Remote Authentication Dial-In User Service), TACACS+
(Terminal Access Control System), IEEE 802.1x and others. It also supports SSH (Se-
cure Shell) protocol for secure remote network management.

Page 9 of 18
Data Sheet
V5812G

3.2 Software Architecture


The V5812G is a 19” rack mountable 1U single-board type GPON OLT. The base unit pro-
vides 4 ports of GPON and 8 ports of combo type for uplink Gigabit Ethernet interface. The
system architecture is formed by the switching chip, which offers high performance. The
switching chip is connected to CPU via a PCI bus and it is also connected to GPON OLT
controller device. The host system includes the maximum 512MB SDRAM, 40MB flash
memory for CPU and 16MB flash memory for GPON OLT controller.

SFP /
CopperSFP
#1 / Dual Giga
(Combo)
Copper #2 1G X 2 PHY 1G X 2 (SGMII)
(Combo) POWER
Clock
Block
Block

SFP /
CopperSFP
#3 / Dual Giga
(Combo) 1G X 2 PHY 1G X 2 (SGMII)
Copper #4
(Combo) SDRAM

SFP /
CopperSFP
#5 / Dual Giga Flash
(Combo) 1G X 2 PHY 1G X 2 (SGMII) (8MByte)
Copper #6
(Combo)

Flash
SFP / (32MByte)
PCI BUS
CopperSFP
(Combo)
#7 / Dual Giga Switch Fabric Host Processor
1G X 2 1G X 2 (SGMII)
Copper #8
(Combo)
PHY (8GbE / 2.5 x 4Gb) MGMT
Simgle PHY

Console
DDR2 #1 RS-232
DDR2 #2
(128MB) DDR2 #3
(128MB) DDR2 #4
(128MB)
(128MB)

2.5G Down
GPON
SFP #1 1.25G Up 2.5G(HI-SGMII) Local Bus

GPON
SFP #2 2.5G(Hi-SGMII)
GPON OLT
GPON
SFP #3 2.5G(Hi-SGMII) CPLD

GPON
2.5G(Hi-SGMII)
SFP #4
OUT-BAND

FLASH
(16MB)

Figure 5 V5812G Software Architecture

The V5812G contains main on-board system components for processing and controlling
traffic that comes in from Ethernet/GPON interfaces. The system consists of the following
main boards:
• Switching board
• Controller board
• GPON OLT Controller board

Switching Board

The switching board provides the switching fabric, the system internal data interfaces to the
interface units within the switch, and also some control logics. All internal data interfaces
are based on SGMII/Hi-SGMII. The distribution of Ethernet frames between each interface
unit is provided by a Layer 3 switch.

The contains the following components:


• Layer 3 switch
• 1 Gbps SGMII & 2.5 Gbps Hi-SGMII interfaces

Page 10 of 18
Data Sheet
V5812G

The SGMII/Hi-SGMII is the system internal data interface to uplink or GPON interfaces.
The board implements the internal star topology as a set of point-to-point links between
the board and each interfaces using these internal interfaces
• Glue PLD which provides the system interface, interrupt processing, LED control, I2C
support, processor bus adaptation, reset control and GPIO for hardware control
• A serial EEPROM for storing the information for system boot
• Integrated MIPS Processor for complete system management
• NVRAM and flash memory
• 1 x FE communication interface for management access
• 1 x RS232 interface for console access

Controller Board

The controller board provides the internal communication to all interfaces. The system in-
ternal communication is implemented as inband communication over the internal FE inter-
face.

The controller core consists of the following components:


• Clock block
• I2C control
• Real time clock (RTC) circuit
• Power supply block
• CPLD for configuration, LED, sensor control logic

The controller board performs the following functions:


• Internal communication to all interfaces over the internal FE interface
• Central controller functions
• Central HW maintenance (including reset generation)
• Connection handling for the V5812G system
• Reset generation
• Collection of performance monitoring data

GPON OLT Controller Board

The OLT controller unit consists of integrated GPON devices (DBA engine, embedded CPU,
DDR controller, etc). This unit manages overall GPON process and enables the down-
stream and upstream GPON link to be fully utilized with packet and TDM data over GPON
Encapsulation Mode (GEM).

The GPON OLT controller provides the following main features:


• GPON OLT G.984.3 MACs
- Ethernet over GEM
- TDM up to 155 Mbps over GEM
- Upstream FEC
- Downstream FEC and AES
- Dynamic Bandwidth Allocation (DBA) engine for fairness algorithm bandwidth alloca-
tion per T-CONT
- Constant Bandwidth Allocation (CBA) engine for static T-CONTs bandwidth assign-
ments
- 1024 Alloc_IDs per PON
- 4096 Port_IDs per PON
• Embedded SerDes and BCDR

Page 11 of 18
Data Sheet
V5812G

• Flexible Ethernet/GPON interworking


• Seamless 2.5 Gbps network interfaces
• Seamless SFP optical transceiver interface
• PON-aware QoS feature
- Priority queues
- Priority discard and flow control

The GPON OLT controller consists of the following interfaces:

• Optical Interface
- Internal BCDR and SerDes
- Transceiver diagnostics and management
• Packet Interfaces
- Gigabit Ethernet: 4 x 2.5 Gbps SGMII
• GEM Interface
- 155 Mbps clear channel TDM
• Memory Interface
- Embedded 200MHz DDR2 controller
- Glueless interface to standard DDR2

Page 12 of 18
Data Sheet
V5812G

4 Product Specification

4.1 System
The V5812G supports the following system features:

• 36 Gbps switching capacity and 26.8 Mpps throughput


• 4-port GPON subscriber interface:
– 4-port of GPON interfaces
• 8-port GE uplink interface (Combo):
– 100/1000Base-X optical interfaces (SFP) or
– 10/100/1000Base-T electrical interfaces (RJ45)
• 1 console interface for management access
• 1 FE interface for outband management
• Redundant and load balanced plug-in Power Supply Unit (PSU)

4.2 Functionalities
The V5812G provides the following functionalities:

GPON

• Support 4K port-ID
• Support 1K alloc-ID
• Support ITU-T G.984.4 ONT Management & Control Interface (OMCI)
• Remote ONT/ONU management
• Support ONU (ONT) firmware remote upgrade
• Automatic ONT ranging
• 2.488Gbps downstream and 1.244Gbps upstream applications
• Transmission distance: 20Km with single-mode fiber

Layer 2

• Standard Ethernet Bridging


• 16K MAC entries
• 4K active VLANs for 802.1q tagged frame
• Port/Subnet/Protocol-based VLAN
• VLAN stacking/translation
• Spanning tree (STP, RSTP, MSTP, RPVST)
• Link aggregation according to 802.3ad based on MAC or IP address
• Jumbo frame 9K

Layer 3

• 4K LPM entries for IPv4/IPv6


• Static routing
• RIPv1/v2
• OSPFv2
• BGPv4
• Virtual Router Redundancy Protocol (VRRP)

Page 13 of 18
Data Sheet
V5812G

Multicast

• IGMPv1/v2/v3
• 1K L2 multicast groups
• IGMP snooping
• IGMP proxy
• IGMP static join
• Multicast VLAN Registration (MVR)
• PIM-SM, SSM

QoS

• Traffic scheduling (SP, WRR, DRR)


• 8 queues support per port
• Port rate limit with the ingress/egress shaping
• Conditional rate limiting
• Queue mapping according to ingress/egress port, MAC, 802.1q, 802.1p, ToS/DSCP,
IP SA/DA, TCP/UDP
• Access control lists based on port, MAC address, Ether type, IP SA/DA, IP multicast
address, TCP/UDP

Security

• 802.1x MAC/port based authentication


• Storm control for broadcast, multicast and unknown unicast packets
• DoS protection
• Outband management
• IP source guard
• Secure Shell (SSH)

Management

• Serial/Telnet (CLI)
• SNMPv1/v2/v3
• DHCP server, client, relay with option 82
• Single IP management
• RMON
• Syslog
• Link layer discovery protocol (LLDP)
• ARP Anti Spoofing
• Attack Guard

Page 14 of 18
Data Sheet
V5812G

4.3 Physical Specification

Mechanics

Dimensions (W x D x H) 432 mm x 300 mm x 43 mm

Weight 3.9 kg (without power module)

Minimum free space above switch 50 mm


Minimum free space below switch 25 mm
Frequency 50/60Hz
Operating Temperature -20°C ~ 60°C
Storage Temperature -40°C ~ 70°C
Operating Humidity Range 0% to 90% Non-condensing
Heat transfer
Air inlet − on the right side of the switch
Air outlet − on the left side of the switch

Power Supply

DC power voltage -48 VDC


AC power voltage 100-240 VAC, 50/60Hz
Maximum power consumption 50W

Operating Indicators

System LEDs RUN / DIAG / PWR A / PWR B


PON i/f LEDs L/A
Uplink GE i/f LEDs L/A, 1G
Console RX / TX
MGMT LNK / ACT

Interface Parameter

PON i/f 4 x GPON (SFP)


Gigabit Ethernet i/f 8 x 10/100/1000Base-T or 100/1000Base-X
(Combo uplink ports)

Ethernet i/f for local management 10/100Base-TX (RJ45)


Serial i/f, Console RS232

Page 15 of 18
Data Sheet
V5812G

4.4 GPON Optical Transceiver


The following are the features of GPON OLT Transceiver
„ GPON OLT Optical Transceiver SFP module

„ ITU-T G.984.2 Class B+ compliant

„ 1310nm Burst-mode APD/TIA receiver and 1490nm Continuous DFB laser Transmitter (with

WDM)

„ Single SC receptacle optical interface compliant

„ Hot-pluggable

„ Integrated Single fiber bi-directional optical subassembly

„ Single +3.3V power supply

„ Low power consumption

„ Class 1 Laser eye safety standard

Optical Rx Saturation Optical Application


Package Wavelength Data Rate Reach
Connector sensitivity Optical power Tx Power code
1310 nm (TX) 1.25Gb/s US GPON OLT
SC/PC SFP < -28dBm > -8dBm +1.5 ~ +5dBm 20 km
1490 nm (RX) 2.5Gb/s DS CLASS B+

Table 6 Specification of GPON OLT transceiver

4.5 Power Supply


The power supplied to the switch is regulated first through the PSU. For redundant power
supply, the second PSU has to be used. The V5812G provides a modular type of dual
power supply. It could be either AC or DC type power supply unit (PSU) for your installation
environment.

Table 7 lists the electrical characteristics of the V5812G.

Characteristic Value

Nominal DC power voltage -48Vdc


Nominal AC power voltage 100 to 240VAC 50/60 Hz
Maximum power consumption 50 W

Table 7 V5812G Electrical Characteristics

Figure 6 shows the front view of the PSUs.

Page 16 of 18
Data Sheet
V5812G

Figure 6 Front View of PSUs (AC and DC Type)

Dimensions (W x H x D) 176.8 mm x 38 mm x 115 mm


Weight (PSU-DC) 0.545 Kg
Weight (PSU-AC) 0.6 Kg

PSU-DC

DC input voltage -48/60V


Input current max. 6.25 A

Output voltage -48VDC

PSU-AC

AC input voltage 100-240VAC, 50/60Hz


Input current max. 4.75 A

Output voltage -48VDC

Page 17 of 18
Data Sheet
V5812G

5 Ordering Information
Bases
V5812G
4 Blank GPON SFP slot, 8 Port Combo GbE, 2 Blank Power Supply Module Slot, 40MB Flash, and 512MB
DRAM

Power Options

PWR-6424F0-AC
PWR-6424F1-DC
PSU_blank panel

SFP Options
SFP-GPON-OLT20
SFP GE-SX
SFP GE-LX10
SFP GE-LX20
SFP GE-LX40

Page 18 of 18