iPasolink 200

Digital Microwave Transmission System


Fast Data Configuration Guide
内部公开 Internal Use Only▲

NE Login
1. Connect the PC to the LCT port of IDU.

2. Set the IP address for PC as OBTAIN DSN SERVER ADDRESS AUTOMATICALLY”

3. Input the IP address of the NE and WebLCT in URL Address box:


http://172.17.254.253.The WebLCT login window appears, as shown

4. Input User Name: Admin, and Password: 12345678in textbox.


5. Press OK. The WebLCT main window appears

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第2页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Equipment Configuration
1. Expand Equipment Setup -> Equipment Configuration from the WebLCT
menu.
2. Click the Setup.

3. Input the Equipment Name, then Next.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第3页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲
4. Set Modem1 as used, and then click Next.

5. Confirm that the setup parameter changes to blue, and then click OK

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第4页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

6. Click OK in the pop-up Warning box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第5页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Radio Configuration
1. Expand Equipment Setup -> Radio Configuration from the WebLCT menu.
2. Click Setup. The Step1 Window appears

3. Input Channel Spacing /Modulation/TX frequency from Link Budget, Radio


mode :High capacity, Frame ID :1, TX power control : MTPC. and then click Next
button.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第6页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

4. Confirm that the setup parameter and then click OK

5. Click OK in the pop-up Warning box

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第7页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

E1/ETH Capacity Setting


1. Expand Provisioning -> MODEM Function Setting-> AMR / Radio Mapping
Configuration.

2. Input the E1 channels to be used, STM-1 must be 0, ETH bandwidth will be


calculated automatically, and then click Next button.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第8页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲
3. Confirm that the setup parameter and then click OK

4. Click OK in the pop-up Warning box

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第9页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Date / Time Setting


1. Expand Equipment Utility -> Date/Time Setting->Modify

2. Set the date and time for IDU.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 10 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

TX Power Setting
1. Expand Provisioning -> MODEM Function Setting-> TX Power Setting

2. Click the MODEM1 to configure. The TX Power Setting dialog box appears.

3. Assign a proper value for each parameter. Then, click OK


4. Click OK in the pop-up Information box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 11 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Network Setting- Set IP for IDU


1. Click the Maintenance button on the top of the LCT window to turn on the maintenance
mode.
2. Expand Equipment Setup -> Network Management Configuration->General
Setting
3. Click Setup button. The General Setting box appears

4. The default IP address is 172.18.0.1 for Near End site IDU, 172.18.0.2 for Far End
site IDU.

Network Setting- Enable NMS/NE1 Port


1. Click the Maintenance button on the top of the LCT window to turn on the maintenance
mode.
2. Expand Equipment Setup -> Network Management Configuration->General
Setting(detailed)

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 12 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲
3. Click Setup button. Set NMS and NE1 port as used.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 13 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

E1 Port Setting
1. Expand Provisioning -> E1/STM-1/Cross Connect Setting -> E1 Port Setting

2. Click the Modify button. The E1 Port Setting (Main Board) dialog box appears

3. Assign a proper value for each parameter. Then, click OK


4. Click OK in the pop-up Information box

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 14 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

ETH Function - Port Setting


1. Expand Provisioning-> ETH Function Setting -> ETH Port Setting

2. Click the desired Port No. to configure. The ETH Port Setting dialog box appear

3. Click OK in the pop-up Information box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 15 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

ETH Function-Bridge Setting


1. Expand Provisioning-> ETH Function Setting -> Bridge Setting
2. Click the Modify button.

ETH Function -VLAN Setting-Adding


1. Expand Provisioning -> ETH Function Setting ->VLAN Setting

2. Click VLAN List tab. The VALN List tab appears.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 16 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

3. Click the Add VLAN ID button to create a new VLAN ID.

ETH Function -VLAN Setting-Setting


1. Expand Provisioning-> ETH Function Setting-> VLAN Setting
2. Click Port No. button. The VLAN Setting window appears

Notes:1.Select which Port will be used, and the Vlan mode is Access or
Trunk depend on the BTS. If the IP packet from BTS with TAG, select
Trunk mode. If no Tag, select Access mode.
2. Setting Modem1 as Trunk mode, too(must be Trunk mode).

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 17 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

3. Click OK in the pop-up Information box.

ETH Function –FDB Setting


1. Expand Provisioning-> ETH Function Setting-> FDB setting
2. Click Equipment button. Set the parameters as shown in the picture below.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 18 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

RX level & alarm Check


1. Expand Metering-> Current Metering

2. Click MODEM1

3. Confirm the RX level is up to the design value, and the BER is better than 0.0E-8.
4. Expand Current Status-> Active alarm

5. Confirm no alarm such as: LOF, RX level, ODU alarms.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 19 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Link Performance Check


1. Expand Current/History PMON/RMON Report --> MODEM PMON Report

2. Click Modem1

3. Confirm the value of UAS,ES, SES are 0 in the past 30 minutes.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 20 页
All Rights reserved, No Spreading abroad without Permission of ZTE