Professional Documents
Culture Documents
The quickest, simplest way to develop material ‘solidification path’ broadly includes mass fractions and
datasets is to utilise thermodynamic simulation software compositions of all solid phases that form during
packages. Using information from thermodynamic solidification, the term is frequently used in a narrower
databases, these packages model multicomponent metal sense in this text, as shorthand notation to refer simply
alloy solidification to generate a solidification path. The to the solid fraction as a function of temperature, which
solidification path consists of mass fractions and is the only part of the broader set of information utilized
compositions of the various solid phases that form as in casting simulation software) and the evolution of
a function of temperature during solidification. This latent heat; the specific heat, density, thermal con-
information is then used to determine the latent heat and ductivity and viscosity are generally less sensitive to
temperature dependent data for the specific heat and potential inaccuracies in the predictions of the thermo-
density. Two different thermodynamic simulation soft- dynamic software. In order to generate reliable material
ware packages are utilised in the present study: the datasets for the corrosion resistant alloys currently of
stainless steels are simulated using the interdendritic interest, it is necessary to collect temperature data that
solidification package IDS (IDS DOS v2?0?0) developed can be used to verify the calculated solidification path
by Miettinen1 and Miettinen and Louhenkilpi,2 and the and enthalpy related properties for these alloys. Note
nickel based alloys are simulated using JMatPro.3 Many that although it is commonly referred to as a property,
such software packages are commercially available; the solidification path is, in reality, a function of the
these two were selected in part because in addition to cooling rate. Thus, it would be advantageous to
generating a solidification path and thermodynamic determine the solidification path for cooling rates similar
properties, they also produce transport property curves to those seen in production castings.
(i.e. thermal conductivity and viscosity) required by There are two common laboratory methods for
casting simulation software. IDS is only applicable to measuring solidification and enthalpy related properties:
steels, whereas JMatPro can be applied to a wider range differential thermal analysis (DTA) and differential
of alloys (including nickel based alloys). IDS calculates scanning calorimetry (DSC). In DTA, thermocouples
the transient diffusion of solutes within the phases on (TCs) are used to measure temperature differences
the scale of the microstructure and is thus able to during the heating or cooling of a small (,200 mg)
account for the effect of back diffusion on the solidi- sample of a metal alloy.4 The nature of these tempera-
fication path and to simulate the solid state transforma- ture changes indicates different events that occur during
tions that often occur in steels. JMatPro, on the other solidification and melting. The DSC approach is similar
hand, uses a modified Scheil approximation (i.e. no to DTA, but differences in heat flow are measured rather
solute diffusion in solid phases, except for carbon and than temperature differences. Measurements from DTA
nitrogen, for which diffusion in the solid is assumed to and DSC can provide a great deal of useful information
be complete). for metal alloys.4 However, while the liquidus tempera-
For many common casting alloys, the datasets ture and the latent heat can be readily determined with
generated by thermodynamic software packages are these methods, the non-equilibrium solidus temperature
reasonably accurate. However, for the highly alloyed is potentially more elusive. As noted in Ref. 4, deter-
metals considered in the present study, material datasets mination of the solidus temperature [in the following,
determined from thermodynamic simulation software the term ‘solidus temperature’ is used as shorthand
are not entirely trustworthy. Sometimes, the content of a notation to indicate the (non-equilibrium solidus) tem-
particular solute is simply out of the range for which the perature at which an alloy becomes fully solid upon
software was designed, or the thermodynamic database cooling.] can be difficult with DSC/DTA. This is
on which the software is based is not fully validated for particularly true for alloys like steel, where the end of
very high solute contents. More often, the accuracy of solidification is not associated with the formation of a
the modified Scheil approximation or even the diffusion new phase (e.g. a eutectic phase). In addition, the solidus
calculations is not known. This uncertainty affects temperatures of steels are generally a strong function of
primarily the solidification path (although the term the cooling rate, and cooling rates during solidification
Alloy
of castings are highly variable and often unknown. Again, casting experiments are performed using a small
Therefore, selecting a representative cooling rate to cylindrical sample in a cup. In contrast to Newtonian
use in DSC/DTA measurements can be a challenge. analysis, Fourier analysis does not assume a uniform
Commercial DSC/DTA systems may not even allow for temperature but accounts for heat conduction within
tests to be conducted at the cooling rates encountered in the solidifying metal. This requires knowledge of the
production castings. Finally, it is difficult to back out temperature distribution in the casting sample, which is
the full solid fraction versus temperature relationship gained using two TCs in the metal rather than one: in
from DSC/DTA measurements. addition to a central TC, there is also a TC located near
Solidification characteristics such as the liquidus and the edge of the cylinder. An energy balance then
solidus temperatures, the latent heat of solidification and provides an equation for dT/dt in terms of a conduction
the solidification path can also be determined using data term and a latent heat source term. Assuming that heat
from TCs embedded in small experimental castings. This transfer in the cylindrical sample occurs only radially,
method is referred to as cooling curve analysis (CCA).5–10 with no heat transfer from the cylinder ends, the time
Taking the time derivative of a measured temperature dependent value of the conduction term is determined
curve T(t) yields the cooling rate curve dT/dt. The from an analytical expression involving the measured
liquidus and solidus temperatures are taken directly temperatures. This conduction term is then designated
from this cooling rate curve; this will be discussed in the Fourier zero curve, which serves the same purpose as
detail later. Two methods are commonly used to the Newtonian zero curve. The Fourier zero curve can
determine the latent heat of solidification and the be expected to be more accurate than the Newtonian
solidification path: Newtonian analysis5 and Fourier zero curve, but it is still only approximate. The
analysis.6 These methods are briefly reviewed here; more analytical expression used for the conduction term
detailed descriptions are provided in Refs. 5–10. A assumes not only a one-dimensional system but also
noteworthy early example of CCA can be found in time independent, steady conduction without heat
Ref. 11, which provides results of an extensive experi- generation (something that is rarely mentioned). None
mental study performed in the 1970s, involving .40 of these assumptions are true in reality, and using time
different steel alloys. For each alloy, the liquidus dependent (measured) temperatures in an analytical
temperature, solidus temperature and solid fraction expression that is strictly only valid for steady conduc-
versus temperature relationship were determined for a tion does not necessarily compensate for any errors.
variety of cooling rates. Analogous to Newtonian analysis, the latent heat and
In Newtonian analysis, metal temperature measure- solidification path can be determined by integrating the
ments are taken using a single TC in the casting cavity of difference between the measured cooling rate curve and
a small cylindrical cup. The casting sample in which the the Fourier zero curve. This solution requires iteration,
TC resides must be small (typically a few centimetres in because in Fourier analysis, both the thermal diffusivity
both diameter and height), because Newtonian analysis and the volumetric specific heat are taken as functions of
is based on the lumped capacitance method, which the solid fraction in the solidification range, and so they
assumes that the sample temperature is uniform. It is need to be determined as part of the solution. Results
further assumed that both the density and specific heat generated for aluminium alloys using both Newtonian
of the metal are constant. In Newtonian analysis, a and Fourier analyses are reviewed and compared by
smooth curve is fitted to the cooling rate data to connect Barlow and Stefanescu7 as well as by Emadi and
the cooling rate curves before and after solidification, Whiting8 and Emadi et al.10 Not surprisingly, these
producing a fictitious cooling rate curve termed the studies conclude that the latent heat values determined
Newtonian zero curve, which represents the cooling rate using Fourier analysis agree better with the values
curve if no phase change were to take place. The latent obtained from other methods, including DSC.
heat is then estimated by integrating over time the area In the present study, to determine the material
between the measured cooling rate curve and the datasets for five corrosion resistant steel and nickel
Newtonian zero curve. The fraction solid at any time based alloys, a different approach is used, which
[and hence temperature, since T(t) is known from involves a combination of full scale casting experiments
measurements] during solidification can then be eval- and casting computer simulation. Temperature measure-
uated by dividing the cumulative area between the ments are taken in the castings as they solidify and cool.
cooling rate curve and the Newtonian zero curve up to These measurements immediately yield the liquidus and
that time by the total latent heat. The approximate solidus temperatures. However, instead of constructing
nature of the results derived from this method stems a zero curve, the solidification path and latent heat are
primarily from the uncertainty associated with generat- obtained in a trial and error procedure, where measured
ing the Newtonian zero curve.7,8 However, a more and predicted temperatures and cooling rates are
systematic methodology for determining the Newtonian compared, and the material dataset is adjusted until
zero curve was developed in Ref. 9. While the New- good agreement is obtained. The initial material dataset
tonian method is often used for aluminium alloys, the is generated with thermodynamic software. The present
uniform temperature assumption makes this method less iterative method does not require any of the approxima-
practical for steel and nickel based alloys, which have tions associated with the generation of a zero curve,
substantially lower thermal conductivity than alumi- and it is made feasible by the fact that the cast-
nium alloys. In addition, the small sample size can lead ing solidification simulations (excluding filling) require
to cooling rates that are different from those encoun- ,10 min of run time, so many iterations can be
tered in production castings. performed if necessary. It is true that casting simulations
Fourier analysis6 is similar to Newtonian analysis, but can have errors associated with them, particularly in the
Fourier analysis requires less restrictive assumptions. choice of the simulation parameters for the pouring
temperature and the interfacial heat transfer coefficients databases supplied with the simulation software (see
(IHTCs) between the metal and the mould, but steps are below).
taken in the present study to eliminate the uncertainties When filling is complete, solidification and cooling of
associated with these parameters. Material datasets are the casting are simulated. This also involves solving
developed for the corrosion resistant alloys CN3MN, energy balance equations in both the metal and the
CD3MN, CD4MCuN, CW6MC and N3M. These are mould but typically neglects the effect of heat advection
all highly alloyed metals, rendering datasets created by the residual flow of the liquid metal in the mould
from thermodynamic simulation alone uncertain. The cavity. Then, the energy equation for the metal, after
castings in which TCs are embedded for this study are completion of filling, can be expressed as
plates with a thickness that is commonly encountered
in foundries casting these alloys, such that the data dfs LT
collected in these experiments are representative of r c{L
- - f ~+: k
- +T (1)
dT Lt
typical cooling rates seen in production castings.
It is worth noting that the comparisons between where T is the metal temperature, t is the time and fs is
measured and simulated temperature data, utilised in the the solid mass fraction (i.e. fs50 if the metal is locally all
present work to develop accurate material datasets, have liquid, and fs51 if it is all solid). The use of the total
value in and of themselves. While casting simulation derivative in the term dfs/dT implies that the solid
is performed routinely, detailed comparisons between fraction is assumed to be a function of temperature only.
measured and predicted temperatures in an actual The density, specific heat and thermal conductivity of
casting are scarce in the open literature. Issues such as the metal are denoted by r, - c- and k- respectively. The
the selection of simulation parameters (e.g. pouring overbar is used to emphasise that these properties are
temperature and mould/metal IHTC) are often discussed mixture quantities that depend on the amount of each
among simulation users but are not investigated system- phase present, in addition to temperature. The term Lf
atically, as in the present study. A thorough investiga- represents the latent heat of fusion per unit mass, which
tion into the effects of the simulation parameters is is assumed to be constant over the solidification tem-
necessary, since they are generally unknown and their perature range. The quantity in brackets on the left side
choice will affect the determination of alloy properties. of equation (1) has two terms: the first term accounts for
In the next section, an overview is given of the data the sensible heat, and the second accounts for the latent
that must be input into the casting simulations, which heat. This bracketed quantity is often referred to as the
includes a brief discussion of the accuracy of these data. effective specific heat, i.e.
The section entitled ‘Casting experiments and measure- dfs
ment uncertainty’ discusses the casting experiments that ceff ~c{L
- f (2)
dT
were performed for this study, and the section entitled
‘Determining characteristic temperatures from TC data’ Note that the latent heat term in equation (2) is only
describes how characteristic temperature data were non-zero while solidification is occurring, since dfs/
determined from the temperature measurements col- dT50 in fully liquid and completely solidified metal. The
lected during the casting experiments. The section negative sign in equation (2) is the result of dfs/dT being
entitled ‘Solidification path and thermophysical proper- negative during solidification; the release of latent heat
ties’ then details how the alloy material datasets were generally increases the effective specific heat. All of the
generated and modified based on the TC data. A metal alloy properties required for casting simulation,
comparison of the liquidus, solidus and latent heat as well as the solidification path, are generated by
values determined in the present study with those thermodynamic simulation software packages. The pre-
predicted by the thermodynamic simulation software is dicted values for the density, thermal conductivity and,
provided in the section entitled ‘Comparison between for the most part, specific heat are assumed to be
measured values and thermodynamic simulation values’. reasonably accurate. The focus in the present study is on
verifying and improving the accuracy of the solidifica-
tion path and the latent heat predicted by the thermo-
Casting simulation input dynamic software.
Since the present study is concerned with developing In addition to supplying material datasets for the
material datasets for casting simulation, it is useful to simulation, it is also necessary to provide initial tempera-
briefly review the governing equations being solved and tures for the metal and the mould. The initial mould
the input required. All commercial casting simulation temperature is easily determined from sand TC data, but
software packages are capable of modelling the melt the initial metal temperature (i.e. the simulation pouring
flow during filling of the mould and the heat transfer temperature) is generally not well known. The simulation
during the entire casting process. Filling is simulated by pouring temperature represents the temperature of the
solving the relevant fluid flow equations for the liquid metal stream as it enters the mould cavity. Typically,
metal as it enters the mould, which requires knowledge temperatures are taken in the furnace, and the metal
of the density and viscosity of the liquid metal. In temperature drop going from the furnace to the ladle to the
addition, energy balance equations are solved in both mould is estimated by a rule of thumb. Even if a
the metal and the mould during filling. Solidification temperature measurement is taken in the ladle immediately
during filling is typically neglected. The solution of the before pouring, the metal stream cools significantly before
energy equations requires knowledge of the densities, it reaches the mould cavity. However, by comparing
specific heats and thermal conductivities of the materials measured metal temperature readings with corresponding
involved, all as a function of temperature. In the present simulated values, it is possible to determine the correct
study, all mould properties are taken from material simulation pouring temperature. This will be explained in
a temperature measurements for both CN3MN plates; b temperature and cooling rate curves near liquidus for TC-R in plate A
3 CN3MN TC results
CN3MN. The two plates are denoted as ‘A’ and ‘B’. increase exponentially. Then, the thermal time constant
Note the excellent agreement between the two TCs in t is given by the time it takes the TC to reach 63?2%
each plate. The difference in temperatures between the (51–1/e) of the environment temperature (i.e. the liquid
two plates during cooling is the result of the difference in metal temperature). Using this method, the time
the pouring temperature for each plate, which leads to constant of the 6 mm o.d. TCs was determined from
slightly different cooling rates. Figure 3a is a represen- the temperature measurements shown in Fig. 3 to be
tative result from the casting experiments; similar TC t53 s. During cooling, the environment temperature
agreement was seen for all alloys studied. does not experience a step change but can be approxi-
The uncertainty in the temperature measurements can mated as decreasing linearly at a given cooling rate.
be quantified as follows. The maximum error of the B Performing another lumped capacitance analysis using
type TCs is stated by the manufacturer15 as 0?5% uC21. this constant cooling rate assumption, it can be shown
This translates to a maximum error of ¡7uC at 1400uC. that the maximum temperature lag of the TC is then
The relatively large size of the TC assembly requires given by DTlag5t|dT/dt|. As shown below, the maximum
careful consideration of the thermal lag. The dynamic cooling rates in the present experiments are in the order
response of the 6 mm o.d. TCs was evaluated by of 1uC s21. Hence, the maximum temperature lag during
analysing the initial, rapid temperature increase asso- cooling is estimated to be DTlag53uC. It is true that the
ciated with the liquid metal coming into contact with the time constant could be different during heating and
TC (see Fig. 3a). Assuming that the TC assembly cooling of the TC, but considering that the thermal
experiences a step change in the environment tempera- resistance between the TC junction and the metal is
ture (from room temperature to the liquid metal dominated by the contact resistance between the
temperature), and treating the TC junction as a lumped junction and the quartz tube and the conduction
capacitance, the TC temperature can be expected to resistance through the quartz tube wall, the difference
will be small.
Table 2 were determined in conjunction with simulation in these steels, two of these alloys had elemental
and will be addressed in the next section. The variation
compositions that exceed the recommended IDS ranges.
associated with each temperature given in Table 2 in-
The CD4MCuN copper content (3%Cu) exceeds the
dicates the variability of these values among the four TCs
recommended IDS range of 0–1%. The CN3MN nickel
for each alloy. For the 20 characteristic temperatures
content (25?07%Ni) exceeds the IDS range of 0–16%, and
given in Table 2, the average variation is ¡3uC, with no
the CN3MN molybdenum content (6?41%Mo) exceeds
variation being larger than ¡5uC. Thus, the measure-
the IDS range of 0–4%. The recommended ranges given
ments can be considered highly reproducible, despite
by IDS indicate ranges of alloying elements over which
being performed in a foundry setting. Note that this
the thermodynamic databases utilised by IDS were
variation is of the same magnitude as the thermal lag
developed. Extrapolation errors may occur when IDS
estimated in the previous section. Hence, the character-
ranges are exceeded. Because IDS accounts for finite rate
istic temperatures can be considered quite accurate.
solute diffusion, it is necessary to provide information
regarding the cooling rate as a function of temperature.
Solidification path and thermophysical This was performed using the data shown in Figs. 4–6.
properties On each of these cooling rate versus temperature plots,
vertical lines were drawn across the plots to create five to
Thermodynamic simulation and casting eight temperature zones, and the average cooling rate in
simulation details each zone was estimated from the plot. These cooling
Initial material datasets were generated for each alloy rate–temperature pairs were then entered into IDS for
using the compositions listed in Table 1. IDS1,2 was used each corresponding alloy simulation.
for the three steels (CN3MN, CD3MN and CD4MCuN). The initial material datasets for the nickel based alloys
It should be noted that due to the high alloying contents (CW6MC and N3M) were generated using JMatPro.3
Table 2 Measured characteristic temperatures during solidification and cooling, along with latent heats
Because JMatPro uses a modified Scheil approximation moulds was FURAN from the MAGMASOFT data-
and does not consider finite rate solute diffusion, cooling base. For CD3MN, the chromite sand around the
rate data are not considered by the program. Because the plate was modelled with the MAGMASOFT database
Scheil approximation is utilised, however, it is necessary CR_SAND. The initial sand temperatures for each alloy
to specify a solidification cutoff value. When the liquid were determined from the sand TC readings before the
fraction reaches the cutoff value, solidification is con- mould temperatures began to rise (21–22uC). The IHTC
sidered complete. The cutoff values for the nickel based between the metal and the sand mould was taken as a
alloys were adjusted until the predicted solidus tempera- constant value of 1000 W m22 K21. The legitimacy of
tures matched the measured values. Note that without the this choice will be examined shortly. Filling and
present measurements of the solidus temperature, it solidification were simulated for one plate of each alloy.
would not have been possible to determine an accurate A simulation fill time of 10 s was selected for all the
cutoff value. For CW6MC, the cutoff value found was alloys; the recorded fill times were all between 9 and
18?3%, and for N3M, the cutoff value was 13?1%. The 11 s, and previous simulation experience indicates that
probable reason for these large cutoff values is that these changing the fill time by ¡1 s effects negligible changes
datasets were generated using the general steel thermo- in the results.
dynamic database in JMatPro, which was the most Superaustenitic stainless steel CN3MN
appropriate database available to the present researchers.
For each alloy, the corresponding initial material dataset
A more appropriate thermodynamic database, specifi-
was input into the simulation using the solidification path
cally tailored for nickel based alloys, might give smaller
and latent heat predicted with the dataset as initial
cutoff values. It is also possible that the modified Scheil
estimates of those quantities. As discussed in the section
approximation is not appropriate for these alloys.
entitled ‘Casting simulation input’, the simulation pour-
The initial material datasets produced by the thermo-
ing temperature Tpour was an unknown simulation para-
dynamic simulation software packages provide tempera-
meter. Fortunately, it is possible to determine the correct
ture dependent values of the density, thermal conductivity,
simulation pouring temperature using the following time
specific heat and kinematic viscosity of each alloy. These to liquidus method. Consider CN3MN as an example.
datasets also contain a solidification path and a value for Using the initial IDS material dataset, a simulation was
the latent heat; however, the final values of these quantities performed for plate A. This initial simulation used
were determined by comparing measured and simulated Tpour51540uC as a first guess of the pouring temperature
data, as explained below. In addition, the IDS datasets for (the furnace temperature recorded for this alloy was
the two duplex steels (CD3MN and CD4MCuN) also 1598uC). The temperature and cooling rate curves
predict the ferrite to austenite transformation. For both resulting from the plate’s right virtual TC (TC-R, as
alloys, the predicted ferrite to austenite transformation shown in Fig. 1c) in this simulation are compared with
start temperature was in approximate agreement with the the measured values from plate A (TC-R in Fig. 9a).
measured values listed in Table 2. The final microstructure Note that the IDS solidification path used in this
predicted for both duplex steels was ,50% ferrite–50% simulation has a liquidus temperature of 1uC less than
austenite, as expected. No solid state transformation was the measured value and a solidus temperature of 2uC less
predicted for CN3MN, which solidifies as austenite and than the measurement (see Table 3 below); these small
remains austenite down to room temperature. differences are not visible in the temperature scale used in
The liquidus and solidus values predicted by the Fig. 9. Both the virtual and real TCs begin to heat at the
thermodynamic software packages typically differed by same time, when metal first comes into contact with them.
several degrees from the measured values given in Table 2. The virtual TC immediately jumps to the temperature of
Because of these discrepancies, small adjustments were the surrounding metal, but the real TC has some thermal
made to some of the material datasets for density, thermal lag. For Tpour51540uC, it is evident in Fig. 9a that the
conductivity, specific heat and kinematic viscosity of each virtual TC reaches the measured liquidus temperature
alloy. This was necessary because particularly at liquidus, (indicated by the upper dashed line) later than the
sudden changes occur in some of these properties (i.e. if a measured TC (by ,15 s). This indicates that the
property is displayed as a function of temperature, such a simulation superheat is too high, and thus, Tpour is lower
change would appear as a ‘kink’ in the property curve). than this first guess of 1540uC.
Since the measured liquidus and solidus values were used With this information, additional simulations were
to generate the solidification paths for these alloys (see run with the same material dataset but with different
below), consistency required that these kinks in the values of Tpour. After several iterations, Tpour51502uC
property curves occur at the measured temperatures rather was selected. The resulting temperature and cooling rate
than at their simulated counterparts; therefore, the kinks curves for TC-R in this simulation are shown in Fig. 9b.
were shifted from the predicted temperatures to the With this choice of Tpour, the time to reach liquidus in the
measured values. simulation now agrees with the measurement, indicating
The casting experiments were simulated using the that the correct simulation pouring temperature has been
general purpose casting simulation software package determined. Note that this pouring temperature will
MAGMASOFT.16 The rigging shown in Fig. 1 was used continue to give the correct time to liquidus as changes
for the simulations. For each alloy, virtual TCs were are made to the latent heat and solidification path,
placed in locations corresponding to the actual TC because the time to liquidus is primarily affected by
locations in the casting experiments. The numerical grid properties above the liquidus temperature.
used Dx5Dy54 mm and Dz53?2 mm, resulting in eight While the time to liquidus is now the same for the
computational cells through the plate thickness, and a simulation and measurement in Fig. 9b, there is still a
total of ,214 000 cells in the metal. The mould material large discrepancy between the measured and simulated
used to model the phenolic urethane no bake sand times to reach the solidus temperature (indicated by the
a Tpour51540uC, IDS solidification path and latent heat (L5253 kJ kg21); b Tpour51502uC, IDS solidification path and
latent heat (L5253 kJ kg21); c Tpour51502uC, IDS solidification path, L5200 kJ kg21; d Tpour51502uC, modified solidifica-
tion path, L5180 kJ kg21
9 Simulated and measured temperatures and cooling rates for CN3MN simulations using different initial metal tempera-
tures and material properties
Table 3 Comparison between solidification ranges and latent heats determined experimentally with corresponding values
from thermodynamic simulation software
Metal type Alloy Value Values determined from experiments IDS* JMatPro{
10 CN3MN solidification path generated by IDS compared 11 Measured CN3MN temperatures compared with simu-
lated values computed with different mould/metal IHTCs
with modified path determined through analysis of TC
data
column of Table 2. An uncertainty estimate of
¡10 kJ kg21 is included with this value. This uncertainty
lower dashed line). This large discrepancy exists regard- arises primarily due to variations seen when simulating
less of the choice for the simulation pouring temperature the other plate of the same alloy (not shown here). A
(see Fig. 9a and b). The simulated time to solidus is discussion of the final latent heat value, together with a
much longer than the measured time, indicating that comparison to predicted values, can be found in the
solidification is proceeding too slowly in the simulation. section entitled ‘Comparison between measured values
This is largely because the value of latent heat given by and thermodynamic simulation values’.
IDS for CN3MN (Lf5253 kJ kg21) is too large. To It could be fairly stated that the dataset used to
illustrate how changing the latent heat changes the generate the results in Fig. 9c is already acceptable,
solidification time, Fig. 9c shows the results of a without modification of the solidification path. The
simulation run with Tpour51502uC, but with the latent agreement between measured and simulated tempera-
heat changed to Lf5200 kJ kg21. This figure demon- tures below solidus is essentially the same as the results
strates that changing the latent heat clearly changes the with the modified solidification path (Fig. 9d), and the
time the simulation takes to reach solidus. Using temperature differences seen in the solidification region
Lf5200 kJ kg21 with the initial IDS dataset, the time in Fig. 9c are not overly large. Thus, the overall
to solidus in the simulation is now the same as the temperature prediction with the original solidification
measured time. path would be reasonable. The motivation behind
Although the simulation times to liquidus and solidus modifying the solidification path lies in casting defect
in Fig. 9c are now in agreement with the measured prediction. Many casting defects (solidification shrink-
values, the simulated and measured temperatures and age, hot tears, etc.) occur near the end of solidification.
cooling rates do not agree very well in the solidification Accurate prediction of these defects requires an accurate
range. To bring the temperatures into better agreement representation of the solidification path in this region.
during solidification, it is necessary to alter the The IDS solidification path is compared with the
solidification path. This involves a substantial amount modified path in Fig. 10. The modified path forms solid
of iteration: adjusting the solidification path, then faster near liquidus and slower near solidus than the IDS
running a simulation and comparing the new simulation path. The horizontal dashed line near the top of this plot
results to the measurements and using this information indicates the point where the metal is 95% solidified. The
to make further adjustments to the solidification path. IDS solidification path reaches 95% solid 22uC above
The results from the simulation with the final modified solidus, whereas the modified path reaches 95% solid
solidification path (see Fig. 10) are shown in Fig. 9d. 33uC above solidus. This significantly larger temperature
Now, the temperatures and cooling rates during difference with the modified path provides more
solidification are in very good agreement. Note that opportunity for defects to form. In other words, using
the latent heat listed in Fig. 9d has changed from the IDS solidification path may lead to an under-
200 kJ kg21 (in Fig. 9c) to 180 kJ kg21. This change in prediction of defects compared with the modified path.
the latent heat required to get agreement in the time to Comparing Fig. 9a and d clearly illustrates that this
solidus is the result of changing the solidification path. iterative procedure, wherein modifications to the simula-
The physical explanation for the change in latent heat as tion pouring temperature and to the original dataset are
the solidification path changes can be understood by made by comparing measured and simulated TC results
considering equation (2): changing the solidification and then adjusting the simulated dataset until the results
path changes dfs/dT, so in order to obtain the same agree, is very effective (if somewhat tedious). To summar-
effective specific heat, the value of the latent heat must ise, the present procedure involves the following steps:
change as well. The final latent heat value determined (i) beginning with the initial material dataset and a
for CN3MN (180 kJ kg21) is listed in the rightmost guess for the simulation pouring temperature,
a sand TC 2?0 in. above plate surface; b sand TC 1?1 in. above plate surface
13 Measured sand temperatures for CN3MN plate A mould compared with simulated values computed with different
IHTCs
15 Comparison of simulated and measured CD3MN temperatures and cooling rates for plate B, TC-R, using a initial IDS
dataset and b final modified dataset (Tpour51504uC)
16 Comparison of simulated and measured CD4MCuN temperatures and cooling rates for plate A, TC-R, using a initial
IDS dataset and b final modified dataset (Tpour51508uC)
Excellent agreement between measurement and simula- accounts for the latent heat related to this transforma-
tion is seen after the dataset is modified, as shown tion; however, although IDS simulates the ferrite to
in Fig. 15b. In contrast to CD3MN, Fig. 16a shows austenite transformation that occurs in these alloys in
that the original IDS dataset simulation results for terms of phase fractions, it does not account for the
CD4MCuN are in poor agreement with the measured associated latent heat release. This latent heat release
results. The simulation cools too quickly during can be added manually to the thermophysical datasets
solidification and then too slowly in subsequent cooling by modifying the specific heat curve. The modified
below solidus. The reason that the original dataset for specific heat curves for the duplex steels are shown in
CD3MN gives somewhat reasonable results, while the Fig. 17 along with the corresponding original IDS
original dataset for CD4MCuN gives very poor results, specific heat curves. The modified specific heat curves
is the large copper content in CD4MCuN. The 3%Cu each have a spike, whose peak occurs at the ferrite to
addition exceeds the allowable IDS range for this austenite transition start temperature listed in Table 2.
alloying element, which is 0–1%. In this instance, the The height of the spikes, and the width of their bases,
extrapolation that IDS performs with the large copper was determined through the same type of procedure that
content creates an unrealistic liquidus value and has been discussed throughout this paper, changing the
solidification path. Modification of this dataset, how- shape until the simulated cooling rate curves matched
ever, to correct the solidification range and latent heat, the measured values. The spikes seen in the IDS specific
produces excellent agreement between measurement and heat curves in Fig. 17 are the result of the IDS austenite
simulation, as seen in Fig. 16b. decomposition model. Even though IDS correctly
For these duplex steels, additional dataset modifica- predicts the phase fractions of ferrite and austenite
tion was required to produce the ‘kinks’ seen in the during the ferrite to austenite transformation, the spike
cooling rate curves after solidification is complete, which that corresponds to austenite decomposition, peaking at
correspond to the latent heat release during the ferrite to ,600uC, still appears in the specific heat curves. This
austenite transformation. IDS contains a model that spike was removed in the modified curves since austenite
simulates austenite decomposition below 1000uC and decomposition does not occur. The slope of the modified
a CD3MN; b CD4MCuN
17 Comparison between original IDS and modified specific heat curves for duplex stainless steels
18 Comparison of simulated and measured CW6MC temperatures and cooling rates for plate B, TC-R, using a initial
JMatPro dataset and b final modified dataset (Tpour51486uC)
19 Comparison of simulated and measured N3M temperatures and cooling rates for plate B, TC-R, using a initial
JMatPro dataset and b final modified dataset (Tpour51528uC)
curves after the ferrite to austenite spike was chosen to end of solidification was determined again through an
match the slope of the IDS curves just below solidus. iterative manner. Figures 15b and 16b show that the
The decrease in the modified specific heat curves modified specific heat curves give good agreement
compared with the IDS curves that begins near the between measurement and simulation below solidus.
Although it is not shown in Figs. 15b and 16b, reason-
able agreement between simulation and measurement is
seen down to ,600uC (where temperature measurement
ended), indicating that removal of the peak in the IDS
curves is valid.
21 a N3M results from Fig. 19, shown over longer time span to include solid state transformation and b N3M original
and modified specific heat curves
formation at ,450 s. Once the CW6MC dataset is Comparison between measured values
modified, however, Fig. 18b shows that both simulated and thermodynamic simulation values
temperature and cooling rate curves give excellent agree-
ment with the measurements. In order to capture the large In an effort to lend further credence to the values provided
spike (local minimum) in the cooling rate curve associated in Table 2, Table 3 compares the measured liquidus,
with the tertiary phase formation, it was necessary to put a solidus and latent heat values with the corresponding
significant kink in the CW6MC solidification path. The values predicted by IDS and JMatPro. The IDS results
final solidification path for CW6MC is shown in Fig. 20 were generated using the stainless steel option in the
along with the final solidification paths determined for the software, with cooling rate profiles determined from the
other alloys. experiments. Recall that the CD4MCuN copper content
(3%Cu) exceeds the IDS range of 0–1%. In addition, the
The original JMatPro dataset simulation results for CN3MN nickel content (25?07%Ni) exceeds the IDS
N3M, shown in Fig. 19a, do not agree well with the range of 0–16%, and the CN3MN molybdenum content
measured temperatures or cooling rates. The simulated (6?41%Mo) exceeds the IDS range of 0–4%. IDS cannot be
casting cools too fast in the solidification region. The used for the two nickel based alloys. The JMatPro results
secondary solid phase is again only very approximately were generated assuming a default solidification cutoff
modelled by an inflection in the cooling rate curve, and the value of 1%. The stainless steels (CN3MN, CD3MN
tertiary solid phase is completely missed. The modified and CD4MCuN) were modelled with the JMatPro
dataset simulation results, shown in Fig. 19b, again show stainless steel database, and the nickel based alloys
excellent agreement with the measured values. (CW6MC and N3M) were modelled with the general steel
Finally, the N3M simulation results shown in Fig. 19b database.
are repeated in Fig. 21a, showing a larger temperature First, compare the measured and simulated liquidus
range and time scale. As with the duplex steels, an values. IDS gives liquidus temperatures very close to the
additional modification had to be made to the specific measured values for CN3MN (different by 1uC) and
heat curve for N3M in order to account for a solid state CD3MN (different by 2uC), which instils confidence in
transformation that can be seen by the kink in the the measured values for these steels. There is a large
measured cooling rate curve for N3M at ,830uC in discrepancy between the IDS value and the measured
Fig. 21a. This transformation (whose value is included in liquidus value for CD4MCuN (different by 14uC), which
Table 2) is not shown in Fig. 8 because the temperature is due to extrapolation errors in IDS resulting from the
range in Figs. 4–8 (1000–1500uC) was selected to high- large copper content of this alloy. The reason that
light the solidification ranges. The N3M solid state extrapolation errors are assumed for this alloy can be
transformation is the only transformation that is not seen by comparing the compositions of CD3MN and
shown in Figs. 4–8. To model this transformation, the CD4MCuN in Table 1: the compositions are similar,
N3M specific heat curve was modified below solidus, as except for the 3% copper content in CD4MCuN. Note
shown in Fig. 21b. The modification to the original the relatively large difference between the IDS and
JMatPro curve was again determined iteratively. Note JMatPro predictions for the liquidus values of steels: the
that the JMatPro curve has a peak similar in shape to the two predictions differ by 14uC for CN3MN, by 11uC for
modified peak but occurring at a much lower tempera- CD3MN and by 8uC for CD4MCuN. For the nickel
ture. It is possible that the JMatPro peak accounts for the based alloys, reasonable agreement is seen between the
same transformation the modified peak is capturing, just JMatPro liquidus predictions and the measured values:
over a temperature range that is too low. With this the measured and predicted liquidus values differ by 7uC
modified specific heat curve, Fig. 21a shows that the for CW6MC and by only 1uC for N3M.
simulated temperature and cooling rate curves are in As with the liquidus temperatures, the measured
excellent agreement with the measurements. solidus temperatures and the IDS predictions of these
temperatures are in good agreement for CN3MN were necessary. The modifications were made utilising
(different by 2uC) and for CD3MN (different by 7uC). temperature measurements taken in each alloy during
The difference is very large for CD4MCuN (different by casting of 1 in. (2?54 cm) thick plates. This thickness,
66uC), but again, this is presumably due to extrapolation which commonly occurs in castings produced with these
errors due to the large copper content. The JMatPro alloys, was selected because the solidification path is a
solidus predictions are too low compared with the function of cooling rate, and it was deemed important to
measurements for all alloys, but this is meaningless; it is measure the temperatures in a setting that provided
due to the small solidification cutoff value of 1% that cooling rates seen in foundry production of these alloys.
was used to generate the results for all alloys in Table 3. Each initial material dataset was then modified using an
Next, compare the measured and predicted values iterative method, which utilises comparison between
of latent heat. The latent heat predictions by IDS measured temperature and cooling rate data with corre-
and JMatPro are very weak functions of the liquidus sponding simulated values to direct changes in the dataset,
and solidus temperatures, so the validity of the latent until satisfactory agreement between simulated and mea-
heat prediction is not affected by whether or not the sured temperatures and cooling rates was reached. Pri-
freezing range was reasonably predicted for an alloy. marily, this involved changing the predicted latent heat
Notice that the measured values for CD3MN, and the solidification path of all the alloys. It was also
CD4MCuN and N3M are all in reasonable agreement necessary to modify the effective specific heat curves for
with the predicted values. For CD3MN, the measured CD3MN, CD4MCuN and N3M in order to correctly
value (162 kJ kg21) lies between the two predicted account for solid state transformations in these alloys.
values (178 and 154 kJ kg21). For CD4MCuN, the Uncertainties in the simulation due to unknown pouring
measured value (162 kJ kg21) is noticeably below the temperatures and IHTCs were effectively eliminated
IDS value (187 kJ kg21), but close to the JMatPro value through parametric studies and comparisons with mea-
(167 kJ kg21). In addition for N3M, the measured and sured mould temperatures. The final material datasets
predicted values are very close, only differing by developed in this study produce very good agreement
2 kJ kg21. The discrepancy for CW6MC between the between simulated and measured temperatures and
measured value (179 kJ kg21) and the JMatPro predic- cooling curves. Although the present iterative method
tion (237 kJ kg21) can be explained by the fact that to determine the solid fraction–temperature relation and
JMatPro does not predict the formation of the tertiary latent heat is somewhat tedious, it is believed to be more
phase that forms toward the end of solidification, which accurate than traditional Newtonian and Fourier CCA
causes a significant drop in the cooling rate curve in methods that involve small cup castings and the construc-
Fig. 18. Notice that the results in Fig. 18a, which were tion of a zero curve.
generated using the original JMatPro solidification
path and L5237 kJ kg21, show poor agreement in the Acknowledgements
cooling rate curves near the end of solidification
(although the time to solidus is reasonably predicted), This work was performed with the financial support of
while the results in Fig. 18b, which were generated using the Materials Technology Institute (MTI). However, any
the modified solidification path shown in Fig. 20 with opinions, findings, conclusions or recommendations
L5179 kJ kg21, correctly predict the sharp decrease in expressed herein are those of the authors and do not
cooling rate due to this tertiary phase. Finally, note the necessarily reflect the views of MTI. We are indebted to
significant discrepancy between the measured and M. Blair and R. Monroe (of the Steel Founders’ Society
predicted latent heat values for CN3MN. The IDS of America) and to G. Hodge (of MTI) for their input and
value of 252 kJ kg21 is too large; the error presumably assistance in the organisation of this project. Most
results from the high nickel content of this alloy importantly, we thank the employees at Stainless
significantly exceeding the IDS range. This conclusion Foundry & Engineering, Inc., for performing the plate
is supported by the JMatPro prediction (217 kJ kg21), casting experiments. This work could not have been
which is much lower than the IDS prediction. The accomplished without their shared efforts. In particular,
JMatPro prediction is still higher than the measured we are very grateful to R. Bird and J. Wagner of Stainless
value of 180 kJ kg21, but this predicted value may also Foundry & Engineering, Inc., for their efforts in pouring
be errantly large. Because reasonable agreement is seen the castings.
between the measured and predicted latent heat values
in CD3MN, CD4MCuN and N3M, and the differences References
in the values for CW6MC are caused by the failure of
1. J. Miettinen: Metall. Trans. B, 1997, 28B, 281–297.
the software to predict a significant phase, it seems 2. J. Miettinen and S. Louhenkilpi: Metall. Trans. B, 1994, 25B, 909–
unlikely that the measured value for CN3MN is signi- 916.
ficantly errant in only this one alloy. 3. JMatPro v4?0, Sente Software Ltd, Surrey Technology Centre,
Surrey, UK.
4. W. J. Boettinger, U. R. Kattner, K. W. Moon and J. H. Perepezko:
Conclusions ‘DTA and heat-flux DSC measurements of alloy melting and
freezing’, ‘NIST recommended practice guide’, NIST special
In the present study, alloy material databases, necessary to publication 960-15, Washington, DC, USA, 2006.
perform casting simulations, were developed for five 5. D. M. Stefanescu, G. Upadhya and D. Bandyopadhyay: Metall.
commonly used corrosion resistant alloys: superaustenitic Trans. A, 1990, 21A, 997–1005.
stainless steel CN3MN, duplex stainless steels CD3MN 6. E. Fras, W. Kapturkiewicz, A. Burbielko and H. F. Lopez: AFS
and CD4MCuN and nickel based alloys CW6MC and Trans., 1993, 101, 505–511.
7. J. O. Barlow and D. M. Stefanescu: AFS Trans., 1997, 105, 349–354.
N3M. Initial material datasets were generated using 8. D. Emadi and L. V. Whiting: AFS Trans., 2002, 110, 285–296.
thermodynamic simulation software. Owing to limitations 9. W. T. Kierkus and J. H. Sokolowski: AFS Trans., 1999, 107, 161–
of the software, however, modifications to these datasets 167.
10. D. Emadi, L. V. Whiting, S. Nafisi and R. Ghomashchi: J. Therm. 13. DASYLab v8?0, Adept Scientific, Amor Way, Letchworth,
Anal. Calorim., 2005, 81, 235–242. Hertfordshire, UK.
11. ‘A guide to the solidification of steels’, Jernkontoret, Stockholm, 14. K. D. Carlson, S. Ou and C. Beckermann: Metall. Mater. Trans. B,
Sweden, 1977. 2005, 36B, 843–856.
12. Personal Daq/3005, Measurement Computing Corporation, 15. Nanmac Corp., Framingham, MA, USA.
Norton, MA, USA. 16. MAGMASOFT v4?6, MAGMA GmbH, Aachen, Germany.