Member No : 13068 (600/400X10 thk + 2 FLG350X12 thk TO 450X10thk+2FLG300X12)

Node No : 7859

Fy = 146 KN , Mx = 0, Mz = 0

Size of Beam : 450 x 10 + 300 x 12

Web angle 150 x 150 x 12 thick

Strength of Rivet in double shear = 𝜑vf x L x A∅

𝜋 𝑥 252
= 80 x 2 x 4
= 78540.8 N

Strength of bearing for 12 mm web angle = 25 x 12 x 300 = 90000N

146 𝑥 1000
No of bolts required = = 1.85 no’s
78540.8

Say provided 3 no’s - 25 ∅ HT Bolts

Provide web angle ISA 150 x 150 x 12 thk - 350lg


Member No : 13067 (500/400X8 thk + 2 FLG300X12 thk TO 400X8thk+2FLG300X12)
Node No : 7856

Fy = 127 KN, Mx = 0, Mz = 0

Size of Beam : 400 x 8 + 300 x 12

Web angle 150 x 150 x 12 thick

Strength of Rivet in double shear = 𝜑vf x L x A∅

𝜋 𝑥 252
= 80 x 2 x 4
= 78540.8 N

Strength of bearing for 12 mm web angle = 25 x 12 x 300 = 90000N

127 𝑥 1000
No of bolts required = = 1.62 no’s
78540.8

Say provided 3 no’s - 25 ∅ HT Bolts

Provide web angle ISA 150 x 150 x 12 thk - 350lg


Member No : 18239 (400X8 thk + 2 FLG300X12 thk TO 400X8thk+2FLG300X12)
Node No : 7891

Fy = 68 KN, Mx = 0, Mz = 0

Size of Beam : 400 x 8 + 300 x 12

Web angle 150 x 150 x 12 thick

Strength of Rivet in double shear = 𝜑vf x L x A∅

𝜋 𝑥 252
= 80 x 2 x 4
= 78540.8 N

Strength of bearing for 12 mm web angle = 25 x 12 x 300 = 90000N

68 𝑥 1000
No of bolts required = = 0.87 no’s
78540.8

Say provided 3 no’s - 25 ∅ HT Bolts

Provide web angle ISA 150 x 150 x 12 thk - 350lg


Member No : 13364 (400X8 thk + 2 FLG300X12 thk TO 250X8thk+2FLG200X12)
Node No : 8016

Fy = 38 KN, Mx = 0, Mz = 0

Size of Beam : 250 x 8 + 200 x 12

Web angle 150 x 150 x 12 thick

Strength of Rivet in double shear = 𝜑vf x L x A∅

𝜋 𝑥 252
= 80 x 2 x 4
= 78540.8 N

Strength of bearing for 12 mm web angle = 25 x 12 x 300 = 90000N

38 𝑥 1000
No of bolts required = = 0.5 no’s
78540.8

Say provided 2 no’s - 25 ∅ HT Bolts

Provide web angle ISA 150 x 150 x 12 thk - 205lg