SL-100 ELECTRIC BOLT ACTION LOCK

INSTALLATION MANUAL

•POWER SUPPLY:DC12V 1A.


•OPERATION CURRENT 900mA, HOLDING CURRENT 360mA .
•FAIL-SAFE TYPE (POWER LOCK)
• DOOR SENSOR:N.C.(SL-100A),N.C. & N.O.(SL-100B)
• OPERATION DELAY TIME:0 SEC. 2.5SEC. 5SEC. 9SEC.
• BUILT-IN DELAYED EGRESS CONTROL POINT
• FACE PLATE:200mm(L)x32mm(W)x40mm(D)
• STRIKE PLATE:90mm(L)x26mm(W)x2mm(D)

SL-100A (5 PIN ) SL-100B (6PIN )


BROWN : GND BROWN : GND
RED : + DC12V RED : + DC12V
ORANGE : PUSH BUTTON ORANGE : PUSH BUTTON
YELLOW : DOOR POSITION SENSOR(N.C.) YELLOW : DOOR POSITION SENSOR(N.C.)
GREEN : DOOR POSITION SENSOR(COM.) GREEN : DOOR POSITION SENSOR(COM.)
BLUE : DOOR POSITION SENSOR(N.O.)

READER

PUSH BUTTON
N.C. COM
N.O.

SL-100
+DC12V

ORANGE
BROWN
AP-10
RED DC 12V
1A

0 SEC. 5 SEC.
Setting door lock delay timer :
2.5 SEC. 9 SEC.

※ Please switch on the appliance again to validate any adjustment of DIP

Page 1
Accessories:

X 1 Lock body
X 1 Strike plate

X 2 Shims(small)
X 2 Shims (Large) for
For strike plate
Lock body
SCREWS:
X 8 Small wood screws for strike
plate( 4 x 8 mm) 5-PIN Connector
X 4 Large metal screws for lock
body and shims( 5 x 8 mm)
X4 Small metal screws for strike plate
and shims( 4 x 26 mm)
X 2 Large wood screws for lock Lock body
body( 5 x 15 mm) templates
Strike plate template

Faceplate

Current and Temperature Chart:


Time (sec.)

900
800 Start
700 Stand-by
Current600
500
(mA) 400 Door Close
300 Delay Time
~
~

200 Setting
100
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Time (sec.)

70
65
60
55
Temperature
(℃) 50
45
40
35
30
~
~

25
0 10 20 30 40 50 60 70 80 90 100110120130140150 Time (min.)
Supply power & door close

Page 2
Installation:

Instruction:
Diagram 1: Dimensions
Diagram 2: For double door mounting
Diagram 3: For single door mounting
Diagram 4: For vertical mounting
Important-For vertical
mounting, wires must come
out the top of the unit.

Diagram 1

Diagram 2 Diagram 3 Diagram 4

For double doors For single doors For single doors

Page 3
Installation:
For hollow metal doors: For wood doors:
Please make sure the correct
direction of the shims when mounted

45mm

20mm

Faceplate Question & Answer


◆ The lock is hot ?
The operating temperature of the lock is normally within 55℃ .
◆ No operation after installation?
Strike plate 1.Please check power supply. 2.Please check if the direction of
Drill hole for magnet the template is being installed correctlly 3.Please check the
connection points(N.O or N.C)
(if wood door) ◆ Lock will open when force is applied on the reader (eg. Hitting
Door Drill hole for deadbolt hard or vibrating the reader). ?
(If wood door) 1.Please check all the connections .
2.Reader's N.C points might strike immediately when force is
being applied on it this eventually causes the fail-safe type of lock
to open when sudden power cut occured. Please refer to page 1
for wiring to prevent such case happen.