Quality is never achieved by luck, default or chance. It requires planned, systematic
and consistent efforts.
The inspection starts with incoming raw material to manufacturing, assembly &
Testing. The reason for inspection is that the parts manufactured vary during
manufacturing process due to ‘Assignable cause & Chance cause’ (see section II).
Engineering metrology deals with high precision measurements & calibration.
Objectives of metrology: Evaluate new product development, analyze accuracy of
measurement, determine process capability, calibration of measuring instruments,
develop new methods, maintain accuracy of inspection, build-up special gauges
and stastical quality control through record.
Atmospheric conditions Metrology lab.
a) Temperature: 20O ± centigrade
b) Relative Humidity: 45 ± 10%. If high-corrosion & sweating. If low, Static charge.
c) Barometer pressure: 10 to 20 N/m2 extra.
d) Air velocity: 0.71 ± 0.28 m3/minute inside the lab...
e) Dust particle count: upto 0.5 μ. & so e Ante-room with glass door is provided.
f) Acoustic noise: 45-60 db (Decibels).
g) Illumination: 450-700—Lux on inspection table with CFL lamp.
h) Vibration: 0.001 gm.
LINE standard END standard WAVE LENGTH Std.
Examples: Imperial Slip gauges, Micrometers, Uses monochromatic
std. yard, Meter, length bars. light of Krypton 86 (or
Laser etc.).
Yard = 36 inch = Set of standard bars. 1 Meter = 1650763.73
0.914400 meter. Gold wavelength of Krypton
inserts in Bronze bar. 86
It is distance between It is distance between 2 Uses Optics, mirror,
2 engraved lines. ends. rays to align with
cross wire,
Can’t give precise value Provides precision Provides very high
of measurement. measurement. precision value.
Quick to measure. Time consuming. Takes time, costly.
Not subjected to wear. Subject to wears. No wear. It is light source.
Parallax error, affected Gives direct reading. There Gives direct reading.
by temperature. can be errors of Not affected by
Requires judgment measurement due to temp. environment.
Simple, but Comparatively more Requires training
inconvenient. complex.
Does not require Calibration & setting Training required
calibration or training required due to wear.
Training reqd.
Not useful for Used in precision Can be used for
interchangability, measurement. measurement &
various type of fit calibration.
2 MQC (Measurements)
Precision Accuracy
It is repeatability of measuring It is agreement of measurement of job
instrument. with drawing dimension.
Related to instrument or CNC machine Related to job
Expressed as Least count Measured as tolerance on job e.g. ±
/Repeatability/Positional accuracy. Etc 0.10
Precision is constant for instrument or m/c. Accuracy can vary according to fit.
Important to measure accuracy of job Important for interchangability & fit.
Compared with reference standard. Checked by Go No-Go gauges/instrument.
No relation with job accuracy Direct relation with type of fit.
Precision has international standard Choice of designer.
Cost to maintain a precision is Higher the accuracy of job, higher is
constant the cost of manufacture.
Measuring instruments
Micrometers
4 MQC (Measurements)
V block with clamp
Surface plate