You are on page 1of 5

PRATHAM EPC PROJECTS PVT. LTD.

PROJECT KHEDA GA CGD Projects_ADANI

OWNER ADANI GAS LIMITED


TPIA TUV INDIA PVT. LTD.

D: Chemical Analysis Results :


Report No. : ME/TG25/70
Date:01/08/2019
%C %SI %Mn %S %P %Ni %Cr %Mo %V
Actual Value 0.142 0.177 0.501 0.012 0.008 <0.05 <0.05 <0.010 0.006
Remark On Chemical Analysis Result : Accepted

E. Transverse Tensile Test :


Report No. : ME/TG25/70
Date:01/08/2019
Thickness
Width Area(MM2) U.T.S N/MM2 Remark
(mm)
Actual 19.08 16.02 305.66 464.63

Required -- -- -- 410 Mn.


Remark OnTranseverse Tensile Test Result : Accepted

Test Conducted by M/s PRATHAM EPC PROJECTS PVT. LTD.


Destructive Test Conducted by M/s Metalab Enterprise
The Statements in this record are correct. The test joints were prepared, welded and tested in
accordance with requirement of specification.

For, PEPC For TPIA For AGL


PRATHAM EPC PROJECTS PVT. LTD.

PROJECT KHEDA GA CGD Projects_ADANI

OWNER ADANI GAS LIMITED


TPIA TUV INDIA PVT. LTD.

Yield Point
UTS. N/mm2 Elongation % Remark
N/mm2

Actual 510.02 409.14 22.69


Required
Min. 430 330 22
Remark on All Weld Tensile Test Result : Accepted

C. Impact Test Results


Report No. : ME/TG25/70
Test Temperature- -30° C Date:01/08/2019

Required Value in
Average Value Joules
Location Size mm Energy absorbed in Joules/CM2 in Joules
IR1 IR2 IR3
27 J Min Avg.
weld 10 X10 57.33
74 44 54
20 J Min. Individual
Remark on Impact Test Result : Accepted

Joint Design

20°+5°

16 mm

13 mm Backing Strip

Single V Butt Joint


0 PRATHAM EPC PROJECTS PVT. LTD.

PROJECT KHEDA GA CGD Projects_ADANI

OWNER ADANI GAS LIMITED


TPIA TUV INDIA PVT. LTD.

A Tested at (Location) : Metalab Enterprise- Ahmedabad

Date of Testing : 06/11/2018

Manufracture’s Name : Lincoln Electric

Brand Name : Lincoln

Batch Number & Size tested : 16020415 - 3.2 mm Dia X 350 mm Long

Classification & Code :ASEME SEC II Part C SFA 5.1

Intended for Welded in Position : 1G

In Combination With (if Any) : NA

Code of reference (used for testing) : ASME SEC II PART C & AGL Specification

Special Requirement (If Any) : Transverse Tensile

B All-WELD Tensile Test


Report No. : ME/TG25/70 Date:01/08/2019

Base Material Used : IS 2062 GR. E250BR

Pre- Heat Temp. : 100° C Min.

Post Weld Heat : NA

Post Weld Heat : NA

Visual Examination : Accepted

Radiographic Examination Results : Accepted


PRATHAM EPC PROJECTS PVT. LTD.

PROJECT KHEDA GA CGD Projects_ADANI

OWNER ADANI GAS LIMITED


TPIA TUV INDIA PVT. LTD.

ELECTRODE QUALIFICATION TEST RECORD


FOR
E6010-3.2 MM, BATCH NO. -15400391

0 12/11/19
Prepared By Checked By Reviewed By Approved By
Rev Date Description PEPC PEPC TPIA AGL

You might also like