You are on page 1of 8

Easy to Use and Versatile

Data Recording Solutions

6100A & 6180A Paperless


Graphic Recorders

Product at a Glance
The 6000 Series offer world leading input accuracy with a 125ms
total sample rate for up to 48 input channels. Input channels • Color touchscreen display
are freely configurable to suit your process requirements. Each
• USB “plug & play”
instrument has an intuitive, touch screen display to enable operators
• Up to 48 universal Inputs
to clearly view process data in varying formats. All have onboard
Flash data storage capability, Ethernet communication and a choice • Up to 96 MB non-volatile flash memory
of removable media. Data is stored in a tamper-resistant binary • 125ms parallel sampling
format that can be used for long term records of your process. The • Compact Flash card
6000 Series is truly designed for todays networked world and can be • Modbus RTU
accessed via a Local Area Network, dial-up connection, Intranet or
• Ethernet TCP/IP
Internet.
• Web server
Overall range • EtherNet/IP server
(
• Multi-language support
Standard
(French, Dutch, German, Italian, Japanese,
Available features
Korean, Portuguese, Russian and
° C)
Simplified Chinese)
6100A 6180A

Display 5.5” 1/4 VGA 12.1” XGA

Channels 18 48

Relays 12 27

Events inputs 24 (6 per option card)

Groups 6 standard (12 options)

Auditor features Auditor or audit trail

Analogue ouputs Output 8 (2 per card)

Virtual channels* 36, 96, 128

Timers Fitted as standard

Alarms 4 per channel

Batch Optional

Bridge-remote viewing software Lite as standard (Full optional)

Screen builder 24 (optional)

Unlimited unique user names with configurable


Security
access permissions and passwords

Configuration software Standard

Reviews/Quickchart Lite software Standard

Vertical and horizontal trending


Standard views Vertical and horizontal bar graphs
Circular trend and numeric values
Imagine Absolute Data Records Forever
* Virtual channels can be configured as maths, totalisers, counters or comms
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 2

Data Logging and Archiving Dynamic Host Configuration Protocol (DHCP)


The 6000 Series recorders have internal Flash memory for high integrity Dynamic Host Configuration Protocol, the successor to BootP, allows a 6000
data storage. They are also able to accept various removable media types Series host to obtain Network parameters, such as IP address, Subnet Mask,
(Compact Flash or USB memory stick). Data stored within the internal memory default gateway and DNS server address dynamically. The implementation of
can be archived to the removable media on demand or at preset intervals. The DHCP on the 6000 Series significantly reduces the overhead for maintaining a
6000 Series will give an indication of how long its internal memory and that of network of instrumentation.
the removable media installed will last according to the configuration of the
recorder.

The 6000 Series can be configured to archive to the removable media and/or
Specification
over Ethernet. Archiving files over Ethernet effectively gives infinite archiving Recorder
capacity.
Environmental performance
Approximate duration for continuous recording of one group of six channels,
high compression: Temperature limits Operation: 0 to +50° C
Storage: –20 to 60° C
Humidity limits Operation: 5% to 80% RH
Archive Media Sample Rate Storage: 5% to 90% RH
0.125s 0.5s 1s 5s 10s 30s 60s Protection Bezel and display: IP66
Sleeve: IP20
96Mb Internal Flash
8.49 33.9 67.8 339 1.85 5.5 11.1 6100A Portable case option: IP21
(approx. 12 million Shock: BS EN61010
days days days days yrs yrs yrs
samples) Vibration (10 to 150Hz): BSEN60873, Section 9,18
256Mb CF Card or USB
Altitude: <2000 meters
22.6 90.6 181 2.4 4.9 14.8
memory stick (approx, 20 yrs
days days days yrs yrs yrs
32 million samples) Approvals
8Gb CF Card or USB Electromagnetic compatibility: CE, cUL (EMC)
1.9 15.2 76.8 152 464 928
memory stick (approx. 7.8 ys
yrs yrs yrs yrs yrs yrs
1000 million samples) UL file number: e57766
Ethernet (FTP Server) Infinite Emissions and immunity: BS EN61326

Electrical safety
Time Synchronization (SNTP)
The 6000 Series support Simple Network Time Protocol which, when enabled, (BS EN61010): Installation cat. II; Pollution degree 2
updates the instrument time every 15 minutes from the configured SNTP
server. The unit can also act as a Unicast SNTP server on the network, allowing INSTALLATION CATEGORY II
client instruments to synchronize with the 6000 Series to a resolution of one The rate impulse voltage for equipment on nominal 230V mains is 2500V.
millisecond. POLLUTION DEGREE 2
Normally, only non-conductive pollution occurs. Occasionally, however, a
temporary conductivity caused by condensation shall be expected.
Batch Recording
Up to ten user-defined fields can be used to enter batch specific data. Physical

Panel mounting: DIN43700


Field Descriptor Operator Entered Batch Information Panel mounting angle: ±45°
6100A Bezel size: 144 x 144 mm
up to 20 characters up to 60 characters
Panel cutout dimensions: 138 x 138 mm (both –0/+1 mm)
Depth behind bezel rear face: 246.5 mm (284 LTC)
The user can choose to log any number of the given fields on start and/or stop of
Weight: 3 kg max. (5 kg if fitted in portable case)
a batch. The information will appear on the chart as a message and cannot be 6180A Bezel size: 292 x 292 mm
separated from the process data to which it relates. Panel cutout dimensions: 281 x 281 mm (both –0/+1 mm)
Depth behind bezel rear face: 261 mm
Weight: 7 kg max.
Auditor Features
Auditor Operator interface
Designed to aid compliance to FDA regulation 21 CFR Part 11 for Electronic
Type: Color TFT LCD with cold cathode
Records and Signatures, this software option provides the 6000 Series with backlight, fitted with resistive, analog,
additional access controls such as password ageing, electronic signatures and Touch-Panel
time stamped audit trail. Size and resolution
Model 6100A: 1/4VGA (320 x 240 pixels) 5.5”
Model 6180A: XGA (1024 x 768 pixels) 12.1”
Audit Trail
A sub-set of the Auditor which provides the 6000 series with a time stamped Power requirements
audit trail. It does not include password ageing and electronic signatures.
Supply voltage Standard: 100 to 230V ac ±15%; 47 to 63Hz
or 110 to 370 V dc
Mircosoft ® Active Directory ® Directory Service Power (Max): 60 VA (Inrush current 36 A)
A utility intended for User Access Administration of PCs. It is a tool used by the Fuse type: None
IT administrators to manage user access across the company wide network. It Interrupt protection Standard: Holdup >200 msec, at 240V ac,
allows users to be given access according to their functions by allocating them with full load
to a group with defined privileges. It also includes the necessary features such
as password expiry, auto-logout, minimum length password, etc. It allows the
Back-up battery
users to manage their password from any node on the system.
Type: Poly-carbonmonofluoride/lithium
Modbus Master (BR2330) Part No. PA261095
Support time (RTC): 1 year min. with recorder unpowered
Allows users to view data from multiple instruments connected either by a local Replacement period: 3 years
Network connection using Modbus TCP, or a Serial connection using Modbus Stored data: Time; date; values for totalisers, counters
RTU. and timers; batch data; Fvalue,
Rolling average, Stopwatch etc.

The 6000 Series Recorders Ethernet communications


ASCII printer output (reports)Fitted as standard the ASCII text printer option
provides the 6000 Series with the ability to generate up to 10 simple reports that Type: 10/100baseT Ethernet. (IEEE802.3)
Protocols: TCP/IP, FTP, DHCP, BOOTP, SNTP, Modbus,
can be directed to a Serial ASCII text printer. Reports, triggered by an event/job SMTP, ICMP, EtherNet/IP server
can be configured to contain parameters such as time and date, batch names, Cable Type: CAT5
process values and user defined messages. Maximum length: 100 meters
Termination: RJ45
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 3

Serial Communications Option Thermocouple data

No of ports: 2 Temperature scale: ITS 90


Protocol: ASCII (typical applications: Input of ASCII Bias current: 0.05 nA
string inputs from Barcode readers, Credit Cold junction types: Off, internal, external, remote
card readers etc.) CJ error: 1°C max with inst. at 25°C
ASCII printer support CJ rejection ratio: 50:1 minimum
Modbus RTU Master and Slave Isolation Upscale/downscale drive High, low or none selectable for
(dc to 65Hz) each thermocouple channel
Additional error: 0.01°C (typ.) if high or low selected
BS EN61010): Installation category II; Types and ranges: See Table 3
Pollution degree 2
Terminals to ground:
Transmission standard:
50V RMS or dc (basic insulation) Table 3 Thermocouple types and ranges
EIA232 or EIA485 (software selectable)
Overall range Standard Max linearization
Input Board T/C Type
(° C) error
General
0 to 400° C=1.7° C
B 0 to +1820 IEC 584.1
Input types: dc Volts, dc millivolts, 400 to1820° C=0.03° C
dc milliamps (with shunt),
Thermocouple, 2/3-wire RTD C 0 to +2300 Hoskins 0.12° C
Contact closure (not Channels 1, 7, 13, 19, D 0 to +2495 Hoskins 0.08° C
25, 31, 37, 43) >60 ms
Input type mix: Freely configurable E –270 to +1000 IEC 584.1 0.03° C
Maximum number of inputs: 6 per board
A/D conversion method: >16 bits, 2nd order delta sigma G2 0 to +2315 Hoskins 0.07° C
Input ranges: See Table1 and Table 2 below
Termination: Edge connector / terminal block J –210 to +1200 IEC 584.1 0.02° C
Noise rejection (48 to 62Hz): Common mode: >140dB (channel to K –270 to +1372 IEC 584.1 0.04° C
channel and channel to ground)
Series mode: >60 dB L –200 to +900 DIN43710:1985 (To IPTS68) 0.02° C
Max. common mode voltage: 250 Volts continuous
Max. series mode voltage: 45 mV at lowest range; N –270 to +1300 IEC 584.1 0.04° C
23.74 Volts peak at highest range
Isolation R –50 to +1768 IEC 584.1 0.04° C
Channel to channel: 300V RMS or dc (double insulation)
Channel to common S –50 to +1768 IEC 584.1 0.04° C
electronics: 300V RMS or dc (double insulation) T –270 to +400 IEC 584.1 0.02° C
Channel to ground: 300V RMS or dc (basic insulation)
Dielectric strength U –200 to +600 DIN43710:1985 0.08° C
(BS EN61010) (1 minute type tests)
Channel to channel: 2500V ac NiMo/NiCo –50 to +1410 ASTM E1751-95 0.06° C
Channel to ground: 1500V ac
Insulation resistance: >10 MΩ at 500V dc Ni/NiMo 0 to +1406 Ipsen 0.14° C
Input impedance: 38 mV, 150 mV, 1V ranges: >10 MΩ; Platinel 0 to +1370 Engelhard 0.02° C
20V range: 65.3 kΩ
Over voltage protection: 50 Volts peak (150V with attenuator) Pt20%Rh/
Open circuit detection: ± 57 nA max. 0 to +1888 ASTM E1751-95 0.07° C
Pt40%Rh
Recognition time: 500 msec
Minimum break resistance: 10 MΩ
Resistance Inputs

Table 1 Voltage ranges — accuracy and resolution Ranges (including lead resistance): 0 to 150 Ω, 0 to 600 Ω, 0 to 5 kΩ
Influence of lead resistance Error: Negligible
Worst case Mismatch: 1 Ω/Ω
Typical error Maximum error temp Temperature scale: ITS90
Low High (instrument at (instrument Performance Accuracy and resolution: See Table 2
Range Range Resolution 20° C) Range at 20° C) Range Input per °C RTD types and ranges: See Table 4
-38 mV 38 mV 1.4 μV 0.013% I/P + 0.031% 0.030% I/P + 0.052% 25 ppm
Table 4 RTD types and ranges
-150 mV 150 mV 5.5 μV 0.013% I/P + 0.028% 0.029% I/P + 0.039% 25 ppm
Overall range Standard Max linearization
-1 V 1V 37 μV 0.013% I/P + 0.024% 0.029% I/P + 0.029% 25 ppm RDT Type
(° C) error
-20 V 20 V 720 μV 0.075% I/P + 0.027% 0.393% I/P + 0.033% 388 ppm Cu10 –20 to +400 General Electric Co. 0.02° C
Cu53 –70 to ± 200 RC21-4-1966 <0.01° C
Table 2 Resistance ranges — accuracy and resolution
JPT100 –220 to +630 JIS C1604:1989 0.01° C
Worst case
Typical error Maximum error temp Ni100 –60 to +250 DIN43760:1987 0.01° C
Low High (instrument at (instrument Performance
Ni120 –50 to +170 DIN43760:1987 0.01° C
Range Range Resolution 20° C) Range at 20° C) Range Input per °C
0Ω 150 Ω 5 mΩ 0.027% I/P + 0.034% 0.037% I/P + 0.077% 30 ppm Pt100 –200 to +850 IEC 751 0.01° C
Pt100A –200 to +600 Eurotherm Recorders SA 0.09° C
0Ω 600 Ω 22 mΩ 0.027% I/P + 0.035% 0.037% I/P + 0.057% 30 ppm
Pt1000 –200 to +850 IEC 751 0.01° C
0Ω 5 KΩ 148 mΩ 0.030% I/P + 0.034% 0.040% I/P + 0.041% 30 ppm

Analogue output board


Update/archive rates
General
Input/Relay-output sample rate: 8Hz Max number. of OP boards Four
Trend update: 8Hz maximum Number of OPs per board Two
Archive sample-value: Latest value at archive time Output ranges
Display value: Latest value at display update time Voltage: 0 to 10V (source 5mA max.)
(1Hz) Current: 0 to 20mA (max. load 1K Ω
Update rate: 8Hz
DC Input ranges Step response: 250msec (10% to 90%)
Linearity: 0.024% of hardware range
Shunt: Externally mounted resistor modules Performance: See table
Additional error due to shunt: 0.1% of input
Additional error due to
attenuator: 0.2% of input Performance
Performance: See Table 1
Range Accuracy Temperature drift
0 to 10V 0.2% of range ± 0.12mV +0.022% of reading per °C
0 to 20mA 0.1% of range ± 1μA + 0.03% of reading per °C
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 4

Transmitter PSU Portable


Isolated, 6100A recorder only Portable option

Number of outputs: Three


Output voltage: 25V nominal
Maximum current: 20 mA per output 6100A is available as a
Isolation Installation category II; General(PORTGEN) or
(dc to 65Hz; BS61010): Pollution degree 2
Thermocouple (PORTUTC)
Channel to channel: 100V RMS or dc (double insulation)
portable
Channel to ground: 100V RMS or dc (basic insulation)
Fuse (20mm Type T)
Supply voltage: 110/120V ac: 100 mA
220/240V ac: 63 mA

Relay Output Board


General

Max. number of relay boards 6180A is available with optional


6100A: 4 (max. no of relay outputs = 12) carry handle and feet for
6180A: 9 (max. no of relay outputs = 27) portability
No. of relays per board: 3 per C/O
Estimated mechanical life: 30,000,000 operations
Update rate: See “Update rates” in “Recorder
Specification” above

AC load ratings
Derating
The figures give below are for resistive loads. for reactive or inductive Max. No Option Serial Transmitter Event
loads, de-rate in accordance with Graph 1, in which: 6100A Relays
of I/Ps** Slots** Comms PSU I/P
F1 = Actually measured results on General 18 4 Yes* Yes Yes* Yes*
representative samples
F2 = Typical values according to experience PORTUTC 15 0 No Yes No No**
Contact life = Resistive contact life x reduction factor
** Mutually exclusive
Max. switching power: 500VA
* Requires one option slot
Max. contact voltage: 250V providing this does not cause the
maximum switching power (above) to be

Max. contact current:


exceeded
2 Amps providing this does not cause the
Portable Mechanical Details
maximum switching power (above) to be
exceeded 6100A
DC load ratings Front view Side elevation

40.5 mm
Max. switching power: See Graph 2 for operating volt/amp 430 mm
envelope 190 mm 384.8 mm
Max. contact voltage/current: See Graph 2 for examples
Safety isolation

153 mm
190 mm

Isolation Installation category II;


(dc to 65Hz; BS EN61010): Pollution degree 2
Relay to relay: 300V RMS or dc (double insulation)
Relay to ground: 300V RMS or dc (basic insulation)
F Max. DC load breaking capacity 15 mm
1 300
0.9
F2 200
0.8 resistive load
Top view
DC Voltage (Volts)
Reduction Factor F

0.7 F1 100
38 mm

0.6
50 300 mm
0.5 40 inductive
30 load (L/R
0.4 20 = 20msec)
174 mm

0.3 10
1 0.8 0.6 0.4 0.2 0.1 0.2 0.5 1 2 5 20
Power factor (cos f) DC current (Amps)

Graph 1 Graph 2
Derating curves for ac loads DC load switching curves
Event Input
Number of inputs: 6 discrete inputs 6180A
Max. number of boards Front view Side elevation
6100A: 4
6180A: 4
Isolation
Event input to ground: 50V RMS or dc (double insulation)
336 mm

Event input to Event input: 0V


292 mm

279 mm

Recognition levels “Active”: –30V to +0.8V


216 mm

“Inactive”: +2 to +30V
Maximum frequency: 8 Hz
Minimum pulse width: 62.5 ms
Contact resistance Event: Active if resistance <35 KΩ
Inactive if resistance >200 KΩ Access Flap
Status not defined if 35K Ω < resistance
<200 KΩ between input terminal and ‘C’ 292 mm 289 mm
terminal
359 mm
Current sink (voltage I/P): 10 mA
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 5

Mechanical Details
6100A 6180A

24.75 mm

28.34 mm
Front view Side elevation Front view Side elevation

246.5 mm* 260.90 mm


144 mm 211.5 mm 292 mm 211 mm

106.9 mm
137 mm
144 mm

102 mm

292 mm

279 mm
216 mm
Access Flap 35 mm
Panel thickness 6 to 25 mm max
Optimum thickness depends on panel material Access Flap
Panel thickness 6 to 25 mm max
x Optimum thickness depends on panel material
x
137 mm

) y
)

279 mm
View on underside

* Standard Terminal Cover: 246.5 mm y = 12.5 mm (0.5 in)


)
y
Long Terminal Cover: Closed: 288 mm
Open: 415 mm
View on underside
Panel cut-out Panel cut-out
138 mm (+1 –0) x 138 mm (+1 –0) 281 mm (+1 –0) x 281 mm (+1 –0)

Minimum recommended Minimum recommended inter-unit spacing


inter-unit spacing
Side clamps Top/bottom clamps
Side clamps Top/bottom clamps
x = 25 mm (1 inch) x = 12.5 mm (0.5 inch)
x = 15 mm (0.6 inch) x = 10 mm (0.4 inch) y = 12.5 mm (0.5 inch) y = 25 mm (1 inch)
y = 10 mm (0.4 inch) y = 15 mm (0.6 inch)
Maximum Installed Angle Panel mounting technique
a = b = 45 degrees max
Maximum Installed Angle Panel mounting technique
a = b = 45 degrees max

a˚ b˚
a˚ b˚

Isolated Transmitter Power Supply Wiring (6100A only)


Recorder rear terminal panel Long Terminal Cover Input Board Wiring
Channel input
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
1,7,13,19, 2,8,14,20, 3,9,15,21, 4,10,16,22, 5,11,17,23, 6,12,18,24,
Channels
Transmitter Power Supply PCB 25,31,37,43 26,32,38,44 27,33,39,45 28,34,40,46 29,35,41,47 30,36,42,48
V+ V-V- II
V+ V– I V+ V+ V- I V+ V- I CJC V+ V- I V+ V- I V+ V- I

R
Black

Black

Black
Red

Red

Red
Black
Red

Relay Board Wiring


User Terminal Block
Three changeover relays

– – – 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
+ + + 2 Option
boards
nc c no nc c no nc c no nc c no nc c no nc c no

– + Other transmitters Relay 1 2 3 1 2 3

Four Normally-Closed relays board


Transmitter
45
1 46
2 47
3 48
4 49
5 50
6 51
7 52
8 53 54 11
9 10 55 12
56 13
57 14
58 15
59 16
60 17
61 18
62 19
63 20
64 21
65 22
66
Voltages generated by 2 Option
various currents for boards
c nc c nc c nc c nc c nc c nc c nc c nc
R=100W and R=250W
(R minimum spec) Relay 1 2 3 4 1 2 3 4
= 1.4W ±1% Only one channel shown for clarity
Four Normally-Open relays board
100W 250W
0mA 0V 0V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
2 Option
4mA 0.4V 1.0V
boards
20mA 2.0V 5.0V c nc c nc c nc c nc c nc c nc c nc c nc

Relay 1 2 3 4 1 2 3 4
nc
Max number of boards =
4 for small frame and 9 for large frame c
Contacts shown in
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 6

Input Board Signal Wiring

V+ V- I V+ V- I V+ V- I V+ V- I V+ V- I V+ V- I I V+ V- I

nc
Shunt
com

+ – RTD RTD Potentiometer no


+ – + –
Attenuator Minimum
Assembly contact = 60 ms

–20 to +20V dc DC millamps –200 to + 200V dc 3-wire resistance 2-wire resistance Potentiometer Contact closure
Thermocouples thermometer thermometer (Not Chs 1,7,13 etc.)
dc mV
Shunt assembly Attenuator assembly
100W = LA246779UK10 LA244180
250W = LA246779UK25

Event Input Board Wiring


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
2 Option boards
1 2 3 4 5 6 C 1 2 3 4 5 6 C

Event input number 1 2 3 4 5 6 C 1 2 3 4 5 6 C

Behaviour undefined
for +0.8 < Vin < +2

Input 6 shown
inputs 1-5 identical

2 to 30V

0.8 to –30V

User 0V
Contact closure inputs Voltage inputs

Rear Terminal Connections


6100A
Serial communication port pinout
Pin EIA232 EIA485 (5-wire) EIA485 (3-wire)
1 Not connected RxA Link to pin 7
2 Rx Not connected Not connected 1 2
3 Tx Not connected Not connected 1 22
4 DTR Not connected Not connected 3 4
5 Signal ground 1 22 Option board
6 Not Connected RxB Link to pin 8
7 Not Connected TxA TxA/RxB 7 - 12 Input channels
1 22
8 Not Connected TxB TxB/RxA
9 5.0V via 1500W 1-6
1 22
Ethernet
Channels 13-18
USB 1 USB 2 connector 6180A (if fitted) occupy
(option)
1 2 3 4 5 1 2 3 4 5 option board
slots 3 and 4

6 7 8 9 6 7 8 9
Serial 1 Serial 2
5 6

1 2 Option
Option 7 8
boards
boards
3 4 9

43 - 48
1 22
37 - 42
1 22 31 - 36
Input
1 22
25 - 30 channels
Input 1 22 19 - 24
channels 1 22
13 - 18
1 22 7 - 12
1-6 1 22
1 22
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 7

Order Codes
1 2 3 4 5 6 7 8 9 10 11 12 13

VH

14 15 16 17 18 19 20 21 22 23 24 25 26 27

28 29 30 31 32 33 34

Basic Product 11 Memory Card 22 Quantity of Shunts


6100A 100mm TFT 1/4 VGA Display Paperless Graphic Recorder NOMC Not fitted __ Enter quantity required
6180A 180mm TFT XGA Display Paperless Graphic Recorder 004G 4 GB Card CF only*
008G 8 GB Card CF only* 23 Shunt Value
1 Number of Channels NOS Not required
12 USB Memory Stick Size 100 100 ohm shunts
U00 0 Input channels
NOMC Not fitted 250 250 ohm shunts
U06 6 Input channels
004GMS 4 GB*
U12 12 Input channels
008GMS 8 GB* 24 Quantity of 100:1 Attenuators
U18 18 Input channels
U24 24 Input channels (6180A only) __ Enter quantity required
13 Rear USB
U30 30 Input channels (6180A only)
U36 36 Input channels (6180A only) 0RUSB No rear USB ports 25 Warranty
U42 42 Input channels (6180A only) 2RUSB 2 USB ports at rear XXXXX Standard warranty
U48 48 Input channels (6180A only) WL005 Extended warranty
14 Serial Communications Ports
0SRL Not fitted 26 Bridge
2 Industry Variant
2SRL EIA 232/422/485
NONE None BLITE Lite (supplied as standard)
TUS AMS2750E Heat Treatment specific variant BFULL Full
15 EtherNet Communications
Protocol
3 Number of Channels NONE Not fitted 27 Review & Quickchart

PANEL ESERV EtherNet/IP server RLITE Lite (supplied as standard)


Panel mounting
PORTGEN RFULL Full
General Portable (6100A only)
PORTUTC Universal Thermocouple Portable (6100A only) 16 Calibration Certificates
CH Carry handle (Bezel Colour Silver) NOCAL Not required 28 Auditor
PMHD Panel mounting with Heavy Duty Case Clamps CAL Calibration certificate NOADT Not required
PMTN Panel mounting with Thin panel mounting kit ALITE Audit Trail
17 Changeover Relays AFULL Auditor Full
4 Lock 00 Not fitted
NOLCK Media lock not fitted 03 3 (1 option brd) 29 Security Manager
LOCK Electronic lock fitted 06 6 (2 option brds) NOSM Not required
09 9 (3 option brds) SECMAN Security Manager
12 12 (4 option brds) (inc. Active Directory)
5 Bezel Color
15 15 (5 option brds) †
SLV Silver including portable options
18 18 (6 option brds) † 30 Groups
BLK Black
21 21 (7 option brds) † 06GROUP 6 (supplied as standard)
24 24 (8 option brds) † 12GROUP 12
6 Power Supply 27 27 (9 option brds) †
VH 90-264V ac (110-370 V dc) 47-63 Hz † (6180A only)
31 Math, Totalizers & Counters
MTC00 Not required
7 24V Isolated Transmitter Power Supply 18 Normally Closed Relays MTC36 36 Virtual Channels
NONE Not fitted 00 Not fitted MTC96 96 Virtual Channels
115TPS 110-120V 3 channel TPS (6100A only) MTC128 128 Virtual Channels
230TPS 220-240V 3 channel TPS (6100A only) 19 Normally Open Relays
00 Not fitted 32 Batch
8 Non Standard NOBTCH Not required
20 Event Inputs
XXXXXX Non standard option BATCH Batch
00 Not fitted
06 06 (1 brd)
9 Internal Memory 33 Screen Builder
12 12 (2 brds)
096M 96 MB for history – approx. 12 million samples 18 18 (3 brds) NOSB Not required
24 24 (4 brds) ADSB Advanced
10 Removable Media
CF Compact Flash and Front USB port 21 Analog Outputs 34 Master Communications
00 None NOMSTR Not required
02 2 (1 option brd) MSTR16 16 Slaves
04 4 (2 option brd) MSTR32 32 Slaves
06 6 (3 option brd)
* Please consult Eurotherm for this option
08 8 (4 option brd)
6100A & 6180A Paperless Graphic Recorders Data Sheet eurotherm.co.uk/6100a-6180a 8

6100A & 6180A Paperless


Graphic Recorders Specification

Eurotherm Limited
Faraday Close, Durrington,
Worthing, West Sussex BN13 3PL
Phone: + 44 (01903) 268500
www.eurotherm.co.uk

Document No. HA029073 Issue 8 © 2017 Schneider Electric. All rights reserved. Schneider Electric, Life Is On, Eurotherm, EurothermSuite, eCAT, EFit, EPack, EPower,Eycon, Eyris,
Chessell, Mini8, nanodac, optivis, piccolo, and versadac are trademarks of Schneider Electric SE, its subsidiaries and affiliated companies. All other trademarks are the property of
their respective owners.

You might also like