TIME- AND MONITORING RELAYS

W TIME- AND MONITORING RELAYS

Page
474
TIME- AND MONITORING RELAYS

W MEASURING AND MONITORING RELAYS

W SERIES 5

OPERATION DISPLAY

LARGE TIME RANGE 50 ms – 100 h

MANY FUNCTIONS

45 mm CAP DIMENSION

MULTI-VOLTAGE 12 or 24 V~/DC – 240 V~/DC

Page

W SERIES 6 475

INDUSTRIAL DESIGN

WIDTH 22.5 mm

MANY FUNCTIONS, E.G.:

• Monitoring of phase sequence and phase failure

• Detection of neutral wire break

• Windows function

• 16.6 – 400 Hz

• Thermal resistor relay

• Delayed contacts possible

• Time range of timer relay: 1 s to 30 days


TIME RELAYS

w TIME RELAY ZR5E0011

w SCHRACK-INFO

Wide input voltage range


1 change over contact
Width 17,5 mm
Installation design

w TECHNICAL DATA

1. Functions 6. Output circuit


The function has to be set before connecting the relay to the 1 potential free change over contact
supply voltage. Rated voltage: 250 V AC
E ON delay Switching capacity: 2000 VA (8 A / 250V)
Fusing: 8 A fast acting
2. Time ranges Mechanical life: 20 x 106 operations
Time range Adjustment range Electrical life: 2 x 105 operations
1s 50 ms 1s at 1000 VA resistive load
10 s 500 ms 10 s Switching frequency: max. 60/min at 100 VA resistive load
1 min 3s 1 min max. 6/min at 1000 VA resistive load
10 min 30 s 10 min (according to IEC 947-5-1)
1h 3 min 1h Overvoltage category: III. (according to IEC 60664-1)
10 h 30 min 10 h Rated surge voltage: 4 kV
100 h 5h 100 h 7. Control input
Input not potential free: Terminals A1-B1
3. Indicators Loadable: yes
Green LED U/t ON: indication of supply voltage Max. line length: 10m
Green LED U/t flashes: indication of time period Trigger level (sensitivity):
automatic adaption to supply
Yellow LED R ON/OFF: indication of relay outputs voltage
Page Min. control pulse length: DC 50 ms / AC 100 ms
4. Mechanical design
476 Self-extinguishing plastic housing, IP rating IP40 8. Accuracy
Base accuracy: ±1% of maximum scale value
Mounted on DIN-rail TS 35 according to EN 50022
Mounting position: any Adjustment accuracy: <5% of maximum scale value
Shockproof terminal connection according to VBG 4 (PZ1 Repetition accuracy: <0.5% or ±5 ms
required), IP rating IP20 Voltage influence: -
Tightening torque: max. 1 Nm Temperature influence: ⱕ0.01% / °C
Terminal capacity: 9. Ambient conditions
1 x 0.5 to 2.5 mm² with/without multicore cable end Ambient temperature: -25 to +55 °C
1 x 4 mm² without multicore cable end (according to IEC 68-1)
2 x 0.5 to 1.5 mm² with/without multicore cable end Storage temperature: -25 to +70 °C
2 x 2.5 mm² flexible without multicore cable end Transport temperature: -25 to +70 °C
5. Input circuit Relative humidity: 15% to 85%
Supply voltage: Terminals A1(+)-A2 (according to IEC 721-3-3 class 3K3)
Pollution degree: 2, if built in 3
Types ZR5..24-240 V AC/DC: 24 to 240 V AC/DC (according to IEC 664-1)
Tolerance: 24 V-15% to 240 V+10% Vibration resistance: 10 to 55 Hz 0.35 mm
Rated consumption: 4 VA (1.5 W) (according to IEC 68-2-6)
Rated frequency: AC 48 to 63 Hz Shock resistance: 15 g 11 ms
Duty cycle: 100% (according to IEC 68-2-27)
Reset time: 100 ms
Residual ripple for DC: 10%
Drop-out voltage: >30% of minimum rated supply
voltage
Overvoltage category: III (according to IEC 60664-1)
Rated surge voltage: 4 kV
TIME RELAYS

w FUNCTIONS w CONNECTIONS
ON delay (E) without control input
When the supply voltage U is applied, the set interval t begins (green LED
U/t flashes). After the interval t has expired (green LED U/t illuminated)
the output relay R switches into on-position (yellow LED illuminated). This
status remains until the supply voltage is interrupted. If the supply voltage is
interrupted before the expiry of the interval t, the interval already expired
is erased and is restarted when the supply voltage is next applied.

w WEIGHT w DIMENSIONS

Single packing: 72 g
Package 10 pcs: 670 g per Package

W ARTICLE NUMBER
DESCRIPTION ORDER NO.
Single function timerelay E (ON delay),
24-240VAC, 1 change over, 8A/250V ZR5E0011

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Single function time relay E (ON delay), 24-240VAC, 1 change over, 8A/250V 9004840459029 ZR5E0011

Page
I KNOW WHERE TO FIND IT! 477

THE SCHRACK TECHNIK WEB SHOP WITH NAVIGATOR


WWW.SCHRACK.COM

• Finding product information made easy


• Buying products around the clock
• Quick access customer service

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w TIME RELAY ZR5R0011

w SCHRACK-INFO

Wide input voltage range


1 change over contact
Width 17,5 mm
Installation design

w TECHNICAL DATA

1. Functions 6. Output circuit


The function has to be set before connecting the relay to the 1 potential free change over contact
supply voltage. Rated voltage: 250 V AC
R OFF delay Switching capacity: 2000 VA (8 A / 250V)
Fusing: 8 A fast acting
2. Time ranges Mechanical life: 20 x 106 operations
Time range Adjustment range Electrical life: 2 x 105 operations
1s 50 ms 1s at 1000 VA resistive load
10 s 500 ms 10 s Switching frequency: max. 60/min at 100 VA resistive load
1 min 3s 1 min max. 6/min at 1000 VA resistive load
10 min 30 s 10 min (according to IEC 947-5-1)
1h 3 min 1h Overvoltage category: III. (according to IEC 60664-1)
10 h 30 min 10 h Rated surge voltage: 4 kV
100 h 5h 100 h 7. Control input
Input not potential free: Terminals A1-B1
3. Indicators Loadable: yes
Green LED U/t ON: indication of supply voltage Max. line length: 10m
Green LED U/t flashes: indication of time period Trigger level (sensitivity):
automatic adaption to supply
Yellow LED R ON/OFF: indication of relay outputs voltage
Page Min. control pulse length: DC 50 ms / AC 100 ms
4. Mechanical design
478 Self-extinguishing plastic housing, IP rating IP40 8. Accuracy
Base accuracy: ±1% of maximum scale value
Mounted on DIN-rail TS 35 according to EN 50022
Mounting position: any Adjustment accuracy: <5% of maximum scale value
Shockproof terminal connection according to VBG 4 (PZ1 Repetition accuracy: <0.5% or ±5 ms
required), IP rating IP20 Voltage influence: -
Tightening torque: max. 1 Nm Temperature influence: ⱕ0.01% / °C
Terminal capacity: 9. Ambient conditions
1 x 0.5 to 2.5 mm² with/without multicore cable end Ambient temperature: -25 to +55 °C
1 x 4 mm² without multicore cable end (according to IEC 68-1)
2 x 0.5 to 1.5 mm² with/without multicore cable end Storage temperature: -25 to +70 °C
2 x 2.5 mm² flexible without multicore cable end Transport temperature: -25 to +70 °C
5. Input circuit Relative humidity: 15% to 85%
Supply voltage: Terminals A1(+)-A2 (according to IEC 721-3-3 class 3K3)
Pollution degree: 2, if built in 3
Types ZR5..24-240 V AC/DC: 24 to 240 V AC/DC (according to IEC 664-1)
Tolerance: 24 V-15% to 240 V+10% Vibration resistance: 10 to 55 Hz 0.35 mm
Rated consumption: 4 VA (1.5 W) (according to IEC 68-2-6)
Rated frequency: AC 48 to 63 Hz Shock resistance: 15 g 11 ms
Duty cycle: 100% (according to IEC 68-2-27)
Reset time: 100 ms
Residual ripple for DC: 10%
Drop-out voltage: >30% of minimum rated supply
voltage
Overvoltage category: III (according to IEC 60664-1)
Rated surge voltage: 4 kV
TIME RELAYS

w FUNCTIONS w CONNECTIONS
OFF delay (R) with control input
The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). When the control contact S is closed, the output
relay R switches into on-position (yellow LED illuminated). If the
control contact is opened, the set interval t begins (green LED
flashes). After the interval t has expired (green LED U/t illuminated) the
output relay switches into off-position (yellow LED not illuminated). If
the control contact is closed again before the interval t has expired,
the interval already expired is erased and is restarted.

w DIMENSIONS
w WEIGHT

Single packing: 72 g
Package 10 pcs: 670 g per Package

W ARTICLE NUMBER
DESCRIPTION ORDER NO.
Single function timerelay R (OFF delay),
24-240VAC, 1 change over, 8A/250V ZR5R0011

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Single function time relay R (OFF delay), 24-240VAC, 1 change over, 8A/250V 9004840459050 ZR5R0011

Page

I KNOW WHERE TO FIND IT! 479

WITH THE SCHRACK TECHNIK LiVE-PHONE APP

• Access technical product information at any time and from everywhere


• See availability and price immediately
• Order desired products easily

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w TIME RELAY ZR5ER011

w SCHRACK-INFO

2 functions
7 time ranges
Wide input voltage range
1 change over contact
Width 17,5 mm
Installation design

w TECHNICAL DATA

1. Functions 6. Output circuit


The function has to be set before connecting the relay to the 1 potential free change over contact
supply voltage. Rated voltage: 250 V AC
E ON delay Switching capacity: 2000 VA (8 A / 250V)
R OFF delay Fusing: 8 A fast acting
Mechanical life: 20 x 106 operations
2. Time ranges Electrical life: 2 x 105 operations
Time range Adjustment range at 1000 VA resistive load
1s 50 ms 1s Switching frequency: max. 60/min at 100 VA resistive load
10 s 500 ms 10 s max. 6/min at 1000 VA resistive load
1 min 3s 1 min (according to IEC 947-5-1)
10 min 30 s 10 min Overvoltage category: III. (according to IEC 60664-1)
1h 3 min 1h Rated surge voltage: 4 kV
10 h 30 min 10 h
100 h 5h 100 h 7. Control input
Input not potential free: Terminals A1-B1
Loadable: yes
3. Indicators Max. line length: 10m
Green LED U/t ON: indication of supply voltage Trigger level (sensitivity):
automatic adaption to supply
Green LED U/t flashes: indication of time period voltage
Yellow LED R ON/OFF: indication of relay outputs Min. control pulse length: DC 50 ms / AC 100 ms
Page
4. Mechanical design
480 Self-extinguishing plastic housing, IP rating IP40
8. Accuracy
Base accuracy: ±1% of maximum scale value
Mounted on DIN-rail TS 35 according to EN 50022 Adjustment accuracy: <5% of maximum scale value
Mounting position: any Repetition accuracy: <0.5% or ±5 ms
Shockproof terminal connection according to VBG 4 (PZ1 Voltage influence: -
required), IP rating IP20 Temperature influence: ⱕ0.01% / °C
Tightening torque: max. 1 Nm
Terminal capacity: 9. Ambient conditions
1 x 0.5 to 2.5 mm² with/without multicore cable end Ambient temperature: -25 to +55 °C
1 x 4 mm² without multicore cable end (according to IEC 68-1)
2 x 0.5 to 1.5 mm² with/without multicore cable end Storage temperature: -25 to +70 °C
2 x 2.5 mm² flexible without multicore cable end Transport temperature: -25 to +70 °C
Relative humidity: 15% to 85%
5. Input circuit (according to IEC 721-3-3 class 3K3)
Supply voltage: Terminals %A1(+)-A2 % Pollution degree: 2, if built in 3
Types ZR5..24-240 V AC/DC: 24 to 240 V AC/DC (according to IEC 664-1)
Tolerance: 24 V-15% to 240 V+10% Vibration resistance: 10 to 55 Hz 0.35 mm
Rated consumption: 4 VA (1.5 W) (according to IEC 68-2-6)
Rated frequency: AC 48 to 63 Hz Shock resistance: 15 g 11 ms
Duty cycle: 100% (according to IEC 68-2-27)
Reset time: 100 ms
Residual ripple for DC: 10%
Drop-out voltage: >30% of minimum rated supply
voltage
Overvoltage category: III (according to IEC 60664-1)
Rated surge voltage: 4 kV
TIME RELAYS

w FUNCTIONS w CONNECTIONS
ON delay (E) with control input without control input
When the supply voltage U is applied, the set interval t begins (green LED
U/t flashes). After the interval t has expired (green LED U/t illuminated)
the output relay R switches into on-position (yellow LED illuminated). This
status remains until the supply voltage is interrupted. If the supply voltage is
interrupted before the expiry of the interval t, the interval already expired
is erased and is restarted when the supply voltage is next applied.

OFF delay (R) w DIMENSIONS


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). When the control contact S is closed, the output
relay R switches into on-position (yellow LED illuminated). If the
control contact is opened, the set interval t begins (green LED
flashes). After the interval t has expired (green LED U/t illuminated) the
output relay switches into off-position (yellow LED not illuminated). If
the control contact is closed again before the interval t has expired,
the interval already expired is erased and is restarted.

w WEIGHT W ARTICLE NUMBER

Single packing: 72 g DESCRIPTION ORDER NO.


Package 10 pcs: 670 g per Package Double function timerelay E (ON delay) + R (OFF delay),
24-240VAC, 1 change over, 8A/250V ZR5ER011

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Double function time relay E (ON delay) + R (OFF delay), 24-240VAC, 1 change over, 8A/250V 9004840459036 ZR5ER011

Page
481

I KNOW WHERE TO FIND IT!

THE SCHRACK TECHNIK WEB SHOP WITH NAVIGATOR


WWW.SCHRACK.COM

• Finding product information made easy


• Buying products around the clock
• Quick access customer service

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w MULTIFUNCTION TIME RELAY ZR5MF011

w SCHRACK-INFO
• Timers multifunctional
• Up to 7 functions
• 7 time ranges
• Wide input voltage range
• 1 change over contact
• Width 17,5 mm
• Installation design

w TECHNICAL DATA

1. Functions Overvoltage category: III (according to IEC 60664-1)


The functions has to be set before connecting the relay to Rated surge voltage: 4kV
the supply voltage.
6. Output circuit
E ON delay
2 potential free change over contacts
1
R OFF delay
Rated voltage: 250 V AC
Ws Single shot leading edge with control input
Switching capacity: 2000 VA (8 A / 250 V)
Wa Single shot trailing edge with control input
Fusing: 8 A fast acting
Es ON delay with control input
Mechanical life: 20 x 106 operations
Wu Single shot leading edge voltage controlled
Electrical life: 2 x 105 operations
Bp Flasher pause first
at 1000 VA resistive load
2. Time ranges Switching frequency: max. 60/min at 100VA resistive load
Time range Adjustment range max. 6/min at 1000VA resistive load
1s 50 ms 1s (according to IEC 947-5-1)
10 s 500 ms 10 s Overvoltage category: III. (according to IEC 60664-1)
1 min 3s 1 min Rated surge voltage: 4kV
10 min 30 s 10 min
7. Control input
1h 3 min 1h
Input not potential free: terminals A1-B1
10 h 30 min 10 h
Loadable: yes
100 h 5h 100 h
Max. line length: 10m
Page 3. Indicators Trigger level (sensitivity): automatic adaption to supply voltage
482 Green LED U/t ON: indication of supply voltage Min. control pulse length: DC 50 ms / AC 100 ms
Green LED U/t flashes: indication of time period
8. Accuracy
Yellow LED R ON/OFF: indication of relay output
Base accuracy: ±1% of maximum scale value
4. Mechanical design Adjustment accuracy: <5% of maximum scale value
Self-extinguishing plastic housing, IP rating IP40 Repetition accuracy: <0.5% or ±5 ms
Mounted on DIN-rail TS 35 according to EN 50022 Voltage influence: -
Mounting position: any Temperature influence: ⱕ0.01% / °C
Shockproof terminal connection according to VBG 4 (PZ1 required),
9. Ambient conditions
IP rating IP20
Ambient temperature: -25 to +55 °C
Tightening torque: max. 1 Nm
(according to IEC 68-1)
Terminal capacity:
Storage temperature: -25 to +70 °C
1 x 0.5 to 2.5 mm² with/without multicore cable end
Transport temperature: -25 to +70 °C
1 x 4 mm² without multicore cable end
Relative humidity: 15% to 85%
2 x 0.5 to 1.5 mm² with/without multicore cable end
(according to IEC 721-3-3 class 3K3)
2 x 2.5 mm² flexible without multicore cable end
Pollution degree: 2, if built in 3
5. Input circuit (according to IEC 664-1)
Supply voltage: terminals A1(+)-A2 Vibrations resistance: 10 to 55 Hz 0.35 mm
Type ZR5MF025 12 to 240 V AC/DC (according to IEC 68-2-6)
Tolerance: 12 V-10% to 240 V+10% Shock resistance: 15 g 11 ms
Rated consumption: 6
4 VA (2 W)W)
(1.5 (according to IEC 68-2-27)
Rated frequency: AC 48 to 63 Hz
Duty cycle: 100%
Reset time: 100 ms
Residual ripple for DC: 10%
Drop-out voltage: >30% of minimum rated supply
voltage
TIME RELAYS

w FUNCTIONS
ON delay (E) Single shot leading edge voltage controlled (Wu)
When the supply voltage U is applied, the set interval t begins (green When the supply voltage U is applied, the output relay R switches
LED U/t flashes). After the interval t has expired (green LED U/t into on-position (yellow LED illuminated) and the set interval t begins
illuminated) the output relay R switches into on-position (yellow LED (green LED U/t flashes). After the interval t has expired (green LED U/t
illuminated). This status remains until the supply voltage is interrupted. illuminated) the output relay switches into off-position (yellow LED not
If the supply voltage is interrupted before the expiry of the interval t, illuminated). This status remains until the supply voltage is interrupted.
the interval already expired is erased and is restarted when the supply If the supply voltage is interruted before the interval t has expired, the
voltage is next applied. output relay switches into off-position. The interval already is erased
and is restarted when the supply voltage is next applied.

OFF delay (R)


The supply voltage U must be constantly applied to the device (green Flasher pause first (Bp)
LED U/t illuminated). When the control contact S is closed, the output When the supply voltage U is applied, the set interval t begins (green
relay R switches into on-position (yellow LED illuminated). If the control LED U/t flashes). After the interval t has expired, the output relay R
contact is opened, the set interval t begins (green LED U/t flashes). switches into on-position (yellow LED illuminated) and the set interval t
After the interval t has expired (green LED U/t illuminated) the output begins again. After the interval t has expired, the output relay switches
relay switches into off-position (yellow LED not illuminated). If the control into off-position (yellow LED not illuminated).
contact is closed again before the interval t has expired, the interval The output relay is triggered at a ratio of 1:1 until the supply voltage is
already expired is erased and is restarted. interrupted.

Single shot leading edge with control input (Ws) w CONNECTIONS


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). When the control contact S is closed, the output with control input without control input
relay R switches into on-position (green LED U/t illuminated) and the
set interval t begins (green LED U/t flashes). After the interval t has
expired (green LED U/t illuminated) the output relay switches into
off-position (yellow LED not illuminated). During the interval, the control
contact can be operated any number of times. A further cycle can only
be started when the cycle run has been completed.

Single shot trailling edge with control input (Wa) Page


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). Closing the control contact S has no influence on
483
w DIMENSIONS
the condition of the output R. When the control contact is opened, the
output relay switches into on-position (yellow LED illuminated) and the
set interval t begins (green LED U/t flashes). After the interval t has expired
(green LED U/t illuminated), the ouput relay switches into off-position (yel-
low LED not illuminated). During the interval, the control contact can be
operated any number of times. A further cycle can only be started when
the cycle run has been completed.

ON delay with control input (Es)


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). When teh control contact S is closed, the set
interval t begins (green LED U/t flashes). After the interval t has expired w WEIGHT
(green LED U/t illuminated) the output relay R switches into on-posi-
tion (yellow LED illuminated). This status remains until the control Single packing: 72 g
contact is opened again. If the control contact is opened before the Package 10 pcs: 670 g per Package
interval t has expired , the interval already expired is erased and is
restarted with the next cycle.
W ARTICLE NUMBER
DESCRIPTION ORDER NO.
Multifunction timerelay E, R, Ws, Wa, Es, Wu, Bp,
12-240VAC, 1 change over, 8A/250V ZR5MF011

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Multifunction time relay E, R, Ws, Wa, Es, Wu, Bp, 12-240VAC, 1 change over, 8A/250V 9004840459043 ZR5MF011

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w MULTIFUNCTION TIME RELAY ZR5MF025

w SCHRACK-INFO
• Timers multifunctional
• Up to 7 functions
• 7 time ranges
• Wide input voltage range
• 2 change-over contacts
• Width 35 mm
• Installation design

w TECHNICAL DATA

1. Functions Overvoltage category: III (according to IEC 60664-1)


The functions has to be set before connecting the relay to Rated surge voltage: 4kV
the supply voltage.
6. Output circuit
E ON delay
2 potential free change over contacts
R OFF delay
Rated voltage: 250 V AC
Ws Single shot leading edge with control input
Switching capacity: 2000 VA (8 A / 250 V)
Wa Single shot trailing edge with control input
Fusing: 8 A fast acting
Es ON delay with control input
Mechanical life: 20 x 106 operations
Wu Single shot leading edge voltage controlled
Electrical life: 2 x 105 operations
Bp Flasher pause first
at 1000 VA resistive load
2. Time ranges Switching frequency: max. 60/min at 100VA resistive load
Time range Adjustment range max. 6/min at 1000VA resistive load
1s 50 ms 1s (according to IEC 947-5-1)
10 s 500 ms 10 s Overvoltage category: III. (according to IEC 60664-1)
1 min 3s 1 min Rated surge voltage: 4kV
10 min 30 s 10 min
7. Control input
1h 3 min 1h
Input not potential free: terminals A1-B1
10 h 30 min 10 h
Loadable: yes
100 h 5h 100 h
Max. line length: 10m
Page 3. Indicators Trigger level (sensitivity): automatic adaption to supply voltage
484 Green LED U/t ON: indication of supply voltage Min. control pulse length: DC 50 ms / AC 100 ms
Green LED U/t flashes: indication of time period
8. Accuracy
Yellow LED R ON/OFF: indication of relay output
Base accuracy: ±1% of maximum scale value
4. Mechanical design Adjustment accuracy: <5% of maximum scale value
Self-extinguishing plastic housing, IP rating IP40 Repetition accuracy: <0.5% or ±5 ms
Mounted on DIN-rail TS 35 according to EN 50022 Voltage influence: -
Mounting position: any Temperature influence: ⱕ0.01% / °C
Shockproof terminal connection according to VBG 4 (PZ1 required),
9. Ambient conditions
IP rating IP20
Ambient temperature: -25 to +55 °C
Tightening torque: max. 1 Nm
(according to IEC 68-1)
Terminal capacity:
Storage temperature: -25 to +70 °C
1 x 0.5 to 2.5 mm² with/without multicore cable end
Transport temperature: -25 to +70 °C
1 x 4 mm² without multicore cable end
Relative humidity: 15% to 85%
2 x 0.5 to 1.5 mm² with/without multicore cable end
(according to IEC 721-3-3 class 3K3)
2 x 2.5 mm² flexible without multicore cable end
Pollution degree: 2, if built in 3
5. Input circuit (according to IEC 664-1)
Supply voltage: terminals A1(+)-A2 Vibrations resistance: 10 to 55 Hz 0.35 mm
Type ZR5MF025 12 to 240 V AC/DC (according to IEC 68-2-6)
Tolerance: 12 V-10% to 240 V+10% Shock resistance: 15 g 11 ms
Rated consumption: 6 VA (2 W) (according to IEC 68-2-27)
Rated frequency: AC 48 to 63 Hz
Duty cycle: 100%
Reset time: 100 ms
Residual ripple for DC: 10%
Drop-out voltage: >30% of minimum rated supply
voltage
TIME RELAYS

w FUNCTIONS
ON delay (E) Single shot leading edge voltage controlled (Wu)
When the supply voltage U is applied, the set interval t begins (green When the supply voltage U is applied, the output relay R switches
LED U/t flashes). After the interval t has expired (green LED U/t into on-position (yellow LED illuminated) and the set interval t begins
illuminated) the output relay R switches into on-position (yellow LED (green LED U/t flashes). After the interval t has expired (green LED U/t
illuminated). This status remains until the supply voltage is interrupted. illuminated) the output relay switches into off-position (yellow LED not
If the supply voltage is interrupted before the expiry of the interval t, illuminated). This status remains until the supply voltage is interrupted.
the interval already expired is erased and is restarted when the supply If the supply voltage is interruted before the interval t has expired, the
voltage is next applied. output relay switches into off-position. The interval already is erased
and is restarted when the supply voltage is next applied.

OFF delay (R)


The supply voltage U must be constantly applied to the device (green Flasher pause first (Bp)
LED U/t illuminated). When the control contact S is closed, the output When the supply voltage U is applied, the set interval t begins (green
relay R switches into on-position (yellow LED illuminated). If the control LED U/t flashes). After the interval t has expired, the output relay R
contact is opened, the set interval t begins (green LED U/t flashes). switches into on-position (yellow LED illuminated) and the set interval t
After the interval t has expired (green LED U/t illuminated) the output begins again. After the interval t has expired, the output relay switches
relay switches into off-position (yellow LED not illuminated). If the control into off-position (yellow LED not illuminated).
contact is closed again before the interval t has expired, the interval The output relay is triggered at a ratio of 1:1 until the supply voltage is
already expired is erased and is restarted. interrupted.

Single shot leading edge with control input (Ws) w CONNECTIONS


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). When the control contact S is closed, the output
relay R switches into on-position (green LED U/t illuminated) and the with control input without control input
set interval t begins (green LED U/t flashes). After the interval t has
expired (green LED U/t illuminated) the output relay switches into
off-position (yellow LED not illuminated). During the interval, the control
contact can be operated any number of times. A further cycle can only
be started when the cycle run has been completed.

Single shot trailling edge with control input (Wa) Page


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). Closing the control contact S has no influence on
485
the condition of the output R. When the control contact is opened, the w DIMENSIONS
output relay switches into on-position (yellow LED illuminated) and the
set interval t begins (green LED U/t flashes). After the interval t has expired
(green LED U/t illuminated), the ouput relay switches into off-position (yel-
low LED not illuminated). During the interval, the control contact can be
operated any number of times. A further cycle can only be started when
the cycle run has been completed.

ON delay with control input (Es)


The supply voltage U must be constantly applied to the device (green
LED U/t illuminated). When teh control contact S is closed, the set
interval t begins (green LED U/t flashes). After the interval t has expired
(green LED U/t illuminated) the output relay R switches into on-posi-
tion (yellow LED illuminated). This status remains until the control w WEIGHT
contact is opened again. If the control contact is opened before the
interval t has expired , the interval already expired is erased and is Single packing: 106g
restarted with the next cycle.

W ARTICLE NUMBER
DESCRIPTION ORDER NO.
Timerelay, multifunction, 12-240VAC, 2 change over, 8A/250V ZR5MF025

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Multifunction time relay, 12-240VAC, 2 change over, 8A/250V 9004840507287 ZR5MF025

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w MULTIFUNCTION TIME RELAY ZR6MF052

• 16 functions
• 16 time ranges
• Connection of remote potentiometer possible
• Zoom voltage 24 to 240V AC/DC
• 2 change-over contacts
• Width 22.5 mm
• Industrial design

w TECHNICAL DATA

1. Functions 3. Indicators
1 delayed contact (terminals 15-16-18) and Green LED ON: indication of supply voltage
1 instantaneous contact (terminals 25-26-28 Green LED flashes: indication of time period
E11 ON delay Yellow LED ON/OFF: indication of relay output
R11 OFF delay with control contact
Es11 ON delay with control contact 4. Mechanical design
Wu11 Single shot leading edge voltage controlled Self-extinguishing plastic housing, IP rating IP40
Ws11 Single shot leading edge with control contact Mounted on DIN-Rail TS 35 according to EN 60715
Wa11 Single shot trailing edge with control contact Mounting position: any
Bi11 Flasher pulse first Shockproof terminal connection according to VBG 4
Bp11 Flasher pause first (PZ1 required), IP rating IP20
Tightening torque: max. 1Nm
2 delayed contacts Terminal capacity:
E20 ON delay 1 x 0.5 bis 2.5 mm² with/without multicore cable end
R20 OFF delay with control contact 1 x 4 mm² without multicore cable end
Es20 ON delay with control contact 2 x 0.5 bis 1.5 mm² with/without multicore cable end
Wu20 Single shot leading edge voltage controlled 2 x 2.5 mm² flexible without multicore cable end
Ws20 Single shot leading edge with control contact
Page Wa20 Single shot trailing edge with control contact 5. Input circuit
Supply voltage:
486 Bi20 Flasher pulse first
24 to 240V AC/DC terminals A1-A2
Bp20 Flasher pause first
(galvanically separated)
2. Time ranges Tolerance:
Time range Adjustment range 24 to 240V DC -20% to +25%
1s 50ms 1s 24 to 240V AC -15% to +10%
3s 150ms 3s Rated frequency:
10s 500ms 10s 24 to 240V AC 48 to 400Hz
30s 1500ms 30s 48 to 240V AC 16 to 48Hz
1min 3s 1min Rated consumption: 4.5VA (1W)
3min 9s 3min Duration of operation: 100%
10min 30s 10min Reset time: 500ms
30min 90s 30min Wave form for AC: Sinus
1h 3min 1h Residual ripple for DC: 10%
3h 9min 3h Drop-out voltage: >15% of the supply voltage
10h 30min 10h Overvoltage category: III (in accordance with
30h 90min 30h IEC 60661-1)
1d 72min 1d Rated surge voltage: 4kV
3d 216min 3d
10d 12h 10d
30d 36h 30d
TIME RELAYS

6. Output circuit 8. Remote potentiometer (not included)


2 potential free change-over contacts The internal potentiometer is de-activated when a remote
Rated voltage: 250V AC potentio-meter is connected!
Switching capacity (distance <5mm): Connections: 1M1 potentiometer
750VA (3A / 250V AC) (type RONDO R2), terminals Z1-Y2
Switching capacity (distance >5mm): Line type: twisted pair
1250VA (5A / 250V AC) Control voltage: max. 5V
Fusing: 5A fast acting Short circuit current: max. μA
Mechanical life: 20 x 106 operations Line length: max. 5m
Electrical Life: 2 x 105 operations at
1000VA resistive load 9. Accuracy
Switching frequency: max. 60/min at 100VA Base accuracy: ±1% (of maximum scale value)
resistive load using 1M1 remote potentiometer
max. 6/min at 1000VA Frequency response: -
resistive load Adjustment accuracy: )5% (of maximum scale value)
(in accordance with IEC 60947-5-1) using 1M1 remote potentiometer
Overvoltage category: III (in accordance with IEC 60664-1) Repetition accuracy: <0.5% or ±5ms
Rated surge voltage: 4kV Voltage influence: -
Temperature influence: )0.01% / °C
7. Control contact
Activation: bridge Y1-Y2 10. Ambient conditions
Potential free: yes, basic isolation against Ambient temperature: -25 to +55°C
input and output circuit (in accordance with IEC 60068-1)
Loadable: no -25 to +40°C
Control voltage: max. 5V (in accordance with UL 508)
Short circuit current: max. 1mA Storage temperature: -25 to +70°C
Line length: max. 10m Transport temperature: -25 to +70°C
Control pulse length: min. 50ms Relative humidity: 15% to 85% (in accordance with
IEC 60721-3-3 class 3K3)
Pollution degree: 3 (in accordance with IEC 60664-1)
Vibration resistance: 10 to 55Hz 0.35 mm
(in accordance with IEC 60068-2-6)
Shock resistance: 15g 11ms (in accordance with
IEC 60068-2-27)
w FUNCTIONS
Page
The internal potentiometer is de-activated when a remote-poten- OFF delay with control contact (R11) 487
tio-meter is connected !The function has to be set before con- The supply voltage U must be constantly applied to the device
necting the relay to the supply voltage. (green LED illuminated). When the control contact Y1-Y2 is
closed, both contacts switch into on-position (yellow LED illumi-
ON delay (E11) nated). If the control contact is opened, the instantaneous contact
When the supply voltage U is applied, the instantaneous contact switches into off-position and the set interval t begins (green LED
switches into on-position and the set interval t begins (green LED flashes). After the interval t has expired (green LED illuminated)
flashes). After the interval t has expired (green LED illuminated) the the delayed contact switches into off-position (yellow LED not
delayed contact switches into on-position (yellow LED illuminated). illuminated). If the control contact is closed again before the
This status remains until the supply voltage is interrupted. If the interval t has expired, the interval already expired is erased and is
supply voltage is interrupted before the expiry of the interval t, the restarted with the next cycle.
interval already expired is erased and is restarted when the supply
voltage is next applied.
U

LED U

U Y1-Y2

R15-16-18
LED U
R25-26-28
R15-16-18

R25-26-28 t <t

t <t
TIME RELAYS

ON delay with control contact (Es11) Single shot trailing edge with control contact (Wa11)
The supply voltage U must be constantly applied to the device The supply voltage U must be constantly applied to the device
(green LED illuminated). When the control contact Y1-Y2 is (green LED illuminated). When the control contact Y1-Y2 is closed
closed, the instantaneous contact switches into on-position and the instantaneous contact switches into on-position. When the
the set interval t begins (green LED flashes). After the interval t control contact is opened, the instantaneous contact switches
has expired (green LED illuminated) the delayed contact switches into off-position, the delayed contact switches into on-position
into on-position (yellow LED illuminated). This status remains until (yellow LED illuminated) and the set interval t begins (green LED
the control contact is opened again .If the control contact is flashes). After the interval t has expired (green LED illuminated),
opened before the interval t has expired, the interval already the delayed contact switches into off-position (yellow LED not illu-
expired is erased and is restarted with the next cycle. minated). During the interval, the control contact (and the instan-
taneous contact) can be operated any number of times. A further
cycle can only be started when the cycle run has been completed.
U

LED U

Y1-Y2 U

R15-16-18 LED U

R25-26-28 Y1-Y2

R15-16-18
t <t
R25-26-28

Single shot leading edge voltage controlled (Wu11) t t

When the supply voltage U is applied, both contacts switch into


on-position (yellow LED illuminated) and the set interval t begins Flasher pulse first (Bi11)
(green LED flashes). After the interval t has expired (green LED When the supply voltage U is applied, the instantaneous contact
illuminated) the delayed contact switches into off-position (yellow and the delayed contact switch into on-position (yellow LED illu-
LED not illuminated). This status remains until the supply voltage minated) and the set interval t begins (green LED flashes). After
is interrupted. If the supply voltage is interrupted before the inter- the interval t has expired, the delayed contact switches into off-
val t has expired, the both contacts switch into off-position. The position (yellow LED not illuminated) and the set interval t begins
interval already expired is erased and is restarted when the supply again. The delayed contact is triggered at a ratio of 1:1 until the
voltage is next applied. supply voltage is interrupted.

U U

LED U LED U
R15-16-18 R15-16-18

R25-26-28 R25-26-28
Page
488 t <t t t t t t

Single shot leading edge with control contact (Ws11) Flasher pause first (Bp11)
The supply voltage U must be constantly applied to the device When the supply voltage U is applied, the instantaneous contact
(green LED illuminated). When the control contact Y1-Y2 is switches into on-position and the set interval t begins (green LED
closed, both contacts switch into on-position (yellow LED illumi- flashes). After the interval t has expired, the delayed contact
nated) and the set interval t begins (green LED flashes). After the switches into on-position (yellow LED illuminated) and the set
interval t has expired (green LED illuminated) the delayed contact interval t begins again. After the interval t has expired, the
switches into off-position (yellow LED not illuminated). The delayed contact switches into off-position (yellow LED not illumi-
instantaneous contact remains in on-position, until the control nated). The delayed contact is triggered at a ratio of 1:1 until the
contact is opened again. During the interval, the control contact supply voltage is interrupted.
(and the instantaneous contact) can be operated any number of
times.A further cycle can only be started when the cycle run has
U
been completed.
LED U

R15-16-18
U
R25-26-28
LED U

Y1-Y2
t t t t
R15-16-18

R25-26-28

t t
TIME RELAYS

ON delay (E20) Single shot leading edge voltage controlled (Wu20)


When the supply voltage U is applied, the set interval t begins When the supply voltage U is applied, the output relay R switch-
(green LED flashes). After the interval t has expired (green LED es into on-position (yellow LED illuminated) and the set interval t
illuminated) the output relay R switches into on-position (yellow begins (green LED flashes). After the interval t has expired (green
LED illuminated). This status remains until the supply voltage is LED illuminated) the output relay switches into off-position (yel-
interrupted.If the supply voltage is interrupted before the expiry low LED not illuminated). This status remains until the supply volt-
of the interval t, the interval already expired is erased and is age is interrupted. If the supply voltage is interrupted before the
restarted when the supply voltage is next applied. interval t has expired, the output relay switches into off-position.
The interval already expired is erased and is restarted when the
supply voltage is next applied.
U

LED U
R15-16-18 U

R25-26-28 LED U

R15-16-18
t <t
R25-26-28

OFF delay with control contact (R20) t <t


The supply voltage U must be constantly applied to the device
(green LED illuminated). When the control contact Y1-Y2 is Single shot leading edge with control contact (Ws20)
closed, the output relay R switches into on-position (yellow LED The supply voltage U must be constantly applied to the device
illuminated). If the control contact is opened, the set interval t (green LED illuminated). When the control contact Y1-Y2 is
begins (green LED flashes). After the interval t has expired (green closed, the output relay R switches into on-position (yellow LED
LED illuminated) the output relay switches into off-position (yel- illuminated) and the set interval t begins (green LED flashes). After
low LED not illuminated). If the control contact is closed again the interval t has expired (green LED illuminated) the output relay
before the interval t has expired, the interval already expired is switches into off-position (yellow LED not illuminated). During the
erased and is restarted with the next cycle. interval, the control contact can be operated any number of
times. A further cycle can only be started when the cycle run has
U
been completed.
LED U

Y1-Y2 U

R15-16-18 LED U

R25-26-28 Y1-Y2

R15-16-18
t <t
R25-26-28
Page
ON delay with control contact (Es20)
The supply voltage U must be constantly applied to the device
t t
489
(green LED illuminated). When the control contact Y1-Y2 is Single shot trailing edge with control contact (Wa20)
closed, the set interval t begins (green LED flashes). After the The supply voltage U must be constantly applied to the device
interval t has expired (green LED illuminated) the output relay R (green LED illuminated). Closing the control contact Y1-Y2 has no
switches into on-position (yellow LED illuminated). This status influence on the condition of the output relay R. When the con-
remains until the control contact is opened again. If the control trol contact is opened, the output relay switches into on-position
contact is opened before the interval t has expired, the interval (yellow LED illuminated) and the set interval t begins (green LED
already expired is erased and is restarted with the next cycle. flashes). After the interval t has expired (green LED illuminated),
the output relay switches into off-position (yellow LED not illumi-
U
nated). During the interval, the control contact can be operated
any number of times. A further cycle can only be started when the
LED U
cycle run has been completed.
Y1-Y2

R15-16-18

R25-26-28 U

LED U
t <t
Y1-Y2

R15-16-18

R25-26-28

t t
TIME RELAYS

Flasher pulse first (Bi20) Flasher pause first (Bp20)


When the supply voltage U is applied, the output relay R switch- When the supply voltage U is applied, the set interval t begins
es into on-position (yellow LED illuminated) and the set interval t (green LED flashes). After the interval t has expired, the output
begins (green LED flashes). After the interval t has expired, the relay R switches into on-position (yellow LED illuminated) and the
output relay switches into off-position (yellow LED not illuminat- set interval t begins again. After the interval t has expired, the
ed) and the set interval t begins again. The output relay is output relay switches into off-position (yellow LED not illuminat-
triggered at a ratio of 1:1 until the supply voltage is interrupted. ed). The output relay is triggered at a ratio of 1:1 until the supply
voltage is interrupted.

LED U U

R15-16-18 LED U

R25-26-28 R15-16-18

R25-26-28
t t t t t
t t t t t

w CONNECTIONS w DIMENSIONS

2 R2
S
3

A1 Y1 15
Z1 Y2

15 25

16 18 26 28

25 26 28
Page
16 18 A2
490

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Multifunction time relay, 2 change over, 24-240V AC/DC, industrial design 9004840557466 ZR6MF052

I KNOW WHERE TO FIND IT!

WITH THE SCHRACK TECHNIK LiVE-PHONE APP

• Access technical product information at any time and from everywhere


• See availability and price immediately
• Order desired products easily

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w FLASHER TIME RELAY ZR5B0011

w SCHRACK-INFO
• Asymmetric flasher
• 7 time ranges
• Wide input voltage range
• 1 change over contact
• Width 17,5 mm
• Installation design

w TECHNICAL DATA

1. Functions 6. Output circuit


Ip Asymmetric flasher pause first 1 potential free change over contact
Ii Asymmetric flasher pulse first Rated voltage: 250 V AC
(A1-B1 bridged) Switching capacity: 2000 VA (8 A / 250 V)
Fusing: 8 A fast acting
2. Time ranges Mechanical life: 20 x 106 operations
Time range Adjustment range Electrical life: 2 x 105 operations
1s 50 ms 1s at 1000 VA resistive load
10 s 500 ms 10 s Switching frequency: max. 60/min at 100 VA resistive
1 min 3s 1 min load
10 min 30 s 10 min max. 6/min at 1000 VA resistive
1h 3 min 1h load
10 h 30 min 10 h (according to IEC 947-5-1)
100 h 5h 100 h Overvoltage category: III. (according to IEC 60664-1)
Rated surge voltage: 4 kV
3. Indicators
Green LED U/t ON: indication of supply voltage
Green LED U/t slow flashing: indication of time period t1 7. Control input
Green LED U/t fast flashing: indication of time period t2 Input not potential free: Terminals A1-B1
Yellow LED R ON/OFF: indication of relay output Loadable: yes
Max. line length: 10 m
Trigger level (sensitivity):
automatic adaption to supply Page
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP40 voltage 491
Mounted on DIN-rail TS 35 according to EN 50022 Min. control pulse length: DC 50 ms / AC 100 ms
Mounting position: any
Shockproof terminal connection according to VBG 4 (PZ1 required), 8. Accuracy
IP rating IP20 Base accuracy: ±1% of maximum scale value
Tightening torque: max. 1 Nm Adjustment accuracy: <5% of maximum scale value
Terminal capacity: Repetition accuracy: <0.5% or ±5 ms
1 x 0.5 to 2.5 mm² with/without multicore cable end Voltage influence: -
1 x 4 mm² without multicore cable end Temperature influence: ⱕ0.01% / °C
2 x 0.5 to 1.5 mm² with/without multicore cable end
2 x 2.5mm ² flexible without multicore cable end 9. Ambient conditions
Ambient temperature: -25 to +55 °C (according to IEC 68-1)
5. Input circuit Storage temperature: -25 to +70 °C
Supply voltage: Terminals A1(+)-A2 Transport temperature: -25 to +70 °C
Type ZR5B0011 Relative humidity: 15% to 85%
12-240 V AC/DC: 12 to 240 V AC/DC (according to IEC 721-3-3 class 3K3)
Tolerance: 12 V-10% to 240 V+10% Pollution degree: 2, if built in 3
Rated consumption: 4 VA (1.5 W) (according to IEC 664-1)
Rated frequency: AC 48 to 63 Hz Vibration resistance: 10 to 55 Hz 0.35 mm
Duty cycle: 100% (according to IEC 68-2-6)
Reset time: 100 ms Shock resistance: 15 g 11 ms
Residual ripple for DC: 10% (according to IEC 68-2-27)
Drop-out voltage: >30% of minimum rated supply
voltage
Overvoltage category: III (according to IEC 60664-1)
Rated surge voltage: 4 kV
TIME RELAYS

w FUNCTIONS w CONNECTIONS
Asymmetric flasher pause first (Ip)
When the supply voltage U is applied, the set interval t1
begins (green LED U/t flashes slowly). After the interval t1
has expired, the output relay R switches into on-position
(yellow LED illuminated) and the set interval t2 begins
(green LED U/t flashes fast). After the interval t2 has
expired, the output relay switches into off-position (yellow
LED not illuminated).

The output relay is triggered at the ratio of t1:t2 until the


supply voltage is interrupted.

Asymmetric flasher pulse first (Ii) w DIMENSIONS


When the supply voltage U is applied, the output relay R
switches into on-position (yellow LED illuminated) and the
set interval t1 begins (green LED U/t flashes slowly). After the
interval t1 has expired, the output relay switches into off-
position (yellow LED not illuminated) and the set interval t2
begins (green LED U/t flashes fast). After the interval t2 has
expired, the output relay switches into on-position (yellow
LED illuminated).

The output relay is triggered at the ratio of t1:t2 until the


supply voltage is interrupted

Page
492
w WEIGHT W ARTICLE NUMBER
Single packing: 72 g DESCRIPTION ORDER NO.
Package 10 pcs: 670 g per Package
Timerelay, 12-240VAC, 1 change over, 8A/250V ZR5B0011

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Flasher time relay, 12-240VAC, 1 change over, 8A/250V 9004840459012 ZR5B0011

I KNOW WHERE TO FIND IT!

THE SCHRACK TECHNIK WEB SHOP WITH NAVIGATOR


WWW.SCHRACK.COM

• Finding product information made easy


• Buying products around the clock
• Quick access customer service

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w PULSE TIME RELAY ZR5B0025

w SCHRACK-INFO

• Asymmetric flasher, 2-time multifu


• 7 Time ranges
• Wide input voltage range
• 2 change-over contacts
• Width 35 mm
• Installation design

w TECHNICAL DATA

1. Functions Reset time: 100 ms


The function has to be set before connecting the relay to the Residual ripple of DC: -
supply voltage. Drop-out voltage: >30% of the supply voltage
Ip Asymmetric flasher pause first Overvoltage category: III (according to IEC 60664-1)
Ii Asymmetric flasher pulse first Rated surge voltage: 4kV
ER ON delay and OFF delay with control contact
6. Output circuit
EWu ON delay single shot leading edge voltage controlled
2 potential free change over contacts
EWs ON delay single shot leading edge with control
Rated voltage: 250 V AC
contact
Switching capacity: 2000 VA (8 A / 250 V)
WsWa Single shot leading and single shot trailling edge
Fusing: 8 A fast acting
with control contact
Mechanical life: 20 x 106 operations
Wt Pulse sequence monitoring
Electrical life: 2 x 105 operations
2. Time ranges at 1000 VA resistive load
Time range Adjustment range Switching frequency: max. 60/min at 100 VA resistive load
1s 50 ms 1s max. 6/min at 1000 VA resistive load
10 s 500 ms 10 s (according to IEC 947-5-1)
1 min 3s 1 min Overvoltage category: III (according to IEC 60664-1)
10 min 30 s 10 min Rated surge: 4 kV
1h 3 min 1h
7. Control input
10 h 30 min 10 h Page
Input not potential free: terminals A1-B1
100 h 5h 100 h
3. Indicators
Loadable:
Max. line length:
yes
10 m
493
Green LED U/t ON: indication of supply voltage Trigger level (sensitivity): automatic adaption to supply voltage
Green LED U/t slow flashing: indication of time period t1 Max. control pulse length: DC 50 ms / AC 100 ms
Green LED U/t fast flashing: indication of time period t2
8. Accuracy
Yellow LED ON/OFF: indication of relay output
Base accuracy: ±1% of maximum scale value
4. Mechanical design Adjusting accuracy: ⱕ5% of maximum scale value
Self-extinguishing plastic housing, IP rating IP40 Repetition accuracy: <0.5% or ±5 ms
Mouted on DIN-rail TS 35 according to EN 50022 Voltage influence: -
Mounting position: any Temperature influence: ⱕ0.01% / °C
Shockproof terminal connection according to VBG 4 (PZ1 required),
9. Ambient conditions
IP rating IP20
Ambient temperature: -25 to +55 °C (according to IEC 68-1)
Tightening torque: max. 1 Nm
Storage temperature: -25 to +70 °C
Terminal capacity:
Transport temperature: -25 to +70 °C
1 x 0.5 to 2.5 mm² with/without multicore cable end
Relative humidity: 15% to 85%
1 x 4 mm² without multicore cable end
(according to IEC 721-3-3 class 3K3)
2 x 0.5 to 1.5 mm² with/without multicore cable end
Pollution degree: 2, if built in 3
2 x 2.5 mm² flexible without multicore cable end
(according to IEC 664-1)
5. Input circuit Vibration resistance: 10 to 55 Hz 0.35 mm
Supply voltage: terminals A1(+) - A2 (according to IEC 68-2-6)
Types ZR5B0025 Shock resistance: 15 g 11 ms
12-240 V AC/DC: 12 to 240 V AC/DC (according to IEC 68-2-27)
Tolerance: 12 V-10% to 240 V+10%
Rated frequency: 48 to 63 Hz
Rated consumption: 6 VA (2 W)
Duration of operation: 100%
TIME RELAYS

w FUNCTIONS
Asymmetric flasher pause first (lp)
When the supply voltage U is applied, the set interval t1 begins (green
LED U/t flashes slowly). After the interval t1 has expired, the output
relay R switches into on-position (yellow LED illuminated) and the set
interval t2 begins (green LED U/t flashes fast). After the interval t2 has
expired, the output relay switches into off-position (yellow LED not Single shot leading and single shot trailing edge
illuminated). The output relay is triggered at the ratio of t1:t2 until the with control contact (WsWa)
supply voltage is interrupted. The supply voltage U must be constantly applied to the device (green LED
U/t illuminated). When the control contact S is closed, the output relay
R switches into on-position (yellow LED illuminated) and the set interval
t1 begins (green LED U/t flashes slowly). After the interval t1 has expired,
the output relay R switches into off-position (yellow LED not illuminated).
If the control contact is opened, the output relay again switches into on-
Asymmetric flasher pulse first (li)
position (yellow LED illuminated) and the set interval t2 begins (green
When the supply voltage U is applied, the output relay R switches into
LED U/t flashes fast). After the interval t2 has expired the output relay
on-position (yellow LED illuminated) and the set interval t1 begins (green
switches into off-position (yellow LED not illuminated). During the inter-
LED U/t flashes slowly). After the interval t1 has expired, the output relay
val, the control contact can be operated any number of times.
switches into off-position (yellow LED not illuminated) and the set interval
t2 begins (green LED U/t flashes fast). After the interval t2 has expired,
the output relay switches into on-position (yellow LED illuminated). The
output relay is triggered at the ratio of t1:t2 until the supply voltage is
interrupted.

Pulse sequence monitoring (Wt)


When the supply voltage U is applied, the set interval t1 begins (green
LED U/t flashes slowly) and the output relay R switches into on-position
(yellow LED illuminated) After the interval t1 has expired, the set interval
ON delay and OFF delay with control contact (ER) t2 begins (green LED U/t flashes fast). So that the output relay R remains
The supply voltage U must be constantly applied to the device (green LED in on-position, the control contact S must be closed and opened again
U/t illuminated). When the control contact S is closed, the set interval t1 within the set interval t2. If this does not happen, the output relay R
begins (green LED U/t flashes slowly). After the interval t1 has expired, the switches into off-position (yellow LED not illuminated) and all further
output relay R switches into on-position (yellow LED illuminated). If the pulses at the control contact are ignored. To restart the function the
control contact is opened, the set interval t2 begins (green LED U/t flashes supply voltage must be interrupted and reapplied.
fast). After the interval t2 has expired, the output relay switches into
off-position (yellow LED not illuminated). If the control contact is opened
before the interval t1 has expired, the interval already expired is erased
and is restarted with the next cycle.

Page
w CONNECTIONS w DIMENSIONS
494
ON delay and single shot leading edge voltage
controlled (EWu)
When the supply voltage U is applied, the set interval t1 begins (green LED
U/t flashes slowly). After the interval t1 has expired, the output relay R
switches into on-position (yellow LED illuminated) and the set interval t2
begins (green LED U/t flashes fast). After the interval t2 has expired, the
output relay switches into off-position (yellow LED not illuminated). If the
supply voltage is interrupted before the interval t1+t2 has expired, the
interval already expired is erased and is restarted when the supply voltage
is next applied.

w WEIGHT
Single packing: 106g
ON delay and single shot leading edge
with control contact (EWs)
The supply voltage U must be constantly applied to the device W ARTICLE NUMBER
(green LED U/t illuminated). When the control contact S is closed,
the set interval t1 begins (green LED U/t flashes slowly). After the DESCRIPTION ORDER NO.
interval t1 has expired, the output relay R switches into on-position
(yellow LED illuminated) and the set interval t2 begins (green LED Timerelay, 7 functions, 12-240VAC, 2 change over, 8A/250V ZR5B0025
U/t flashes fast). After the interval t2 has expired, the output relay
switches into off-position (yellow LED not illuminated).
During the interval, the control contact can be operated any number
of times. A further cycle can only be started when the cycle run has
been completed.

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Pulse time relay, 7 functions, 12-240VAC, 2 change over, 8A/250V 9004840507263 ZR5B0025

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w STAR-DELTA-RELAY ZR5SD025

w SCHRACK-INFO

• Star-Delta start up
• 2 change-over contacts
• Wide input voltage ran
• Width 35 mm
• Installation design

w TECHNICAL DATA

1. Functions Reset time: 100 ms


S Star-delta start up Residual ripple of DC: 10%
Drop-out voltage: >30% of the supply voltage
2. Time ranges Overvoltage category: III (according to IEC 60664-1)
Start-up time Rated surge voltage: 4 kV
Time range Adjustment range
10 s 500 ms 10 s 6. Output circuit
30 s 1500 ms 30 s 2 potential free change over contacts
1 min 3s 1 min Rated surge: 250 V AC
3 min 9s 3 min Switching capacity: 2000 VA (8 A / 250 V)
Fusing: 8 A fast acting
Transit time (fixed) Mechanical life: 20 x 106 operations
40 ms Electrical life: 2 x 105 operations
60 ms at 1000 VA resistive load
80 ms Switching frequency: max. 60/min at 100 VA
100 ms resistive load
max. 6/min at 1000 VA
3. Indicators resistive load
Green LED U/t ON: indication of supply voltage (according to IEC 947-5-1)
delta-contactor in on-position Overvoltage category: III. (according to IEC 60664-1) Page
(terminals 25-28) Rated surge voltage: 4 kV
Green LED U/t flashes: indication of time period star time
495
Yellow LED R ON/OFF: indication of star contactor 7. Accuracy
(terminals 15-18) Base accuracy: ±1% of maximum scale value
Adjustment accuracy: <5% of maximum scale value
4. Mechanical design Repetition accuracy: <0.5% or ±5 ms
Self-extinguishing plastic housing, IP rating IP40 Voltage influence: -
Mounted on DIN-rail TS 35 according to EN 50022 Temperature influence: ⱕ0.01% / °C
Mounting position: any
Shockproof terminal connection according to VBG 4 (PZ1 required),
8. Ambient conditions
IP rating IP20
Ambient temperature: -25 to +55 °C
Tightening torque: max. 1 Nm
(according to IEC 68-1)
Terminal capacity:
Storage temperature: -25 to +70 °C
1 x 0.5 to 2.5 mm² with/without multicore cable end
Transport temperature: -25 to +70 °C
1 x 4 mm² without multicore cable end
Relative humidity: 15% to 85%
2 x 0.5 to 1.5 mm² with/without multicore cable end
(according to IEC 721-3-3
2 x 2.5 mm² flexible without multicore cable end
Klasse 3K3)
Pollution degree: 2, if built in 3
5. Input circuit
(according to IEC 664-1)
Supply voltage: terminals A1(+)-A2
Vibration resistance: 10 to 55 Hz 0.35 mm
Type ZR5SD025 12 to 240 V AC/DC
(according to IEC 68-2-6)
Tolerance: 12 V-10% to 240 V+10%
Shock resistance: 15 g 11 ms
Rated consumption: 4 VA (1.5 W)
(according to IEC 68-2-27)
Rated frequency: AC 48 to 63Hz
Duty cycle: 100%
TIME RELAYS

w FUNCTIONS w CONNECTIONS

Star-delta start up
When the supply voltage U is applied, the star-contact
switches into on-position (yellow LED illuminated) and the
set star-time t1 begins (green LED U/t flashes). After the
interval t1 has expired (green LED U/t illuminated), the
star-contact switches into off-position (yellow LED not
illuminated) and the set transit-time t2 begins. After the
interval t2 has expired, the contact for the delta-contactor
switches into on-position. To restart the function, the supply
voltage must be interrupted and reapplied.

w
w WEIGHT
GEWICHT w DIMENSIONS
Single packing: 106 g

W ARTICLE NUMBER
DESCRIPTION ORDER NO.
Star-Delta-relay, 12-240VAC, 2 change over ZR5SD025

Page
496

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Star-delta-relay, 12-240VAC, 2 change over 9004840507300 ZR5SD025

I KNOW WHERE TO FIND IT!

WITH THE SCHRACK TECHNIK LiVE-PHONE APP

• Access technical product information at any time and from everywhere


• See availability and price immediately
• Order desired products easily

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w STAR-DELTA-RELAY ZR6SD052

• Star-Delta start-up
• Supply voltage selectable via power modules
• 2 change-over contacts
• Width 22.5 mm
• Industrial design

w TECHNICAL DATA

1. Functions 5. Input circuit


S Star-Delta start-up Supply voltage:
12 to 400V AC terminals A1-A2 (galvanically
2. Zeitbereiche separated) selectable via power
Start-up time modules TR2
Time range Adjustment range Tolerance: according to specification of
10s 500ms 1s power module
3s 1500ms 30s Rated frequency: according to specification of
1min 3s 1min power module
3min 9s 3min Rated consumption: 2VA (1.5W)
Duration of operation: 100%
Transit time Reset time: 100ms
Time range (fixed) Residual ripple for DC: -
40ms Drop-out voltage: >30% of the supply voltage
60ms Overvoltage category: III (in accordance with
80ms IEC 60664-1)
100ms Rated surge voltage: 4kV

3. Indicators 6. Output circuit Page


Green LED ON: indication of supply voltage 2 potential free change-over contacts
delta-contactor in on-position Rated voltage: 250V AC
497
(terminals 25-28) Schaltleistung: 750VA (3A / 250V AC)
Green LED flashes: indication of star-time If the distance between the devices is less than 5mm!
Yellow LED ON/OFF: indication of star-contactor Switching capacity: 1250VA (5A / 250V AC)
(terminals 15-18) If the distance between the devices is greater than 5mm!
Fusing: 5A fast acting
4. Mechanical design Mechanical life: 20 x 106 operations
Self-extinguishing plastic housing, IP rating IP40 Electrical Life: 2 x 105 operations at 1000VA
Mounted on DIN-Rail TS 35 according to EN 50022 resistive load
Mounting position: any Switching frequency: max. 60/min bei 100VA
Shockproof terminal connection according to VBG 4 resistive load
(PZ1 required), IP rating IP20 max. 6/min bei 1000VA
Tightening torque: max. 1Nm resistive load (in accordance with
Terminal capacity: IEC 60947-5-1)
1 x 0.5 bis 2.5 mm² with/without multicore cable end Overvoltage category: III (in accordance with IEC 60664-1)
1 x 4 mm² without multicore cable end Rated surge voltage: 4kV
2 x 0.5 bis 1.5 mm² with/without multicore cable end
2 x 2.5 mm² flexible without multicore cable end 7. Accuracy
Base accuracy: ±1% (of maximum scale value)
Frequency response: -
Adjustment accuracy: )5% (of maximum scale value)
Repetition accuracy: <0.5% or ±5ms
Voltage influence: -
emperature influence: )0.01% / °C
TIME RELAYS

8. Ambient conditions w FUNCTIONS


Ambient temperature: -25 to +55°C
(in accordance with IEC 60068-1) Star-Delta start-up (S)
-25 to +40°C When the supply voltage U is applied, the star-contact switches
(in accordance with UL 508) into on-position (yellow LED illuminated) and the set star-time t1
Storage temperature: -25 to +70°C begins (green LED flashing). After the interval t1 has expired
Transport temperature: -25 to +70°C (green LED il-luminated) the star-contact switches into off-posi-
Relative humidity: 15% to 85% (in accordance with tion (yellow LED not illuminated) and the set transit-time t2
IEC 60721-3-3 class 3K3) begins. After the interval t2 has expired the delta-contact switch-
Pollution degree: 3 (in accordance with IEC 60664-1) es into on-position. To restart the function the supply voltage
Vibration resistance: 10 to 55Hz 0.35mm must be interrupted and re-applied.
(in accordance with IEC 60068-2-6)
Shock resistance: 15g 11ms (in accordance with
IEC 60068-2-27) U

LED U

R15-16-18

R25-26-28

t1 t2

w CONNECTIONS w DIMENSIONS
CONNECTIONS

A1 15

15 25

16 18 26 28

Page 25 26 28
16 18 A2
498

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Star-delta-relay, 2 change over, industrial design 9004840557459 ZR6SD052

I KNOW WHERE TO FIND IT!

THE SCHRACK TECHNIK WEB SHOP WITH NAVIGATOR


WWW.SCHRACK.COM

• Finding product information made easy


• Buying products around the clock
• Quick access customer service

Order no. blue: on stock, usually ready for delivery on the day of order!
TIME RELAYS

w EMERGENCY LIGHT TEST RELAY ZR5RT011

• Timer for automatic test of emergency lights


• Integrated test key
• 1 change over contact
• Width 17.5 mm
• Installation design

w TECHNICAL DATA

1. Functions 6. Output circuit


Ws Single shot leading edge 1 change over contact
with control contact
NORMALLY OPEN CONTACT
2. Time ranges Terminals: L-18
Time range reversible between Rated voltage: 250V AC
10min, 30min, 60min, 90min, Switching capacity: 1250VA (5A / 250V AC)
2h and 3h
NORMALLY CLOSED CONTACT
3. Indicators Terminals: L-16
Green LED U/t ON: indication of supply voltage Rated voltage: 250V AC
Green LED U/t flashes: indication of time period t Switching capacity: 2500VA (10A / 250V AC)
Green LED U/t flashes fast: abort of time period t If the distance between the devices is less than 5mm!
Yellow LED ON/OFF: indication of relay output
Switching capacity: 4000VA (16A / 250V AC)
If the distance between the devices is greater than 5mm!
4. Mechanical design Start-up peak (20ms): 80A
Self-extinguishing plastic housing, IP rating IP 40 Page
Mounted on DIN-rail TS 35 according to EN 60715 Mechanical life: 30 x 106 operations 499
Mounting position: any Electrical life:
Shockproof terminal connection according to VBG 4 Resistive load: 105 operations at 16A 250V
(PZ1 required), IP rating IP20 Lamp load: 80.000 operations at 1000W 250V
Tightening torque: max. 1Nm
Terminal capacity: 7. Accuracy
1 x 0.5 to 2.5 mm² with/without multicore cable end Base accuracy: ±5%
1 x 4 mm² without multicore cable end Adjustment accuracy: -
2 x 0.5 to 1.5 mm² with/without multicore cable end Repetition accuracy: <2%
2 x 2.5 mm² flexible without multicore cable end Voltage influence: -
Temperature influence: )1%
5. Input circuit
Supply voltage: 230V AC 8. Ambient conditions
Terminals: L-N Ambient temperature: -25 to +55°C
Tolerance: -15% to +10% Storage temperature: -25 to +70°C
Rated frequency: 48 to 63Hz Transport temperature: -25 to +70°C
Rated consumption: 2VA (1.0W) Relative humidity: 15% to 85% (in accordance with
Duty cycle: 100% IEC 60721-3-3 class 3K3)
Reset time: 500ms Pollution degree: 2, if built in 3
Ripple and noise at DC: - (in accordance with IEC 60664-1)
Drop out voltage: >30% of supply voltage
Overvoltage category: III (in accordance with IEC 60664-1)
Rated surge voltage: 4kV
TIME RELAYS

w FUNCTIONS

Single shot leading edge with control contact (Ws)


The supply voltage U must be constantly to the device (green LED
U/t illuminated). Pressing the integrated test key forces the out-
put relay R to switch into on-position (yellow LED illuminated), so
the emergency ligths are disconnected from the mains and the U
set interval t begins (green LED U/t flashes). After the interval t
LED U/t
has expired (green LED U/t illuminated), the output relay R
switches into off-position (yellow LED not illuminated) and the
Ws Testkey
emergency lights are reconnected to the mains. During the R t
interval, the test key can be operated any number of times. >2s
Prolonged pressure on the test key (>2s) aborts the running test
interval (green LED U/t flashes fast) and a further cycle can be
started.

w CONNECTIONS
Direct connection of emergency lights (I < 16A) Switching emergency lights with contactor (I > 16A)
L L
N N
PE PE

16 L
16 L

L
Emergency lights with
integrated recharchable 16 18
power cells
Emergency lights with
16 18 integrated recharchable
power cells
18 N

18 N

Page
500 w DIMENSIONS
87mm
45mm

5mm 44mm
17,5mm
60mm

DESCRIPTION EAN CODE AVAILABLE ORDER NO.


Emergency light test relay 9004840557374 ZR5RT011

Order no. blue: on stock, usually ready for delivery on the day of order!