Professional Documents
Culture Documents
V5812G
1 Product Overview
V5812G is a compact GPON Optical Line Terminal (OLT) with a height of only 1U. This sys-
tem is suitable for access lines used for Ethernet leased line services.
The GPON technology adds new features and functionality targeted at improving perform-
ance and interoperability, and adds support for new applications, services, and deployment
scenarios. Among these changes are improvements in data rate and reach performance,
diagnostics, and stand-by mode, to name a few.
The V5812G introduces a point-to-multipoint concept with the GPON technology, which en-
ables a cost-effective FTTx service. The reason why GPON is considered as a cost-
effective solution is its usage of a passive splitter rather than an active switching system.
The V5812G provides four GPON ports on the front panel, each delivering 2.488Gbps
downstream and 1.244Gbps upstream. Each GPON port supports a pluggable SFP laser
module that allows selection of the best speed and power to meet network requirements. It
is comprised of 8 electrical and optical combo GE interfaces as uplink towards the core
network and these interfaces can be used either to cascade other switches or to connect to
a collocated DSLAM. The MGMT and console interface is located on the most left of the
front panel with embedded LED for LNK/ACT and TX/RX indication respectively. They are
for use of equipment management via remote access or CLI.
MGMT Interface
(10/100Base-TX) 4 x GPON Interfaces
Operating LED Indicator for system operating status including power, fault detection -
and booting state.
CONSOLE CLI access to configure the functions for system operation RJ45 (RS232)
MGMT Outband TMN-OS Interface RJ45
Subscriber i/f 4 x GPON ports SFP
Uplink i/f 8 x 100/1000Base-X or 10/100/1000Base-T combo type ports SFP or RJ45
Page 2 of 18
Data Sheet
V5812G
The V5812G has two Power Supply Unit (PSU) mounting slots on the rear panel. Each
PSU is comprised of single DC or AC power input. For power redundancy, user can equip
dual PSUs into 2-slot. Install an appropriate PSU between AC type and DC type according
to your installation environment.
For GPON, the PON layer is terminated on the interface unit and translated to Ethernet up-
link to be transported through an Ethernet/IP environment. For improved system reliability, it
adopts the design of redundancy architecture with dual power supplies.
The power feeding of the V5812G is provided by Power Supply Unit (PSU). Dual PSUs can
be installed to guarantee constant system running. If power A’s input fails, the system can
be automatically switched to the other power B’s input and normal operations of the system
are not affected.
Page 3 of 18
Data Sheet
V5812G
Core Network
Splitter
Shared OLT
User Fiber
ONTs
(ONUs)
The V5812G is a network element, which includes the necessary service adaptation func-
tions to support the delivery of all types multiple services, such as Ethernet, IP telephony,
and video services.
The V5812G GPON OLT system is one element of this end-to-end solution, however
Dasan Networks is able to provide the complete next generation broadband access net-
work and video integration solution, where full interoperability is ensured. Up to 64 termina-
tion points for GPON can be attached to an OLT via passive optical splitter.
There are different possible deployment topologies for GPON networks, which differentiate
from each other basically from the place the optical fiber is terminated. Depending on the
subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber
to the Home), FTTB (fiber to the Building), FTTN (fiber to the neighborhood) or FTTC (fiber
to the Curb). In case of very high bandwidth requirement per user, scenarios without split-
ters offering 2.5Gbps/1.25Gbps (downstream/upstream) data rate can also be deployed by
connecting only the single user on a GPON port.
Street Curb or
Cabinet
HDTV
Central Office
VoIP
Shelf-based
DSLAM
PC
VoIP
IP DSLAM OLT
ONU PC
Server FTTH
VoIP
L2 Switch/
PC
ONU
FTTB
Page 4 of 18
Data Sheet
V5812G
SFP-GE-SX SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX10 SFP GE LX10
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX20 SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX40 SFP GE LX40
- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
Other types of SFP module can be also available upon customer request.
i
Power Options
Name Description Maximum
quantity
Page 5 of 18
Data Sheet
V5812G
Feature Benefits
GPON system of V5812G provides the network services at no extra cost, while EPON sys-
tems require additional adaptation equipment for TDM. It also offers much more available
bandwidth for the entire range of applications. The V5812G introduces a point-to-multipoint
concept with the several GPON mechanisms, which enable the efficient and flexible FTTx
services.
Page 6 of 18
Data Sheet
V5812G
OMCI, an ONT management and control interface protocol defined in ITU-T G.984.4, speci-
fies the format of interactive messages, and the mechanism of information exchange be-
tween an OLT and ONT. Based on the OMCI protocol, GPON terminal management en-
ables an OAM service to provide a standard way to discover ONT capabilities, and to man-
age and control them. OMCI operates on a dedicated bidirectional Port-ID between the
management station and the ONT. In addition, OMCI subdivides the ONT service module,
and defines a series of management entities used for service description.
The V5812G manages and configures various GPON terminals such as ONTs and ONUs
through the OMCI protocol. It provides MIB access that replicates the OLT information da-
tabase and connected ONTs. The management information from/to OLT and connected
ONTs flow is exchanged via an OMCI channel. Besides the OMCI, GPON provides a low
level communication channel to manage physical level issues and the GPON link layer
(GTC). The ONTs send upstream a PLOAM message with the serial number of the ONT.
Both PLOAM and OMCI channel provide full control of the optical network and the man-
agement of the customers’ ONTs.
GPON Encapsulation Method (GEM) is a scheme of encapsulating user frame data for
transport of the GPON network. Although any type of data can be encapsulated, actual
types depend on service situation.
The GEM protocol is used to provide delineation of the user data frames inside the GPON
partitions and the port identification for multiplexing. It can also permit fragmentation of
frames over partition boundaries.
Extended Reach GPON offers a clear deployment advantage that allows service providers
to dramatically increase their serving areas. V5812G GPON is especially useful for service
providers that operate in rural areas. The logical reach of the GPON is 60 km but, with the
current price point for laser transceivers, most GPON vendors limit the physical reach of
their GPON product to 20 km for a highly efficient ranging and bandwidth granting proce-
dure. The service providers can address subscribers beyond the 20 km serving-area radius
that had formerly limited the technology, without the expense of constructing and powering
remote cabinets. This is especially beneficial to service providers operating in low-density
areas.
With no additional outside plant investment, a provider can offer virtually all customers the
same high-bandwidth fiber services while minimizing the costs.
Page 7 of 18
Data Sheet
V5812G
QoS schemes in a GPON network, ONT plays a key role in ensuring QoS for all traffic be-
cause it is the ingress/egress point for all network traffic. The ONT can have different types
of service ports, including one or more analog voice ports and one or more Ethernet ports.
It can also perform service classification based on the physical port and map it to 802.1p p-
bits. Traffic flows from voice ports, for example, can be classified as highest priority.
As part of this service differentiation, the ONT associates different traffic flows with a spe-
cific GPON Encapsulation Method (GEM) Port ID. Each physical port in a given ONT can
have a maximum of eight GEM-ports. 802.1p allows a maximum of eight classes of service
(CoS) based on p-bit marking. The GEM-Port IDs and the p-bit marking together define a
specific service.
The power feeding of the V5812G is provided by Power Supply Unit (PSU). Dual PSUs can
be installed to guarantee constant system running. If power A’s input fails, the system can
be automatically switched to the other power B’s input and normal operations of the system
are not affected.
PSUs provide the stable and proper voltages to the system with the redundant and load-
balanced power processing. A failure of the feeding line (e.g. due to an external fuse break)
does not cause system breakdown.
V5812G supports NSF feature for RIP, OSPF and BGP with a graceful restart capability.
Page 8 of 18
Data Sheet
V5812G
3 Software Overview
The V5812G software also includes advanced QoS features for service provider applica-
tions with a new dynamic adaptive memory buffer technology that provides better QoS and
network performance. It also features large external address and security tables that scale
to meet the demands of high performance equipment at the core of the network.
For service providers, our software architecture facilitates a converged network by collaps-
ing voice, video and data onto a single IP backbone that supports both wired and wireless
connectivity.
ONU Management
The V5812G provides the easy and efficient management solution for various service
environments with the ONU profile. The ONU profile is a collection of configurations for
the operation of an ONU (ONT). You can manage all ONUs connected to an OLT by
simply applying the configured profile to ONUs without any local configuration. This will
prevent unnecessary resources to configure every single ONU (ONT), allowing the
maintenance efficiency to dramatically increase.
Advanced Security
V5812G supports a comprehensive set of security features for connectivity and access
control, including RADIUS (Remote Authentication Dial-In User Service), TACACS+
(Terminal Access Control System), IEEE 802.1x and others. It also supports SSH (Se-
cure Shell) protocol for secure remote network management.
Page 9 of 18
Data Sheet
V5812G
SFP /
CopperSFP
#1 / Dual Giga
(Combo)
Copper #2 1G X 2 PHY 1G X 2 (SGMII)
(Combo) POWER
Clock
Block
Block
SFP /
CopperSFP
#3 / Dual Giga
(Combo) 1G X 2 PHY 1G X 2 (SGMII)
Copper #4
(Combo) SDRAM
SFP /
CopperSFP
#5 / Dual Giga Flash
(Combo) 1G X 2 PHY 1G X 2 (SGMII) (8MByte)
Copper #6
(Combo)
Flash
SFP / (32MByte)
PCI BUS
CopperSFP
(Combo)
#7 / Dual Giga Switch Fabric Host Processor
1G X 2 1G X 2 (SGMII)
Copper #8
(Combo)
PHY (8GbE / 2.5 x 4Gb) MGMT
Simgle PHY
Console
DDR2 #1 RS-232
DDR2 #2
(128MB) DDR2 #3
(128MB) DDR2 #4
(128MB)
(128MB)
2.5G Down
GPON
SFP #1 1.25G Up 2.5G(HI-SGMII) Local Bus
GPON
SFP #2 2.5G(Hi-SGMII)
GPON OLT
GPON
SFP #3 2.5G(Hi-SGMII) CPLD
GPON
2.5G(Hi-SGMII)
SFP #4
OUT-BAND
FLASH
(16MB)
The V5812G contains main on-board system components for processing and controlling
traffic that comes in from Ethernet/GPON interfaces. The system consists of the following
main boards:
• Switching board
• Controller board
• GPON OLT Controller board
Switching Board
The switching board provides the switching fabric, the system internal data interfaces to the
interface units within the switch, and also some control logics. All internal data interfaces
are based on SGMII/Hi-SGMII. The distribution of Ethernet frames between each interface
unit is provided by a Layer 3 switch.
Page 10 of 18
Data Sheet
V5812G
The SGMII/Hi-SGMII is the system internal data interface to uplink or GPON interfaces.
The board implements the internal star topology as a set of point-to-point links between
the board and each interfaces using these internal interfaces
• Glue PLD which provides the system interface, interrupt processing, LED control, I2C
support, processor bus adaptation, reset control and GPIO for hardware control
• A serial EEPROM for storing the information for system boot
• Integrated MIPS Processor for complete system management
• NVRAM and flash memory
• 1 x FE communication interface for management access
• 1 x RS232 interface for console access
Controller Board
The controller board provides the internal communication to all interfaces. The system in-
ternal communication is implemented as inband communication over the internal FE inter-
face.
The OLT controller unit consists of integrated GPON devices (DBA engine, embedded CPU,
DDR controller, etc). This unit manages overall GPON process and enables the down-
stream and upstream GPON link to be fully utilized with packet and TDM data over GPON
Encapsulation Mode (GEM).
Page 11 of 18
Data Sheet
V5812G
• Optical Interface
- Internal BCDR and SerDes
- Transceiver diagnostics and management
• Packet Interfaces
- Gigabit Ethernet: 4 x 2.5 Gbps SGMII
• GEM Interface
- 155 Mbps clear channel TDM
• Memory Interface
- Embedded 200MHz DDR2 controller
- Glueless interface to standard DDR2
Page 12 of 18
Data Sheet
V5812G
4 Product Specification
4.1 System
The V5812G supports the following system features:
4.2 Functionalities
The V5812G provides the following functionalities:
GPON
• Support 4K port-ID
• Support 1K alloc-ID
• Support ITU-T G.984.4 ONT Management & Control Interface (OMCI)
• Remote ONT/ONU management
• Support ONU (ONT) firmware remote upgrade
• Automatic ONT ranging
• 2.488Gbps downstream and 1.244Gbps upstream applications
• Transmission distance: 20Km with single-mode fiber
Layer 2
Layer 3
Page 13 of 18
Data Sheet
V5812G
Multicast
• IGMPv1/v2/v3
• 1K L2 multicast groups
• IGMP snooping
• IGMP proxy
• IGMP static join
• Multicast VLAN Registration (MVR)
• PIM-SM, SSM
QoS
Security
Management
• Serial/Telnet (CLI)
• SNMPv1/v2/v3
• DHCP server, client, relay with option 82
• Single IP management
• RMON
• Syslog
• Link layer discovery protocol (LLDP)
• ARP Anti Spoofing
• Attack Guard
Page 14 of 18
Data Sheet
V5812G
Mechanics
Power Supply
Operating Indicators
Interface Parameter
Page 15 of 18
Data Sheet
V5812G
1310nm Burst-mode APD/TIA receiver and 1490nm Continuous DFB laser Transmitter (with
WDM)
Hot-pluggable
Characteristic Value
Page 16 of 18
Data Sheet
V5812G
PSU-DC
PSU-AC
Page 17 of 18
Data Sheet
V5812G
5 Ordering Information
Bases
V5812G
4 Blank GPON SFP slot, 8 Port Combo GbE, 2 Blank Power Supply Module Slot, 40MB Flash, and 512MB
DRAM
Power Options
PWR-6424F0-AC
PWR-6424F1-DC
PSU_blank panel
SFP Options
SFP-GPON-OLT20
SFP GE-SX
SFP GE-LX10
SFP GE-LX20
SFP GE-LX40
Page 18 of 18