You are on page 1of 19

TECHNOLOGY AGM FLAT PLATE GEL TUBULAR GEL

PRODUCT PTNW‐FT PTNW‐GFM‐C PTNW‐GFMG PTNW‐GFM‐H PTNW‐GFM‐HT PTNW‐FTJ PTNW‐GFMJ PTNW‐OPZV


APPLICATION SELECTION

2V               
2V                2V                2V               
RATED VOLTAGE 12V 6V                2V 12V 2V
6V 12V 12V
12V
2V: 15 years      
DESIGN LIFE  FTA: 12 years      10 years           2V: 15 years      
6V: 10 years       12 years 18 years 10 years 18 years
(25°C) FTB: 10 years (35°C) 12V: 12 years
12V: 10 years

CAPACITY RANGE 55Ah ~ 175Ah 200Ah ~ 3000Ah 105Ah ~ 560Ah 800Ah ~ 2000Ah 300Ah ~ 1000Ah 100Ah ~ 150Ah 33Ah ~ 2000Ah 150Ah ~ 3000Ah

CYCLE 
       
PERFORMANCE

HIGH TEMP 
       
PERFORMANCE

COST 
       
ADVANTAGE
PTNW‐FT series VRLA battery uses AGM technology 
with narrow structure design. It has good heat 
dissipation performance and floating standby 
performance, specially designed for gas gathering and 
exhaust system, effectively ensuring the security of the 
system.

PTNW‐FT series is designed especially for 19' and 23 ' 
power supply cabinets for communication systems, 
mainly applicable for small outdoor base stations. 

It includes two types FTA and FTB.

PRODUCT FEATURES
▪ Rated Voltage: 12V
▪ Capacity Range (C10):  55Ah~175Ah (25°C) STANDARDS
▪ Product Technology:  AGM valve regulated technology
▪ Self‐Discharge Rate:  ≤1.5% (Monthly, 25°C) ▪ IEC60896‐21/22 : 2004
▪ Design Life (25°C):  12 years for PTNW‐FTA, 10 years for PTNW‐FTB ▪ BS 6290‐4 : 199
▪ Product Structure:  Long and narrow front terminal structure for easy ▪ YD/T799‐2010
installation and maintenance. ▪ ISO9001 certified
Compatible with 19' and 23' power supply cabinet ▪ ISO14001 certified
for communications systems. ▪ OHSAS 18001 certified
▪ Usage:  Float charge standby plus some shallow ▪ UL and CE certified
cycling power supply mode
▪ Operating  ‐15°C~50°C
Temperature Range Recommended operating temperature 15°C~30°C

TERMINAL TYPES

FT‐51 FT‐52 FT‐53

FT‐54 FT‐55 FT‐57


MAIN PARAMETERS

RATED  DIMENSIONS
SHORT 
RATED  CAPACITY  WEIGHT INTERNAL 
L W H CIRCUIT  TERMINAL 
MODEL VOLTAGE  C10  RESISTANCE 
CURRENT  TYPE
(V) 1.80V/cell  (mΩ, 25C)
mm mm mm kg (A)
(Ah)
PTNW‐FTB12‐55 12 55 277 106 222.5 17 1412 8.5 FT‐51
PTNW‐FTB12‐80 12 80 395 110 288 27.5 2300 5.2 FT‐52
PTNW‐FTB12‐95 12 95 395 105 270 28.5 2500 4.8 FT‐54
PTNW‐FTB12‐100II 12 100 395 110 288 33.2 2720 4.5 FT‐57
PTNW‐FTB12‐100 12 100 395 110 288 34.5 2720 4.4 FT‐52
PTNW‐FTB12‐105 12 105 508 110 238 35.4 2920 4.1 FT‐54
PTNW‐FTB12‐125 12 125 551 110 288 39.5 3000 4 FT‐53
PTNW‐FTB12‐150II 12 150 551 110 288 46 3200 3.6 FT‐57
PTNW‐FTB12‐150 12 150 551 110 288 48.3 3200 3.6 FT‐53
PTNW‐FTB12‐165 12 165 551 110 288 49 3650 3.6 FT‐53
PTNW‐FTA 12‐100II 12 100 558 125 230 36.3 2650 4.8 FT‐55
PTNW‐FTA 12‐100 12 100 558 125 230 38 2500 4.8 FT‐55
PTNW‐FTA12‐105 12 105 558 125 230 36.5 2650 4.25 FT‐55
PTNW‐FTA 12‐110 12 110 558 125 230 36.5 2650 4.25 FT‐55
PTNW‐FTA12‐125 12 125 558 125 270 45.2 3000 4 FT‐55
PTNW‐FTA 12‐150 12 150 558 125 311 54.5 3200 3.6 FT‐55
PTNW‐FTA 12‐160 12 160 558 125 311 55 3350 3.3 FT‐55
PTNW‐FTA 12‐175 12 175 558 125 311 55 3650 3.3 FT‐55
PTNW‐GFM‐C series VRLA battery uses AGM 
technology with long floating standby life, applicable  to 
less frequency of power failure and shallow discharge 
depth site.

Meets international standards and is mainly used for 
indoor communication base stations. 

PRODUCT FEATURES
STANDARDS
▪ Rated Voltage: 2V, 6V, 12V
▪ Capacity Range (C10):  2V:100Ah~3000Ah (25°C) ▪ IEC60896‐21/22 : 2004
6V:200Ah (25°C) ▪ GB/T19638.2‐2005
12V:80Ah~200Ah (25°C) ▪ YD/T799‐2010
▪ Product Technology:  AGM valve regulated technology ▪ JIS C8704‐1 : 2006
▪ Self‐Discharge Rate:  ≤1% (Monthly, 25°C) ▪ JIS C8704‐2 : 2006
▪ Design Life (25°C):  15 years for 2V and 10 years for 6Vand 12V ▪ DL/T 637‐1997
▪ Usage:  Float charge standby plus some shallow ▪ ISO9001 certified
cycling power supply mode ▪ ISO14001 certified
▪ Operating  ‐15°C~45°C ▪ OHSAS 18001 certified
Temperature Range Recommended operating temperature 15°C~30°C

TERMINAL TYPES

GFM‐12 GFM‐21 GFM‐22

GFM‐25 GFM‐27
MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
RATED  CAPACITY  INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  (Ah@25°C) L W H RESISTANCE 
CURRENT  TYPE
(V) kg (mΩ, 25C)
10hr  (A)
mm mm mm
1.80V/Cell
PTNW‐GFM‐100C 2 100 172.5 65 205 5.3 2700 0.65 GFM‐25
PTNW‐GFM‐200C 2 200 98.5 174 348.5 13.5 3100 0.50 GFM‐21
PTNW‐GFM‐300C 2 300 141 174 348.5 19 3900 0.43 GFM‐21
PTNW‐GFM‐400C 2 400 175 174 348.5 24 4900 0.36 GFM‐21
PTNW‐GFM‐500C 2 500 213.5 174 348.5 30 5200 0.34 GFM‐21
PTNW‐GFM‐600C 2 600 252 175 348.5 36 5600 0.36 GFM‐21
PTNW‐GFM‐800C 2 800 350 173 338 49 7200 0.19 GFM‐21
PTNW‐GFM‐1000C 2 1000 430 173 338 59.5 8600 0.17 GFM‐21
PTNW‐GFM‐1200C 2 1200 510 175 338 71.5 9000 0.18 GFM‐27
PTNW‐GFM‐1500C 2 1500 318 341 341 86.5 11500 0.18 GFM‐27
PTNW‐GFM‐2000C 2 2000 433 342 341 118 13400 0.10 GFM‐27
PTNW‐GFM‐3000C 2 3000 629 346 341 174 20000 0.09 GFM‐27
PTNW‐3GFM‐200 6 200 375 170 211 33 4000 1.5 GFM‐12
PTNW‐6GFM‐80 12 80 329 172 215.5 29.3 1935 6.2 GFM‐22
PTNW‐6GFM‐100 12 100 407 173 222 36.5 2400 5.0 GFM‐22
PTNW‐6GFM‐150 12 150 497 203 228 53.6 3150 3.8 GFM‐22
PTNW‐6GFM‐200 12 200 497 259 228 70 4120 2.9 GFM‐22
PTNW‐GFMG series VRLA battery is a large capacity high 
power battery using AGM technology, wide low 
structure design with small electrolyte stratification.

It has good floating and high power discharge 
performance. 

Mainly used in UPS/EPS and other stand‐by power 
systems.

PRODUCT FEATURES
▪ Rated Voltage: 2V, 6V
STANDARDS
▪ Capacity Range (C10):  105Ah~560Ah (25°C)
▪ Self‐Discharge Rate:  ≤1% (Monthly, 25°C) ▪ GB/T19638.2‐2005
▪ Design Life (25°C):  12 years ▪ IEC 60896‐21/22 : 2004
▪ Product Structure: Wide low structure, small electrolyte ▪ ISO9001 certified
stratification ▪ ISO14001 certified
Good high power discharge performance ▪ OHSAS 18001 certified
▪ Usage:  Float charge standby plus some high 
power discharge
▪ Operating  ‐15°C~45°C
Temperature Range Recommended operating temperature 15°C~30°C

TERMINAL TYPES

GFM‐23 GFM‐30 GFM‐31


MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
RATED  CAPACITY  INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  (Ah@25°C) L W H RESISTANCE 
CURRENT  TYPE
(V) kg (mΩ, 25C)
10hr  (A)
mm mm mm
1.80V/cell
PTNW‐GFMG‐200 2 200 110 208 242 13.5 3200 0.58 GFM‐23
PTNW‐GFMG‐275 2 275 142 205 242 18.1 3600 0.52 GFM‐30
PTNW‐GFMG‐300 2 300 142 205 242 18.6 4100 0.48 GFM‐30
PTNW‐GFMG‐320 2 320 195 206 220 22.8 4500 0.47 GFM‐23
PTNW‐GFMG‐400 2 400 195 208 253 25.6 5100 0.42 GFM‐23
PTNW‐GFMG‐455 2 455 296 203 222 32.6 5200 0.40 GFM‐30
PTNW‐GFMG‐515 2 515 296 203 222 34.7 5400 0.38 GFM‐30
PTNW‐GFMG‐560 2 560 296 203 222 36.1 5700 0.36 GFM‐30
PTNW‐3GFMG‐105 6 105 195 206 220 22.4 945 2.62 GFM‐23
PTNW‐3GFMG‐125 6 125 278 178 238 25.5 1000 2.63 GFM‐30
PTNW‐3GFMG‐160 6 160 278 178 238 30.6 1200 2.47 GFM‐30
PTNW‐3GFMG‐200 6 200 250.5 125.5 362 33.7 1400 1.55 GFM‐31
PTNW‐GFM‐H series batteries uses AGM technology 
with single large capacity, thick plate structure design, 
has longer floating life and high floating consistency.

The battery uses modular combination, horizontal 
structure design, according to user needs . Free 
combination of battery module height, convenient 
installation and maintenance, saving space
effectively.

Mainly applicable to the center of room or high
floating consistency requirements places.

PRODUCT FEATURES
▪ Rated Voltage: 2V
STANDARDS
▪ Module Voltage: 4V, 6V, 8V
▪ Capacity Range (C10):  800Ah~2000Ah (25°C) ▪ GB/T19638.2‐2005
▪ Self‐Discharge Rate:  ≤1% (Monthly, 25°C) ▪ YD/T799‐2010
▪ Design Life (25°C):  18 years ▪ DL/T 637‐1997
▪ Product Structure: High capacity monomer structure design ▪ IEC60896‐21/22 : 2004
Horizontal installation, modular combination ▪ ISO9001 certified
and multilayer stacks ▪ ISO14001 certified
▪ Usage:  Float charge standby plus short time high
current stand‐by back‐up mode
▪ Operating  ‐15°C~45°C
Temperature Range Recommended operating temperature 15°C~30°C
MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
MODULE  CAPACITY  INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  (Ah@25°C) L W H RESISTANCE 
CURRENT  TYPE
(V) kg (mΩ, 25C)
C10           (A)
mm mm mm
1.80V
PTNW‐4GFM‐800H 8 800 615 780 295.5 238.3 6000 0.36 GFM‐26
PTNW‐4GFM‐800H 6 1000 615 835 258 218.1 7600 0.31 GFM‐26
PTNW‐4GFM‐800H 6 1200 615 835 294.5 256.9 8700 0.22 GFM‐26
PTNW‐4GFM‐800H 4 1500 615 705 295.5 215.1 11000 0.20 GFM‐26
PTNW‐4GFM‐800H 4 2000 615 855 299 270.6 13000 0.28 GFM‐26
PTNW‐GFM‐HT series VRLA battery uses AGM 
technology which is designed for high temperature 
resistant performance with good cycle life and fast 
charging acceptance capability. 

Can be used in the range of 35‐40°C environment. 
Suitable for high temperature environments for floating 
or cyclic applications. 

It can effectively reduce the energy consumption of 
airconditioning.

PRODUCT FEATURES
▪ Rated Voltage: 2V
STANDARDS
▪ Capacity Range (C10):  300Ah~1000Ah (25°C)
▪ Self‐Discharge Rate:  ≤1% (Monthly, 25°C) ▪ GB/T 22473‐2008
▪ Design Life (35°C):  10 years ▪ YD/T799‐2010
▪ Product Technology:  AGM, valve regulated technology ▪ JIS C8704‐1 : 2006
▪ Product Structure: High capacity monomer structure design ▪ JIS C8704‐2 : 2006
Horizontal installation, modular combination ▪ IEC 60896‐21/22 : 2004
and multilayer stacks ▪ IEC 61427‐2005
▪ Usage:  Float charge standby plus some shallow cycling
power supply mode
▪ Operating  ‐20°C~75°C
Temperature Range Can be used in 35°C~40°C environment for a long time
Recommended operating temperature 15°C~40°C

TERMINAL TYPES

GFM‐21
MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
RATED  CAPACITY  INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  (Ah@25°C) L W H RESISTANCE 
CURRENT  TYPE
(V) kg (mΩ, 25C)
C10           (A)
mm mm mm
1.80V
PTNW‐GFM‐300HT 2 300 154 176 337 21.5 3900 0.34 GFM‐21
PTNW‐GFM‐400HT 2 400 201 177 337 29 5000 0.30 GFM‐21
PTNW‐GFM‐500HT 2 500 248 177 337 35.5 5500 0.28 GFM‐21
PTNW‐GFM‐600HT 2 600 296 178 337 43 6600 0.35 GFM‐21
PTNW‐GFM‐800HT 2 800 390 177 337 57 10000 0.15 GFM‐21
PTNW‐GFM‐1000HT 2 1000 484 177 337 71 11000 0.14 GFM‐21
PTNW‐FTJ series VRLA GEL battery uses German
technology with narrow structure design. It has good 
heat dissipation performance and the floating standby 
performance,specially designed for gas gathering and 
exhaust system, effectively ensuring the security of the 
system. 

PTNW‐FTJ series is designed especially for 19' and 23' 
power supply cabinets for communication systems, 
mainly applicable for small outdoor base stations. It is 
more suitable for harsh environment of high‐low 
temperature and poor backup power supply conditions.

PRODUCT FEATURES
▪ Rated Voltage: 12V
STANDARDS
▪ Capacity Range (C20):  100Ah~150Ah (25°C)
▪ Self‐Discharge Rate:  ≤2% (Monthly, 25°C) ▪ IEC60896‐21/22 : 2044
▪ Design Life (25°C):  10 years ▪ DIN43539‐T5 1984
▪ Product Technology:  Flat Gel VRLA technology ▪ YD/T1360‐2005
▪ Product Structure: High capacity monomer structure design ▪ ISO9001 certified
Horizontal installation, modular combination ▪ ISO14001 certified
and multilayer stacks ▪ OHSAS18001 certified
▪ Usage:  Float charge standby plus shallow cycling
power supply mode
▪ Operating  ‐20°C~55°C
Temperature Range Recommended operating temperature 15°C~35°C

TERMINAL TYPES

FT‐55 FT‐57
MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
RATED  CAPACITY   INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  C20    L W H RESISTANCE 
CURRENT  TYPE
(V) 1.75V/cell  kg (mΩ, 25C)
(A)
(Ah) mm mm mm
PTNW‐6FTJ‐100A 12 100 558 125 230 38.5 2100 4.80 FT‐55
PTNW‐6FTJ‐100A 12 100 395 110 288 33.8 2100 5.50 FT‐57
PTNW‐6FTJ‐100A 12 125 558 125 270 45.7 2500 4.37 FT‐55
PTNW‐6FTJ‐100A 12 142 551 110 288 45 2700 4.33 FT‐57
PTNW‐6FTJ‐100A 12 150 546 125 311 53.7 3000 4.33 FT‐55
PTNW‐GFMJ series gel battery, uses German advanced 
gel battery production technology .

This series has a good cycle and high‐low temperature 
performance, good charge
acceptance ability and can be used in high‐low 
temperature environment, poor power condition and 
pure cycle use communication base station.

PRODUCT FEATURES
STANDARDS
▪ Rated Voltage: 2V, 12V
▪ Capacity Range (C10):  33Ah~2000Ah (25°C) ▪ IEC60896‐21/22 : 2044
▪ Self‐Discharge Rate:  ≤2% (Monthly, 25°C) ▪ IEC61427‐2005
▪ Design Life (25°C):  15 years for 2V and 12 years fro 12V ▪ DIN43539‐T5 1984
▪ Usage:  Float charge standby and can be used in deep, ▪ YD/T1360‐2005
shallow cycle applications ▪ GB/T 22473‐2008
▪ Operating  ‐20°C~55°C ▪ ISO9001 certified
Temperature Range Recommended operating temperature 15°C~30°C ▪ ISO14001 certified

TERMINAL TYPES

SP‐27 GFM‐24 GFM‐22


MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
RATED  CAPACITY   INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  C10    L W H RESISTANCE 
CURRENT  TYPE
(V) 1.80V/cell  kg (mΩ, 25C)
(A)
(Ah) mm mm mm
PTNW‐6GFMJ‐33 12 33 198 166 170 14 1010 8.5 SP‐27
PTNW‐6GFMJ‐50 12 50 276 174 169 21 1525 7.64 GFM‐24
PTNW‐6GFMJ‐65 12 65 310 174 209 30 1540 7.35 GFM‐24
PTNW‐6GFMJ‐85 12 85 414 174 218 37 2060 5.85 GFM‐24
PTNW‐6GFMJ‐100 12 100 513 163 218 44 2950 3.91 GFM‐24
PTNW‐6GFMJ‐120 12 120 513 232 218 52.3 2980 3.86 GFM‐24
PTNW‐6GFMJ‐150 12 150 513 232 218 63.8 3020 3.65 GFM‐24
PTNW‐6GFMJ‐200 12 200 513 296.5 218 82.8 3050 3.2 GFM‐24
PTNW‐6GFMJ‐200II 12 200 497 259 228 72.6 3050 2.82 GFM‐22
PTNW‐GFMJ‐200 2 200 171 107 334 14.8 2800 0.68 GFM‐22
PTNW‐GFMJ‐300 2 300 171 151 334 21.3 3600 0.54 GFM‐22
PTNW‐GFMJ‐400 2 400 211 175 334 30 4350 0.45 GFM‐22
PTNW‐GFMJ‐500 2 500 243 174 334 35.5 5020 0.39 GFM‐22
PTNW‐GFMJ‐600 2 600 302 177 334 44 5860 0.33 GFM‐22
PTNW‐GFMJ‐800 2 800 410 175 334 60 6900 0.28 GFM‐22
PTNW‐GFMJ‐1000 2 1000 478 175 334 71 8000 0.24 GFM‐22
PTNW‐GFMJ‐1200 2 1200 346 310 335 85.5 9600 0.17 GFM‐22
PTNW‐GFMJ‐1500 2 1500 401 351 340 107 12000 0.14 GFM‐22
PTNW‐GFMJ‐2000 2 2000 490 350 340 140 16000 0.12 GFM‐22
PTNW‐OPzV series gel batteries uses German tubular pure 
gel technology.

Tests prove that the battery has superior service life and 
reliabil ity, good cycling performance and charge 
acceptance ability.

It can be used in high‐low temperature environment, poor 
power condition and pure cycle use in solar energy, wind 
energy and various types of
communication base stations.

PRODUCT FEATURES
STANDARDS
▪ Rated Voltage: 2V
▪ Capacity Range (C10):  150Ah~3000Ah (25°C) ▪ IEC60896‐21/22 : 2044
▪ Self‐Discharge Rate:  ≤3% (Monthly, 25°C) ▪ IEC61427‐2005
▪ Design Life (25°C):  18 years ▪ DIN43539‐T5 1984
▪ Usage:  Float charge standby and can be used in deep, ▪ DIN40742 : 1999
shallow and PSOC state cycling ▪ GB/T 22473‐2008
▪ Operating  ‐20°C~60°C ▪ ISO9001 certified
Temperature Range Recommended operating temperature 15°C~35°C ▪ ISO14001 certified
▪ Shelf Life: Fully charged, static stored for 2 years and battery 
remaining capacity is still more than 50% of the 
rated capacity.
Aftre charging, the battery capacity can be restored
to 100% of the rated capacity.

TERMINAL TYPES

GFM‐28 GFM‐29
MAIN PARAMETERS

RATED  DIMENSIONS WEIGHT


SHORT 
RATED  CAPACITY   INTERNAL 
CIRCUIT  TERMINAL 
MODEL VOLTAGE  C10    L W H RESISTANCE 
CURRENT  TYPE
(V) 1.80V/cell  kg (mΩ, 25C)
(A)
(Ah) mm mm mm
PTNW‐GFMJ‐150H 2 150 103 206 352.5 15 1125 0.80 GFM‐28
PTNW‐GFMJ‐200H 2 200 103 206 352.5 18 2000 0.75 GFM‐28
PTNW‐GFMJ‐250H 2 250 124 206 352.5 22 1500 0.70 GFM‐28
PTNW‐GFMJ‐300H 2 300 145 206 352.5 25.5 3000 0.60 GFM‐28
PTNW‐GFMJ‐350H 2 350 124 206 471 28 3600 0.58 GFM‐28
PTNW‐GFMJ‐420H 2 420 145 206 471 33.5 4200 0.55 GFM‐28
PTNW‐GFMJ‐490H 2 490 166 206 471 37.5 4900 0.50 GFM‐28
PTNW‐GFMJ‐500H 2 500 166 206 471 37.5 5000 0.50 GFM‐28
PTNW‐GFMJ‐600H 2 600 145 206 646 46.5 6000 0.45 GFM‐28
PTNW‐GFMJ‐800H 2 800 191 210 646 62 8000 0.40 GFM‐28
PTNW‐GFMJ‐1000H 2 1000 233 210 646 77.5 9500 0.35 GFM‐28
PTNW‐GFMJ‐1200H 2 1200 275 210 646 91.5 11500 0.30 GFM‐28
PTNW‐GFMJ‐1500H 2 1500 340 210 646 112.5 14250 0.24 GFM‐28
PTNW‐GFMJ‐2000H 2 2000 399 212 772 153 15000 0.22 GFM‐29
PTNW‐GFMJ‐2500H 2 2500 487 212 772 187 17500 0.17 GFM‐29
PTNW‐GFMJ‐3000H 2 3000 576 212 772 222 23000 0.12 GFM‐29

You might also like