You are on page 1of 4
Stocklist Checklist 1. Drawing(s) and Hydraulic Caleulations should be checked by Design Manager before stock-listing any materials 2. Start with flange located at the base of the riser. 3. List all mains frst following the flow of water through the system. Pick up couplings, fittings & valves as you run into them. 4. When listing valves pick up all trims and accessories that go along with that valve. Look in the Technical Data book and it will list all items required for that valve along with the part number. 5. Check the list below for all items required. Order systems complete one time. NO PARTIAL SYSTEM ERS. 6. Completing the order includes Packet. 7. Order all items per supplier or vender. 8. VERIFY ALL PIPE AND FITTING TYPES SPECIFIED FOR THIS PROJECT and pat this-information on the stocklist and plans 9. Verify all ordered material with approved product data. Do NOT deviate from what was approved. materials ordered and making of the Forman’s Underground (Requisitioned List): J. Elbows, Tees & Uniflange with accessories as required ____ Sectional Valves as required (Check depth of bury) __ Hydrants if required. ___ Ductile Iron pipe 5’-0" out past building to spigot on riser. ___ Roadway Box or Post Indicator for all underground N.R.S gate valves. ___ Bent Eye Bolts (2 per fitting & 2 per dead man) __ Uniflange ___ Two (2) Alll Thread Rod %” x 10’-0” per fitting (6” & 8” underground) __ Two (2) All Thread Rod 5/8” x 10°-0” per fitting (4” underground) Nuts & Washers Risers and System Components: Control Valve - Couplings for grooved and bolt packs, grooved flanges and/or tamper switches for OS&Y valves, (Wall post indicator when required) __ Alarm Valve Vertical open trim Pressure switch(s) (if required) Retard Chamber & trim Misc. 2” & 1-1/4” pipe for drain lines and fittings Water Motor alarm or Electric Bell Misc %” & 1” galvanized pipe for WMA. Addition check valves & strainer when more than one system is on a single WMA. ae ae Flowswitch ‘Tamper Switch Fire Department Connection 1. Check Valve Ball Drip Valve All Caps, Chains, Wall Plates, etc. (Double check finishes) Misc. Pipe & Fittings for drains out of the wall. 1. (1) 2” Black C.l. Elbow (per riser) 2. (1) 2” Galvanized 45 degree elbow 3. (1) 2” Galvanized wall plate 4. (1) 1-1/4" Black C.L. Elbow (per riser) 5. (1) 1-1/4” Galvanized 45 degree elbow 6. (1) 1-1/4” Galvanized wall plate 7. (1) 2” Random Black Schedule 40 Pipe 8. (1) 1-1/4" Random Black Schedule 40 Pipe 9. (1) 2” Black C.l. Tee for each additional riser 10. (1) 2” Union for each additional riser Dry Pipe Valves and/or Preaction Valves 1. %" outlet on supply side of control valve for priming line 2. All Trims - Look at data sheet for which one is required for specific type of system you are designing Pressure Alarm Switch High/Low Pressure Switch Air Maintenance Device Air Compressor (Sized for capacity of the dry system). See plan. Pipe & Fittings from compressor to Valve a. (6) 4” Galvanized M.L. Elbows b. (1) 4” Random Galvanized Pipe Noy ay ____ Deluge Valves 1. 14" outlet on supply side of control valve for priming line 2. All Trims - Look at data sheet for which one is required for specific type of system you are designing 3. 14" clamps for pilot lines 4, Pilot line pipe, fittings & heads ___ Fire Pumps 1. All pipe on suction side of Fire Pump (and Jockey Pump) to be galvanized. Alll Valves (Including those located in the Jockey Pump piping) Outlets on pipe for jockey pump supply & discharge. ‘Tamper switches. Test Header pipe, valve & materials. 24” Check Valves w/ 3/32” hole in clapper for sensing lines ‘A” Globe Valves for sensing lines 44” Brass Tubing (50”) ‘4” Brass Tees and Elbows 0.4" Plugs 1, Jockey Pump Piping and Fittings See aH EEN __ Inspector's Test 1. 1” Galvanized 45 degree elbow 2. 1” Galvanized wall plate 3. 1" Globe Valve or TestandDrain. (Pressure Relief for Gridded Systems) 4, 4" or 4” Test Connection (when not using TestanDrain). Size to match smallest orifice of head in the system. Sprinkler Heads (Verify type, size, temperature, K-factor and finish) Sprinkler Wrench (1 for every type of head used) Spare Head Cabinet (6 or 12) Random Length of pipe for each size of pipe used (1” thru 2” only) along with some additional fittings for each size of pipe use. __Signs Main Drain Control Valve Inspectors Test Aux. Drain Bee ___ Hangers 1, Order all materials, ATR, Rings, TBC’s Sammy's, Drop-In Anchors, Etc. (Verify type of materials required by spec.) 2. Order all trapeze materials (Pipe, Rings, TBC, etc.) Gauges 1. Order nipples and valve along with gauge. ___ Sleeves 1. Verify what walls require sleeves and the material specified for the sleeves. Order all sleeves required for the project along with sleeve information placed on the drawing.

You might also like