Design Of Isolated Footing 1 of 3

1 Footing Size Design

Load Pu 353 KN
Design Load P 259 KN

Moment in x dir Mux 46 KN-m


Moment in y dir Muy 37 KN-m

Column size cx 300 mm


cy 300 mm

SBC q 250 KN/sqm

Footing Size required A req 1.04 sqmm

L 1.50 meters
Footing Size Provided
B 1.50 meters
Area Provided A prvd 2.25 meters

Zx 0.56
Zx 0.56

Net upward pressure Nup 213 KNm2

Footing Size OK

2 Slab Design
lx 0.600
ly 0.600

Bending Moment in x dir Mx 58 KN-m


Bending Moment in y dir My 58 KN-m

Concrete fck 20 MPa


Steel fy 415 MPa

Minimum Depth Required dmin 145

Depth Provided D 500 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 444 mm

Spacing c/c in mm
Area of Steel
12# 16# 20#
533 sqmm 212 c/c 377 c/c 590 c/c
533 sqmm 212 c/c 377 c/c 590 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion

Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm


Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
Design Of Isolated Footing 2 of 3
3 One Way Shear along x direction

Vu1 75 KN
ζv 0.112 MPa

ζc 0.260 MPa
Vc1 173 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 75 KN
ζv 0.112 MPa

ζc 0.260 MPa
Vc1 173 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 543 KN
ζv 0.411 MPa

ks*ζc 1.118 MPa


Vc1 1477 KN

Two Way Shear Check OK


Design Of Isolated Footing 3 of 3
L= 1.50 meters

300

300
B= 1.50 meters

500 mm
200 mm

12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c