Elevation: 250 Meter Barometric pres: 10020 mmwg Duct diameter 2.35 Meter Area 4.3391071429 Meter² Ambient Temperture 25 °C Process Temperture 374 °C Static Pressure -483 mmwg Pitot tube Factor 0.84 static pressure at fan outlet 100 mmwg Density of gas calculation
Volume flow 236220.296150454 m^3/hr Volume flow 91994.3021462004 Nm^3/hr Mass flow 127558.959921245 kg/hr Clinker Rate 6000000 kg/hr Specific mass flow 0.0212598267 Kg/Kg Clinker Specific gas flow 0.0153323837 Nm³/Kg Clk
Fan Efficiency determination
Fan Total Pressure 583 mmwg
Compressibility coefficient 2.5 Absorbed power 1000 KW Air power 938.1931974671 KW Shaft power 970 KW Fan efficiency 96.7209481925 Voltage rating 100 Current 200 Power factor 0.85 Power 29444 Air power/0.80 1172.7414968338 KW Power saving -202.7414968338 KW FAN FLOW MEASUREMENT P SHAFT Pabs -(Fixed losses + Copper losses + Stray load loss @ 3% of motor absorbed power) OW MEASUREMENT