DSE8610 MKII Data Sheet (US) PDF

You might also like

You are on page 1of 2

DSEGenset®

DSE8610 MKII SPECIFICATIONS

DC SUPPLY
CONTINUOUS VOLTAGE RATING
SYNCHRONISING AUTO START 5 V to 35 V Continuous

LOAD SHARE CONTROL MODULE CRANKING DROPOUTS


Able to survive 0 V for 100 mS, providing
supply was at least 10 V before dropout
and supply recovers to 5 V. This is
achieved without the need for internal
EXPANSION DEVICES batteries. LEDs and backlight will not be
• DSE124 CAN/MSC Extender maintained during cranking.
• DSE2130 Input Expansion
MAXIMUM OPERATING CURRENT
Module 530 mA at 12 V, 280 mA at 24 V
• DSE2131 Ratio-metric Input
Expansion Module MAXIMUM STANDBY CURRENT
320 mA at 12 V, 160 mA at 24 V
• DSE2133 RTD & Thermo-couple
Expansion Module CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
• DSE2152 Ratio-metric Output
Expansion Module GENERATOR & BUS
• DSE2157 Output Expansion VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
Module 26 V to 719 V AC (Ph to Ph)
• DSE2548 LED Expansion
FREQUENCY RANGE
3.5 Hz to 75 Hz

MAGNETIC PICKUP
KEY FEATURES outputs in CAN mode VOLTAGE RANGE
+/- 0.5 V to 70 V
• Comprehensive synchronising & • 4 configurable analogue/digital • Water in fuel digital input
loadsharing capabilities inputs • Fuel tank bund alarm digital input FREQUENCY RANGE
• Built in governor and AVR control • Built in sensors to support 0 V to 10 • Separate ramp up and ramp down 10,000 Hz (max)

• Base load (kW export) control V & 4 mA to 20 mA rates configurable via PLC INPUTS
• Positive & negative kVAr export • 12 configurable digital inputs • Configurable CAN message time- DIGITAL INPUTS A TO L
Negative switching
control • Configurable 5 stage dummy load outs
• Mains (Utility) decoupling protection and load shedding outputs • In-built SNMP ANALOGUE INPUTS A TO D
• 4-Line back-lit LCD text display • CAN, MPU and alternator frequency • Configurable CAN transmit & Configurable as:
Negative switching digital input
• Multiple Display Languages speed sensing in one variant receive 0 V to 10 V sensor
• Five key menu navigation • Real time clock • Battery chargers on DSENet® 4 mA to 20 mA sensor
0 Ω to 480 Ω sensor
• LCD alarm indication • Manual and automatic fuel pump
• Heated display option available control KEY BENEFITS OUTPUTS
• Customisable power-up text and • Engine run-time scheduler • Compatible in load share systems OUTPUT A & B (FUEL & StART)
15 A DC at supply voltage
images • Fuel usage monitor and low fuel containing DSE5500, DSE7500,
• DSENet expansion compatibility level alarms DSE8000 and DSE8600 MKII OUTPUTS C & D
• Data logging & trending facility • Simultaneous use of all series. Contact DSE for further 8 A AC at ­­­250 V AC (Volt-free)

• Internal PLC editor communication ports details AUXILIARY OUTPUTS E to L


• Protections disable feature • Remote SCADA monitoring via • 132 x 64 pixel ratio display for 2 A DC at supply voltage
• Fully configurable via PC using various DSE software applications clarity BUILT IN AVR GOVERNOR CONTROL
USB, RS232, RS485 & Ethernet • MODBUS RTU & TCP support with • Real-time clock provides accurate MINIMUM LOAD IMPEDANCE
communication configurable MODBUS pages for event logging 500 Ω
Fully isolated
• Front panel configuration with integration into building • Ethernet communication, provides
PIN protection management systems (BMS) builit in advanced remote GAIN VOLTAGE
0 V to 10 V DC
• Power save mode • Advanced SMS messaging monitoring. Fully isolated
• 3 phase generator sensing and (additional external modem required) • Can be integrated into building
protection • Start & stop capability via SMS management systems (BMS) and OFFSET VOLTAGE
0 V to 10 V DC
• Generator current and power messaging programmable logic control (PLC) Fully isolated
monitoring (kW, kvar, kVA, pf) • 3 configurable maintenance alarms • Increased input and output
• kW and kvar overload alarms • Compatible with a wide range of expansion capability via DSENet® DIMENSIONS
OVERALL
• Reverse power alarms CAN engines, including tier 4 • Licence-free PC software 245 mm x 184 mm x 51 mm
• Over current protection engine support • IP65 rating (with supplied gasket) 9.6” x 7.2” x 2.0”
• Unbalanced load protection • Uses DSE Configuration Suite PC offers increased resistance to water PANEL CUT-OUT
• Independent earth fault protection Software for simplified configuration ingress 220 mm x 160 mm
• Breaker control via fascia buttons • Power modes for when in parallel • Advanced Internal PLC editor 8.7” x 6.3”
• Fuel and start outputs configurable with the mains allows user configurable functions MAXIMUM PANEL THICKNESS
when using CAN • Redundant MSC communication to meet specific application 8 mm
0.3”
• 8 configurable DC outputs wired to CAN ports requirements.
• 2 configurable volt-free relay • True manual breaker control when STORAGE TEMPERATURE RANGE
-40 °C to +85 °C
RELATED MATERIALS -40 °F to +185 °F
TITLE PART NO.
OPERATING TEMPERATURE RANGE
DSE8610 MKII Installation Instructions 053-182 -30 °C to +70 °C
DSE8610 MKII Operator Manual 057-254 -40 °F to +185 °F
DSE8610 MKII PC Configuration Suite Manual 057-238 HEATED DISPLAY VARIANT
DSE8610 MKII Data Sheet 055-204 -40 °C to +70 °C
DSE8610 Data Sheet 055-083 -40 °F to +158 °F

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457 055-204/11/17 (2) US
DSEGenset®

DSE8610 MKII ENVIRONMENTAL TESTING STANDARDS

ELECTRO MAGNETIC COMPATIBILITY


BS EN 61000-6-2
SYNCHRONISING AUTO START EMC Generic Immunity Standard for the
Industrial Environment

LOAD SHARE CONTROL MODULE BS EN 61000-6-4


EMC Generic Emission Standard for the
Industrial Environment

ELECTRICAL SAFETY
The DSE8610 MKII is an easy to use Designed to offer increased built KEY LOAD SHARE FEATURES: BS EN 60950
Safety of Information Technology Equipment,
Synchronising Auto Start Control in support for active sensors for • Peak lopping/sharing (with including Electrical Business Equipment
Module suitable for use in a 0 V to 10 V & 4 mA to 20 mA. appropriate DSE mains controller)
multi-generator loadshare system, Comprehensive communication • Sequential set start TEMPERATURE
BS EN 60068-2-1
designed to synchronise up to 32 and system expansion options are • Manual voltage/frequency
Ab/Ae Cold Test -30 oC
generators including electronic and available. adjustment BS EN 60068-2-2
non-electronic engines. • R.O.C.O.F. and vector shift Bb/Be Dry Heat +70 oC
Using the DSE PC Configuration Suite protection
VIBRATION
The DSE8610 MKII monitors the Software allows easy alteration of the • Generator load demand BS EN 60068-2-6
generator and indicates operational operational sequences, timers and • Automatic hours run balancing Ten sweeps in each of three major axes
status and fault conditions, alarms. With all communication ports • Mains (Utility) decoupling 5 Hz to 8 Hz at +/-7.5 mm, 8 Hz to 500 Hz
at 2 gn
automatically starting or stopping capable of being active at the same • Mains (Utility) decoupling
the engine on load demand or fault time, the DSE8610 MKII is ideal for a test mode HUMIDITY
condition. wide variety of demanding load share • Dead bus sensing BS EN 60068-2-30
applications. • Bus failure detection Db Damp Heat Cyclic 20/55 oC at 95% RH
48 Hours
System alarms are annunciated on • Direct governor and AVR control BS EN 60068-2-78
the LCD screen (multiple language • Volts and frequency matching Cab Damp Heat Static 40 oC at 93% RH
options available), illuminated LED • kW and kvar load sharing 48 Hours
and audible sounder.­­ • Dead bus synchronising SHOCK
BS EN 60068-2-27
The event log will record 250 events Three shocks in each of three major axes
15 gn in 11 mS
to facilitate easy maintenance, and an
extensive number of fixed and flexible DEGREES OF PROTECTION
monitoring, metering and protection PROVIDED BY ENCLOSURES
features are included. BS EN 60529
IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE


VARIETY OF LOAD SHARE APPLICATIONS
DSE2130
DSE2131 MODEM MODBUS PC
DSE2133
DSE2152 2 12 8 4
DSE2157
DSE2548 232 485

DSENET® RS232 AND USB USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT HOST INPUTS SENDERS STOP SUPPLY 8-35V

ETHERNET
+

DEUTZ DETROIT
DSE8610 MKII MSC
ISUZU
PERKINS
IVECO
JOHN DEERE
CATERPILLAR LOMBARDINI
MTU SISU
7 VOLVO JCB DIESELMAX
55xx 75xx 8xxx 8xxx MKII
CUMMINS YANMAR
OTHER SCANIA AND OTHERS

BUS VOLT FREE GENERATOR SENSING FUEL & START CHARGE ELECTRONIC MAGNETIC
SENSING OUTPUTS OUTPUTS ALTERNATOR ENGINES PICK-UP
CURRENT VOLTS D+
+ W/L

1ph 2 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E/N N

ISSUE 3

You might also like