You are on page 1of 4

PRODUCT DATA SHEET

SikaProof® A+ 12
PRE-APPLIED FULLY BONDED FPO SHEET MEMBRANE WATERPROOFING SYSTEM

DESCRIPTION CHARACTERISTICS / ADVANTAGES


SikaProof® A+ 12 sheets are fully bonded, composite ▪ Pre-applied, before the reinforcement is fixed and the
sheet membrane waterproofing system for reinforced concrete is cast
concrete structures. It consists of a polyolefin (FPO) ▪ Fully and permanently bonded to the reinforced con-
based membrane containing a cementitious hybrid crete structure
layer, which forms a permanent, mechanical and adhe- ▪ Mechanical and adhesive bond formation with fresh
sive bond with fresh concrete. SikaProof® A+ 12 is cold concrete
and pre-applied, as it is installed without heat or open- ▪ No lateral water migration between the concrete
flames, and is fixed prior to steel reinforcement and cast- structure and the membrane system
ing of concrete. ▪ High watertightness tested according to various
standards
USES ▪ Easy to install with fully adhered joints
SikaProof® A+ 12 may only be used by experienced profes-▪ Cold-applied (no pre-heating or open-flames)
sionals. ▪ Temporarily resistant to weathering and UV-light dur-
Damp proofing, waterproofing and concrete protection ing construction
against ground water ingress for basements and other ▪ Resistant to aging
below ground concrete structures. Suitable for the use ▪ High flexibility and crack-bridging capabilities
on: ▪ Resistant to aggressive conditions in natural ground
▪ Below ground reinforced concrete slabs water and soil
▪ On reinforced concrete walls with both single and double- ▪ Can be combined with other approved Sika® Water-
faced formwork proofing / Joint Sealing Systems
▪ Extensions and reconstruction works
▪ Prefabricated structures

PRODUCT INFORMATION
Composition Membrane Layer Flexible Polyolefin (FPO)
Hybrid Layer: Polymer modified cement
Packaging Roll width 1,00 m or 2,00 m
Roll length 20 m
Appearance / Colour Light yellow sheet membrane containing a grey bonding layer
Shelf life 18 months shelf life from date of production if stored properly in undam-
aged, unopened, original sealed packaging. (Expiration date: see label)

PROVISIONAL PRODUCT DATA SHEET


SikaProof® A+ 12
January 2019, Version 01.0
020704210210000022

1/4
Storage conditions Dry storage at temperatures from +5°C up to 30°C. Protect from direct sun-
light, rain, snow, ice, humidity, etc. Store in a horizontal position. Do not
stack pallets of the membrane rolls on top of each other or under pallets of
any other materials during transport or storage.
Effective Thickness (EN 1849-2)
Total Thickness (=deff) 1.75 mm (-5/+10 %)
Membrane Layer Thickness 1,20 mm

Mass per unit area 1,75 kg/m2 (-5/+10 %) (EN 1849-2)

TECHNICAL INFORMATION
Resistance to Impact ≥ 400 mm (EN 12691)

Tensile Strength (EN 12311-2


(Based on membrane layer only) Method B)

Modulus of Elasticity in Tension ≤ 35 N/mm2 (-/+10 %) (EN ISO 527-3)

Elongation (EN 12311-2


Machine direction ≥ 600 % Method B)

Cross direction: ≥ 600 %

Adhesion in Peel After 28 days = 3.26 N/mm (EN 1372)

Joint Shear Resistance ≥ 100 N/50 mm (EN 12317-2)


Low Temperature Flexibility Unaffected at -29 oC (ASTM D1970)
Crack Cycling @ -23 oC Pass, no crack (ASTM 1305)
Puncture Resistance 226 lbs (No Puncture) (ASTM E154)

Lap Peel Adhesion 51 pounds-inch (ASTM D1876)


Water Vapor Transmission 0.26 perms (ASTM E96)

Reaction to Fire Class E (EN 13501-1)


Accelerated Ageing in Alkaline Environ- Pass (28 d/+23°C) (EN1847)

ment Pass (Method B, 24 h/60 kPa) (EN1928)

Watertightness Pass(Method B, 24 h/60 kPa) (EN 1928)

Resistance to lateral water migration Pass, up to 7 bar (ASTM D5385 Modified)

Durability of Watertightness against Pass (12 weeks) (EN 1847)


Ageing Pass (Method B, 24 h/60 kPa) (EN 192

Durability of Watertightness against Pass (28 d/+23 °C) (EN 1847)


Chemicals Pass (Method B, 24 h) (EN 1928)

Service Temperature -10 °C min. / +35 °C max.

PROVISIONAL PRODUCT DATA SHEET


SikaProof® A+ 12
January 2019, Version 01.0
020704210210000022

2/4
SYSTEMS

System Structure System Components


▪ SikaProof® A+ 12 sheet membranes
▪ SikaProof® Tape A+: self-adhesive tape for internal jointing
▪ SikaProof® Sandwich Tape: double-sided tape for internal jointing Acces-
sories: Accessories and complementary products are additionally available
to create the relevant details and connections, see current Method State-
ment of SikaProof® A+ systems.

APPLICATION INFORMATION

Ambient Air Temperature +5 °C min. / +45 °C max

Substrate Temperature +5 °C min. / +60 °C max

APPLICATION INSTRUCTIONS
SUBSTRATE QUALITY ▪ After removing the formwork all penetrations, such
SikaProof® A+ membrane must be applied on a suffi- as shuttering anchors, any membrane damage and
ciently stable substrate to avoid movement during the any construction joints have to be sealed using
construction work. A smooth, uniform and clean sub- ▪ the appropriate SikaProof® A+ accessories or com-
strate surface is essential to prevent damage to the plementary Sika Waterproofing Systems.
membrane. Large gaps and voids (> 12–15 mm) must ▪ After removing the formwork the membrane system
be closed prior to the installation of the SikaProof® A+ (membrane side) has to be protected as soon as pos-
membrane system. The substrate can be damp or sible before backfilling or at the latest 90 days after
slightly wet, but ponding water must be avoided. Suit- installation
able substrates to fix the SikaProof® A+ membrane ▪ For more detailed information about installation
system onto include: ▪ Concrete blinding please refer to the current SikaProof® A+ Method
▪ Formwork Statement and Application Manual. For more guid-
▪ Rigid thermal insulation ance please contact the Sika Technical Service.
▪ Plywood sheets / forms
APPLICATION METHOD / TOOLS IMPORTANT CONSIDERATIONS
▪ SikaProof® A+ membranes must only be installed by
SikaProof® A+ 12 is a pre-applied waterproofing mem- Sika trained and approved applicators.
brane system, installed prior to fixing the reinforce- ▪ The SikaProof® A+ Method Statement, with its tech-
ment and casting of structural concrete. nical guidelines and information, must be complied
General Installation Procedure: with.
▪ Ensure the substrate fulfils the necessary require- ▪ Do not install SikaProof® A+ membranes during con-
ments. tinuous or prolonged rain- or snowfall.
▪ Lay out the SikaProof® A+ membrane sheets on the ▪ The substrate, where the membrane is applied, must
horizontal or vertical area using 1,0 m or 2,0 m width be clean and not more than damp.
rolls. ▪ The surface to be bonded (overlaps, connections
▪ All joints and details will be bonded and sealed using etc.) must be clean, dry and minimum temperature
the SikaProof® Tape A+ and/or SikaProof® Sandwich above +5 °C. (If below, appropriate measures must
Tape be taken.)
▪ Form all details and connections according to the ▪ Additional Sika® Joint Sealing Solutions (minimum Si-
Method Statement using the appropriate SikaP- kaSwell®) must be used for connection, around pen-
roof® accessories. etrations and in constructions and expansion joints.
▪ Especially for sealing construction and expansion ▪ The structural concrete must be placed within 90
joints use additional Sika® Joint Solutions. days after the SikaProof® A+ membrane system is in-
▪ A final inspection before casting of concrete is man- stalled.
datory to ensure that the membrane system is cor- ▪ An adequate concrete quality (mix design and work-
rectly applied and clean. Refer to the Method State- manship) is required to achieve optimal full-surface
ment to see the appropriate measures. bond formation between the SikaProof® A+ mem-
▪ The concrete has to be poured within 90 days after brane system and the structural concrete.
installation, directly onto SikaProof® A+ system. ▪ The SikaProof® A+ membrane are not permanently
UV and weather resistant. Therefore the membrane
PROVISIONAL PRODUCT DATA SHEET
SikaProof® A+ 12
January 2019, Version 01.0
020704210210000022

3/4
system must not be installed on structures perma- LEGAL NOTES
nently exposed to UV light and weathering.
The information, and, in particular, the recommenda-
▪ After removing the formwork the membrane system
tions relating to the application and end-use of Sika
(membrane side) has to be protected as soon as pos-
products, are given in good faith based on Sika's cur-
sible before backfilling or at the latest 90 days after
rent knowledge and experience of the products when
installation.
properly stored, handled and applied under normal
For more detailed information and guidance please conditions in accordance with Sika's recommenda-
refer to the current Method Statement for the SikaP- tions. In practice, the differences in materials, sub-
roof® A+ membrane system. strates and actual site conditions are such that no
Recommended Standard Use: warranty in respect of merchantability or of fitness for
Sika recommends to use the SikaProof® A+ mem- a particular purpose, nor any liability arising out of any
brane system for damp proofing and waterproofing of legal relationship whatsoever, can be inferred ei- ther
below ground constructions up to a certain demand. from this information, or from any written rec-
Refer to section "Project Design" of the SikaProof® A+ ommendations, or from any other advice offered. The
Method Statement for selecting the most suitable user of the product must test the product’s suitability
type of SikaProof® A+ membrane. Contact Sika Tech- for the intended application and purpose. Sika re-
nical Service for additional information and assistance serves the right to change the properties of its prod-
on the selection and specification of the appropriate ucts. The proprietary rights of third parties must be
solution for the specific project. observed. All orders are accepted subject to our cur-
rent terms of sale and delivery. Users must always re-
BASIS OF PRODUCT DATA fer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
All technical data stated in this Data Sheet are based be supplied on request.
on laboratory tests. Actual measured data may vary
due to circumstances beyond our control.

LOCAL RESTRICTIONS
Note that as a result of specific local regulations the
declared data and recommended uses for this prod-
uct may vary from country to country. Consult the lo-
cal Product Data Sheet for the exact product data and
uses.

ECOLOGY, HEALTH AND SAFETY


REGULATION (EC) NO 1907/2006 – REACH

Sika Services AG
Tüffenwies 16
8048 Zürich Tel: +41 58 436 4040
www.sika.com

PROVISIONAL PRODUCT DATA SHEET


SikaProof® A+ 12
January 2019, Version 01.0
020704210210000022

4/4

You might also like