The document contains 30 multiple choice questions about SSDAC systems. SSDAC systems use axle counters and track circuits to monitor train movement and detect the passing of wheels and axles. They employ technologies like frequency detection, cable communication, and voltage regulation to function properly. The questions cover topics like the components, specifications, operating parameters, and troubleshooting of SSDAC systems.
The document contains 30 multiple choice questions about SSDAC systems. SSDAC systems use axle counters and track circuits to monitor train movement and detect the passing of wheels and axles. They employ technologies like frequency detection, cable communication, and voltage regulation to function properly. The questions cover topics like the components, specifications, operating parameters, and troubleshooting of SSDAC systems.
The document contains 30 multiple choice questions about SSDAC systems. SSDAC systems use axle counters and track circuits to monitor train movement and detect the passing of wheels and axles. They employ technologies like frequency detection, cable communication, and voltage regulation to function properly. The questions cover topics like the components, specifications, operating parameters, and troubleshooting of SSDAC systems.
1. Axle counters & track circuits are treated as authorized ____
a) Means of communication b) Means of knowledge c) Means of transportation d) None 2. What are the frequencies used in HASSDSC of GG Tronics make? a. 15 KHz & 17 KHz b. 21 KHz & 25 KHz c. 21 Hz & 25 Hz d. 23 KHz & 25 KHz 3. What is the resistance of vital relay of digital axle counter? a. 1000 Ohms b. 9 Ohms c. 50 Ohms d. 100 Ohms 4. TX coil is always connected _________ the rail. a. Outside b. Inside c. Both sides d. Between 5. The distance from home signal to the block section shall not be less than _______ Mtrs. a. 180 b. 120 c. 400 d. 580 6. What is the maximum current drain by DC –DC converter of GG Tronics make? a. 300 mA b. 1200 mA c. 200 mA d. 500 mA 7. SSDAC communication using V.23 FSK modem with cable loss of _______________ dB. a. 20 b. 30 c. 40 d. 50 8. Basic principle employees n SSDAC is ________________ a. Amplitude detection b. Frequency detection c. Phase detection d. Voltage detection 9. The minimum train wheel diameter, Which the system senses____________ a. 500mm b. 490mm c. 520mm d. 550mm 10. The design of track device is suitable for _____________rails. a. 50Kg & 62Kg b. 42Kg & 64Kg c. 52Kg & 60Kg d. 50Kg & 60Kg 11. The indoor equipment consists of ______________ a. Evaluator System b. SM Reset box c. Relay Rack d. All of the above 12. The input voltage of DC – DC converter is ______________ a. 24V b. 12V c. 18V d. 5V 13. In system evaluator MS Coupler no. 5 is used for ____________cable. a. PD card b. Relay card c. SMC PU card d. Communication card 14. The SF & EF units communicate with each other in FSK mode at _____________ baud rate. a. 1000 BPS b. 1400 BPS c. 1200 BPS d. 1600 BPS 15. The TX & RX signals will be in phase under _________condition. a. No Wheel / Axle b. Wheel / Axle c. Both a & b d. None of the above 16. The SSDAC system is suitable for axle detection for train speed up to _______KMPH a. 150 b. 200 c. 250 d. 300 17. The loop resistance of Quad cable is ___________ a. 58 ohms/Km b. 50 ohms/Km c. 56 ohms/Km d. 52 ohms/Km 18. The minimum voltage required for reset box is ___________ a. 24 V b. 12 V c. 18 V d. 48 V 19. ________ are used for avoiding damage to the detector coils. a. Reflectors b. Deflectors c. Sensors d. All of the above 20. The temperature, at which the system can work _________ a. +10°C to + 70°C b. - 20°C to + 80°C c. - 10°C to + 70°C d. - 10°C to + 60°C 21. The input voltage to the PD card from DC – DC converter is ___________ a. 24V b. -12V c. 12V d. 18V 22. The insulation resistance of Quad cable between conductors is more than ______ohms a. 10m b. 10M c. 10K d. 10 23. While trouble shooting, which error code displays for SM CPU missing? a. 3 b. 7 c. 6 d. 5 24. SSDAC system unit is housed near the track with its DP placed at a variable distance of _____ a. 10 Mtrs b. 25 Mtrs c. 15 Mtrs d. 30 Mtrs 25. The SM Event Logger logs up to ___________ no of events. a. 11000 b. 12000 c. 16000 d. 14000 26. The maximum RX signal induced voltage in an Axle counter is _____ a. 900mV to 1.2V AC b. 900mV to 1.2 V DC c. 300mV to 900mV AC d. 300mV to 900mV DC 27. The main purpose of two different frequencies provided in TX coils of Axle detectors is ____ a. To detect coil functioning b. To detect wheel direction c. To detect regular time period d. To count the no. of axles 28. Which type of MS Coupler no. is used for Reset in system evaluator ? a. 6 b. 8 c. 10 d. 11 29. In Trouble shooting , How many possible errors occurs in our system ? a. 61 b. 65 c. 62 d. 60 30. The Input voltage to drive relays in RD is ____ a. 48 b. 12 c. 24 d. 18
Digital Filmmaking: The Ultimate Guide to Web Video Production for Beginners and Non-Professionals, Learn Useful Tips and Advice on How You Can Create, Film and Edit Your Videos